968 resultados para wrist monitor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective.- The Patient-Rated Wrist Evaluation is a specific questionnaire for the wrist [1]. It consists of 15 questions with a total score of 100. It was recently translated into French [2]. However, its validity has not been tested in this language. The Disabilities Arm Shoulder and Hand (DASH), with well-established psychometric properties, is considered as the reference questionnaire for the evaluation of upper extremities. The objective of this study is to measure the construct validity of the PRWE-F with the DASH-F in patients with wrist pathology.Patients and methods.- Fifty-one patients (40 m, 11 w, mean age 42 years), 25 fractures of the radius and 26 lesions of the carpus.Questionnaires PRWE-F and DASH-F at entry and at discharge (0 to 100). Calculation of the construct validity of the PRWE-F comparing with the DASH-F with Pearson correlation coefficients (r) at entry and at discharge. Level of significance (alpha) was set at 5%.Results.- Correlation DASH/PRWE at entry: r = 0.799 (95% CI 0.671 to 0.881), P < 0.0001. Correlation DASH/PRWE at discharge: r = 0.847 (95% CI: 0.745 to 0.910), P < 0.0001.Discussion.- The construct validity of the two instruments indicates that they measure the same concept. Our correlation between DASH-F and PRWE-F, going from 0.799 to 0.847, are comparable to those published in different languages (0.71 to 0.84) [3,4]. The questionnaires PRWE-F can thus be used in rehabilitation patients presenting with wrist pathologies; it is comparable to the DASH but described by MacDermid [1] to be more specific. Compared to the DASH it has the advantage of consisting of two dimensions. Its construct validity is excellent. This questionnaire should be evaluated in other populations, and it should be compared with hand questionnaires more specific than the DASH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensity-modulated radiotherapy (IMRT) treatment plan verification by comparison with measured data requires having access to the linear accelerator and is time consuming. In this paper, we propose a method for monitor unit (MU) calculation and plan comparison for step and shoot IMRT based on the Monte Carlo code EGSnrc/BEAMnrc. The beamlets of an IMRT treatment plan are individually simulated using Monte Carlo and converted into absorbed dose to water per MU. The dose of the whole treatment can be expressed through a linear matrix equation of the MU and dose per MU of every beamlet. Due to the positivity of the absorbed dose and MU values, this equation is solved for the MU values using a non-negative least-squares fit optimization algorithm (NNLS). The Monte Carlo plan is formed by multiplying the Monte Carlo absorbed dose to water per MU with the Monte Carlo/NNLS MU. Several treatment plan localizations calculated with a commercial treatment planning system (TPS) are compared with the proposed method for validation. The Monte Carlo/NNLS MUs are close to the ones calculated by the TPS and lead to a treatment dose distribution which is clinically equivalent to the one calculated by the TPS. This procedure can be used as an IMRT QA and further development could allow this technique to be used for other radiotherapy techniques like tomotherapy or volumetric modulated arc therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the magnetic resonance imaging (MRI) findings in athletic injuries of the extensor carpi ulnaris (ECU) subsheath, assessing the utility of gadolinium-enhanced (Gd) fat-saturated (FS) T1-weighted sequences with wrist pronation and supination. METHODS: Sixteen patients (13 male, three female; mean age 30.3 years) with athletic injuries of the ECU subsheath sustained between January 2003 and June 2009 were included in this retrospective study. Initial and follow-up 1.5-T wrist MRIs were performed with transverse T1-weighted and STIR sequences in pronation, and Gd FS T1-weighted sequences with wrist pronation and supination. Two radiologists assessed the type of injury (A to C), ECU tendon stability, associated lesions and rated pulse sequences using a three-point scale: 1=poor, 2=good and 3=excellent. RESULTS: Gd-enhanced FS T1-weighted transverse sequences in supination (2.63) and pronation (2.56) were most valuable, compared with STIR (2.19) and T1-weighted (1.94). Nine type A, one type B and six type C injuries were found. There were trends towards diminution in size, signal intensity and enhancement of associated pouches on follow-up MRI and tendon stabilisation within the ulnar groove. CONCLUSION: Gd-enhanced FS T1-weighted sequences with wrist pronation and supination are most valuable in assessing and follow-up athletic injuries of the ECU subsheath on 1.5-T MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to introduce and describe a newly developed index using foot pressure analysis to quantify the degree of equinus gait in children with cerebral palsy before and after injection with botulinum toxin. Data were captured preinjection and 12 weeks postinjection. Ten children aged 2(1/2) to 6(1/2) years took part (5 boys and 5 girls). Three of them had a diagnosis of spastic diplegia and 7 of congenital hemiplegia. In total, 13 limbs were analyzed. After orientation and segmentation of raw pedobarographic data, we determined a dynamic foot pressure index graded 0 to 100 that quantified the relative degree of heel and forefoot contact during stance. These data were correlated (Pearson correlation) with clinical measurements of dorsiflexion at the ankle (on a slow and fast stretch) and video observation (using the Observational Gait Scale). Pedobarograph data were strongly correlated with both the Observational Gait Scale scores (R = 0.79, P < 0.005) and clinical measurements of dorsiflexion on a fast stretch, which is reflective of spasticity (R = 0.70, P < 0.005). We demonstrated the index's sensitivity in detecting changes in spasticity and good correlation with video observations seems to indicate this technique's potential validity. When manipulated and segmented appropriately, and with the development of a simple ordinal index, we found that foot pressure data provided a useful tool in tracking changes in patients with spastic equinus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Learning Affect Monitor (LAM) is a new computer-based assessment system integrating basic dimensional evaluation and discrete description of affective states in daily life, based on an autonomous adapting system. Subjects evaluate their affective states according to a tridimensional space (valence and activation circumplex as well as global intensity) and then qualify it using up to 30 adjective descriptors chosen from a list. The system gradually adapts to the user, enabling the affect descriptors it presents to be increasingly relevant. An initial study with 51 subjects, using a 1 week time-sampling with 8 to 10 randomized signals per day, produced n = 2,813 records with good reliability measures (e.g., response rate of 88.8%, mean split-half reliability of .86), user acceptance, and usability. Multilevel analyses show circadian and hebdomadal patterns, and significant individual and situational variance components of the basic dimension evaluations. Validity analyses indicate sound assignment of qualitative affect descriptors in the bidimensional semantic space according to the circumplex model of basic affect dimensions. The LAM assessment module can be implemented on different platforms (palm, desk, mobile phone) and provides very rapid and meaningful data collection, preserving complex and interindividually comparable information in the domain of emotion and well-being.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Measurement of plasma renin activity (PRA) is the gold standard for monitoring mineralocorticoid treatment in humans with primary hypoadrenocorticism (PH). OBJECTIVES: To compare PRA in dogs with newly diagnosed PH, dogs with diseases mimicking PH, and healthy dogs, and evaluate measurement of PRA to monitor therapeutic effects in dogs with PH treated with different mineralocorticoids. ANIMALS: Eleven dogs with newly diagnosed PH (group 1), 10 dogs with diseases mimicking PH (group 2), 21 healthy dogs (group 3), 17 dogs with treated PH (group 4). METHODS: In group 1, PRA was measured before treatment and at different times after initiating treatment. In groups 2 and 3, PRA was measured at initial presentation only. In group 4, no baseline PRA was obtained but PRA was measured once or every 1-6 months during treatment. Mineralocorticoid treatment consisted of fludrocortisone acetate (FC) or desoxycorticosterone pivalate (DOCP). RESULTS: Plasma renin activity before treatment was increased in dogs with PH compared to normal dogs and dogs with diseases mimicking PH with median activity of 27, 0.8, and 1.0 ng/mL/h, respectively. In dogs with PH, PRA decreased and normalized with mineralocorticoid treatment using DOCP but not with FC. In dogs treated with DOCP, PRA was lower than in dogs treated with FC. Plasma sodium concentrations were higher and potassium concentrations were lower with DOCP treatment compared to FC treatment. CONCLUSION AND CLINICAL IMPORTANCE: Plasma renin activity is a reliable tool for monitoring mineralocorticoid treatment. DOCP treatment more effectively suppresses PRA compared to FC in dogs with PH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mechanical gauge was developed to monitor the movement of crack or joint openings in portland cement concrete structures, in general, and portland cement concrete pavements in particular. Designed to be inexpensive and simple to operate, this gauge is capable of recording maximum, minimum, and instantaneous crack or joint openings. Specific recommendations were made for recording minimum and maximum pavement temperature over the monitoring period. The report was written as a set of guidelines for design, fabrication, installation, and operation of the gauge as well as the temperature measuring device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall aim of the project has been to assess the extent to which data on the frequency of occurence of STDs [Sexually transmitted diseases] might be useful in the monitoring and evaluation of AIDS prevention programmes. The objectives have been to answer the following questions: (a) Can measures of STD occurence be used as an outcome measure of AIDS/HIV preventive efforts ? In particular: -> which diseases might be useful ? -> in what ways could they be used ? (b) If measures of STD occurence can be used in this way, is existing surveillance data in Western Europe adequate for the purpose ? If not why not ? (c) What do data from existing STD surveillance systems tell us about the success or failure of AIDS prevention to date ? (d) What needs to be done in order taht STD surveillance data in the countries of Western Europe could be used for this purpose ? [Authors, p. 4]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When decommissioning a nuclear facility it is important to be able to estimate activity levels of potentially radioactive samples and compare with clearance values defined by regulatory authorities. This paper presents a method of calibrating a clearance box monitor based on practical experimental measurements and Monte Carlo simulations. Adjusting the simulation for experimental data obtained using a simple point source permits the computation of absolute calibration factors for more complex geometries with an accuracy of a bit more than 20%. The uncertainty of the calibration factor can be improved to about 10% when the simulation is used relatively, in direct comparison with a