972 resultados para Co-Fe-W alloys


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diffusion of Co60 in the body centered cubic beta phase of a ZrSOTi SO alloy has been studied at 900°, 1200°, and 1440°C. The results confirm earlier unpublished data obtained by Kidson17 • The temperature dependence of the diffusion coefficient is unusual and suggests that at least two and possibly three mechanisms may be operative Annealing of the specimen in the high B.C.C. region prior to the deposition of the tracer results in a large reduction in the diffusion coefficient. The possible significance of this effect is discussed in terms of rapid transport along dislocation network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressure variations of the superconducting transition temperature Ic of a series of amorphous NixZr 1 OO-x alloys have been studied under quasmydrostatic pressures upto 8 G Pa. For amorphous samples having Ni-concentration less than 40%, i)Tc/dP is positive in sign and it decreases non linearly with increase in I. whereasdTcldP is negative in sign for Ni concentration of 45%. Comparison with the Hall coefficient (I) and the thermoelectric power (2) results for the same amorphous alloys leads to the conclusion that s-d hybridization nature of the d-band (Nil plays a central role in the sign reversal behaviour. Application of pressures greater than 2 G Pa to Ni20ZrgO led to the formation of a new phase, w-Zr. which retains its form after the pressure is released.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is a small cabinet card of an unidentified man, photographed by J. W. Cole, of Brampton, Ont. He is possibly a relative of the Bell - Sloman family, whose descendants include former Black slaves who settled in Canada. While this photograph is undated, it is believed to be taken between 1865 and 1884. The photographer's stamp is printed in gold lettering along the bottom of the card. This photograph was in the possession of Iris Sloman Bell, of St. Catharines.Two photographers by the name of Cole are known to have worked in Brampton, Ontario in the latter half of the 19th century. J.F. (John W.?) is listed as a photographer in 1882, while John W. Cole operated from 1865-1884. John W. Cole is also listed as a daguerrean artist, that is, he produced daguerreotypes. He also dabbled in commerce, selling fancy goods. Source: Phillips, Glen C. The Ontario photographers list (1851-1900). Sarnia: Iron Gate Publishing Co., 1990.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A blueprint produced by Westinghouse Electric & MFG. Co. in Pittsburgh, Pennsylvanna. The blueprint is dated 19 August 1903 and is stamped "OBSOLETE".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A letter from 2nd Vice President and General Manager of Canadian General Electric Company, Frederic Nicholls to W. B. Rankine regarding a bid for contract. The letter mentions that the bid for two alternating generators for the Canadian side of Niagara Falls was won by Westinghouse Eletric and Manufacturing Co. Nicholls also mentions that there will be other opportunites to win contracts as more machines are required. Nicholls also implies that Westinghouse may have bid under cost in an effort to secure the first of many contracts with the Canadian Niagara Power Company.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A letter from chief engineer C. Sellers to W. B. Rankine discussing the bid of I. P. Morris Co. Sellers discusses conversation with Mr. Hand of I.P. Morris.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A price list for Lawrence A. Wilson Co. Limited, 87 James St., Montreal Quebec. It is addressed to The Toronto Hunt, 52 Bay Street, Toronto. There are additional handwritten notes. One of the handwritten notes reads "ck to W. Stephen Haas"

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Receipt from H.H. Glenny Sons and Co., Importers, Buffalo, New York for chandelier globes, Jan. 25, 1887.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cette thèse est dédiée à l’étude des matériaux InMnP et GaMnP fabriqués par implantation ionique et recuit thermique. Plus précisément nous avons investigué la possibilité de former par implantation ionique des matériaux homogènes (alliages) de InMnP et GaMnP contenant de 1 à 5 % atomiques de Mn qui seraient en état ferromagnétique, pour des possibles applications dans la spintronique. Dans un premier chapitre introductif nous donnons les motivations de cette recherche et faisons une revue de la littérature sur ce sujet. Le deuxième chapitre décrit les principes de l’implantation ionique, qui est la technique utilisée pour la fabrication des échantillons. Les effets de l’énergie, fluence et direction du faisceau ionique sur le profil d’implantation et la formation des dommages seront mis en évidence. Aussi dans ce chapitre nous allons trouver des informations sur les substrats utilisés pour l’implantation. Les techniques expérimentales utilisées pour la caractérisation structurale, chimique et magnétique des échantillons, ainsi