979 resultados para Cap Canaille


Relevância:

10.00% 10.00%

Publicador:

Resumo:

En Tomo V. 2 h. de grabados calcográficos representando monedas de Huesca.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter shows that apart from changes at the systemic and institutional levels, successful reform implementation struggles with a gradual change in academic beliefs, attitudes and behaviours. Currently, visions of the university proposed by the Polish academic community and visions of it proposed by Polish reformers and policymakers (within ongoing reforms) are worlds apart. I shall study recent reforms in the context of specific academic self--protective narratives being produced in the last two decades (at the collective level of the academic profession) and in the context of the Ivory Tower university ideals predominant at the individual level (as studied comparatively through a large--scale European survey of the academic profession). Institutions change both swiftly, radically – and slowly, gradually. Research literature on institutional change until recently was focused almost exclusively on the role of radical changes caused by external shocks, leading to radical institutional reconfigurations. And research literature about the gradual, incremental institutional change have been emergent for about a decade and a half now (Mahoney and Thelen 2010; Streeck and Thelen 2005, 2009; Thelen 2003). Polish higher education provides interesting empirical grounds to test institutional theories. Both types of transformations (radical and gradual) may lead to equally permanent changes in the functioning of institutions, equally deep transformations of their fundamental rules, norms and operating procedures. Questions about institutional change are questions about characteristics of institutions undergoing changes. Endogenous institutional change is as important as exogenous change (Mahoney and Thelen 2010: 3). Moments in which there emerge opportunities of performing deep institutional reforms are short (in Poland these moments occurred in 2009-2012), and between them there are long periods of institutional stasis and stability (Pierson 2004: 134-135). The premises of theories of institutional change can be applied systematically to a system of higher education which shows an unprecedented rate of change and which is exposed to broad, fundamental reform programmes. There are many ways to discuss the Kudrycka reforms - and "constructing Polish universities as organizations" (rather than traditional academic "institutions") is one of more promising. In this account, Polish universities are under construction as organizations, and under siege as institutions. They are being rationalized as organizations, following instrumental rather than institutional logics. Polish academics in their views and attitudes are still following an institutional logic, while Polish reforms are following the new (New Public Management-led) instrumental logics. Both are on a collision course about basic values. Reforms and reformees seem to be worlds apart. I am discussing the the two contrasting visions of the university and describing the Kudrycka reforms as the reistitutionalization of the research mission of Polish universities. The core of reforms is a new level of funding and governance - the intermediary one (and no longer the state one), with four new peer-run institutions, with the KEJN, PKA and NCN in the lead. Poland has been beginning to follow the "global rules of the academic game" since 2009. I am also discussing two academic self-protection modes agains reforms: (Polish) "national academic traditions" and "institutional exceptionalism" (of Polish HE). Both discourses prevailed for two decades, none seems socially (and politically) acceptable any more. Old myths do not seem to fit new realities. In this context I am discussing briefly and through large-scale empirical data the low connectedness to the outside world of Polish HE institutions, low influence of the government on HE policies and the low level of academic entrepreneurialism, as seen through the EUROAC/CAP micro-level data. The conclusion is that the Kudrycka reforms are an imporant first step only - Poland is too slow in reforms, and reforms are both underfunded and inconsistent. Poland is still accumulating disadvantages as public funding and university reforms have not reached a critical point. Ever more efforts lead to ever less results, as macro-level data show. Consequently, it may be useful to construct universities as organizations in Poland to a higher degree than elsewhere in Europe, and especially in Western Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shock wave lithotripsy is the preferred treatment modality for kidney stones in the United States. Despite clinical use for over twenty-five years, the mechanisms of stone fragmentation are still under debate. A piezoelectric array was employed to examine the effect of waveform shape and pressure distribution on stone fragmentation in lithotripsy. The array consisted of 170 elements placed on the inner surface of a 15 cm-radius spherical cap. Each element was driven independently using a 170 individual pulsers, each capable of generating 1.2 kV. The acoustic field was characterized using a fiber optic probe hydrophone with a bandwidth of 30 MHz and a spatial resolution of 100 μm. When all elements were driven simultaneously, the focal waveform was a shock wave with