984 resultados para Calibration phantom
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
OBJECTIVE: To evaluate the sphygmomanometers calibration accuracy and the physical conditions of the cuff-bladder, bulb, pump, and valve. METHODS: Sixty hundred and forty five aneroid sphygmomanometers were evaluated, 521 used in private practice and 124 used in hospitals. Aneroid manometers were tested against a properly calibrated mercury manometer and were considered calibrated when the error was <=3mm Hg. The physical conditions of the cuffs-bladder, bulb, pump, and valve were also evaluated. RESULTS: Of the aneroid sphygmomanometers tested, 51% of those used in private practice and 56% of those used in hospitals were found to be not accurately calibrated. Of these, the magnitude of inaccuracy ranged from 4 to 8mm Hg in 70% and 51% of the devices, respectively. The problems found in the cuffs - bladders, bulbs, pumps, and valves of the private practice and hospital devices were bladder damage (34% vs. 21%, respectively), holes/leaks in the bulbs (22% vs. 4%, respectively), and rubber aging (15% vs. 12%, respectively). Of the devices tested, 72% revealed at least one problem interfering with blood pressure measurement accuracy. CONCLUSION: Most of the manometers evaluated, whether used in private practice or in hospitals, were found to be inaccurate and unreliable, and their use may jeopardize the diagnosis and treatment of arterial hypertension.
Resumo:
Dissertação de mestrado em Técnicas de Caracterização e Análise Química
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
Researches point out that the pupil diameter is a sign for fatigue calibration. In this study, we try to analyze how, through a more complex task of air traffic control, the participants will show a bigger pupil diameter than in tasks of easier air traffic control. Likewise, as the theories that go in line with compensatory mechanisms assume, if the job/task requires it, new resources may be provided to continue its execution. The sample had 61 participants, and two variables were manipulated: traffic density on condition many aircrafts and few aircrafts. And the other variable was the time on the task with 5 minute intervals for 2 hours (23 intervals). The dependent variable was the pupil diameter. The results showed that participants who performed the most complex task had bigger pupil diameter. At the same time, they showed that more activity of the participant, major would be the diameter pupilar. Also, the variable TOT (Time Of Task) showed that the pupil diminished, and then it continued increasing due to a generation of new resources.
Resumo:
The sample under investigation in this project is an experimental chromium enriched yeast used as a possible additive in animal foodstuff, which was produced by growing yeast in the presence of chromium (III) chloride. Chromium on its own in not biologically active but chromium in the form of chromium enriched yeast is biologically active. The objective of this project was to show the complete absence of chromium(VI) from the sample. A literature survey describing previous work carried out on the speciation of Cr(VI) has been carried out. The principal methods of detection of Cr(VI) used in this project are Polarography, G.F.A.A. Spectroscopy, U.V. Spectroscopy and H.P.L.C. For each of the above methods a calibration curve was obtained and each method was applied to the yeast extract. The H.P.L.C. and U.V. spectroscopic method are specific for Cr(VI) but polarography and G.F.A.A. spectroscopy measure total chromium. Tris-NaOH buffer has been investigated for the extraction of chromium(VT). Problems associated with air oxidation of Cr(III) in alkaline solution have identified and procedures described for the suppression of air oxidation. Procedures are described for the application of the extraction procedure to the yeast extract and for the determination of Cr(VI) in the extract. Procedures are also described for the preconcentration of Cr(VI) on a HPLC column and for the application to the yeast extract. The rate of reduction of Cr(VI) by ascorbic acid is investigated and found to be first order with respect to ascorbic acid concentration. The reduction capacity of the yeast is also investigated and it was found that in acid solution the yeast will reduce Cr(VI) but in neutral or basic solution the reduction capacity is diminished. Conclusions regarding the objectives of the project are drawn and suggestions for further work are given.
Resumo:
Ground-based measurements of the parameters of atmosphere in Tbilisi during the same period, which are provided by the Mikheil Nodia Institute of geophysics, were used as calibration data. Satellite data monthly averaging, preprocessing, analysis and visualization was performed using Giovanni web-based application. Maps of trends and periodic components of the atmosphere aerosol optical thickness and ozone concentration over the study area were calculated.
Resumo:
TPD, TDS, termal desorption, hydrogen isotopes, graphite, calibration, QMS
Resumo:
Background: The TIMI Score for ST-segment elevation myocardial infarction (STEMI) was created and validated specifically for this clinical scenario, while the GRACE score is generic to any type of acute coronary syndrome. Objective: Between TIMI and GRACE scores, identify the one of better prognostic performance in patients with STEMI. Methods: We included 152 individuals consecutively admitted for STEMI. The TIMI and GRACE scores were tested for their discriminatory ability (C-statistics) and calibration (Hosmer-Lemeshow) in relation to hospital death. Results: The TIMI score showed equal distribution of patients in the ranges of low, intermediate and high risk (39 %, 27 % and 34 %, respectively), as opposed to the GRACE Score that showed predominant distribution at low risk (80 %, 13 % and 7%, respectively). Case-fatality was 11%. The C-statistics of the TIMI score was 0.87 (95%CI = 0.76 to 0.98), similar to GRACE (0.87, 95%CI = 0.75 to 0.99) - p = 0.71. The TIMI score showed satisfactory calibration represented by χ2 = 1.4 (p = 0.92), well above the calibration of the GRACE score, which showed χ2 = 14 (p = 0.08). This calibration is reflected in the expected incidence ranges for low, intermediate and high risk, according to the TIMI score (0 %, 4.9 % and 25 %, respectively), differently to GRACE (2.4%, 25% and 73%), which featured middle range incidence inappropriately. Conclusion: Although the scores show similar discriminatory capacity for hospital death, the TIMI score had better calibration than GRACE. These findings need to be validated populations of different risk profiles.
