942 resultados para Acute myocardial infarction (AMI)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background In patients presenting with acute cardiac symptoms, abnormal ECG and raised troponin, myocarditis may be suspected after normal angiography. Aims To analyse cardiac magnetic resonance (CMR) findings in patients with a provisional diagnosis of acute coronary syndrome (ACS) in whom acute myocarditis was subsequently considered more likely. Methods and results 79 patients referred for CMR following an admission with presumed ACS and raised serum troponin in whom no culprit lesion was detected were studied. 13% had unrecognised myocardial infarction and 6% takotsubo cardiomyopathy. The remainder (81%) were diagnosed with myocarditis. Mean age was 45615 years and 70% were male. Left ventricular ejection fraction (EF) was 58610%; myocardial oedema was detected in 58%. A myocarditic pattern of late gadolinium enhancement (LGE) was detected in 92%. Abnormalities were detected more frequently in scans performed within 2 weeks of symptom onset: oedema in 81% vs 11% (p<0.0005), and LGE in 100% vs 76% (p<0.005). In 20 patients with both an acute (<2 weeks) and convalescent scan (>3 weeks), oedema decreased from 84% to 39% (p<0.01) and LGE from 5.6 to 3.0 segments (p¼0.005). Three patients presented with sustained ventricular tachycardia, another died suddenly 4 days after admission and one resuscitated 7 weeks following presentation. All 5 patients had preserved EF. Conclusions Our study emphasises the importance of access to CMR for heart attack centres. If myocarditis is suspected, CMR scanning should be performed within 14 days. Myocarditis should not be regarded as benign, even when EF is preserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS: We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION: In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING: Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: There is no strong evidence that all ischaemic stroke types are associated with high cardiovascular risk. Our aim was to investigate whether all ischaemic stroke types are associated with high cardiovascular risk. METHODS: All consecutive patients with ischaemic stroke registered in the Athens Stroke Registry between 1 January 1993 and 31 December 2010 were categorized according to the TOAST classification and were followed up for up to 10 years. Outcomes assessed were cardiovascular and all-cause mortality, myocardial infarction, stroke recurrence, and a composite cardiovascular outcome consisting of myocardial infarction, angina pectoris, acute heart failure, sudden cardiac death, stroke recurrence and aortic aneurysm rupture. The Kaplan-Meier product limit method was used to estimate the probability of each end-point in each patient group. Cox proportional hazards models were used to determine the independent covariates of each end-point. RESULTS: Two thousand seven hundred and thirty patients were followed up for 48.1 ± 41.9 months. The cumulative probabilities of 10-year cardiovascular mortality in patients with cardioembolic stroke [46.6%, 95% confidence interval (CI) 40.6-52.8], lacunar stroke (22.1%, 95% CI 16.2-28.0) or undetermined stroke (35.2%, 95% CI 27.8-42.6) were either similar to or higher than those of patients with large-artery atherosclerotic stroke (LAA) (28.7%, 95% CI 22.4-35.0). Compared with LAA, all other TOAST types had a higher probability of 10-year stroke recurrence. In Cox proportional hazards analysis, compared with patients with LAA, patients with any other stroke type were associated with similar or higher risk for the outcomes of overall mortality, cardiovascular mortality, stroke recurrence and composite cardiovascular outcome. CONCLUSIONS: Large-artery atherosclerotic stroke and cardioembolic stroke are associated with the highest risk for future cardiovascular events, with the latter carrying at least as high a risk as LAA stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosis that had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The radial artery is routinely used as a graft for surgical arterial myocardial revascularization. The proximal radial artery anastomosis site remains unknown. In this study, we analyzed the short-term results and the operative risk determinants after having used four different common techniques for radial artery implantation. METHODS: From January 2000 to December 2004, 571 patients underwent coronary artery bypass grafting with radial arteries. Data were analyzed for the entire population and for subgroups following the proximal radial artery anastomosis site: 140 T-graft with the mammary artery (group A), 316 free-grafts with the proximal anastomosis