921 resultados para waste heat recovery system
Resumo:
The relation between the intercepted light and orchard productivity was considered linear, although this dependence seems to be more subordinate to planting system rather than light intensity. At whole plant level not always the increase of irradiance determines productivity improvement. One of the reasons can be the plant intrinsic un-efficiency in using energy. Generally in full light only the 5 – 10% of the total incoming energy is allocated to net photosynthesis. Therefore preserving or improving this efficiency becomes pivotal for scientist and fruit growers. Even tough a conspicuous energy amount is reflected or transmitted, plants can not avoid to absorb photons in excess. The chlorophyll over-excitation promotes the reactive species production increasing the photoinhibition risks. The dangerous consequences of photoinhibition forced plants to evolve a complex and multilevel machine able to dissipate the energy excess quenching heat (Non Photochemical Quenching), moving electrons (water-water cycle , cyclic transport around PSI, glutathione-ascorbate cycle and photorespiration) and scavenging the generated reactive species. The price plants must pay for this equipment is the use of CO2 and reducing power with a consequent decrease of the photosynthetic efficiency, both because some photons are not used for carboxylation and an effective CO2 and reducing power loss occurs. Net photosynthesis increases with light until the saturation point, additional PPFD doesn’t improve carboxylation but it rises the efficiency of the alternative pathways in energy dissipation but also ROS production and photoinhibition risks. The wide photo-protective apparatus, although is not able to cope with the excessive incoming energy, therefore photodamage occurs. Each event increasing the photon pressure and/or decreasing the efficiency of the described photo-protective mechanisms (i.e. thermal stress, water and nutritional deficiency) can emphasize the photoinhibition. Likely in nature a small amount of not damaged photosystems is found because of the effective, efficient and energy consuming recovery system. Since the damaged PSII is quickly repaired with energy expense, it would be interesting to investigate how much PSII recovery costs to plant productivity. This PhD. dissertation purposes to improve the knowledge about the several strategies accomplished for managing the incoming energy and the light excess implication on photo-damage in peach. The thesis is organized in three scientific units. In the first section a new rapid, non-intrusive, whole tissue and universal technique for functional PSII determination was implemented and validated on different kinds of plants as C3 and C4 species, woody and herbaceous plants, wild type and Chlorophyll b-less mutant and monocot and dicot plants. In the second unit, using a “singular” experimental orchard named “Asymmetric orchard”, the relation between light environment and photosynthetic performance, water use and photoinhibition was investigated in peach at whole plant level, furthermore the effect of photon pressure variation on energy management was considered on single leaf. In the third section the quenching analysis method suggested by Kornyeyev and Hendrickson (2007) was validate on peach. Afterwards it was applied in the field where the influence of moderate light and water reduction on peach photosynthetic performances, water requirements, energy management and photoinhibition was studied. Using solar energy as fuel for life plant is intrinsically suicidal since the high constant photodamage risk. This dissertation would try to highlight the complex relation existing between plant, in particular peach, and light analysing the principal strategies plants developed to manage the incoming light for deriving the maximal benefits as possible minimizing the risks. In the first instance the new method proposed for functional PSII determination based on P700 redox kinetics seems to be a valid, non intrusive, universal and field-applicable technique, even because it is able to measure in deep the whole leaf tissue rather than the first leaf layers as fluorescence. Fluorescence Fv/Fm parameter gives a good estimate of functional PSII but only when data obtained by ad-axial and ab-axial leaf surface are averaged. In addition to this method the energy quenching analysis proposed by Kornyeyev and Hendrickson (2007), combined with the photosynthesis model proposed by von Caemmerer (2000) is a forceful tool to analyse and study, even in the field, the relation between plant and environmental factors such as water, temperature but first of all light. “Asymmetric” training system is a good way to study light energy, photosynthetic performance and water use relations in the field. At whole plant level net carboxylation increases with PPFD reaching a saturating point. Light excess rather than improve photosynthesis may emphasize water and thermal stress leading to stomatal limitation. Furthermore too much light does not promote net carboxylation improvement but PSII damage, in fact in the most light exposed plants about 50-60% of the total PSII is inactivated. At single leaf level, net carboxylation increases till saturation point (1000 – 1200 μmolm-2s-1) and light excess is dissipated by non photochemical quenching and non net carboxylative transports. The latter follows a quite similar pattern of Pn/PPFD curve reaching the saturation point at almost the same photon flux density. At middle-low irradiance NPQ seems to be lumen pH limited because the incoming photon pressure is not enough to generate the optimum lumen pH for