626 resultados para ventilação
Resumo:
Quasi-experimental study, prospective with quantitative approach, performed at the Hospital do Coração in Natal, aimed at verified the existence of difference between the care given by health professionals to the patients under mechanical ventilation (MV) in the Intensive Care Unit, before and after an educative intervention. The population was of 31 professionals, with data collected between november 05 of 2007 to march 27 of 2008. The results show a yong population, female gender, middle level of education, nursing technique, working between 05 and 09 years on nursing profession, and 01 to 04 years on Intensive Care Unit; almost all, never had an kind of training over prevent pneumonia associated to mechanical ventilation; from those that had training, occur on the work place with duration from 12 to 24 hours. About endotracheal intubation, the cuff was tested with a sterilized syringe had a positive change after a educative intervention, increased from 75,0% to 100,0%; the sterile guide was used on 75,0% before and 100,0% after an educative intervention. Regarding endotracheal suction procedure, was not informed to the patient on 72,7% before, however was informed on 56,7% after; the hands was not previously washed 68,5% before, however was 63,3% after the procedure; mask was used on 74,2 % opportunities before and 76,7% after; the aspiration catheter had adequated size on 98,9% observation before and 100,0% after; the gaze was sterilized on 95,7% before and 100,0% after; the ventilator was connected to the patient during the aspiration intervals on 94,4% observation before and 100,0% after; the ambu bag was clean and protected on 76,1% before and 85,7% after; the aspiration catheter was discarded after be used on 98,9% before and 100,0% after; FIO2 was turned to the begging value on 32,9% observation before and 12,0% after; before the procedure 71,9% professions washed their hands and 73,3% after; before, notes of aspiration results were performed on 70,8% observation and 86,7% after. Regarding devices used on respiratory tract, aspirator flasks were not swapped on 84,6% observations before and 71,0% after; daily látex extention change was not performed on 93,6% observation before and 87,1% after; the ambu bag change was not performed on 50,0% observation before even if was duty or unprotected and on 75,8% opportunities was changed, after; nebulization was not prepared with sterile fluids or manipulated aseptically on 65,2% observation before, perhaps was on 71,7% after; before nebulizers were not changed on 65,2% observations, perhaps were on 60,9% after. Concerning ventilator breathing circuits, condense fluids cumulated on circuits were removed on 55,0% opportunities before, and 64,0% after; moisturizer was not filled with sterile water when already had small amount of liquid inside on 78,4% observations before, and 90,2% after; MV circuits were changed on 97,0% observations on presence of visible duty or when presents some kind of failure, before and 98,4% after. About body position, on 51,3% observations the decubitus position change were done before and 78,2% after; fowler position was maitened on 95,5% observations before and 98,2% after; Regarding respiratory physiotherapy, enteral diet was not interrupted before respiratory physiotherapy on 94,9% before and 90,0% after; respiratory physiotherapy devices were not disinfected or sterile on 69,6% observations before but they re on 60,0% after; before the cateter was not tested before introduction enteral diet or medications on 100,0% but after was done on 15,2%. About enteral feeding, intestine motility and measure of stomach contents were not done on 100,0% observations before, but was 15,2% after. We conclude that 05 of 07 valuated procedures in relation to MV, had a significant improvement on quality of care given after educative intervention, when compared before intervention
Resumo:
Este estudo objetivou atualizar os conhecimentos em relação à utilização da ventilação mecânica não-invasiva (VMNI) no pós-operatório de cirurgia cardíaca e identificar se há indícios da superioridade de uma forma de modalidade de VMNI em relação à outra. Foi realizada revisão da literatura entre 2006 a 2011, a partir das bases de dados PubMed, SciELO e Lilacs, utilizando os descritores respiração artificial, pressão positiva contínua nas vias aéreas, ventilação com pressão positiva intermitente e cirurgia cardíaca, e seus correspondentes na língua inglesa, os quais foram pesquisados em cruzamentos. A partir dos critérios adotados, foram selecionados nove artigos, dos quais seis demonstraram aplicações de VMNI, por meio de modalidades como pressão positiva contínua nas vias aéreas, pressão positiva com dois níveis pressóricos e respiração com pressão positiva intermitente, no pós-operatório de cirurgia cardíaca, e, três realizaram comparações entre as diferentes modalidades. As modalidades de VMNI descritas na literatura foram utilizadas com resultados satisfatórios. Estudos que comparam diferentes modalidades são escassos, contudo alguns demonstraram superioridade de uma modalidade de VMNI, como é o caso da respiração com pressão positiva intermitente na reversão da hipoxemia e da pressão positiva com dois níveis pressóricos na melhora da oxigenação, da frequência respiratória e frequência cardíaca desses pacientes, em comparação a outras modalidades.