peak pressures p+ =65±3MPa and p−=−16±2MPa and the −6 dB focal region was 13 mm long and 2 mm wide. The delay for each element was the only control parameter for customizing the acoustic field and waveform shape, which was done with the aim of investigating the hypothesized mechanisms of stone fragmentation such as spallation, shear, squeezing, and cavitation. The acoustic field customization was achieved by employing the angular spectrum approach for modeling the forward wave propagation and regression of least square errors to determine the optimal set of delays. Results from the acoustic field customization routine and its implications on stone fragmentation will be discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rachit Agarwal, Rafael V. Martinez-Catala, Sean Harte, Cedric Segard, Brendan O'Flynn, "Modeling Power in Multi-functionality Sensor Network Applications," sensorcomm, pp.507-512, 2008 Proceedings of the Second International Conference on Sensor Technologies and Applications, August 25-August 31 2008, Cap Esterel, France

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the European Union under the Common Agricultural Policy (CAP) milk production was restricted by milk quotas since 1984. However, due to recent changes in the Common Agricultural Policy (CAP), milk quotas will be abolished by 2015. Therefore, the European dairy sector will soon face an opportunity, for the first time in a generation, to expand. Numerous studies have shown that milk production in Ireland will increase significantly post quotas (Laepple and Hennessy (2010), Donnellan and Hennessy (2007) and Lips and Reider (2005)). The research in this thesis explored milk transport and dairy product processing in the Irish dairy processing sector in the context of milk quota removal and expansion by 2020. In this study a national milk transport model was developed for the Irish dairy industry, the model was used to examine different efficiency factors in milk transport and to estimate milk transport costs post milk quota abolition. Secondly, the impact of different milk supply profiles on milk transport costs was investigated using the milk transport model. Current processing capacity in Ireland was compared against future supply, it was concluded that additional milk processing capacity would not be sufficient to process the additional milk. Thirdly, the milk transport model was used to identify the least cost locations (based on transport costs) to process the additional milk supply in 2020. Finally, an optimisation model was developed to identify the optimum configuration for the Irish dairy processing sector in 2020 taking cognisance of increasing transport costs and decreasing processing costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecular tunnel junctions involve studying the behaviour of a single molecule sandwiched between metal leads. When a molecule makes contact with electrodes, it becomes open to the environment which can heavily influence its properties, such as electronegativity and electron transport. While the most common computational approaches remain to be single particle approximations, in this thesis it is shown that a more explicit treatment of electron interactions can be required. By studying an open atomic chain junction, it is found that including electron correlations corrects the strong lead-molecule interaction seen by the ΔSCF approximation, and has an impact on junction I − V properties. The need for an accurate description of electronegativity is highlighted by studying a correlated model of hexatriene-di-thiol with a systematically varied correlation parameter and comparing the results to various electronic structure treatments. The results indicating an overestimation of the band gap and underestimation of charge transfer in the Hartree-Fock regime is equivalent to not treating electron-electron correlations. While in the opposite limit, over-compensating for electron-electron interaction leads to underestimated band gap and too high an electron current as seen in DFT/LDA treatment. It is emphasised in this thesis that correcting electronegativity is equivalent to maximising the overlap of the approximate density matrix to the exact reduced density matrix found at the exact many-body solution. In this work, the complex absorbing potential (CAP) formalism which allows for the inclusion metal electrodes into explicit wavefunction many-body formalisms is further developed. The CAP methodology is applied to study the electron state lifetimes and shifts as the junction is made open.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mercury is a potent neurotoxin even at low concentrations. The unoxidised metal has a high vapour pressure and can circulate through the atmosphere, but when oxidised can deposit and be accumulated through the food chain. This work aims to investigate the oxidation processes of atmospheric Hg0(g). The first part describes efforts to make a portable Hg sensor based on Cavity Enhanced Absorption Spectroscopy (CEAS). The detection limit achieved was 66 ngm−3 for a 10 second averaging time. The second part of this work describes experiments carried out in a temperature controlled atmospheric simulation chamber in the Desert Research Institute, Reno, Nevada, USA. The chamber was built around an existing Hg CRDS system that could measure Hg concentrations in the chamber of<100 ngm−3 at 1 Hz enabling reactions to be followed. The