measurement performed in the same geometry but with another nuclide. The simulation can also be used to validate the experimental calibration procedure when the sample is supposed to be homogeneous but the calibration factor is derived from a plate phantom. For more realistic geometries, like a small gravel dumpster, Monte Carlo simulation shows that the calibration factor obtained with a larger homogeneous phantom is correct within about 20%, if sample density is taken as the influencing parameter. Finally, simulation can be used to estimate the effect of a contamination hotspot. The research supporting this paper shows that activity could be largely underestimated in the event of a centrally-located hotspot and overestimated for a peripherally-located hotspot if the sample is assumed to be homogeneously contaminated. This demonstrates the usefulness of being able to complement experimental methods with Monte Carlo simulations in order to estimate calibration factors that cannot be directly measured because of a lack of available material or specific geometries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME L'obésité et l'hypertension atteignent des niveaux épidémiques aussi bien dans les pays industrialisés que dans ceux en voie de développement. La coexistence de ces deux pathologies est associée à un risque cardiovasculaire augmenté. Traditionnellement on mesure la pression artérielle (PA) au bras au moyen d'un brassard qui détermine la pression systolique et diastolique en utilisant soit la méthode auscultatoire ou oscillométrique. L'utilisation d'un brassard de taille standard chez le patient avec un tour de bras augmenté peut surestimer la pression artérielle. Il semble même qu'il existe un rapport idéal entre le tour de bras, et la taille du brassard La mesure à domicile de la pression artérielle avec des appareils validés donne des valeurs de la PA valables. Plusieurs appareils existent sur le marché et depuis quelques années les appareils de mesure de la PA au poignet font leur apparition sur le marché. Cette étude vise à comparer chez des sujets sains et obèses les valeurs de PA obtenues au poignet avec celles obtenues au bras en utilisant deux appareils validés l'OMRON HEM 705-CP et l'OMRON R6. L'OMRON HEM 705-CP permet l'utilisation soit d'un brassard standard (13x30 cm) ou d'un brassard large (16x38 cm), et l'OMRON R6 mesure la PA au poignet. Nous avons comparé un groupe de sujets obèses [Body Mass Index (BMI) >35kg/m2] avec un groupe de sujets sains (BMI <25kg/m2). Ont été exclues de l'étudé les personnes prenant un traitement antihypertenseur ainsi que celles souffrant d'arythmies. La PA a été mesurée en position assise avec le bras gauche sur une table à hauteur du coeur. Un brassard large a été employé pour les sujets obèses et un brassard standard pour les sujets sains. Trois mesures ont été effectuées, la première après une pause de 5 min et chacune des suivantes avec un intervalle de 2 min. La pression d'inflation maximale a été fixée à 170 mmHg. Nous avons utilisé la formule proposée par Marks LA et al pour déterminer si le rapport entre la taille des brassards fournis avec l'OMRON .HEM 705-CP et le tour de bras de nos sujets était optimal (taille du brassard = 9.34 x log10 taille du bras). Nos résultats ne montrent pas de différence statistiquement significative de la PA diastolique entre les deux groupes, qu'elle soit mesurée au bras ou au poignet. La PA systolique mesurée au bras s'est par contre avérée significativement plus basse chez les sujets obèses que chez les sujets sains. Aucune différence n'a été trouvée lorsque la mesure est effectuée au poignet. En utilisant la formule fournie par Marks le rapport entre taille du brassard (large chez les obèses) et tour de bras a été de 10.30±30 chez les sujets obèses et 9.630.45 chez les sujets sains (p<0.001). Le rapport entre tour de bras et brassard chez les sujets obèses est nettement au-dessus de la valeur optimale, ce qui suggère une possible sous-estimation de la PA systolique chez ces sujets. Ces résultats suggèrent qu'il existe un risque de sous-estimer la PA chez le patient obèse lors de l'utilisation d'un brassard large. Cette erreur pourrait être réduite par l'utilisation d'appareils de mesure au poignet. validés chez le sujet obèse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commercially available instruments for road-side data collection take highly limited measurements, require extensive manual input, or are too expensive for widespread use. However, inexpensive computer vision techniques for digital video analysis can be applied to automate the monitoring of driver, vehicle, and pedestrian behaviors. These techniques can measure safety-related variables that cannot be easily measured using existing sensors. The use of these techniques will lead to an improved understanding of the decisions made by drivers at intersections. These automated techniques allow the collection of large amounts of safety-related data in a relatively short amount of time. There is a need to develop an easily deployable system to utilize these new techniques. This project implemented and tested a digital video analysis system for use at intersections. A prototype video recording system was developed for field deployment. A computer interface was implemented and served to simplify and automate the data analysis and the data review process. Driver behavior was measured at urban and rural non-signalized intersections. Recorded digital video was analyzed and used to test the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’objectiu d’aquest projecte és desenvolupar una aplicació per a mòbils Android que permeti visualitzar missatges curts en un monitor d’ordinador o TV. Els missatges es gestionaran a partir d’una aplicació de mòbil que inclourà la generació, gestió i transmissió dels missatges al monitor