990 resultados para AMPLIFIED SAMPLE INJECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nature of this research is to investigate paleoseismic deformation of glacial soft sediments from three sampling sites throughout the Scottish Highlands; Arrat's Mills, Meikleour and Glen Roy. The paleoseismic evidence investigated in this research will provide a basis for applying criteria to soft sediment deformation structures, and the trigger mechanisms that create these structures. Micromorphology is the tool used in this to investigate paleoseismic deformation structures in thin section. Thin section analysis, (micromorphology) of glacial sediments from the three sampling sites is used to determine microscale evidence of past earthquakes that can be correlated to modem-day events and possibly lead to a better understanding of the impact of earthquakes throughout a range of sediment types. The significance of the three sampling locations is their proximity to two major active fault zones that cross Scotland. The fault zones are the Highland Boundary Fault and the Great Glen Fault, these two major faults that parallel each other and divide the country in half Sims (1975) used a set of seven criteria that identified soft sediment deformation structures created by a magnitude six earthquake in Cahfomia. Using criteria set forth by Sims (1975), the paleoseismic evidence can be correlated to the magnitude of the deformation structures found in the glacial sediments. This research determined that the microstructures at Arrat's Mill, Meikleour and Glen Roy are consistent with a seismically induced origin. It has also been demonstrated that, even without the presence of macrostructures, the use of micromorphology techniques in detecting such activity within sediments is of immense value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated, retrospectively, whether recidivism in a sample of court-ordered'graduates of an alcohol education and awareness program could be predicted. This alcohol education program was based on adult education principles and was philosophically akin to the thoughts of Drs. Jack Mezirow, Stephen Brookfield, and Patricia Cranton. Data on the sample of 214 Halton IDEA (Impaired Driver Education and Awareness) graduates were entered into a spread sheet. Descriptive statistics were generated. Each of the 214 program graduates had taken several tests during the course of the IDEA program. These tests measured knowledge, attitude about impaired driving, and degree of alcohol involvement. Test scores were analyzed to determine whether those IDEA graduates who recidivated differed in any measurable way from those who had no further criminal convictions after a period of at least three years. Their criminal records were obtained from the Canadian Police Information Centre (CPIC). Those program graduates who reoffended were compared to the vast majority who did not reoffend. Results of the study indicated that there was no way to determine who would recidivate from the data that were collected. Further studies could use a qualitative model. Follow-up interviews could be used to determine what impact, if any, attendance at the IDEA program had on the life of the graduates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to compare the results of the Motivation Assessment Scale (MAS; Durand & Crimmins, 1988), Questions About Behavior Function Scale (QABF; Matson & Vollmer, 1996) and Functional Analysis Screening Tool (FAST; Iwata & Deleon, 1996), when completed by parent informants in a sample of children and youth with autism spectrum disorders (ASD) who display challenging behaviour. Results indicated that there was low agreement between the functional hypotheses derived from each of three measures. In addition, correlations between functionally analogous scales were substantially lower than expected, while correlations between non-analogous subscales were stronger than anticipated. As indicated by this study, clinicians choosing to use FBA questionnaires to assess behavioural function, may not obtain accurate functional hypotheses, potentially resulting in ineffective intervention plans. The current study underscores the caution that must be taken when asking parents to complete these questionnaires to determine the function(s) of challenging behaviour for children/youth with ASD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present research focused on the pathways through which the symptoms of posttraumatic stress disorder (PTSD) may negatively impact intimacy. Previous research has confirmed a link between self-reported PTSD symptoms and intimacy; however, a thorough examination of mediating paths, partner effects, and secondary traumatization has not yet been realized. With a sample of 297 heterosexual couples, intraindividual and dyadic models were developed to explain the relationships between PTSD symptoms and intimacy in the context of interdependence theory, attachment theory, and models of selfpreservation (e.g., fight-or-flight). The current study replicated the findings of others and has supported a process in which affective (alexithymia, negative affect, positive affect) and communication (demand-withdraw behaviour, self-concealment, and constructive communication) pathways mediate the intraindividual and dyadic relationships between PTSD symptoms and intimacy. Moreover, it also found that the PTSD symptoms of each partner were significantly related; however, this was only the case for those dyads in which the partners had disclosed most everything about their traumatic experiences. As such, secondary traumatization was supported. Finally, although the overall pattern of results suggest a total negative effect of PTSD symptoms on intimacy, a sex difference was evident such that the direct effect of the woman's PTSD symptoms were positively associated