main oxidant studied was bromine, which was quantified with a LED based CEAS system across the chamber. Hg oxidation in the chamber was found to be mostly too slow for current models to explain. A seven reaction model was developed and tested to find which parameters were capable of explaining the deviation. The model was overdetermined and no unique solution could be found. The most likely possibility was that the first oxidation step Hg + Br →HgBr was slower than the preferred literature value by a factor of two. However, if the more uncertain data at low [Br2] was included then the only parameter that could explain the experiments was a fast, temperature independent dissociation of HgBr some hundreds of times faster than predicted thermolysis or photolysis rates. Overall this work concluded that to quantitatively understand the reaction of Hg with Br2, the intermediates HgBr and Br must be measured. This conclusion will help to guide the planning of future studies of atmospheric Hg chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The etiologic diagnosis of community-acquired pneumonia (CAP) remains challenging in children because blood cultures have low sensitivity. Novel approaches are needed to confirm the role of Streptococcus pneumoniae. METHODS: In this study, pneumococcal aetiology was determined by serology using a subset of blood samples collected during a prospective multicentre observational study of children <15 years of age hospitalised in Belgium with X-ray-confirmed CAP. Blood samples were collected at admission and 3-4 weeks later. Pneumococcal (P)-CAP was defined in the presence of a positive blood or pleural fluid culture. Serotyping of Streptococcus pneumoniae isolates was done with the Quellung reaction. Serological diagnosis was assessed for nine serotypes using World Health Organization validated IgG and IgA serotype-specific enzyme-linked immunosorbent assays (ELISAs). RESULTS: Paired admission/convalescent sera from 163 children were evaluated by ELISA (35 with proven P-CAP and 128 with non proven P-CAP). ELISA detected pneumococci in 82.8% of patients with proven P-CAP. The serotypes identified were the same as with the Quellung reaction in 82% and 59% of cases by IgG ELISA and IgA ELISA, respectively. Overall, ELISA identified a pneumococcal aetiology in 55% of patients with non-proven P-CAP. Serotypes 1 (51.6%), 7F (19%), and 5 (15.7%) were the most frequent according to IgG ELISA. CONCLUSIONS: In conclusion, the serological assay allows recognition of pneumococcal origin in 55% of CAP patients with negative culture. This assay should improve the diagnosis of P-CAP in children and could be a useful tool for future epidemiological studies on childhood CAP etiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Following the completion of a 20-week, open-label study of the safety and efficacy of liquid rivastigmine for adolescents with Down syndrome, 5 of the 10 adolescents in the clinical trial continued long-term rivastigmine therapy and 5 did not. After an average period of 38 months, all 10 subjects returned for a follow-up assessment to determine the safety and efficacy of long-term rivastigmine use. Rivastigmine was well tolerated and overall health appeared to be unaffected by long-term rivastigmine use. Performance change on cognitive and language measures administered at the termination of the open-label clinical trial was compared between the two groups. No between-group difference in median performance change across the long-term period was found, suggesting that the long-term use of rivastigmine does not improve cognitive and language performance. However, two subjects demonstrated remarkable improvement in adaptive function over the long-term period. Both subjects had received long-term rivastigmine therapy. The discussion addresses the challenge of assessing cognitive change in clinical trials using adolescents with Down syndrome as subjects and the use of group versus individual data to evaluate the relevance of medication effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In addition to modulating the function and stability of cellular mRNAs, microRNAs can profoundly affect the life cycles of viruses bearing sequence complementary targets, a finding recently exploited to ameliorate toxicities of vaccines and oncolytic viruses. To elucidate the mechanisms underlying microRNA-mediated antiviral activity, we modified the 3' untranslated region (3'UTR) of Coxsackievirus A21 to incorporate targets with varying degrees of homology to endogenous microRNAs. We show that microRNAs can interrupt the picornavirus life-cycle at multiple levels, including catalytic degradation of the viral RNA genome, suppression of cap-independent mRNA translation, and interference with genome encapsidation. In addition, we have examined the extent to which endogenous microRNAs can suppress viral replication in vivo and how viruses can overcome this inhibition by microRNA saturation in mouse cancer models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seminal work by Weitzman (1974) revealed prices are preferred to quantities when marginal benefits are relatively flat compared to marginal costs. We extend this comparison to indexed policies, where quantities are proportional to an index, such as output. We find that policy preferences hinge on additional parameters describing the first and second moments of the index and the ex post optimal