to the ascending aorta (group B), 55 mammary arteries in situ elongated with the radial artery (group C) and 60 radial arteries elongated with a piece of mammary artery and anastomosed to the ascending aorta (group D). RESULTS: The mean age was 53.8 +/- 7.7 years; 55.5% of patients had a previous myocardial infarction and 73% presented with a satisfactory left ventricular function. A complete arterial myocardial revascularization was achieved in 532 cases (93.2%) and 90.2% of the procedures were performed under cardiopulmonary bypass and cardioplegic arrest. The operative mortality rate was 0.9%, a postoperative myocardial infarction was diagnosed in 19 patients (3.3%), an intra-aortic balloon pump was used in 10 patients (1.7%) and a mechanical circulatory device was implanted in 2 patients. The radial artery harvesting site remained always free from complications. The proximal radial artery anastomosis site was not a determinant of early hospital mortality. Group C showed a higher risk of postoperative myocardial infarction (p = 0.09), together with female gender (p = 0.003), hypertension (p = 0.059) and a longer cardiopulmonary bypass time. CONCLUSIONS: The radial artery and the mammary artery can guarantee multiple arterial revascularization also for patients with contraindications to double mammary artery use. The four most common techniques for proximal radial artery anastomosis are not related to a higher operative risk and they can be used alternatively to reach the best surgical results

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: A new magnetic resonance imaging approach for detection of myocardial late enhancement during free-breathing was developed. METHODS AND RESULTS: For suppression of respiratory motion artifacts, a prospective navigator technology including real-time motion correction and a local navigator restore was implemented. Subject specific inversion times were defined from images with incrementally increased inversion times acquired during a single dynamic scout navigator-gated and real-time motion corrected free-breathing scan. Subsequently, MR-imaging of myocardial late enhancement was performed with navigator-gated and real-time motion corrected adjacent short axis and long axis (two, three and four chamber) views. This alternative approach was investigated in 7 patients with history of myocardial infarction 12 min after i. v. administration of 0.2 mmol/kg body weight gadolinium-DTPA. CONCLUSION: With the presented navigator-gated and real-time motion corrected sequence for MR-imaging of myocardial late enhancement data can be completely acquired during free-breathing. Time constraints of a breath-hold technique are abolished and optimized patient specific inversion time is ensured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population. DESIGN: The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years. CONCLUSION: The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to assess the safety of the concurrent administration of a clopidogrel and prasugrel loading dose in patients undergoing primary percutaneous coronary intervention. BACKGROUND: Prasugrel is one of the preferred P2Y12 platelet receptor antagonists for ST-segment elevation myocardial infarction patients. The use of prasugrel was evaluated clinically in clopidogrel-naive patients. METHODS: Between September 2009 and October 2012, a total of 2,023 STEMI patients were enrolled in the COMFORTABLE (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI]) and the SPUM-ACS (Inflammation and Acute Coronary Syndromes) studies. Patients receiving a prasugrel loading dose were divided into 2 groups: 1) clopidogrel and a subsequent prasugrel loading dose; and 2) a prasugrel loading dose. The primary safety endpoint was Bleeding Academic Research Consortium types 3 to 5 bleeding in hospital at 30 days. RESULTS: Of 2,023 patients undergoing primary percutaneous coronary intervention, 427 (21.1%) received clopidogrel and a subsequent prasugrel loading dose, 447 (22.1%) received a prasugrel loading dose alone, and the remaining received clopidogrel only. At 30 days, the primary safety endpoint was observed in 1.9% of those receiving clopidogrel and a subsequent prasugrel loading dose and 3.4% of those receiving a prasugrel loading dose alone (adjusted hazard ratio [HR]: 0.57; 95% confidence interval [CI]: 0.25 to 1.30, p = 0.18). The HAS-BLED (hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, labile international normalized ratio, elderly, drugs/alcohol concomitantly) bleeding score tended to be higher in prasugrel-treated patients (p = 0.076). The primary safety endpoint results, however, remained unchanged after adjustment for these