967 resultados para winter warming


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Global warming can have a significant impact on building energy performance and indoor thermal environment, as well as the health and productivity of people living and working inside them. Through the building simulation technique, this paper investigates the adaptation potential of different selections of building physical properties to increased outdoor temperature in Australia. It is found that overall, an office building with lower insulation level, smaller window to wall ratio and/or a glass type with lower shading coefficient, and lower internal load density will have the effect of lowering building cooling load and total energy use, and therefore have a better potential to adapt to the warming external climate. Compared with clear glass, it is shown that the use of reflective glass for the sample building with WWR being 0.5 reduces the building cooling load by more than 12%. A lower internal load can also have a significant impact on the reduction of building cooling load, as well as the building energy use. Through the comparison of results between current and future weather scenarios, it is found that the patterns found in the current weather scenario also exist in the future weather scenarios, but to a smaller extent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As global warming entails new conditions for the built environment, the thermal behavior of existing buildings, which were designed based on current weather data, may become unclear and remain a great concern. Through building computer simulation, this paper investigates the sensitivity of different office building zoning to the potential global warming. From the sample office building examined, it is found that compared with the middle and top floors, the ground floor for most cities appears to be most sensitive to the effect of global warming and has the highest tendency to having the overheating problem. From the analysis of the responses of different zone orientations to the outdoor air temperature increase, it is also found that there are widely different responses between different zone orientations, with South or Core zone being most sensitive. With an increased external air temperature, the difference between different floors or different zone orientations will become more significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following discussion is in response to a 2010 article published in the Journal of Safety Research by J.C.F. de Winter and D. Dodou entitled “The Driver Behaviour Questionnaire as a predictor of accidents: A meta-analysis” (Volume 41, Number 6, pp. 463-470, available on sciencedirect.com). The editors are pleased to provide a forum for this exchange and welcome further comments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Learning and then recognizing a route, whether travelled during the day or at night, in clear or inclement weather, and in summer or winter is a challenging task for state of the art algorithms in computer vision and robotics. In this paper, we present a new approach to visual navigation under changing conditions dubbed SeqSLAM. Instead of calculating the single location most likely given a current image, our approach calculates the best candidate matching location within every local navigation sequence. Localization is then achieved by recognizing coherent sequences of these “local best matches”. This approach removes the need for global matching performance by the vision front-end - instead it must only pick the best match within any short sequence of images. The approach is applicable over environment changes that render traditional feature-based techniques ineffective. Using two car-mounted camera datasets we demonstrate the effectiveness of the algorithm and compare it to one of the most successful feature-based SLAM algorithms, FAB-MAP. The perceptual change in the datasets is extreme; repeated traverses through environments during the day and then in the middle of the night, at times separated by months or years and in opposite seasons, and in clear weather and extremely heavy rain. While the feature-based method fails, the sequence-based algorithm is able to match trajectory segments at 100% precision with recall rates of up to 60%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poem

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Many Australian cities experience large winter increases in deaths and hospitalisations. Flu outbreaks are only part of the problem and inadequate protection from cold weather is a key independent risk factor. Better home insulation has been shown to improve health during winter, but no study has examined whether better personal insulation improves health. Data and Methods We ran a randomised controlled trial of thermal clothing versus usual care. Subjects with heart failure (a group vulnerable to cold) were recruited from a public hospital in Brisbane in winter and followed-up at the end of winter. Those randomised to the intervention received two thermal hats and tops and a digital thermometer. The primary outcome was the number of days in hospital, with secondary outcomes of General Practitioner (GP) visits and self-rated health. Results The mean number of days in hospital per 100 winter days was 2.5 in the intervention group and 1.8 in the usual care group, with a mean difference of 0.7 (95% CI: –1.5, 5.4). The intervention group had 0.2 