violaxanthin de-epoxidase (VDE) full activation. Peach leaves try to cope with the light excess increasing the non net carboxylative transports. While PPFD rises the xanthophyll cycle is more and more activated and the rate of non net carboxylative transports is reduced. Some of these alternative transports, such as the water-water cycle, the cyclic transport around the PSI and the glutathione-ascorbate cycle are able to generate additional H+ in lumen in order to support the VDE activation when light can be limiting. Moreover the alternative transports seems to be involved as an important dissipative way when high temperature and sub-optimal conductance emphasize the photoinhibition risks. In peach, a moderate water and light reduction does not determine net carboxylation decrease but, diminishing the incoming light and the environmental evapo-transpiration request, stomatal conductance decreases, improving water use efficiency. Therefore lowering light intensity till not limiting levels, water could be saved not compromising net photosynthesis. The quenching analysis is able to partition absorbed energy in the several utilization, photoprotection and photo-oxidation pathways. When recovery is permitted only few PSII remained un-repaired, although more net PSII damage is recorded in plants placed in full light. Even in this experiment, in over saturating light the main dissipation pathway is the non photochemical quenching; at middle-low irradiance it seems to be pH limited and other transports, such as photorespiration and alternative transports, are used to support photoprotection and to contribute for creating the optimal trans-thylakoidal ΔpH for violaxanthin de-epoxidase. These alternative pathways become the main quenching mechanisms at very low light environment. Another aspect pointed out by this study is the role of NPQ as dissipative pathway when conductance becomes severely limiting. The evidence that in nature a small amount of damaged PSII is seen indicates the presence of an effective and efficient recovery mechanism that masks the real photodamage occurring during the day. At single leaf level, when repair is not allowed leaves in full light are two fold more photoinhibited than the shaded ones. Therefore light in excess of the photosynthetic optima does not promote net carboxylation but increases water loss and PSII damage. The more is photoinhibition the more must be the photosystems to be repaired and consequently the energy and dry matter to allocate in this essential activity. Since above the saturation point net photosynthesis is constant while photoinhibition increases it would be interesting to investigate how photodamage costs in terms of tree productivity. An other aspect of pivotal importance to be further widened is the combined influence of light and other environmental parameters, like water status, temperature and nutrition on peach light, water and phtosyntate management.
Resumo:
La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).
Resumo:
Compilation of published and unpublished resource recovery and waste reduction information; most developed by the EPA.
Resumo:
Jan. 1979.
Resumo:
Cover title.
Resumo:
The last few years have witnessed an unprecedented increase in the price of energy available to industry in the United Kingdom and worldwide. The steel industry, as a major consumer of energy delivered in U.K. (8% of national total and nearly 25% of industrial total) and whose energy costs currently form some 28% of the total manufacturing cost, is very much aware of the need to conserve energy. Because of the complexities of steelmaking processes it is imperative that a full understanding of each process and its interlinking role in an integrated steelworks is understood. An analysis of energy distribution shows that as much as 70% of heat input is dissipated to the environment in a variety of forms. Of these, waste gases offer the best potential for energy conservation. The study identifies areas for and discusses novel methods of energy conservation in each process. Application of these schemes in BSC works is developed and their economic incentives highlighted. A major part of this thesis describes design, development and testing of a novel ceramic rotary regenerator for heat recovery from high temperature waste gases, where no such system is available. The regenerator is a compact, efficient heat exchanger. Application of such a system to a reheating furnace provides a fuel saving of up to 40%. A mathematical model developed is verified on the pilot plant. The results obtained confirm the success of the concept and material selection and outlines the work needed to develop an industrial unit. Last, but not least, the key position of an energy manager in an energy conservation programme is identified and a new Energy Management Model for the BSC is developed.
Resumo:
In a pilot project an optimized mobile latent heat storage based on a system available on the market has been tested at Fraunhofer Institute for Environmental, Safety and Energy Technology. Initially trials were conducted with the aim of optimizing the process of charging and discharging. A specifically constructed test rig at the incineration trials centre at the institute allowed charging and discharging procedures of the mobile latent heat storage with adjustable parameters. In addition an evaluation model was constructed to further optimize the heat exchanger systems. In conclusion the prototype of the mobile latent heat storage was tested in practical operation. The economic and technical feasibility of heat transportation was shown if not utilized waste heat is available. © 2014 The Authors.