differences (clopidogrel and a subsequent prasugrel loading dose vs. prasugrel only; HR: 0.54 [95% CI: 0.23 to 1.27], p = 0.16). No differences in the composite of cardiac death, myocardial infarction, or stroke were observed at 30 days (adjusted HR: 0.66, 95% CI: 0.27 to 1.62, p = 0.36). CONCLUSIONS: This observational, nonrandomized study of ST-segment elevation myocardial infarction patients suggests that the administration of a loading dose of prasugrel in patients pre-treated with a loading dose of clopidogrel is not associated with an excess of major bleeding events. (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI] [COMFORTABLE]; NCT00962416; and Inflammation and Acute Coronary Syndromes [SPUM-ACS]; NCT01000701).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

LncRNAs are transcripts greater than 200 nucleotides in length with no apparent coding potential. They exert important regulatory functions in the genome. Their role in cardiac fibrosis is however unexplored. To identify IncRNAs that could modulate cardiac fibrosis, we profiled the long non-coding transcriptome in the infarcted mouse heart, and identified 1500 novel IncRNAs. These IncRNAs have unique characteristics such as high tissue and cell type specificity. Their expression is highly correlated with parameters of cardiac dimensions and function. The majority of these novel IncRNAs are conserved in human. Importantly, human IncRNAs appear to be differentially expressed in heart disease. Using a computational pipeline, we identified a super-enhancer-associated IncRNA, which is dynamically expressed after myocardial infarction. We named this particular transcript Wisper for «Wisp2 super-enhancer- derived IncRNA ». Interestingly, Wisper expression is overexpressed in cardiac fibroblasts as compared to cardiomyocytes or to fibroblasts isolated from other organs than the heart. The importance of Wisper in the biology of fibroblasts was demonstrated in knockdown experiments. Differentiation of cardiac fibroblast into myofibroblasts in vitro is significantly impaired upon Wisper knockdown. Wisper downregulation in cardiac fibroblasts results in a dramatic reduction of fibrotic gene expression, a diminished cell proliferation and an increase in apoptotic cell death. In vivo, depletion of Wisper during the acute phase of the response to infarction is detrimental via increasing the risk of cardiac rupture. On the other hand, Wisper knockdown following infarction in a prevention study reduces fibrosis and preserves cardiac function. Since WISPER is detectable in the human heart, where it is associated with severe cardiac fibrosis, these data suggest that Wisper could represent a novel therapeutic target for limiting the extent of the fibrotic response in the heart. -- Les long ARN non-codants (IncRNAs) sont des ARN de plus de 200 nucléotides qui ne codent pas pour des protéines. Ils exercent d'importantes fonctions dans le génome. Par contre, leur importance dans le développement de la fibrose cardiaque n'a pas été étudiée. Pour identifier des IncRNAs jouant un rôle dans ce processus, le transcriptome non-codant a été étudié dans le coeur de'souris après un infarctus du myocarde. Nous avons découverts 1500 nouveaux IncRNAs. Ces transcrits ont d'uniques caractéristiques. En particulier ils sont extrêmement spécifiques de sous-populations de cellules cardiaques. Par ailleurs, leur expression est remarquablement corrélée avec les paramètres définissant les dimensions du coeur et la fonction cardiaque. La majorité de ces IncRNAs sont conservés chez l'humain. Certains sont modulés dans des pathologies cardiaques. En utilisant une approche bioinformatique, nous avons identifié un IncRNA qui est associé à des séquences amplificatrices et qui est particulièrement enrichi dans les fibroblastes cardiaques. Ce transcrit a été nommé Wisper pour «Wisp2 super-enhancer-derived IncRNA ». L'importance de Wisper dans la biologie des fibroblastes cardiaques est démontrée dans des expériences de déplétion. En l'absence de Wisper, l'expression de protéines impliquées dans le développement de la fibrose est dramatiquement réduite dans les fibroblastes cardiaques. Ceux-ci montrent une prolifération réduite. Le niveau d'apoptose est largement augmenté. In vivo, la déplétion de Wisper pendant la phase aiguë de l'infarctus rehausse le risque de rupture cardiaque. Au contraire, la réduction de l'expression de Wisper pendant la phase chronique diminue la fibrose cardiaque et améliore la fonction du coeur. Puisque Wisper est exprimé dans le coeur humain, ce transcrit représente une nouvelle cible thérapeutique pour limiter la réponse fibrotique dans le coeur.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.