Resumo:
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.
Resumo:
AbstractBackground:Risk scores for cardiac surgery cannot continue to be neglected.Objective:To assess the performance of “Age, Creatinine and Ejection Fraction Score” (ACEF Score) to predict mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery, and to compare it to other scores.Methods:A prospective cohort study was carried out with the database of a Brazilian tertiary care center. A total of 2,565 patients submitted to elective surgeries between May 2007 and July 2009 were assessed. For a more detailed analysis, the ACEF Score performance was compared to the InsCor’s and EuroSCORE’s performance through correlation, calibration and discrimination tests.Results:Patients were stratified into mild, moderate and severe for all models. Calibration was inadequate for ACEF Score (p = 0.046) and adequate for InsCor (p = 0.460) and EuroSCORE (p = 0.750). As for discrimination, the area under the ROC curve was questionable for the ACEF Score (0.625) and adequate for InsCor (0.744) and EuroSCORE (0.763).Conclusion:Although simple to use and practical, the ACEF Score, unlike InsCor and EuroSCORE, was not accurate for predicting mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery in a Brazilian tertiary care center. (Arq Bras Cardiol. 2015; [online].ahead print, PP.0-0)
Resumo:
Abstract Background: The revascularization strategy of the left main disease is determinant for clinical outcomes. Objective: We sought to 1) validate and compare the performance of the SYNTAX Score 1 and 2 for predicting major cardiovascular events at 4 years in patients who underwent unprotected left main angioplasty and 2) evaluate the long-term outcome according to the SYNTAX score 2-recommended revascularization strategy. Methods: We retrospectively studied 132 patients from a single-centre registry who underwent unprotected left main angioplasty between March 1999 and December 2010. Discrimination and calibration of both models were assessed by ROC curve analysis, calibration curves and the Hosmer-Lemeshow test. Results: Total event rate was 26.5% at 4 years.The AUC for the SYNTAX Score 1 and SYNTAX Score 2 for percutaneous coronary intervention, was 0.61 (95% CI: 0.49-0.73) and 0.67 (95% CI: 0.57-0.78), respectively. Despite a good overall adjustment for both models, the SYNTAX Score 2 tended to underpredict risk. In the 47 patients (36%) who should have undergone surgery according to the SYNTAX Score 2, event rate was numerically higher (30% vs. 25%; p=0.54), and for those with a higher difference between the two SYNTAX Score 2 scores (Percutaneous coronary intervention vs. Coronary artery by-pass graft risk estimation greater than 5.7%), event rate was almost double (40% vs. 22%; p=0.2). Conclusion: The SYNTAX Score 2 may allow a better and individualized risk stratification of patients who need revascularization of an unprotected left main coronary artery. Prospective studies are needed for further validation.
Resumo:
Urinary determinations of riboflavine were done with the methods of Emmerie, Ferrebee and Najjar. Recovery experiments gave better results with the method of Ferrebee and the modification of Najjar. Some details are presented and calibration curves are constructed for the use of the Pulfrich fotometer and the pfalz and Bauer fluorphotometer. In two normal cases it was observed that the excretion of riboflavine is great after 2 to 5hs of the injection of 1mg. of synthetic riboflavine. Normal cases excreted in an adequate diet 12 to 145 microg. of riboflavine per 100cc. of urine and 76 to 1300 microg. per day.
Resumo:
Recently there has been a renewed research interest in the properties of non survey updates of input-output tables and social accounting matrices (SAM). Along with the venerable and well known scaling RAS method, several alternative new procedures related to entropy minimization and other metrics have been suggested, tested and used in the literature. Whether these procedures will eventually substitute or merely complement the RAS approach is still an open question without a definite answer. The performance of many of the updating procedures has been tested using some kind of proximity or closeness measure to a reference input-output table or SAM. The first goal of this paper, in contrast, is the proposal of checking the operational performance of updating mechanisms by way of comparing the simulation results that ensue from adopting alternative databases for calibration of a reference applied general equilibrium model. The second goal is to introduce a new updatin! g procedure based on information retrieval principles. This new procedure is then compared as far as performance is concerned to two well-known updating approaches: RAS and cross-entropy. The rationale for the suggested cross validation is that the driving force for having more up to date databases is to be able to conduct more current, and hopefully more credible, policy analyses.