fewer GP visits on average (95% CI: –0.8, 0.3), and a higher self-rated health, mean improvement –0.3 (95% CI: –0.9, 0.3). The thermal tops were generally well used, but even in cold temperatures the hats were only worn by 30% of subjects. Conclusions Thermal clothes are a cheap and simple intervention, but further work needs to be done on increasing compliance and confirming the health and economic benefits of providing thermals to at-risk groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To examine the epidemiology and burden of respiratory illness during winter in urban children from temperate Australia. Methods: We conducted a cohort study of healthy Melbourne children, aged from 12 to 71 months. Parents kept a daily respiratory symptom diary and recorded resource use when an influenza-like illness (ILI) occurred. Results: One-hundred and eighteen children had 137 ILI episodes over 12 weeks for a rate of 0.53 ILI episodes per child-month (95% CI 0.44-0.61). Risk factors for ILI included younger age, fewer people residing in the household, structured exposure to other children outside the home, and a higher household income. Episodes had a mean duration of 10.4 days with 64 visits to a general practitioner (46.7 GP visits per 100 episodes), 27 antibiotic courses prescribed (19.7 antibiotic courses per 100 episodes), and three overnight hospitalizations (2.2 admissions per 100 episodes). Parents reported an average of 11.7 h excess time spent caring for a child per episode. Conclusions: Respiratory illnesses are a common and largely neglected cause of illness in Australian children. Pathogen-specific data are required to better assess the likely impact of available and developing vaccines and other treatment options.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Working as a sport psychologist with Olympic athletes requires a clear understanding of a broad range of multifaceted individual, group, situational, and environmental issues, all of which have the ability to impact upon performance. This article provides an overview of some of the common yet vital issues that have been observed to arise when working with Olympic Winter Games athletes and teams; what to expect, how to recognise them when they occur, and why they are important to prepare for in the context of supporting athletes to achieve the best performance they can at an Olympic Games. Aimed at the emerging sport psychology practitioner, discussion of issues such as performing under pressure, dealing with distractions, adjusting to external factors, team culture, and servicing models creates an informal set of “practical guidelines” based upon real-world experiences that can also be applied to other major sporting competitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Land use and agricultural practices can result in important contributions to the global source strength of atmospheric nitrous oxide (N2O) and methane (CH4). However, knowledge of gas flux from irrigated agriculture is very limited. From April 2005 to October 2006, a study was conducted in the Aral Sea Basin, Uzbekistan, to quantify and compare emissions of N2O and CH4 in various annual and perennial land-use systems: irrigated cotton, winter wheat and rice crops, a poplar plantation and a natural Tugai (floodplain) forest. In the annual systems, average N2O emissions ranged from 10 to 150 μg N2O-N m−2 h−1 with highest N2O emissions in the cotton fields, covering a similar range of previous studies from irrigated cropping systems. Emission factors (uncorrected for background emission), used to determine the fertilizer-induced N2O emission as a percentage of N fertilizer applied, ranged from 0.2% to 2.6%. Seasonal variations in N2O emissions were principally controlled by fertilization and irrigation management. Pulses of N2O emissions occurred after concomitant N-fertilizer application and irrigation. The unfertilized poplar plantation showed high N2O emissions over the entire study period (30 μg N2O-N m−2 h−1), whereas only negligible fluxes of N2O (<2 μg N2O-N m−2 h−1) occurred in the Tugai. Significant CH4 fluxes only were determined from the flooded rice field: Fluxes were low with mean flux rates of 32 mg CH4 m−2 day−1 and a low seasonal total of 35.2 kg CH4 ha−1. The global warming potential (GWP) of the N2O and CH4 fluxes was highest under rice and cotton, with seasonal changes between 500 and 3000 kg CO2 eq. ha−1. The biennial cotton–wheat–rice crop rotation commonly practiced in the region would average a GWP of 2500 kg CO2 eq. ha−1 yr−1. The analyses point out opportunities for reducing the GWP of these irrigated agricultural systems by (i) optimization of fertilization and irrigation practices and (ii) conversion of annual cropping systems into perennial forest plantations, especially on less profitable, marginal lands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of the nitrogen (N) application rates 0, 120, 180 and 240 kg N ha−1 in combination with low or medium water levels in the cultivation of winter wheat (Triticum aestivum L.) cv. Kupava was studied for the 2005–2006 and 2006–2007 growing seasons in the Khorezm region of Uzbekistan. The results show an impact of the initial soil Nmin (NO3-N + NH4-N) levels measured at wheat seeding on the N fertilizer rates applied. When the Nmin content in the 0–50 cm soil layer was lower than 10 mg kg−1 during wheat seeding in 2005, the N rate of 180 kg ha−1 was found to be the most effective for achieving