970 resultados para ARTERIAL-PRESSURE
Resumo:
Hypertension is usually defined as having values of systolic blood pressure ≥140 mmHg, diastolic blood pressure ≥90 mmHg. Hypertension is one of the main adverse effects of glucocorticoid on the cardiovascular system. Glucocorticoids are essential hormones, secreted from adrenal glands in circadian fashion. Glucocorticoid's effect on blood pressure is conveyed by the glucocorticoid receptor (NR3C1), an omnipresent nuclear transcription factor. Although polymorphisms in this gene have long been implicated to be a causal factor for cardiovascular diseases such as hypertension, no study has yet thoroughly interrogated the gene's polymorphisms for their effect on blood pressure levels. Therefore, I have first resequenced ∼30 kb of the gene, encompassing all exons, promoter regions, 5'/3' UTRs as well as at least 1.5 kb of the gene's flanking regions from 114 chromosome 5 monosomic cell lines, comprised of three major American ethnic groups—European American, African American and Mexican American. I observed 115 polymorphisms and 14 common molecularly phased haplotypes. A subset of markers was chosen for genotyping study populations of GENOA (Genetic Epidemiology Network of Atherosclerosis; 1022 non-Hispanic whites, 1228 African Americans and 954 Mexican Americans). Since these study populations include sibships, the family-based association test was performed on 4 blood pressure-related quantitative variables—pulse, systolic blood pressure, diastolic blood pressure and mean arterial pressure. Using these analyses, multiple correlated SNPs are significantly protective against high systolic blood pressure in non-Hispanic whites, which includes rsb198, a SNP formerly associated with beneficial body compositions. Haplotype association analysis also supports this finding and all p-values remained significant after permutation tests. I therefore conclude that multiple correlated SNPs on the gene may confer protection against high blood pressure in non-Hispanic whites. ^
Resumo:
Trauma is a leading cause of death worldwide, and is thus a major public health concern. Improving current resuscitation strategies may help to reduce morbidity and mortality from trauma, and clinical research plays an important role in addressing these issues. This thesis is a secondary analysis of data that was collected for a randomized clinical trial being conducted at Ben Taub General Hospital. The trial is designed to compare a hypotensive resuscitation strategy to standard fluid resuscitation for the early treatment of trauma patients in hemorrhagic shock. This thesis examines the clinical outcomes from the first 90 subjects enrolled in the study, with the primary aim of assessing the safety of hypotensive resuscitation within the trauma population. ^ Patients in hemorrhagic shock who required emergent surgery were randomized to one of two arms of the study. Those in the experimental (LMAP) arm were managed with a hypotensive resuscitation strategy in which the target mean arterial pressure was 50mmHg. Those in the control (HMAP) arm were managed with standard fluid resuscitation to a target mean arterial pressure of 65mmHg. Patients were followed for 30 days. Mortality, post-operative complications, and other clinical data were prospectively gathered by the Ben Taub surgical staff and then secondarily analyzed for the purpose of this thesis.^ Subjects in the LMAP group had significantly lower early post-operative mortality compared to those in the HMAP group. 30-day mortality was also lower in the LMAP group, although this did not reach statistical significance. There were no statistically significant differences between the two groups with regards to development of ischemic, hematologic or infectious complications, length of hospitalization, length of ICU stay or duration of mechanical ventilation. ^ Based upon the data presented in this thesis, it appears that hypotensive resuscitation is a safe strategy for use in the trauma population. Specifically, hypotensive resuscitation reduced the risk of early post-operative death from coagulopathic bleeding and did not result in an increased risk of ischemic or other post-operative complications. The preliminary results described in this thesis provide convincing evidence support the continued investigation and use of hypotensive resuscitation in a trauma setting.^
Resumo:
Objective: To investigate hemodynamic responses to lateral rotation. ^ Design: Time-series within a randomized controlled trial pilot study. ^ Setting: A medical intensive care unit (ICU) and a medical-surgical ICU in two tertiary care hospitals. ^ Patients: Adult patients receiving mechanical ventilation. ^ Interventions: Two-hourly manual or continuous automated lateral rotation. ^ Measurements and Main Results: Heart rate (HR) and arterial pressure were sampled every 6 seconds for > 24 hours, and pulse pressure (PP) was computed. Turn data were obtained from a turning flow sheet (manual turn) or with an angle sensor (automated turn). Within-subject ensemble averages were computed for HR, mean arterial pressure (MAP), and PP across turns. Sixteen patients were randomized to either the manual (n = 8) or automated (n = 8) turn. Three patients did not complete the study due to hemodynamic instability, bed malfunction or extubation, leaving 13 patients (n = 6 manual turn and n = 7 automated turn) for analysis. Seven patients (54%) had an arterial line. Changes in hemodynamic variables were statistically significant increases ( p < .05), but few changes were clinically important, defined as ≥ 10 bpm (HR) or ≥ 10 mmHg (MAP and PP), and were observed only in the manual-turn group. All manual-turn patients had prolonged recovery to baseline in HR, MAP and PP of up to 45 minutes (p ≤ .05). No significant turning-related periodicities were found for HR, MAP, or PP. Cross-correlations between variables showed variable lead-lag relations in both groups. A statistically, but not clinically, significant increase in HR of 3 bpm was found for the manual-turn group in the back compared with the right lateral position ( F = 14.37, df = 1, 11, p = .003). ^ Conclusions: Mechanically ventilated critically ill patients experience modest hemodynamic changes with manual lateral rotation. A clinically inconsequential increase in HR, MAP, and PP may persist for up to 45 minutes. Automated lateral rotation has negligible hemodynamic effects. ^
Resumo:
Septic shock is a cytokine-mediated process typically caused by a severe underlying infection. Toxins generated by the infecting organism trigger a cascade of events leading to hypotension, to multiple organ system failure, and frequently to death. Beyond supportive care, no effective therapy is available for the treatment of septic shock. Nitric oxide (NO) is a potent vasodilator generated late in the sepsis pathway leading to hypotension; therefore, NO represents a potential target for therapy. We have previously demonstrated that transforming growth factor (TGF) beta1 inhibits inducible NO synthase (iNOS) mRNA and NO production in vascular smooth muscle cells after its induction by cytokines critical in the sepsis cascade. Thus, we hypothesized that TGF-beta1 may inhibit iNOS gene expression in vivo and be beneficial in the treatment of septic shock. In a conscious rat model of septic shock produced by Salmonella typhosa lipopolysaccharide (LPS), TGF-beta1 markedly reduced iNOS mRNA and protein levels in several organs. In contrast, TGF-beta1 did not decrease endothelium-derived constitutive NOS mRNA in organs of rats receiving LPS. We also performed studies in anesthetized rats to evaluate the effect of TGF-beta1 on the hemodynamic compromise of septic shock; after an initial 25% decrease in mean arterial pressure, TGF-beta1 arrested LPS-induced hypotension and decreased mortality. A decrease in iNOS mRNA and protein levels in vascular smooth muscle cells was demonstrated by in situ hybridization and NADPH diaphorase staining in rats treated with TGF-beta1. Thus these studies suggest that TGF-beta1 inhibits iNOS in vivo and that TGF-beta1 may be of future benefit in the therapy of septic shock.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Foods rich in adenine and hypoxanthine may contribute to the increase of uricemia. Hyperuricemia is associated with other pathological conditions pertaining to metabolic syndrome. Objective: the assessement of the impact of fiber rich diet on uricemia in patients with metabolic syndrome. Methods: the study involved 46 male patients with metabolic syndrome who claimed to have reduced mobility in fingers, hypertension, obesity, hyperglycemia and hyperuricemia. A validated questionnaire about dietary habits was applied at the beginning of the study and after 6 weeks of fiber-rich diet by eliminating from patients diet preparations of animal food and increased intake of vegetable foods. Blood presure, body mass index, blood glucose and uric acids were measured at the beginning of the study and after 6 weeks of fiber rich diet by daily consumption of 2 servings of added grains - 60g totally and vegetables 200g, fruits 300g respectively. Results: The study shows that at baseline all patients had an inadequate dietary intake of dietary fiber, 28.5 ± 2.2 g/day instead of 38 g per day.The increase in fiber intake of 10 ± 5 g/day was associated with a decrease of serum uric acid by 69.87% from 8.3 0.6 mg/dL to 5.8 0.5 mg/dL, p = 0.008, non-significant decrease of BMI (from 26.8 4.5 to 26.4 4.6 kg/m2, p<0.01), significant decrease of glycemia (from 130 0.8 to 105 4.2mg/dL, p <0.001) and significant decrease in blood pressure (from 150 10.6 to 130 8.4 mmHg, p <0.001). Conclusion: The fiber rich diet decreased blood uric acid, blood glucose levels an arterial pressure in patients with metabolic syndrome.