que leurs limitations sont présentées dans le troisième chapitre. Quelques principes théoriques du magnétisme nécessaires pour la compréhension des mesures magnétiques se retrouvent dans le chapitre 4. Le cinquième chapitre est dédié à l’étude de la morphologie et des propriétés magnétiques des substrats utilisés pour implantation et le sixième chapitre, à l’étude des échantillons implantés au Mn sans avoir subi un recuit thermique. Notamment nous allons voir dans ce chapitre que l’implantation de Mn à plus que 1016 ions/cm2 amorphise la partie implantée du matériau et le Mn implanté se dispose en profondeur sur un profil gaussien. De point de vue magnétique les atomes implantés se trouvent dans un état paramagnétique entre 5 et 300 K ayant le spin 5/2. Dans le chapitre 7 nous présentons les propriétés des échantillons recuits à basses températures. Nous allons voir que dans ces échantillons la couche implantée est polycristalline et les atomes de Mn sont toujours dans un état paramagnétique. Dans les chapitres 8 et 9, qui sont les plus volumineux, nous présentons les résultats des mesures sur les échantillons recuits à hautes températures : il s’agit d’InP et du GaP implantés au Mn, dans le chapitre 8 et d’InP co-implanté au Mn et au P, dans le chapitre 9. D’abord, dans le chapitre 8 nous allons voir que le recuit à hautes températures mène à une recristallisation épitaxiale du InMnP et du GaMnP; aussi la majorité des atomes de Mn se déplacent vers la surface à cause d’un effet de ségrégation. Dans les régions de la surface, concentrés en Mn, les mesures XRD et TEM identifient la formation de MnP et d’In cristallin. Les mesures magnétiques identifient aussi la présence de MnP ferromagnétique. De plus dans ces mesures on trouve qu’environ 60 % du Mn implanté est en état paramagnétique avec la valeur du spin réduite par rapport à celle trouvée dans les échantillons non-recuits. Dans les échantillons InP co-implantés au Mn et au P la recristallisation est seulement partielle mais l’effet de ségrégation du Mn à la surface est beaucoup réduit. Dans ce cas plus que 50 % du Mn forme des particules MnP et le restant est en état paramagnétique au spin 5/2, dilué dans la matrice de l’InP. Finalement dans le dernier chapitre, 10, nous présentons les conclusions principales auxquels nous sommes arrivés et discutons les résultats et leurs implications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have observed a type of giant magnetoresistance (GMR) in magnetic granular Co10Cu90 alloys. The asymmetric GMR depends strongly on the size of magnetic Co particles, which exhibit superparamagnetic behavior at given measured temperature. The asymmetric GMR points to a metastable state that develops when the sample is field-cooled, which is lost after recycling. We propose that high-field cooling produces more effective parallel alignment of small unblocked Co particle moments and interfacial magnetizations, which contributes to the further decrease of the resistance in comparison with the samples zero-field-cooled, and then applied to the same field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of new materials has been the hall mark of human civilization. The quest for making new devices and new materials has prompted humanity to pursue new methods and techniques that eventually has given birth to modern science and technology. With the advent of nanoscience and nanotechnology, scientists are trying hard to tailor materials by varying their size and shape rather than playing with the composition of the material. This, along with the discovery of new and sophisticated imaging tools, has led to the discovery of several new classes of materials like (3D) Graphite, (2D) graphene, (1D) carbon nanotubes, (0D) fullerenes etc. Magnetic materials are in the forefront of applications and have beencontributing their share to remove obsolescence and bring in new devices based on magnetism and magnetic materials. They find applications in various devices such as electromagnets, read heads, sensors, antennas, lubricants etc. Ferromagnetic as well as ferrimagnetic materials have been in use in the form of various devices. Among the ferromagnetic materials iron, cobalt and nickel occupy an important position while various ferrites finds applications in devices ranging from magnetic cores to sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of the investigation of the magnetic and structural properties of the alloy system Fe0.75–xSi0.25Sbx, where x = 0, 0.05, 0.1, 0.15, 0.2, and 0.25 synthesized by mechanical alloying followed by heat treatment are described. The x-ray diffraction reveals that all samples crystallize in the DO3-type cubic phase structure. Substituting Fe by Sb led to a de-crease in the lattice constant and the unit cell volume. The magnetic properties are investigated by vibrating sample magnetometer and show that all the samples are ferromagnetically ordered at room temperature. The Curie temperature is found to decrease linearly from (850 ± 5) K for the parent alloy to (620 ± 5) K for