912 resultados para Deep pool


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilio-femoral deep vein thrombosis (DVT) has a high rate of long-term morbidity in the form of the postthrombotic syndrome (PTS). Therefore, management of acute thrombosis should not only focus on the prevention of acute complications such as propagation or embolisation of the initial clot but also on preventing PTS and recurrent thrombosis. Contemporary catheter-based treatments of deep vein thrombosis have proven to be safe and effective in selected patients. Current guidelines recommend medical therapy with anticoagulation alone for all but the most severe, limb-threatening thrombosis. They additionally allow for consideration of catheter-based treatment in patients with acute DVT and low risk of bleeding complications to prevent PTS. Recent studies favoring interventional therapy have not been included in these guidelines. Data on long-term outcome is expected to be published soon, clarifying and very likely strengthening the role of catheter-based treatments in the management of acute ilio-femoral DVT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the use of transluminal coil embolization to treat pseudoaneurysm of deep femoral artery branch in two patients. The pseudoaneurysms had developed after coronary angiographv in one patient and after hip replacement in the other. Immediate control angiography after embolization procedures demonstrated complete closure of the pseudoaneurysms. During follow-up of 19 and 3 months, respectively, there was no recurrent bleeding. The aim of this case report is to show the advances in endovascular microcatheter technology, and embolic materials, that made percutaneous transluminal embolization of arterial pseudoaneurysms safe and efficient. In addition, it keeps the medical personnel aware of vascular injuries at the access site related to endovascular procedures as well as vascular complications of total hip arthroplasty. It calls their attention to the possibility of endovascular treatment as an alternative to surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate lymphatic clearance of the human skin in patients with acute deep thrombosis of the femoral vein. In 13 patients with deep vein thrombosis and no other cause for swelling of the limbs, lymphatic clearance of the skin at the foot was measured. Ten microliters of fluorescein isothiocyanatedextran 150,000 were injected intradermally and the fluorescent light intensity of the deposit measured 10 min and 24 hours after injection by window densitometry. In addition, intralymphatic pressure was measured by the servo-nulling system. The results were compared with a sex- and age-matched control group. Fluorescent light intensity decreased by 23.8 +/- 12.3 arbitrary units or by a factor of 1.8 +/- 0.5 in patients with DVT after 24 hours, which was significantly less than in healthy controls (33.7 +/- 8.9 arbitrary units or by factor 5.0 +/- 4.1, p < 0.013). Intralymphatic pressure was not different between the two groups. These results indicate that lymphatic clearance is significantly reduced in the acute phase of deep venous thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to test whether the status of the adjacent tooth surface has an influence on the signal of a new laser fluorescence (LF) device for the detection of approximal caries. Seventy-eight teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured the teeth were defrosted, cleaned, and any calculus removed. As a control, a defined approximal surface of each tooth was measured with the LF device holding the tip with the detecting- and the reverse-side on it, but without a neighboring tooth contacting the surface. The proximal site under examination was then placed adjacent to a tooth, which had deep dentinal caries, a composite restoration, a provisional ZnO-Eugenol restoration, or a ceramic restoration. The adjacent tooth with the ZnO-Eugenol restoration, the composite restoration, and the dentinal caries all demonstrated a statistically significant increase of LF readings on sound tooth surfaces. Teeth with enamel or dentinal caries were only slightly (and not statistically significantly) influenced by the different types of neighboring surfaces compared with the control LF readings. It can be concluded that caries detection of approximal tooth surfaces with the new LF system might be influenced by the condition of the adjacent tooth surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Class II cavities were prepared in extracted lower molars filled and cured in three 2-mm increments using a metal matrix. Three composites (Spectrum TPH A4, Ceram X mono M7 and Tetric Ceram A4) were cured with both the SmartLite PS LED LCU and the Spectrum 800 continuous cure halogen LCU using curing cycles of 10, 20 