970 resultados para Blood sugar monitoring.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZigBee-based Remote Patient Monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic diversity in a collection of 64 sugar apple accessions collected from different municipalities in northern Minas Gerais was assessed by RAPD analysis. Using 20 selected RAPD primers 167 fragments were generated, of which 48 were polymorphic (28.7%) producing an average of 2.4 polymorphic fragments per primer. Low percentage of polymorphism (< 29%) was observed by using the set of primers indicating low level of genetic variation among the 64 accessions evaluated. Genetic relationships were estimated using Jaccard's coefficient of similarity. Accessions from different municipalities clustered together indicating no correlation between molecular grouping and geographical origin. The dendrogram revealed five clusters. The first cluster grouped C19 and G29 accessions collected from the municipalities of Verdelândia and Monte Azul, respectively. The second cluster grouped G16 and B11 accessions collected from the municipalities of Monte Azul and Coração de Jesus, respectively. The remaining accessions were grouped in three clusters, with 8, 15 and 37 accessions, respectively. In summary, RAPD showed a low percentage of polymorphism in the germplasm collection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Large salty areas in the Brazilian semi-arid region have limited farming in Northeastern Brazil. One example is the sugar cane cultivation, which reinforces the need of selecting varieties that are more tolerant to salinity. The objective of this study was to evaluate the effect of salinity on growth of ten varieties of sugar cane. The experiment was conducted in a greenhouse, set in the experimental field of Embrapa Semiárido, in Petrolina, Pernambuco State. The experimental design was randomized blocks arranged in a 6 X 10 factorial arrangement, comprised of six levels of salinity (0, 1.0, 2.0, 4.0, 6.0 and 8.0 dS m-1) and ten sugar cane varieties (VAT 90212; RB 72454; RB 867515; Q 124; RB 961003; RB 957508; SP791011; RB 835089; RB 92579 and SP 943206). Salt levels of irrigation water were obtained by adding NaCl, CaCl2.2H2O and MgSO4.7H2O to achieve an equivalent ratio among Na:Ca:Mg of 7:2:1. Sixty days later, plant height, stem diameter (base), number of leaves, stalks and sprouts, leaf area and fresh and dry mass of the aerial part and roots were all measured. The varieties of sugar cane showed similar responses for growth reduction as soil salinity increases, being considered moderately sensitive to salinity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association of cigarette smoking, physical activity at work, and social class with total cholesterol and with high and low density lipoprotein cholesterol were examined in a random sample of 238 males, of 18 years of age, of Rosario, Argerntina. The mean (mg/dl) total serum cholesterol of the whole sample was 174.7, the high density lipoprotein cholesterol 52.8, and the low density lipoprotein cholesterol 121.5. Black tobacco consumers, evenly distributed by social class, had higher levels of total and low density lipoprotein cholesterol. Total cholesterol was higher in the high social class, differently from what smokers' distribution by social class, would lead one to expect. While a highly negative association was found between social class and physical activity at work, there were no significant diferences in lipoprotein levels between manual and non-manual workers. It is possible that the nutritional differences by social class still prevail over the smoking habit in their influence on the lipoprotein levels in these subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Populations of Anopheles (Kerteszia) were sampled fortnightly over a one-year period (August 1991 to July 1992) at Ribeira Valley, S. Paulo State, Brazil. Indoor and outdoor collections were made on human bait at evening crepuscular period. The Polovodova technique for age grading was applied to 3,501 females of Anopheles cruzii and to 416 females of An. bellator. That sample represented 34.4% of the total number of mosquitoes collected. The most abundant species found was An. cruzii. However, An. bellator showed an endophagy that was almost three times greater than that of An. cruzii. The overall parous rate was 25.4% and uniparity was practically dominant one. A proportion of 26.9% of An. cruzii and 12.0% of An. bellator were found to be uniparous. Only three outdoor females of the former species (0.1%) showed biparity. Parity of An. cruzii was higher in females caught outdoors than in those caught indoors. Nevertheless, 497 nulliparous females examined (417 cruzii and 80 bellator) had ovaries that had advanced to Christophers and Mer stages III to V. These results imply that these females had already practised hematophagy. Relating