quantity level. When the ratio of these variables' coefficients of variation divided by their correlation is less than approximately two, indexed quantities are preferred to fixed quantities. A slightly more complex condition determines when indexed quantities are preferred to prices. Applied to climate change policy, we find that the range of variation and correlation in country-level carbon dioxide emissions and GDP suggests the ranking of an emissions intensity cap (indexed to GDP) compared to a fixed emission cap is not uniform across countries; neither policy clearly dominates the other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prostate growth is dependent on circulating androgens, which can be influenced by hepatic function. Liver disease has been suggested to influence prostate cancer (CaP) incidence. However, the effect of hepatic function on CaP outcomes has not been investigated. A total of 1181 patients who underwent radical prostatectomy (RP) between 1988 and 2008 at four Veterans Affairs hospitals that comprise the Shared Equal Access Regional Cancer Hospital database and had available liver function test (LFT) data were included in the study. Independent associations of LFTs with unfavorable pathological features and biochemical recurrence were determined using logistic and Cox regression analyses. Serum glutamic oxaloacetic transaminase (SGOT) and serum glutamic pyruvic transaminase (SGPT) levels were elevated in 8.2 and 4.4% of patients, respectively. After controlling for CaP features, logistic regression revealed a significant association between SGOT levels and pathological Gleason sum > or =7(4+3) cancer (odds ratio=2.12; 95% confidence interval=1.11-4.05; P=0.02). Mild hepatic dysfunction was significantly associated with adverse CaP grade, but was not significantly associated with other adverse pathological features or biochemical recurrence in a cohort of men undergoing RP. The effect of moderate-to-severe liver disease on disease outcomes in CaP patients managed non-surgically remains to be investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our long-term goal is the detection and characterization of vulnerable plaque in the coronary arteries of the heart using intravascular ultrasound (IVUS) catheters. Vulnerable plaque, characterized by a thin fibrous cap and a soft, lipid-rich necrotic core is a precursor to heart attack and stroke. Early detection of such plaques may potentially alter the course of treatment of the patient to prevent ischemic events. We have previously described the characterization of carotid plaques using external linear arrays operating at 9 MHz. In addition, we previously modified circular array IVUS catheters by short-circuiting several neighboring elements to produce fixed beamwidths for intravascular hyperthermia applications. In this paper, we modified Volcano Visions 8.2 French, 9 MHz catheters and Volcano Platinum 3.5 French, 20 MHz catheters by short-circuiting portions of the array for acoustic radiation force impulse imaging (ARFI) applications. The catheters had an effective transmit aperture size of 2 mm and 1.5 mm, respectively. The catheters were connected to a Verasonics scanner and driven with pushing pulses of 180 V p-p to acquire ARFI data from a soft gel phantom with a Young's modulus of 2.9 kPa. The dynamic response of the tissue-mimicking material demonstrates a typical ARFI motion of 1 to 2 microns as the gel phantom displaces away and recovers back to its normal position. The hardware modifications applied to our IVUS catheters mimic potential beamforming modifications that could be implemented on IVUS scanners. Our results demonstrate that the generation of radiation force from IVUS catheters and the development of intravascular ARFI may be feasible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Community-acquired pneumonia (CAP) is a major cause of morbidity in children. This study estimated the proportion of children with pneumococcal CAP among children hospitalised with CAP in Belgium and describes the causative serotype distribution after implementation of the 7-valent pneumococcal conjugate vaccine. Children 0-14 years hospitalised with X-ray-confirmed CAP were prospectively enrolled in a multicentre observational study. Acute and convalescent blood samples were collected. Pneumococcal aetiology was assessed by conventional methods (blood or pleural fluid cultures with Quellung reaction capsular typing or polymerase chain reaction [PCR] in pleural fluid), and recently developed methods (real-time PCR in blood and World Health Organization-validated serotype-specific serology). A total of 561 children were enrolled. Pneumococcal aetiology was assessed by conventional methods in 539, serology in 171, and real-time PCR in blood in 154. Pneumococcal aetiology was identified in 12.2% (66/539) of the children by conventional methods alone but in 73.9% by the combination of conventional and recently developed methods. The pneumococcal detection rate adjusted for the whole study population was 61.7%. Serotypes 1 (42.3%), 5 (16.0%), and 7F(7A) (12.8%) were predominant. In conclusion, Streptococcus pneumoniae remains the predominant bacteria in children hospitalised for CAP in Belgium after implementation of 7-valent pneumococcal conjugate vaccine, with non-vaccine-serotypes accounting for the majority of cases. The use of recently developed methods improves diagnosis of pneumococcal aetiology.