and 40 seconds. Each increment was cured before adding the next. After a seven-day incubation period, the composite specimens were removed from the teeth, embedded in self-curing resin and ground to half the orofacial width. Knoop microhardness was determined 100, 200, 500, 1000, 1500, 2500, 3500, 4500 and 5500 microm from the occlusal surface at a distance of 150 microm and 1000 microm from the metal matrix. The total degree of polymerization of a composite specimen for any given curing time and curing light was determined by calculating the area under the hardness curve. Hardness values 150 microm from the metal matrix never reached maximum values and were generally lower than those 1000 microm from the matrix. The hardest composite was usually encountered between 200 microm and 1000 microm from the occlusal surface. For every composite-curing time combination, there was an increase in microhardness at the top of each increment (measurements at 500, 2500 and 4500 microm) and a decrease towards the bottom of each increment (measurements at 1500, 3500 and 5500 microm). Longer curing times were usually combined with harder composite samples. Spectrum TPH composite was the only composite showing a satisfactory degree of polymerization for all three curing times and both LCUs. Multiple linear regression showed that only the curing time (p < 0.001) and composite material (p < 0.001) had a significant association with the degree of polymerization. The degree of polymerization achieved by the LED LCU was not significantly different from that achieved by the halogen LCU (p = 0.54).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focal osteochondral defects are still a challenging problem in joint surgery. We have developed a two-layered implant consisting of a basal porous beta-tricalcium phosphate (TCP) for bone reconstruction and a superficial fibrous collagen type I/III layer for cartilage regeneration. Fifty-four osteochondral defects in the trochlear groove of 27 Göttinger Minipigs were created and either left untreated, treated with the implant alone, or the implant augmented with an additional growth factor mixture, which was assumed to stimulate cell and tissue differentiation. Follow-up was 6, 12 and 52 weeks with n=6 for each group. The repair tissue was evaluated for its gross appearance and biomechanical properties. Histological sections were semi-quantitatively scored for their histomorphological structure. Treatment with the two-layered implant improved defect filling and subchondral bone repair at 6 and 12 weeks follow-up. The TCP was replaced by cancellous bone at 52 weeks. Cartilage repair tissue mainly consisted of fibrocartilage and showed a moderate cell density up to the joint surface. Growth factor treatment improved the mechanical and histomorphological properties of the cartilage repair tissue at 12, but not at 52 weeks postoperatively. In conclusion, the two-layered collagen-TCP implant augmented with chondroinductive growth factors seems a promising new option for the treatment of deep osteochondral defects in joint surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the efficacy of stent placement after infrainguinal loco-regional thrombolysis and iliac thrombectomy (surgical TT) of acute deep vein thrombosis (DVT) in patients with May-Thurner-Syndrome. MATERIAL AND METHODS: We retrospectively analysed a group of 11 patients (9 women) (mean age 34 years, range 16-64 years) with surgical TT and additional intra-operative stenting due to compression of the common iliac vein. Patients underwent venography to demonstrate outflow patency after surgical TT, and to identify any obstruction at the level of the left-sided common iliac vein ("Beckenvenen-Sporn"). Obstruction at the level of arterial crossing was treated using Wallstents placed via an introducer sheath from the inguinal access site. Stents were fully deployed using balloons adjusted to the size of vein. Patients were treated with oral anticoagulants for 6 months, and followed using duplex ultrasonography. RESULTS: Technical success defined as complete vein patency and normal valve function was documented in all 11 patients. One patient needed early stent extension due to residual stenosis. At 6 months follow-up one patient (9%) had an asymptomatic occlusion of the stented common iliac vein. In all 11/11 (100%) patients the femoral segment was found to be patent, and in 1/11 (9%) there was mild reflux with few clinical symptoms of post-thrombotic syndrome. The calculated cumulative primary patency rate for venous iliac stents was 82%, and assisted patency rate was 91%, which remained unchanged over a mean follow-up of 22 months. CONCLUSION: Combining surgical TT and stenting of common iliac vein obstructions in DVT is safe, effective, and results in a acceptable venous patency.