Resumo:
Objective: The calcineurin pathway has been involved in the development of cardiac hypertrophy, yet it remains unknown whether calcineurin activity can be regulated in myocardium independently from hypertrophy and cardiac load. Methods: To test that hypothesis, we measured calcineurin activity in a rat model of infrarenal aortic constriction (IR), which affects neurohormonal pathways without increasing cardiac afterload. Results: In this model, there was no change in arterial pressure over the 4-week experimental period, and the left ventricle/body weight ratio did not increase. At 2 weeks after IR, calcineurin activity was increased 1.8-fold (P
Resumo:
Characteristics obtained from peripheral pulses can be used to assess the status of cardiovascular system of subjects. However, nonintrusive techniques are preferred when prolonged monitoring is required for their comfort. Pulse transit time ( PTT) measurement has showed its potentials to monitor timing changes in peripheral pulse in cardiovascular and respiratory studies. In children, the common peripheries used for these studies are fingers or toes. Presently, there is no known study conducted on children to investigate the possible physiologic parameters that can confound PTT measure at these sites. In this study, PTT values from both peripheral sites were recorded from 55 healthy Caucasian children ( 39 male) with mean age of 8.4 +/- 2.3 years ( range 5 - 12 years). Peripheries' path length, heart rate, systolic blood pressure, diastolic blood pressure ( DBP) and mean arterial pressure ( MAP) were measured to investigate their contributions to PTT measurement. The results reveal that PTT is significantly related to all parameters ( P< 0.05), except for DBP and MAP. Age is observed to be the dominant factor that affects PTT at both peripheries in a child. Regression equations for PTT were derived for measuring from a finger and toe, ( 6.09 age + 189.2) ms and ( 6.70 age + 243.0) ms, respectively.
Resumo:
Background Brachial blood pressure predicts cardiovascular outcome at rest and during exercise. However, because of pulse pressure amplification, there is a marked difference between brachial pressure and central (aortic) pressure. Although central pressure is likely to have greater clinical importance, very little data exist regarding the central haemodynamic response to exercise. The aim of the present study was to determine the central and peripheral haemodynamic response to incremental aerobic exercise. Materials and methods Twelve healthy men aged 31 +/- 1 years (mean +/- SEM) exercised at 50%, 60%, 70% and 80% of their maximal heart rate (HRmax) on a bicycle ergometer. Central blood pressure and estimated aortic pulse wave velocity, assessed by timing of the reflected wave (T-R), were obtained noninvasively using pulse wave analysis. Pulse pressure amplification was defined as the ratio of peripheral to central pulse pressure and, to assess the influence of wave reflection on amplification, the ratio of peripheral pulse pressure to nonaugmented central pulse pressure (PPP : CDBP-P-1) was also calculated. Results During exercise, there was a significant, intensity-related, increase in mean arterial pressure and heart rate (P < 0.001). There was also a significant increase in pulse pressure amplification and in PPP : CDBP-P-1 (P < 0.001), but both were independent of exercise intensity. Estimated aortic pulse wave velocity increased during exercise (P < 0.001), indicating increased aortic stiffness. There was also a positive association between aortic pulse wave velocity and mean arterial pressure (r = 0.54; P < 0.001). Conclusions Exercise significantly increases pulse pressure amplification and estimated aortic stiffness.
Resumo:
Pulse transit time (PTT) is a non-invasive measure of arterial compliance. It can be used to assess instantaneous blood pressure (BP) changes in continual cardiovascular measurement such as during overnight respiratory sleep studies. In these studies, periodic changes in limb position can occur randomly. However, little is known about their possible effects on PTT monitored on the various limbs. The objective of this study was to evaluate PTT differences on all four limbs during two positional changes (lowering and raising of a limb). Ten healthy adults (seven male) with a mean age of 27.0 years were recruited in this study. The results showed that the limb that underwent a positional change had significant (p < 0.05) local PTT differences when compared to its nominal baseline value, whereas PTT changes in the other remaining limbs were insignificant (p > 0.05). The mean PTT value measured from a vertically-raised limb increased by 42.7 ms, while it decreased by 28.1 ms with a half-lowered limb. The PTT differences observed during positional change can be contributed to by the complex interactions between hydrostatic pressure changes, autonomic and local autoregulation experienced in these limbs. Hence the findings herein suggest that PTT is able to reflect local circulatory responses despite changes in the position of other limbs. This can be useful in prolonged clinical observations where limb movements are expected.