high grain yields of high quality. With a higher Nmin content of about 30 mg kg−1 as was the case in the 2006 season, 120 kg N ha−1 was determined as being the technical and economical optimum. The temporal course of N2O emissions of winter wheat cultivation for the two water-level studies shows that emissions were strongly influenced by irrigation and N-fertilization. Extremely high emissions were measured immediately after fertilizer application events that were combined with irrigation events. Given the high impact of N-fertilizer and irrigation-water management on N2O emissions, it can be concluded that present N-management practices should be modified to mitigate emissions of N2O and to achieve higher fertilizer use efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Women undergoing cesarean section are vulnerable to adverse effects associated with inadvertent perioperative hypothermia, but there has been a lack of synthesized evidence for temperature management in this population. This systematic review aimed to synthesize the best available evidence in relation to preventing hypothermia in mothers undergoing cesarean section surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internal heat sources may not only consume energy directly through their operation (e.g. lighting), but also contribute to building cooling or heating loads, which indirectly change building cooling and heating energy. Through the use of building simulation technique, this paper investigates the influence of building internal load densities on the energy and thermal performance of air conditioned office buildings in Australia. Case studies for air conditioned office buildings in major Australian capital cities are presented. It is found that with a decrease of internal load density in lighting and/or plug load, both the building cooling load and total energy use can be significantly reduced. Their effect on overheating hour reduction would be dependent on the local climate. In particular, it is found that if the building total internal load density is reduced from the base case of “medium” to “extra–low, the building total energy use under the future 2070 high scenario can be reduced by up to 89 to 120 kWh/m² per annum and the overheating problem could be completely avoided. It is suggested that the reduction in building internal load densities could be adopted as one of adaptation strategies for buildings in face of the future global warming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Engaging in a close analysis of legal and political discourse, this chapter considers conflicts over intellectual property and climate change in three key arenas: climate law; trade law; and intellectual property law. In this chapter, it is argued that there is a need to overcome the political stalemates and deadlocks over intellectual property and climate change. It is essential that intellectual property law engage in a substantive fashion with the matrix of issues surrounding fossil fuels, clean technologies, and climate change at an international level. First, this chapter examines the debate over intellectual property and climate change under the auspices of the United Nations Framework Convention on Climate Change 1992, and the establishment of the UNFCCC Climate Technology Centre and Network. It recommends that the technology mechanism should address and deal with matters of intellectual property management and policy. Second, the piece examines the discussion of global issues in the World Intellectual Property Organization, WIPO GREEN. It supports the proposal for a Global Green Patent Highway to allow for the fast-tracking of intellectual property applications in respect of green technologies. Third, the chapter investigates the dispute in the TRIPS Council at the World Trade Organization over intellectual property, climate change, and development. This section focuses upon the TRIPS Agreement 1994. This chapter calls for a Joint Declaration on Intellectual Property and Climate Change from the UNFCCC, WIPO, and the WTO. The paper concludes that intellectual property should be reformed as part of a larger effort to promote climate justice. Rather than adopt a fragmented, piecemeal approach in various international institutions, there is a need for a co-ordinated and cohesive response to intellectual property in an age of runaway, global climate change. Patent law should be fossil fuel free. Intellectual property should encourage research, development, and diffusion of renewable energy and clean technologies. It is submitted that intellectual property law reform should promote climate justice in line with Mary Robinson’s Declaration on Climate Justice 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A teaching laboratory experiment is described that uses Archimedes’ principle to precisely investigate the effect of global warming on the oceans. A large component of sea level rise is due to the increase in the volume of water due to the decrease in water density with increasing temperature. Water close to 0 °C is placed in a beaker and a glass marble hung from an electronic balance immersed in the water. As the water warms, the weight of the marble increases as the water is less buoyant due to the decrease in density. In the experiment performed in this paper a balance with a precision of 0.1 mg was used with a marble 40.0 cm3 and mass of 99.3 g, yielding water density measurements with an average error of -0.008 ± 0.011%.