Resumo:
Three molecularly imprinted monolithic columns with different length but almost identical column volume had been prepared. It was observed that the separation factors of diastereomers and enantiomers were almost unaffected by column length. However, the short column with dimension of 38 mm x 8 mm W. showed much lower resistance to flow rate so that it could be operated at much higher flow rates. By combining stepwise gradient elution with elevated flow rate, the diastereomers of cinchonine and cinchonidine and the enantiomers of Cbz-DL-Trp and Fmoc-DL-Trp were successfully separated within 3 min on the short column with dimension of 38 mm. x 8 mm i.d.. Based on the above results, a cinchonine imprinted monolithic disk with dimension of 10 mm x 16 mm W. was further developed. The SEM image and the pore size distribution profile showed that large flow-through pores are present on the prepared monolith, which allowed mobile phase to flow through the disk with very low resistance. Chromatographic performances on the monolithic disk were almost unchanged compared with the long columns. A rapid separation of cinchonine and cinchonidine was achieved in 2.5 min at the flow rate of 9.0 ml/min. Furthermore, it was observed that there was almost no effect of the flow rate on the dynamic binding capacity at high flow rates. In addition, the effect of the loading concentration of analytes on the dynamic binding capacity, namely adsorption isotherm, was also investigated. A non-linear adsorption isotherm of cinchonine was observed on the molecularly imprinted monolith with cinchonine as template, which might be a main reason to result in the peak tailing of template molecule. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.
Resumo:
Monolithic columns of capillary electrochromatography (CEC) with weak electroosmotic flow (EOF) have been prepared by in situ polymerization of butyl methacrylate and ethylene dimethacrylate, without any charged groups in the reaction mixture. The reproducibility of such columns has been proved good no matter whether they are prepared in the same batch or in different batches. In the case of BMA-EDMA monoliths, besides the traditional ternary mixture - 1-propanol, 1,4-butanediol, and water, binary porogenic solvents with only alcohols have also been adopted. Compared with ternary porogenic solvents, the design with binary ones allows for fine control of the pore diameter and the formation of the specific surface of the monolithic polymers. The composition of porogenic reagents has also been shown to have an effect on EOF in the column systems. In addition, the Joule heat effect in such columns has been studied by varying the inner diameter of columns. Through the separation of acidic compounds, monolithic columns with low EOF have shown potential in the analysis of charged samples.
Resumo:
Through leaching experiments and simulated rainfall experiments, characteristics of vertical leaching of exogenous rare earth elements (REEs) and phosphorus (P) and their losses with surface runoff during simulated rainfall in different types of soils (terra nera soil, cinnamon soil, red soil, loess soil, and purple soil) were investigated. Results of the leaching experiments showed that vertical transports of REEs and P were relatively low, with transport depths less than 6 cm. The vertical leaching rates of REEs and P in the different soils followed the order of purple soil > terra nera soil > red soil > cinnamon soil > loess soil. Results of the simulated rainfall experiments (83 mm h(-1)) revealed that more than 92% of REEs and P transported with soil particles in runoff. The loss rates of REEs and P in surface runoff in the different soil types were in the order of loess soil > terra nera soil > cinnamon soil > red soil > purple soil. The total amounts of losses of REEs and P in runoff were significantly correlated.
Resumo:
Reversed-phase high-performance liquid chromatographic (RP-HPLC) retention parameters, which are determined by the intermolecular interactions in retention process, can be considered as the chemical molecular descriptors in linear free energy relationships (LFERs). On the basis of the characterization and comparison of octadecyl-bonded silica gel (ODS), cyano-bonded silica gel (CN), and phenyl-bonded silica gel (Ph) columns with linear solvation energy relationships (LSERs), a new multiple linear regression model using RP-HPLC retention parameters on ODS and CN columns as variables for estimation of soil adsorption coefficients was developed. It was tested on a set of reference substances from various chemical classes. The results showed that the multicolumn method was more promising than a single-column method was for the estimation of soil adsorption coefficients. The accuracy of the suggested model is identical with that of LSERs.