Resumo:
The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory
Resumo:
INTRODUCTION: Cardiac and pulmonary manifestations of the Chagas disease (CD) affect between 20-30% of the infected subjects. The chronic Chagas cardiomyopathy (CCC) has some peculiarities such as arrhythmias and, especially heart failure (HF) and is potentially lethal due to left ventricular dysfunction. How respiratory disorders, patients get progressive loss of functional capacity, which contributes to a poor quality of life related to disease. Measurements of lung volume by the movement of the chest wall surface are an alternative evaluation of lung function and kinematics of complex thoracoabdominal for these patients. OBJECTIVE: evaluate the kinematics of the thoracoabdominal complex through the regional pulmonary volumes and to correlate with functional evaluation of the cardiorrespiratory system in patients with Chagas disease at rest. MATERIALS AND METHODS: a cross-section study with 42 subjects had been divided in 3 groups, 15 composed for patients with CCC, 12 patients with HF of different etiologies and 15 healthful presented control group. An optoelectronic plethysmography (POE), Minnesota questionnaire, six minute walk test, spirometer and manovacuometer was used. RESULTS: It was observed in the 6MWT where group CRL presented greater distance 464,93±44,63m versus Group HF with 399,58± 32,1m (p=0,005) and group CCC 404±68,24m (p=0,015), both the groups presented difference statistics with regard to Group CRL. In the manovacuometer 54,59±19,98; of the group CCC and 42,11±13,52 of group IC found group CRL presented 81,31±15,25 of the predicted versus, presenting in relation to group CRL. In the POE it observed a major contribution in abdominal compartment in patients with IC if compared like CCC and control groups. On the basis of the questionnaire of quality of life of Minessota, verified a low one groups CCC and IC 43,2±15,2 and 44,4±13,1, respectively (p<0,05) when compared with the control group (19,6±17,31). CONCLUSION: it seems that the patients with CCC possess same functional and respiratory characteristics, observed for the POE, 6MWT, manovacuometer and spirometer to the patients of group HF, being able to consider similar interventions for this complementary group as therapeutical of this neglected disease
Resumo:
JUSTIFICATIVA E OBJETIVOS: em pacientes sob intubação traqueal ou traqueostomia, a umidificação e o aquecimento do gás inalado são necessários para a prevenção de lesões no sistema respiratório, conseqüentes ao contato do gás frio e seco com as vias aéreas. O objetivo da pesquisa foi avaliar o efeito do sistema respiratório circular com absorvedor de dióxido de carbono do aparelho de anestesia Cícero da Dräger, quanto à capacidade de aquecimento e umidificação dos gases inalados, utilizando-se fluxo baixo (1 L.min-1) ou mínimo (0,5 L.min-1) de gases frescos. MÉTODO: O estudo aleatório foi realizado em 24 pacientes, estado físico ASA I, com idades entre 18 e 65 anos, submetidos à anestesia geral, utilizando-se a Estação de Trabalho Cícero da Dräger (Alemanha), para realização de cirurgias abdominais, os quais foram distribuídos aleatoriamente em dois grupos: grupo de Baixo Fluxo (BF), no qual foi administrado 0,5 L.min-1 de oxigênio e 0,5 L.min-1 de óxido nitroso e fluxo mínimo (FM), administrando-se somente oxigênio a 0,5 L.min-1. Os atributos estudados foram temperatura, umidade relativa e absoluta da sala de operação e do gás no sistema inspiratório. RESULTADOS: Os valores da temperatura, umidade relativa e umidade absoluta no sistema inspiratório na saída do aparelho de anestesia e junto ao tubo traqueal não apresentaram diferença significante entre os grupos, mas aumentaram ao longo do tempo nos dois grupos (BF e FM), havendo influência da temperatura da sala de operação sobre a temperatura do gás inalado, nos dois grupos estudados. Níveis de umidade e temperatura próximos dos ideais foram alcançados, nos dois grupos, a partir de 90 minutos. CONCLUSÕES: Não há diferença significante da umidade e temperatura do gás inalado utilizando-se baixo fluxo e fluxo mínimo de gases frescos.