with both her and her partner's intimacy. I t is possible that the Tend-andBefriend model of threat response, wherein women are said to foster social bonds in the face of distress, may account for this sex difference. Overall, however, it is clear that PTSD symptoms were negatively associated with relationship quality and attention to this impact in the development of diagnostic criteria and treatment protocols is necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary objective of this research project was to identify prostate cancer (PCa) -specific biomarkers from urine. This was done using a multi-faceted approach that targeted (1) the genome (DNA); (2) the transcriptome (mRNA and miRNA); and (3) the proteome. Toward this end, urine samples were collected from ten healthy individuals, eight men with PCa and twelve men with enlarged, non-cancerous prostates or with Benign Prostatic Hyperplasia (BPH). Urine samples were also collected from the same patients (PCa and BPH) as part of a two-year follow-up. Initially urinary nucleic acids and proteins were assessed both qualitatively and quantitatively for characteristics either unique or common among the groups. Subsequently macromolecules were pooled within each group and assessed for either protein composition via LC-MS/MS or microRNA (miRNA) expression by microarray. A number of potential candidates including miRNAs were identified as being deregulated in either pooled PCa or BPH with respect to the healthy control group. Candidate biomarkers were then assessed among individual samples to validate their utility in diagnosing PCa and/or differentiating PCa from BPH. A number of potential targets including deregulation of miRNAs 1825 and 484, and mRNAs for Fibronectin and Tumor Protein 53 Inducible Nuclear Protein 2 (TP53INP2) appeared to be indicative of PCa. Furthermore, deregulation of miR-498 appeared to be indicative of BPH. The sensitivities and specificities associated with using deregulation in many of these targets to subsequently predict PCa or BPH were also determined. This research project has identified a number of potential targets, detectable in urine, which merit further investigation towards the accurate identification of PCa and its discrimination from BPH. The significance of this work is amplified by the non-invasive nature of the sample source from which these candidates were derived, urine. Many cancer biomarker discovery studies have tended to focus primarily on blood (plasma or serum) and/or tissue samples. This is one of the first PCa biomarker studies to focus exclusively on urine as a sample source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Payment for the Cogswell, Sample and Howard accounts, Feb. 29, 1884.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Payment for the Cogswell, Howard and Sample accounts, Aug. 29, 1884.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Payment for the Cogswell, Howard and Sample accounts, Feb. 27, 1885.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de la Ingeniería Eléctrica con Especialidad en Control Automático) UANL, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of multivariate linear regression (MLR) models, it is well known that commonly employed asymptotic test criteria are seriously biased towards overrejection. In this paper, we propose a general method for constructing exact tests of possibly nonlinear hypotheses on the coefficients of MLR systems. For the case of uniform linear hypotheses, we present exact distributional invariance results concerning several standard test criteria. These include Wilks' likelihood ratio (LR) criterion as well as trace and maximum root criteria. The normality assumption is not necessary for most of the results to hold. Implications for inference are two-fold. First, invariance to nuisance parameters entails that the technique of Monte Carlo tests can be applied on all these statistics to obtain exact tests of uniform linear hypotheses. Second, the invariance property of the latter statistic is exploited to derive general nuisance-parameter-free bounds on the distribution of the LR statistic for arbitrary hypotheses. Even though it may be difficult to compute these bounds analytically, they can easily be simulated, hence yielding exact bounds Monte Carlo tests. Illustrative simulation experiments show that the bounds are sufficiently tight to provide conclusive results with a high probability. Our findings illustrate the value of the bounds as a tool to be used in conjunction with more traditional simulation-based test methods (e.g., the parametric bootstrap) which may be applied when the bounds are not conclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we develop finite-sample inference procedures for stationary and nonstationary autoregressive (AR) models. The method is based on special properties of Markov processes and a split-sample technique. The results on Markovian processes (intercalary independence and truncation) only require the existence of conditional densities. They are proved for possibly nonstationary and/or non-Gaussian multivariate Markov processes. In the context of a linear regression model with AR(1) errors, we show how these results can be used to simplify the distributional properties of the model by conditioning a subset of the data on the remaining observations. This transformation leads to a new model which has the form of a two-sided autoregression to which standard classical linear regression inference techniques can be applied. We show how to derive tests and confidence sets for the mean and/or autoregressive parameters of the model. We also develop a test on the order of an autoregression. We show that a combination of subsample-based inferences can improve the performance of the procedure. An application to U.S. domestic investment data illustrates the method.