969 resultados para Chimeric monoclonal antibody
Resumo:
Enhancement of flavivirus infection in vitro in the presence of subneutralizing concentrations of homologous or heterologous antiserum has been well described. However, the importance of this phenomenon in the enhancement of flavivirus infection in vivo has not been established. In order to study antibody- mediated enhancement of flavivirus infection in vivo, we investigated the effect of passive immunization of mice with Japanese encephalitis virus (JE) antiserum on the outcome of infection with Murray Valley encephalitis virus (MVE). We show that prior treatment of mice with subneutralizing concentrations of heterologous JE antiserum resulted in an increase in viraemia titres and in mortality following challenge with wild-type MVE. Our findings support the hypothesis that subneutralizing concentrations of antibody may enhance flavivirus infection and virulence in vivo. These findings are of potential importance for the design of JE vaccination programs in geographic areas in which MVE co-circulates. Should subneutralizing concentrations of antibody remain in the population following JE vaccination, it is possible that enhanced disease may be observed during MVE epidemics.
Resumo:
A fast and direct surface plasmon resonance (SPR) method for the kinetic analysis of the interactions between peptide antigens and immobilised monoclonal antibodies (mAb) has been established. Protocols have been developed to overcome the problems posed by the small size of the analytes (< 1600 Da). The interactions were well described by a simple 1:1 bimolecular interaction and the rate constants were self-consistent and reproducible. The key features for the accuracy of the kinetic constants measured were high buffer flow rates, medium antibody surface densities and high peptide concentrations. The method was applied to an extensive analysis of over 40 peptide analogues towards two distinct anti-FMDV antibodies, providing data in total agreement with previous competition ELISA experiments. Eleven linear 15-residue synthetic peptides, reproducing all possible combinations of the four replacements found in foot-and-mouth disease virus (FMDV) field isolate C-S30, were evaluated. The direct kinetic SPR analysis of the interactions between these peptides and three anti-site A mAbs suggested additivity in all combinations of the four relevant mutations, which was confirmed by parallel ELISA analysis. The four-point mutant peptide (A15S30) reproducing site A from the C-S30 strain was the least antigenic of the set, in disagreement with previously reported studies with the virus isolate. Increasing peptide size from 15 to 21 residues did not significantly improve antigenicity. Overnight incubation of A15S30 with mAb 4C4 in solution showed a marked increase in peptide antigenicity not observed for other peptide analogues, suggesting that conformational rearrangement could lead to a stable peptide-antibody complex. In fact, peptide cyclization clearly improved antigenicity, confirming an antigenic reversion in a multiply substituted peptide. Solution NMR studies of both linear and cyclic versions of the antigenic loop of FMDV C-S30 showed that structural features previously correlated with antigenicity were more pronounced in the cyclic peptide. Twenty-six synthetic peptides, corresponding to all possible combinations of five single-point antigenicity-enhancing replacements in the GH loop of FMDV C-S8c1, were also studied. SPR kinetic screening of these peptides was not possible due to problems mainly related to the high mAb affinities displayed by these synthetic antigens. Solution affinity SPR analysis was employed and affinities displayed were generally comparable to or even higher than those corresponding to the C-S8c1 reference peptide A15. The NMR characterisation of one of these multiple mutants in solution showed that it had a conformational behaviour quite similar to that of the native sequence A15 and the X-ray diffraction crystallographic analysis of the peptide ? mAb 4C4 complex showed paratope ? epitope interactions identical to all FMDV peptide ? mAb complexes studied so far. Key residues for these interactions are those directly involved in epitope ? paratope contacts (141Arg, 143Asp, 146His) as well as residues able to stabilise a particular peptide global folding. A quasi-cyclic conformation is held up by a hydrophobic cavity defined by residues 138, 144 and 147 and by other key intrapeptide hydrogen bonds, delineating an open turn at positions 141, 142 and 143 (corresponding to the Arg-Gly-Asp motif).
Resumo:
OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.
Resumo:
The aim of this work was to devise a one-step purification procedure for monoclonal antibodies (MAbs) of IgG class by immobilized metal affinity chromatography (IMAC). Therefore, several stationary phases were prepared containing immobilized metal chelates in order to study the chromatographic behaviour of MAbs against wild-type amidase from Pseudomonas aeruginosa. Such MAbs adsorbed to Cu(II), Ni(II), Zn(II) and Co(II)-IDA agarose columns. The increase in ligand concentration and the use of longer spacer arms and higher pH values resulted in higher adsorption of MAbs into immobilized metal chelates. The dynamic binding capacity and the maximum binding capacity were 1.33 +/- 0.015 and 3.214 +/- 0.021 mg IgG/mL of sedimented commercial matrix, respectively. A K(D) of 4.53 x 10(-7) M was obtained from batch isotherm measurements. The combination of tailor-made stationary phases of IMAC and the correct selection of adsorption conditions permitted a one-step purification procedure to be devised for MAbs of IgG class. Culture supernatants containing MAbs were purified by IMAC on commercial-Zn(II) and EPI-30-IDA-Zn(II) Sepharose 6B columns and by affinity chromatography on Protein A-Sepharose CL-4B. This MAb preparation revealed on SDS-PAGE two protein bands with M(r) of 50 and 22 kDa corresponding to the heavy and light chains, respectively. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
The first electrochemical immunosensor (EI) for the detection of antibodies against deamidated gliadin peptides (DGP) is described here. A disposable nanohybrid screen-printed carbon electrode modified with DGP was employed as the transducer's sensing surface. Real serumsampleswere successfully assayed and the results were corroborated with an ELISA kit. The presented EI is a promising analytical tool for celiac disease diagnosis.