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: the purpose of this study was to determine the effects of prone positioning on cardiorespiratory stability and weaning outcome of preterm infants during weaning from mechanical ventilation. Methods: from January to December 1999, a sample of 42 preterm infants, with birthweight < 2,000 g, mechanically ventilated in the first week of life, were randomly divided, in the beginning of the weaning process, in two groups according to the position: supine position (n = 21) or prone position (n = 21). Heart rate, respiratory rate, transcutaneous oxygen saturation and ventilatory parameters were recorded every one hour. Length of the weaning process and complications were also assessed. Results: in both groups the mean gestational age was 29 weeks, most of the patients presented very low birthweight and respiratory distress syndrome. The mean length of the weaning process was 2 days. There were no differences between the groups regarding respiratory rate, heart rate and transcutaneous oxygen saturation, however, oxygen desaturation episodes were more frequent in supine position (p = 0.009). Ventilatory parameters decreased faster and reintubation was less frequent in the prone group (4% versus 33%). No adverse effects of prone positioning were observed. Conclusion: these results suggest that prone position is a safe and beneficial procedure during the weaning from mechanical ventilation and may contribute to weaning success in preterm infants.
Resumo:
BACKGROUND AND OBJECTIVES: Pressure controlled ventilation (PCV) is available in anesthesia machines, but there are no studies on its use during CO 2 pneumoperitoneum (CPP). This study aimed at evaluating pressure-controlled ventilation and hemodynamic and ventilatory changes during CPP, as compared to conventional volume controlled ventilation (VCV). METHODS: This study involved 16 dogs anesthetized with thiopental, fentanyl and pancuronium, which were randomly assigned to two groups: VC - volume controlled ventilation (n=8) and PC - pressure controlled ventilation (n=8). Hemodynamic and ventilatory parameters were monitored and recorded in 4 moments: M1 (before CPP), M2 (30 minutes after CPP = 10 mmHg), M3 (30 minutes after CPP=15 mmHg) and M4 (30 minutes after deflation). RESULTS: With CPP, there has been significant increase in tidal volume in PC group; there has been increase in airway pressures (peak and plateau), decrease in compliance with increase in CPP pressure, increase in heart rate, maintenance of mean blood pressure with higher values in the VC group in all stages; there was also increase in right atrium pressure with significant decrease after deflation, decrease in arterial pH with minor variations in PC group, greater arterial pCO 2 stability in PC group, and no significant changes in arterial pO 2. CONCLUSIONS: There were some differences in hemodynamic and ventilatory data between both ventilation control modes (VC and PC). It is possible to use pressure controlled ventilation during CPP, but the anesthesiologist must monitor and take a close look at alveolar ventilation, adjusting inspiratory pressure to ensure proper CO 2 elimination and oxygenation. © Sociedade Brasileira de Anestesiologia, 2005.
Resumo:
The effects of several inspired oxygen fractions (FiO 2) on the respiratory dynamics in spontaneously breathing dogs submitted to continuous infusion of propofol were evaluated. Eight adult mongrel dogs were used. Each animal underwent five anesthesias, in each procedure the patient was allowed to breath a different FiO 2, thereby resulting in five groups, namely: G100 (FiO 2 = 1), G80 (FiO 2 = 0.8), G60 (FiO 2 =0.6), G40 (FiO 2 = 0.4), and G20 (FiO 2 = 0.21). To induce anesthesia, propofol was given until the animals allowed orotracheal intubation, followed by immediate continuous infusion of drug. The initial measurement (M0) was recorded thirty minutes after the infusion of propofol has begun. Additional recordings were performed at 15 minute intervals for 60 minutes (M15, M30, M45 and M60). Numeric data were submitted to Analysis of Variance followed by Tukey Test (p<0.05). We recorded significantly lower values of SpO 2 and SaO 2 at G20, whereas PaO 2 varied according to the changes in oxygen. Regarding PaCO 2, the mean of G100 was greater than G20 at M30. However, spontaneously breathing dogs anesthetized with propofol at the rate of 0.7mg/kg/min should not be provided with 100%, 80%, and 21% oxygen owing to the significant compromise of respiratory system.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB