557 resultados para waveform


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Co-deposition of nickel and cobalt was carried out on austenitic stainless steel (AISI 304) substrates by imposing a square waveform current in the cathodic region. The innovative procedure applied in this work allows creating a stable, fully developed, and open porous three-dimensional (3D) dendritic structure, which can be used as electrode for redox supercapacitors. This study investigates in detail the influence of the applied current density on the morphology, mass, and chemical composition of the deposited Ni-Co films and the resulting 3D porous network dendritic structure. The morphology and the physicochemical composition were studied by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (W). The electrochemical behavior of the materials was evaluated by cyclic voltammetry (CV). The results highlight the mechanism involved in the coelectrodeposition process and how the lower limit current density tailors the film composition and morphology, as well as its electrochemical activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The latest medical diagnosis devices enable the performance of e-diagnosis making the access to these services easier, faster and available in remote areas. However this imposes new communications and data interchange challenges. In this paper a new XML based format for storing cardiac signals and related information is presented. The proposed structure encompasses data acquisition devices, patient information, data description, pathological diagnosis and waveform annotation. When compared with similar purpose formats several advantages arise. Besides the full integrated data model it may also be noted the available geographical references for e-diagnosis, the multi stream data description, the ability to handle several simultaneous devices, the possibility of independent waveform annotation and a HL7 compliant structure for common contents. These features represent an enhanced integration with existent systems and an improved flexibility for cardiac data representation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is important to have better evaluation and understanding of the motor neuron physiology, with the goal to early and objectively diagnose and treat patients with neurodegenerative pathologies. The Compound Muscle Action Potential (CMAP) scan is a non-invasive diagnosis technique for neurodegenerative pathologies, such as ALS, and enables a quick analysis of the muscle action potentials in response to motor nerve stimulation. This work aims to study the influence of different pulse modulated waveforms in peripheral nerve excitability by CMAP scan technique on healthy subjects. A total of 13 healthy subjects were submitted to the same test. The stimuli were applied in the medium nerve on the right wrist and electromyography signal collected on the Abductor Pollicis Brevis (APB) muscle surface on the right thumb. Stimulation was performed with an increasing intensities range from 4 to 30 mA, with varying steps, 3 stimuli per step. The procedure was repeated 4 times per subject, each repetition using a different single pulse stimulation waveform: monophasic square, monophasic triangular, monophasic quadratic and biphasic square. Results were retrieved from the averaging of the stimuli on each current intensity step. The square pulse needs less current intensity to generate the same response amplitude regarding the other waves and presents a more steep curve slope and this effect is gradually decreasing for the triangular and quadratic pulse,respectively, being the difference even more evident regarding the biphasic pulse. The control of the waveform stimulation pulse allows varying the stimulusresponse curve slope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use, manipulation and application of electrical currents, as a controlled interference mechanism in the human body system, is currently a strong source of motivation to researchers in areas such as clinical, sports, neuroscience, amongst others. In electrical stimulation (ES), the current applied to tissue is traditionally controlled concerning stimulation amplitude, frequency and pulse-width. The main drawbacks of the transcutaneous ES are the rapid fatigue induction and the high discomfort induced by the non-selective activation of nervous fibers. There are, however, electrophysiological parameters whose response, like the response to different stimulation waveforms, polarity or a personalized charge control, is still unknown. The study of the following questions is of great importance: What is the physiological effect of the electric pulse parametrization concerning charge, waveform and polarity? Does the effect change with the clinical condition of the subjects? The parametrization influence on muscle recruitment can retard fatigue onset? Can parametrization enable fiber selectivity, optimizing the motor fibers recruitment rather than the nervous fibers, reducing contraction discomfort? Current hardware solutions lack flexibility at the level of stimulation control and physiological response assessment. To answer these questions, a miniaturized, portable and wireless controlled device with ES functions and full integration with a generic biosignals acquisition platform has been created. Hardware was also developed to provide complete freedom for controlling the applied current with respect to the waveform, polarity, frequency, amplitude, pulse-width and duration. The impact of the methodologies developed is successfully applied and evaluated in the contexts of fundamental electrophysiology, psycho-motor rehabilitation and neuromuscular disorders diagnosis. This PhD project was carried out in the Physics Department of Faculty of Sciences and Technology (FCT-UNL), in straight collaboration with PLUX - Wireless Biosignals S.A. company and co-funded by the Foundation for Science and Technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The case of a patient with gastric adenocarcinoma with indication for gastrectomy is reported. The surgery took place without complications. A palliative, subtotal gastrectomy was performed after para-aortic lymph nodes compromised by neoplasm were found, which was confirmed by pathological exam of frozen sections carried out during the intervention. At the end of the gastroenteroanastomosis procedure, the patient began to show intense bradycardia: 38 beats per minute (bpm), arterial hypotension, changes in the electrocardiogram's waveform (upper unlevelling of segment ST), and cardiac arrest. Resuscitation maneuvers were performed with temporary success. Subsequently, the patient had another circulatory breakdown and again was recovered. Finally, the third cardiac arrest proved to be irreversible, and the intra-operative death occurred. Necropsy showed massive pulmonary embolism. The medical literature has recommended heparinization of patients, in an attempt to avoid pulmonary thromboembolism following major surgical interventions. However, in the present case, heparinization would have been insufficient to prevent death. This case indicates that it is necessary to develop preoperative propedeutics for diagnosing the presence of venous thrombi with potential to migrate, causing pulmonary thromboembolism (PTE). If such thrombi could be detected, preventative measures, such as filter installation in the Cava vein could be undertaken.