these results to those from the parous females, a high statistical significance was found, leading to the conclusion that gonothophic discordance is a common pattern among these anophelines. Further, these results obtained with human bait catches strongly suggest that nearly 38.0% of these host-seeking females had already taken at least one previous blood-meal. So it is possible that enough time could thus be available for the plasmodian development in the vectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde (CH2O) the most simple and reactive of all aldehydes, is a colorless, reactive and readily polymerizing gas at normal temperature. It has a pungent, suffocating odour that is recognized by most human subjects at concentrations below 1 ppm. According to the Report on Carcinogens, formaldehyde (FA) ranks 25th in the overall U.S. chemical production with more than 11 billion pounds (5 million tons) produced each year. Is an important industrial compound that is used in the manufacture of synthetic resins and chemical compounds such as lubricants and adhesives. It has also applications as a disinfectant, preservative and is used in cosmetics. Estimates of the number of persons who are occupationally exposed to FA indicate that, at least at low levels, may occur in a wide variety of industries. The occupational settings with most extensive use of formaldehyde is in the production of resins and in anatomy and pathology laboratories. Several studies reported a carcinogenic effect in humans after inhalation of FA, in particular an increased risk for nasopharyngeal cancer. Nowadays, the International Agency for Research on Cancer (IARC) classifies FA as carcinogenic to humans (group 1), on the basis of sufficient evidence in humans and sufficient evidence in experimental animals. Manifold in vitro studies clearly indicated that FA is genotoxic. FA induced various genotoxic effects in proliferatin cultured mammalian cells. A variety of evidence suggests that the primary DNA alterations after FA exposure are DNA-protein crosslinks (DPX). Incomplete repair of DPX can lead to the formation of mutations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An. (Ker.) cruzii and An. (Ker.) bellator were monitored by the use of human bait and Shannon trap collections during a one-year period in 1994. Indoor and outdoor collections were made on human bait and inside the forest environment a Shannon trap was used. Both were undertaken in the evening crepuscular period. Results showed a greater abundance of An. cruzii in the forest, where as An. bellator was more abundant in the domiciliary environment. Through the application of the Polovodova method an age grading was established. Computing the parous and nulliparous females with Christopher's Stage III and above, more than 30.0% of blood-seeking specimens of both anophelines had had a previous blood meal. The higher abundance of An. bellator as compared with that of An. cruzii in the domiciliary environment may be explained by the influence of the neighboring low-lying coastal islands of the estuary system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure assessment is an important step of risk assessment process and has evolved more quickly than perhaps any aspect of the four-step risk paradigm (hazard identification, exposure assessment, dose-response analysis, and risk characterization). Nevertheless, some epidemiological studies have associated adverse health effects to a chemical exposure with an inadequate or absent exposure quantification. In addition to the metric used, the truly representation of exposure by measurements depends on: the strategy of sampling, random collection of measurements, and similarity between the measured and unmeasured exposure groups. Two environmental monitoring methodologies for formaldehyde occupational exposure were used to assess the influence of metric selection in exposure assessment and, consequently, in risk assessment process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malaria, caused by Plasmodium falciparum (P. falciparum), ranks as one of the most baleful infectious diseases worldwide. New antimalarial treatments are needed to face existing or emerging drug resistant strains. Protein degradation appears to play a significant role during the asexual intraerythrocytic developmental cycle (IDC) of P. falciparum. Inhibition of the ubiquitin proteasome system (UPS), a major intracellular proteolytic pathway, effectively reduces infection and parasite replication. P. falciparum and erythrocyte UPS coexist during IDC but the nature of their relationship is largely unknown. We used an approach based on Tandem Ubiquitin-Binding Entities (TUBEs) and 1D gel electrophoresis followed by mass spectrometry to identify major components of the TUBEs-associated ubiquitin proteome of both host and parasite during ring, trophozoite and schizont