Resumo:
There were three principle aims to this thesis. Firstly, the acquisition protocols of clinical blood flow apparatus were investigated in order to optimise them for both cross-sectional and longitudinal application. Secondly, the effects of physiological factors including age and systematic circulation on ocular blood flow were investigated. Finally, the ocular perfusion characteristics of patients diagnosed with ocular diseases considered to be of a vascular origin were investigated. The principle findings of this work are:- 1) Optimisation of clinical investigationsPhotodiode sensitivity of the scanning laser Doppler flowmeter should be kept within a range of 70-150 DC when acquiring images of the retina and optic nerve head in order to optimise the reproducibility of capillary blood flow measures. Account of the physiological spatial variation in retinal blood flow measures can be made using standard analysis protocols of the scanning laser Doppler flowmeter combined with a local search strategy. Measurements of pulsatile ocular blood flow using the ocular blood flow analyser are reproducible, however this reproducibility can be improved when consecutive intraocular pressure pulses are used to calculate pulsatile ocular blood flow. Spectral analysis of the intraocular pressure pulse-wave is viable and identifies the first four harmonic components of the waveform. 2) Physiological variation in ocular perfusionAge results in a significant reduction in perfusion of the retinal microcirculation, which is not evident in larger vessel beds such as the choroid. Despite known asymmetry in the systemic vasculature, no evidence of interocular asymmetry in ocular perfusion is apparent. 3) Pathological variation in ocular perfusionIn primary open angle glaucoma, perfusion is reduced in the retinal microcirculation of patients classified as having early to moderate visual field defects. However, ocular pulsatility defects are masked when patients and subjects are matched for systemic variables (pulse rate and mean arterial pressure); differentiation is facilitated by the application of waveform analysis to the continuos intraocular pressure curve even in the early stages of disease. Diabetic patients with adequate glycaemic control, exhibit maintenance of macular blood flow, macular topography and visual function following phacoemulsification.
Resumo:
Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.
Resumo:
Background - Delivery of high-quality, evidence-based health care to deprived sectors of the community is a major goal for society. We investigated the effectiveness of a culturally sensitive, enhanced care package in UK general practices for improvement of cardiovascular risk factors in patients of south Asian origin with type 2 diabetes. Methods - In this cluster randomised controlled trial, 21 inner-city practices in the UK were assigned by simple randomisation to intervention (enhanced care including additional time with practice nurse and support from a link worker and diabetes-specialist nurse [nine practices; n=868]) or control (standard care [12 practices; n=618]) groups. All adult patients of south Asian origin with type 2 diabetes were eligible. Prescribing algorithms with clearly defined targets were provided for all practices. Primary outcomes were changes in blood pressure, total cholesterol, and glycaemic control (haemoglobin A1c) after 2 years. Analysis was by intention to treat. This trial is registered, number ISRCTN 38297969. Findings - We recorded significant differences between treatment groups in diastolic blood pressure (1·91 [95% CI -2·88 to -0·94] mm?Hg, p=0·0001) and mean arterial pressure (1·36 [-2·49 to -0·23] mm?Hg, p=0·0180), after adjustment for confounders and clustering. We noted no significant differences between groups for total cholesterol (0·03 [-0·04 to 0·11] mmol/L), systolic blood pressure (-0·33 [-2·41 to 1·75] mm?Hg), or HbA1c (-0·15% [-0·33 to 0·03]). Economic analysis suggests that the nurse-led intervention was not cost effective (incremental cost-effectiveness ratio £28?933 per QALY gained). Across the whole study population over the 2 years of the trial, systolic blood pressure, diastolic blood pressure, and cholesterol decreased significantly by 4·9 (95% CI 4·0–5·9) mm?Hg, 3·8 (3·2–4·4) mm?Hg, and 0·45 (0·40–0·51) mmol/L, respectively, and we recorded a small and non-significant increase for haemoglobin A1c (0·04% [-0·04 to 0·13]), p=0·290). Interpretation - We recorded additional, although small, benefits from our culturally tailored care package that were greater than the secular changes achieved in the UK in recent years. Stricter targets in general practice and further measures to motivate patients are needed to achieve best possible health-care outcomes in south Asian patients with diabetes. Funding - Pfizer, Sanofi-Aventis, Servier Laboratories UK, Merck Sharp & Dohme/Schering-Plough, Takeda UK, Roche, Merck Pharma, Daiichi-Sankyo UK, Boehringer Ingelheim, Eli Lilly, Novo Nordisk, Bristol-Myers Squibb, Solvay Health Care, and Assurance Medical Society UK.