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a three-phase three-level fast battery charger for electric vehicles (EVs) based in a current-source converter (CSC). Compared with the traditional voltage-source converters used for fast battery chargers, the CSC can be seen as a natural buck-type converter, i.e., the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. Moreover, using the CSC it is not necessary to use a dc-dc back-end converter in the battery side, and it is also possible to control the grid current in order to obtain a sinusoidal waveform, and in phase with the power grid voltage (unitary power factor). Along the paper is described in detail the proposed CSC for EVs fast battery charging systems: the circuit topology, the power control theory, the current control strategy and the grid synchronization algorithm. Several simulation results of the EV fast battery charger operating with a maximum power of 50 kW are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In modern society, thiamine deficiency (TD) remains an important medical condition linked to altered cardiac function. There have been contradictory reports about the impact of TD on heart physiology, especially in the context of cardiac excitability. In order to address this particular question, we used a TD rat model and patch-clamp technique to investigate the electrical properties of isolated cardiomyocytes from epicardium and endocardium. Neither cell type showed substantial differences on the action potential waveform and transient outward potassium current. Based on our results we can conclude that TD does not induce major electrical remodeling in isolated cardiac myocytes in either endocardium or epicardium cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada a la University of Wales, Bangor, Regne Unit entre setembre i desembre del 2006. Els sons distractors augmenten el temps de reacció i el nombre de respostes incorrectes en una tasca de classificació visual, demostrant que hi ha distracció conductual durant la realització de la tasca visual. L’enregistrament concomitant de potencials evocats durant la distracció mostra un patró neuroelèctric característic, el potencial de distracció, que es caracteritza per una ona trifàsica. Darrerament, s’ha demostrat que factors “des de dalt” associats al muntatge experimental tindrien una gran influència en els efectes que els estímuls distractors tindrien en la tasca. Estudis recents mostrarien que aquesta resposta d’atenció exògena es pot modular per la càrrega en memòria de treball, reduint-ne la distracció amb la càrrega, fet que contradiu altres dades que mostraven l’efecte oposat. L’objectiu d’aquest estudi ha estat investigar en quines condicions la càrrega en memòria de treball pot exercir un efecte modulador en les respostes conductuals i cerebrals als sons novedosos distractors, i establir la dinàmica espacio-temporal d’aquesta modulació.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While the dynamics of lexical-semantic and lexical-phonological encoding in word production have been investigated in several event-related potential (ERP) studies, the estimated time course of phonological-phonetic encoding is the result of rather indirect evidence. We investigated the dynamics of phonological-phonetic encoding combining ERP analyses covering the entire encoding process in picture naming and word reading tasks by comparing ERP modulations in eight brain-damaged speakers presenting impaired phonological-phonetic encoding relative to 16 healthy controls. ERPs diverged between groups in terms of local waveform amplitude and global topography at ∼400ms after stimulus onset in the picture naming task and at ∼320-350ms in word reading and sustained until 100ms before articulation onset. These divergences appeared in later time windows than those found in patients with underlying lexical-semantic and lexical-phonological impairment in previous studies, providing evidence that phonological-phonetic encoding is engaged around 400ms in picture naming and around 330ms in word reading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because we live in an extremely complex social environment, people require the ability to memorize hundreds or thousands of social stimuli. The aim of this study was to investigate the effect of multiple repetitions on the processing of names and faces varying in terms of pre-experimental familiarity. We measured both behavioral and electrophysiological responses to self-, famous and unknown names and faces in three phases of the experiment (in every phase, each type of stimuli was repeated a pre-determined number of times). We found that the negative brain potential in posterior scalp sites observed approximately 170 ms after the stimulus onset (N170) was insensitive to pre-experimental familiarity but showed slight enhancement with each repetition. The negative wave in the inferior-temporal regions observed at approximately 250 ms (N250) was affected by both pre-experimental (famous>unknown) and intra-experimental familiarity (the more repetitions, the larger N250). In addition, N170 and N250 for names were larger in the left inferior-temporal region, whereas right-hemispheric or bilateral patterns of activity for faces were observed. The subsequent presentations of famous and unknown names and faces were also associated with higher amplitudes of the positive waveform in the central-parietal sites analyzed in the 320-900 ms time-window (P300). In contrast, P300 remained unchanged after the subsequent presentations of self-name and self-face. Moreover, the P300 for unknown faces grew more quickly than for unknown names. The latter suggests that the process of learning faces is more effective than learning names, possibly because faces carry more semantic information.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Working memory, the ability to store and simultaneously manipulate information, is affected in several neuropsychiatric disorders which lead to severe cognitive and functional deficits. An electrophysiological marker for this process could help identify early cerebral function abnormalities. In subjects performing working memory-specific n-back tasks, event-related potential analysis revealed a positive-negative waveform (PNwm) component modulated in amplitude by working memory load. It occurs in the expected time range for this process, 140-280 ms after stimulus onset, superimposed on the classical P200 and N200 components. Independent Component Analysis extracted two functional components with latencies and topographical scalp distributions similar to the PNwm. Our results imply that the PNwm represents a new electrophysiological index for working memory load in humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We explore in depth the validity of a recently proposed scaling law for earthquake inter-event time distributions in the case of the Southern California, using the waveform cross-correlation catalog of Shearer et al. Two statistical tests are used: on the one hand, the standard two-sample Kolmogorov-Smirnov test is in agreement with the scaling of the distributions. On the other hand, the one-sample Kolmogorov-Smirnov statistic complemented with Monte Carlo simulation of the inter-event times, as done by Clauset et al., supports the validity of the gamma distribution as a simple model of the scaling function appearing on the scaling law, for rescaled inter-event times above 0.01, except for the largest data set (magnitude greater than 2). A discussion of these results is provided.