Resumo:
In brackish groundwater desalination, high recovery ratio (of fresh water from saline feed) is desired to minimise concentrate reject. To this effect, previous studies have developed a batch reverse osmosis (RO) desalination system, DesaLink, which proposed to expand steam in a reciprocating piston cylinder and transmit the driving force through a linkage crank mechanism to pressurise batches of saline water (recirculating) in a water piston cylinder unto RO membranes. However, steam is largely disadvantaged at operation from low temperature (< 150oC) thermal sources; and organic working fluids are more viable, though, the obtainable thermal cycle efficiencies are generally low with low temperatures. Consequently, this thesis proposed to investigate the use of organic working fluid Rankine cycle (ORC) with isothermal expansion, to drive the DesaLink machine, at improved thermal efficiency from low temperature thermal sources. Following a review of the methods of achieving isothermal expansion, ‘liquid flooded expansion’ and ‘expansion chamber surface heating’ were identified as potential alternative methods. Preliminary experimental comparative analysis of variants of the heated expansion chamber technique of effecting isothermal expansion favoured a heated plain wall technique, and as such was adopted for further optimisation and development. Further, an optimised isothermal ORC engine was built and tested at < 95oC heat source temperature, with R245fa working fluid – which was selected from 16 working fluids that were analysed for isothermal operation. Upon satisfactory performance of the test engine, a larger (10 times) version was built and coupled to drive the DesaLink system. Operating the integrated ORC-RO DesaLink system, gave freshwater (approximately 500 ppm) production of about 12 litres per hour (from 4000 ppm feed water) at a recovery ratio of about 0.7 and specific energy consumption of 0.34 kWh/m3; and at a thermal efficiency of 7.7%. Theoretical models characterising the operation and performance of the integrated system was developed and utilised to access the potential field performance of the system, when powered by two different thermal energy sources – solar and industrial bakery waste heat – as case studies.
Resumo:
Shortages in supply of nutrients and freshwater for a growing human population are critical global issues. Traditional centralized sewage treatment can prevent eutrophication and provide sanitation, but is neither efficient nor sustainable in terms of water and resources. Source separation of household wastes, combined with decentralized resource recovery, presents a novel approach to solve these issues. Urine contains within 1 % of household waste water up to 80 % of the nitrogen (N) and 50 % of the phosphorus (P). Since microalgae are efficient at nutrient uptake, growing these organisms in urine might be a promising technology to concomitantly clean urine and produce valuable biomass containing the major plant nutrients. While state-of-the-art suspension systems for algal cultivation have mayor shortcomings in their application, immobilized cultivation on Porous Substrate Photobioreactors (PSBRs) might be a feasible alternative. The aim of this study was to develop a robust process for nutrient recovery from minimally diluted human urine using microalgae on PSBRs. The green alga Desmodesmus abundans strain CCAC 3496 was chosen for its good growth, after screening 96 algal strains derived from urine-specific isolations and culture collections. Treatment of urine, 1:1 diluted with tap water and without addition of nutrients, was performed at a light intensity of 600 μmol photons m-2 s-1 with 2.5 % CO2 and at pH 6.5. A growth rate of 7.2 g dry weight m-² day-1 and removal efficiencies for N and P of 13.1 % and 94.1 %, respectively, were determined. Pre-treatment of urine with activated carbon was found to eliminate possible detrimental effects of pharmaceuticals. These results provide a basis for further development of the technology at pilot-scale. If found to be safe in terms human and environmental health, the biomass produced from three persons could provide the P for annual production of 31 kg wheat grain and 16 kg soybean, covering the caloric demand in food for almost one month of the year for such a household. In combination with other technologies, PSBRs could thus be applied in a decentralized resource recovery system, contributing to locally close the link between sanitation and food production.
Resumo:
Biomass Refinery is a sequential of eleven thermochemical processes and one biological process with two initial basic treatments: prehydrolysis for lignocellulosics and low temperature conversion for biomass with medium-to-high content of lipids and proteins. The other ten processes are: effluent treatment plant, furfural plant, biodiesel plant, cellulignin dryer, calcination, fluidized bed boiler, authotermal reforming of cellulignin for syngas production, combined cycle of two-stroke low-speed engine or syngas turbine with fluidized bed boiler heat recovery, GTL technologies and ethanol from cellulose, prehydrolysate and syngas. Any kind of biomass such as wood, agricultural residues, municipal solid waste, seeds, cakes, sludges, excrements and used tires can be processed at the Biomass Refinery. Twelve basic products are generated such as cellulignin, animal feed, electric energy, fuels (ethanol, crude oil, biodiesel, char), petrochemical substitutes, some materials (ash, gypsum, fertilizers, silica, carbon black) and hydrogen. The technology is clean with recovery of energy and reuse of water, acid and effluents. Based on a holistic integration of various disciplines Biomass Refinery maximizes the simultaneous production of food, electric energy, liquid fuels and chemical products and some materials, achieving a competitive position with conventional and fossil fuel technologies, as well as payment capacity for biomass production. Biomass Refinery has a technical economical capability to complement the depletion of the conventional petroleum sources and to capture its GHGs resulting a biomass + petroleum ""green"" combination.
Resumo:
Dissertação de Mestrado, Ambiente, Saúde e Segurança, 18 de Fevereiro de 2011, Universidade dos Açores.
Resumo:
Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Mestrado em Engenharia Química. Ramo optimização energética na indústria química.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
The differentiation of non-integer order has its origin in the seventeenth century, but only in the last two decades appeared the first applications in the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated namely the fractional PID and the Smith predictor. Extensive simulations are presented assessing the performance of the proposed fractional-order algorithms.