Resumo:
OBJECTIVE To analyze the prevalence of IgG antibodies to Toxoplasma gondii in patients infected with HIV/AIDS and the association of demographic and social variables. METHODS Descriptive cross-sectional study that included the analysis of sociodemographic data and laboratory findings of 200 patients infected with HIV/AIDS treated in a laboratory unit in Maputo, Mozambique, in 2010. Individual data for all participants were collected with a self-administered questionnaire. Plasma samples were tested for IgG testing of anti- T. gondii using hemagglutination for the analysis of antibodies. RESULTS The seroprevalence of IgG anti- T. gondii was 46.0% (95%CI 39.2;52.9), 39.3% (95%CI 29.5;50.0) in men and 50.9% (95%CI 41.9;59.8) in women, with no difference between sex (OR 1.30; 95%CI 0.95;1.77; p = 0.12). Ages ranged from 10 to 60 years, with a higher prevalence of infection in older age groups, but with no significant difference between them. Regularly consuming cattle meat (OR 1.74; 95%CI 1.04;2.89, p = 0.05), breeding cats/dogs (OR 6.18; 95%CI 3.60;10.62, p < 0.000) and having regular contact with soil (OR 3.38; 95%CI 2.19;5.21; p < 0.000) were significantly associated with risk of latent infection. CONCLUSIONS Toxoplasmosis is an infection with high prevalence in Mozambique. Cultural and behavioral aspects increase the risk. Toxoplasmosis can be responsible in our environment by the great burden of morbidity and mortality associated with meningoencephalic injuries in patients with HIV/AIDS.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Biotecnologia
Resumo:
The determination of anti-HBs as a screening test before vaccination has been advisable in order to encounter immune individuals that don't need to receive vaccine protection. A case-report is presented and three other cases are reviewed from the literature. Anti-HBs was positive in these health-care personnels that developped typical acute B hepatitis. Different subtyping involving the d/y determinants were found in the first case, but false-positive anti-HBs even with high titres, determined by RIA, were found in the other cases. Concomitant determination of anti-HBc or absence of screening tests seem to be more reasonable policies until a low-cost and risk-free vaccine is produced.
Resumo:
A sample of 1,288 inhabitants of Salvador, Bahia, Brazil, were submitted to the determination of anti-HBs using radioimmunoassay procedure, and analysed according to age, sex and income. Overall prevalence of anti-HBs was 11,8%. ranging from 6,7% among children aged less than three years old to 26,1% among those aged 30 years and older. Males presented prevalence of anti-HBs similar to female individuals, and those with a higher income showed frequencies of anti-HBs greater than those with a lower income level. The following conclusions were drawn: The high prevalence of anti-HBs observed among children suggests early contact with hepatitis B virus, possibly due to vertical transmission and intrafamiliar dissemination of the disease; the frequency of anti-HBs increases with age; the lower prevalence of anti-HBs among those with low income suggests that this group may present higher prevalence of carriers of the hepatitis B virus surface antigen.
Resumo:
Immune response against hepatitis B vaccine (CLB 3mg) was evaluated in 59 hemodialysis patients and 20 occupational risk personnel. Seroconversion was induced in 52.5% and 70.0% respectively. Twelve months after the first dose, 37.5% of patients and 60.0% of occupational risk personnel had detectable anti-HBs level. Antibody level was expressed in sample ratio units (SRU). Considering only the responders, in the patients group 38.7% had a low anti-HBs response (2.1-9.9 SRU) 32.3% a medium response (10-99.9 SRU) and 29.0% a high response (>100 SRU) while in occupational risk personnel these values were 14.3%, 64.3% and 21.4% respectively. The authors suggest the use of HBV vaccines with more elevated HBsAg concentration or a reinforced immunization schedule to improve the anti-HBs response not only for patients but also for healthy persons.
Resumo:
A serological study was carried out to evaluate the causal relationship of acute diarrhoea and rotavirus in children under five years of age. The rotaviral infection was demonstrated in paired sera by determining the antibody titers by immunofluorescence test (IF). Bovine rotavirus-infected MA-104 cell culture was used as substratum for IF. Out of 80 paired sera it was shown that 23 (28.75%) presented seroconversion, 19 (23.75%) samples showed a twofold increase in their titers and 38 (47.5%) had no increase in rotavirus antibody. This result is discussed on the light of previously obtained results on viral antigen detection by counterimmunoelectrosmophoresis (CIEOP).
Resumo:
Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.
Resumo:
During 1985 and 1986 serum samples were collected from the Rio de Janeiro population and examined for the presence of IgG antibody to human parvovirus B19. No difference in prevalence was found between males and females. Antibody prevalence rose from 35% in children less than five years old to almost 80% in children aged eleven to fifteen years. The antibody prevalence in individuals over 50 years old was over 90%.
Resumo:
An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.