Resumo:
AMP-activated protein kinase (AMPK) is present in the arterial wall and is activated in response to cellular stressors that raise AMP relative to ADP/ATP. Activation of AMPK in vivo lowers blood pressure but the influence of hyperlipidemia on this response has not been studied. ApoE-/- mice on high fat diet for 6 weeks and age-matched controls were treated with the AMPK activator, AICAR daily for two weeks. Under anesthesia, the carotid artery was cannulated for blood pressure measurements. Aortic tissue was removed for in vitro functional experiments and AMPK activity was measured in artery homogenates by Western blotting. ApoE-/- mice had significantly raised mean arterial pressure; chronic AICAR treatment normalized this but had no effect in normolipidemic mice, whereas acute administration of AICAR lowered mean arterial pressure in both groups. Chronic AICAR treatment increased phosphorylation of AMPK and its downstream target acetyl-CoA carboxylase in normolipidemic but not ApoE-/- mice. In aortic rings, AMPK activation induced vasodilation and an anticontractile effect, which was attenuated in ApoE-/- mice. This study demonstrates that hyperlipidemia dysregulates the AMPK pathway in the arterial wall but this effect can be reversed by AMPK activation, possibly through improving vessel compliance.
Resumo:
Introduction: Gait after stroke is characterized by a significant asymmetry between the lower limbs, with predominant use of the non-paretic lower limb (NPLL) over using the paretic lower limb. Accordingly, it has been suggested that adding load/weight to the NPLL as a form of restricting the movement of this limb may favor the use of the paretic limb, reducing interlimb asymmetry. However, few studies have been conducted up to this moment, which only investigated the immediate effects of this practice. Objectives: 1) Investigating whether there is an influence of adding load to the NPLL during treadmill training on cardiovascular parameters and on gait performance of individuals with stroke, compared to treadmill training without load addition; 2) Analyzing the effects of treadmill training with and without load added to the NPLL on kinematic parameters of each lower limb during gait; 3) Analyzing the effects of treadmill training with and without load added to the NPLL on measurements of functional mobility and postural balance of these patients. Materials and Methods: This is a randomized single blinded clinical trial involving 38 subjects, with a mean age of 56.5 years, at the subacute post-stroke phase (with mean time since stroke of 4.5 months). Participants were randomly assigned into an experimental group (EG) or control group (CG). EG (n= 19) was submitted to gait training on a treadmill with the addition of load to the NPLL by ankle weights equivalent to 5% of body weight. CG (n= 19) was only submitted to gait training on a treadmill. Behavioral strategies which included home exercises were also applied to both groups. The interventions occurred daily for two consecutive weeks (Day 1 to Day 9), being of 30 minutes duration each. Outcome measures: postural balance (Berg Functional Balance Scale – BBS), functional mobility (Timed Up and Go – TUG; kinematic variables of 180° turning) and kinematic gait variables were assessed at baseline (Day 0), after four training sessions (Day 4), after nine training sessions (Day 9), and 40 days after completion of training (Follow-up). Cardiovascular parameters (mean arterial pressure and heart rate) were evaluated at four moments within each training session. Analysis of variance (ANOVA) was used to compare outcomes between EG and CG in the course of the study (Day 0, Day 4, Day 9 and Follow-up). Unpaired t-tests allowed for intergroup comparison at each training session. 5% significance was used for all tests. Results: 1) Cardiovascular parameters (systemic arterial pressure, heart rate and derivated variables) did not change after the interventions and there were no differences between groups within each training session. There was an improvement in gait performance, with increased speed and distance covered, with no statistically significant difference between groups. 2) After the interventions, patients had increased paretic and non-paretic step lengths, in addition to exhibiting greater hip and knee joint excursion on both lower limbs. The gains were observed in the EG and CG, with no statistical difference between the groups and (mostly) maintained at follow-up. 3) After the interventions, patients showed better postural balance (higher scores on BBS) and functional mobility (reduced time spent on the TUG test and better performance on the 180° turning). All gains were observed in the EG and CG, with no statistically significant difference between groups and were maintained at follow-up. Conclusions: The addition of load to the NPLL did not affect cardiovascular parameters in patients with subacute stroke, similar to treadmill training without load, thus seemingly a safe training to be applied to these patients. However, the use of the load did not bring any additional benefits to gait training. The gait training program (nine training sessions on a treadmill + strategies and exercises for paretic limb stimulation) was useful for improving gait performance and kinematics, functional mobility and postural balance, and its use is suggested to promote the optimization of these outcomes in the subacute phase after stroke.