the alloyith x = 0.25. The satura-tion magnetizations at room temperature and at 100 K are found to decrease with increasing the antimony concentration. The above results indicate that Sb dissolves in the cubic structure of this alloy system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En una época gobernada por la razón, en la que cada decisión está sustentada en argumentos, EEUU, junto con otros Estados, ha promovido la necesidad de aplicar los principios racionales a las Relaciones Internacionales. Esta campaña se ha efectuado para evitar repetir episodios lamentables de la historia, como cuando en el nombre de Dios, pueblos con mayor poder bélico se embarcaron en cruzadas contra los más débiles. Así, hoy las acciones de los Estados, especialmente cuando incluyen el uso de la fuerza, idealmente deberían tener un sustento ideológico racional, para no repetir injusticias del pasado, y por el contrario, mostrarse como necesarias para el bienestar de la Comunidad Internacional, la cual ha legitimado intervenciones militares de un Estado, o un conjunto, que han liberado sociedades de regímenes totalitarios, o llevado la paz a territorios en guerra, al tiempo que ha condenado la violencia sin motivos aparentemente racionales. Ejemplo de condena se ve contra los ataques del 11 de septiembre del 2001, ejecutados en nombre de Dios. Pero el 11-09 no solo desencadenaron opiniones negativas, sino que llevaron a EEUU a una lucha internacional contra el terrorismo, acudiendo a intervenciones militares en países como Iraq, que sin tener relación directa con los ataques del 11-09 ha despertado interrogantes sobre la legitimidad de estas políticas. ¿Tienen el derecho EEUU para condenar a quienes hoy apelan a Dios para ejecutar sus actos? ¿Acaso EEUU está libre de pecado?. Esta monografía indagará sobre la relación religión-política exterior de EEUU, estudiándola durante la administración de George W. Bush, investigando en la historia de la nación, y observando la continuidad de esta práctica en la próxima generación de líderes del país.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El cáncer de cuello uterino y su mortalidad en Colombia ha permanecido constantes pese a los esfuerzos institucionales, distritales y nacionales que han buscado fortalecer los programas de prevención; sin embargo las estrategias actuales hacen énfasis en la toma de citología y no en la solicitud oportuna del resultado y el tratamiento de la usuaria en caso de anormalidad. METODOLOGIA: Se realizó un estudio en dos fases, un análisis descriptivo se analizaron 12875 y una segunda que involucro 257 pacientes en un análisis de casos y controles de una muestra aleatoria. RESULTADOS: Se utiliza para análisis bivariado la prueba de Chi cuadrado y regresión logística que muestran diferencias significativas en los siguientes variables: la explicación sobre la importancia del examen (p= 0.0060), importancia de la solicitud de resultado (p= 0.003), explicación sobre cuando reclamarlo (p=0.030), distancia entre residencia y centro de salud (p=0.065) DISCUSIÓN: En nuestro estudio se identificó que los factores como el acceso de la paciente al centro de salud, el tiempo del cual dispone para solicitar el resultado, si el dinero con el que cuenta la paciente para desplazarse al hospital, si es la primera vez que se realiza la citología, si le explicaron la importancia de reclamar el resultado y en que lapso de tiempo debía hacerlo, la información que tiene acerca de la importancia de realizarse la citología contribuyen en el hecho de que una paciente de esta población de un hospital público reclame o no su resultado de su citología

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivo: Comparar las complicaciones del uso de Angioseal® versus compresión manual en los pacientes llevados a cateterismo cardíaco en el Servicio de Hemodinamia de la Fundación Santa Fe de Bogotá, del 1º de enero de 2005 al 31 de diciembre de 2010, mediante punción arterial femoral percutánea. Metodología: Se realizó un Estudio Observacional, Analítico, de tipo Cohorte Retrospectiva. Partiendo de dos grupos de personas con indicación de cateterismo cardíaco por cualquier causa, uno expuesto al procedimiento con Angioseal® y el otro con compresión manual. Resultados: Con el uso de Angioseal® versus compresión manual la aparición de complicaciones fue 7,3% vs 4,1%, estas diferencias no fueron significativas (OR 1,81 IC95 0,96-3,40; RR 1,75 IC95 0,96-3,18) . La enfermedad coronaria (OR 2,27 IC95 1,07-4,79; RR 2,18 IC95 1,06-4,46) y a la colocación de stent (OR 3,49 IC95 1,82-6,69; RR 3,25 IC95 1,75-6,02 si se relacionaron significativamente con la aparición de complicaciones menores. Conclusión: No encontramos soporte para aprobar o desaprobar el uso de Angioseal® o compresión manual como manejo de la hemostasia, con respecto a las complicaciones. Sin embargo, se encontró que la colocación de stents está fuertemente relacionada con el desarrollo de complicaciones menores, lo cual hace que estos pacientes deban ser objeto de monitorización estrecha.