stages. Ring-exported protein (REX1), a P. falciparum protein located in Maurer's clefts and important for parasite nutrient import, was found to reach a maximum level of ubiquitylation in trophozoites stage. The Homo sapiens (H. sapiens) TUBEs associated ubiquitin proteome decreased during the infection, whereas the equivalent P. falciparum TUBEs-associated ubiquitin proteome counterpart increased. Major cellular processes such as DNA repair, replication, stress response, vesicular transport and catabolic events appear to be regulated by ubiquitylation along the IDC P. falciparum infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O formaldeído (FA) foi classificado, em 2004, pela International Agency for Cancer Research como agente cancerígeno. Este agente químico ocupa a 25ª posição em toda a produção química dos Estados Unidos da América, com mais de 5 milhões de toneladas produzidas por ano. Devido à sua importância económica e uso diversificado, muitos indivíduos estão expostos profissionalmente a FA. Com o estudo desenvolvido pretendeu‑se avaliar a exposição a FA em dois contextos ocupacionais distintos – na produção de FA e resinas e em laboratórios de anatomia patológica (AP) e relacionar com eventuais efeitos para a saúde, comparando a frequência de micronúcleos (MN) em linfócitos do sangue periférico e em células esfoliadas da mucosa bucal dos trabalhadores expostos a FA com indivíduos não expostos (controlos). Como amostra foram estudados 80 trabalhadores ocupacionalmente expostos a FA: 30 trabalhadores da fábrica de produção de FA e resinas e 50 trabalhadores de 10 laboratórios de AP. Foi constituído um grupo controlo de 85 indivíduos com atividades profissionais que não envolviam a exposição a formaldeído ou qualquer outro agente químico com propriedades genotóxicas. Aplicaram‑se duas metodologias distintas de avaliação ambiental do FA com o objetivo de conhecer a exposição profissional. Compararam‑se os resultados obtidos com os valores limite para a exposição média ponderada (TLV‑TWA=0,75 ppm) e para a concentração máxima (VLE‑CM=0,3 ppm). A totalidade dos laboratórios apresentou resultados superiores ao valor de referência existente para a concentração máxima. Nenhum dos resultados obtidos para a exposição média ponderada foi superior ao valor de referência. O exame macroscópico obteve os valores das concentrações máximas mais elevadas em 90% dos laboratórios. Os valores de MN foram mais elevados nos indivíduos expostos a FA comparativamente com os controlos. No caso dos MN nos linfócitos, a média foi de 3,96 nos expostos e de 0,81 nos não expostos. Os MN nas células esfoliadas da boca apresentaram uma média de 0,96 nos expostos e de 0,16 nos controlos. Os resultados obtidos nesta acção de biomonitorização podem revelar‑se particularmente úteis para as organizações responsáveis em definir os níveis aceitáveis para a exposição humana a FA. ABSTRACT: Since 2004, formaldehyde (FA) has been classified by the International Agency for Cancer Research as a carcinogen. The FA ranks 25th in the overall United States chemical production, with more than 5 million tons produced each year. Due to its economic importance and varied use, many individuals are exposed to FA at their occupational settings. This study aimed to assess the exposure to FA in two occupational settings – FA production factory and pathology anatomy (PA) laboratories – and relate it to possible health effects by comparing frequency of micronuclei (MN) in peripheral blood lymphocytes and exfoliated cells from the oral mucosa of workers exposed to FA with individuals not exposed to this agent (controls). This study was performed in 80 workers occupationally exposed to FA: 30 workers of the FA factory and 50 workers in 10 PA laboratories. The control group comprised 85 subjects without exposure. We have applied two different methodologies for environmental monitoring of FA. The results were compared with the reference to the exposure weighted average (TLV‑TWA = 0.75 ppm) and ceiling concentration (VLE‑MC = 0.3 ppm). All laboratories had results higher than the reference value to CM (1.41 ppm). None of the results obtained for the TWA exposure (0.16 ppm) were higher than the reference value. Macroscopic examination obtained the highest values of CM in 90% of laboratories. MN values were higher in individuals exposed to FA as compared to controls. As for MN in lymphocytes, the average was 3.96 in exposed compared with 0.81 in the unexposed. The MN in exfoliated cells of the buccal mucosa had an average of 0.96 in exposed, compared with 0.16 in controls. The results of this biomonitoring can be particularly useful to organizations responsible for defining acceptable levels for human exposure to FA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM(2.5) and PM(10) patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 µm(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.