793 resultados para varicose-veins
Resumo:
BACKGROUND Rapid pulmonary vein (PV) activity has been shown to maintain paroxysmal atrial fibrillation (AF). We evaluated in persistent AF the cycle length (CL) gradient between PVs and the left atrium (LA) in an attempt to identify the subset of patients where PVs play an important role. METHODS AND RESULTS Ninety-seven consecutive patients undergoing first ablation for persistent AF were studied. For each PV, the CL of the fastest activation was assessed over 1 minute (PVfast) using Lasso recordings. The PV to LA CL gradient was quantified by the ratio of PVfast to LA appendage (LAA) AF CL. Stepwise ablation terminated AF in 73 patients (75%). In the AF termination group, the PVfast CL was much shorter than the LAA CL resulting in lower PVfast/LAA ratios compared with the nontermination group (71±10% versus 92±7%; P<0.001). Within the termination group, PVfast/LAA ratios were notably lower if AF terminated after PV isolation or limited adjunctive substrate ablation compared with patients who required moderate or extensive ablation (63±6% versus 75±8%; P<0.001). PVfast/LAA ratio <69% predicted AF termination after PV isolation or limited substrate ablation with 74% positive predictive value and 95% negative predictive value. After a mean follow-up of 29±17 months, freedom from arrhythmia recurrence off-antiarrhythmic drugs was achieved in most patients with PVfast/LAA ratios <69% as opposed to the remaining population (80% versus 43%; P<0.001). CONCLUSIONS The PV to LA CL gradient may identify the subset of patients in whom persistent AF is likely to terminate after PV isolation or limited substrate ablation and better long-term outcomes are achieved.
Resumo:
AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.
Resumo:
We examined small-scale shear zones in drillcore samples of abyssal peridotites from the Mid-Atlantic Ridge. These shear zones are associated with veins consisting of chlorite + actinolite/tremolite assemblages, with accessory phases zircon and apatite, and they are interpreted as altered plagiogranite melt impregnations, which originate from hydrous partial melting of gabbroic intrusion in an oceanic detachment fault. Ti-in-zircon thermometry yields temperatures around 820°C for the crystallization of the evolved melt. Reaction path modeling indicates that the alteration assemblage includes serpentine of the adjacent altered peridotites. Based on the model results, we propose that formation of chlorite occurred at higher temperatures than serpentinization, thus leading to strain localization around former plagiogranites during alteration. The detachment fault represents a major pathway for fluids through the oceanic crust, as evidenced by extremely low d18O of altered plagiogranite veins (+3.0-4.2 per mil) and adjacent serpentinites (+ 2.6-3.7 per mil). The uniform oxygen isotope data indicate that fluid flow in the detachment fault system affected veins and adjacent host serpentinites likewise.
Resumo:
Numerous veins are present in basalts recovered from Hole 462A, Leg 61 of the Deep Sea Drilling Project. Three mineral assemblages are recognized and stratigraphically controlled. These assemblages are (1) a zeolite-bearing, quartz-poor assemblage which occurs from Core 44 to the bottom of the hole and contains smectite, clinoptilolite, calcite, pyrite, ± chabazite, ± analcime, ± quartz, ± apophyllite, ± talc (?); (2) a quartz-rich, pyrite-bearing assemblage, found between Cores 19 and 29, which contains smectite, calcite, quartz, and pyrite; and (3) a quartz-rich, celadonite-bearing assemblage which occurs from Cores 14 through 17 and contains smectite, calcite, quartz, celadonite, and Fe oxide. These data are interpreted to represent two episodes of vein mineral formation with an oxidative overprint on the more recent. The first episode followed the outpourings of basaltic lavas onto the sea floor. Zeolite-bearing veins were formed at elevated temperatures under low PCO2 while the thermal gradient was high and before a cover of calcareous sediments had formed. The second mineralization episode followed injection of basalt and microdiabase sills into a thick layer of sediments, and produced all the vein minerals now occurring between Cores 14 and 29. These veins formed at lower temperature and higher PCO2 than zeolite-bearing veins. The presence of pyrite indicates a nonoxidative environment. After the initial formation of these veins, oxygenated seawater diffused through the sedimentary cover and oxidized the pyrite and smectite, forming celadonite and Fe oxides.
Resumo:
In situ secondary ionization mass spectrometry (SIMS) analyses of oxygen isotopes in authigenic calcite veins were obtained from an active thrust fault system drilled at Ocean Drilling Program (ODP) Site 892 (44°40.4'N, 125°07.1'W) along the Cascadia subduction margin. The average d18OPDB value of all samples is -9.9 per mil and the values are the lowest of any measured in active accretionary prisms. Ranges in individual veins can be as much as 19.6 per mil. There is an isotopic stratigraphy related to the structural stratigraphy. Mean isotope values in the hanging wall, thrust, and footwall are -14.4 per mil, -9.5 per mil, and -5.2 per mil, respectively. Several veins and crosscutting vein sequences show a general trend from lower to higher d18O values over time. Isotopic and textural data indicate several veins formed by a crack-seal mechanism and growth into open fractures. The best explanation for the strong 18O depletions is periodic rapid flow from 2-3 km deeper in the prism. Relatively narrow isotopic ranges for most veins suggest that fluids were derived from a similar source depth for each episode of fluid pulse and calcite crystallization. Structural and mass balance considerations are consistent with a record preserved in the veins of ten to hundreds of thousands of years. The fluid pulses may relate to periodic large earthquake events such as those recognized in the paleoseismicity records from the Cascadia margin.
Resumo:
The Athabasca Basin (Canada) contains the highest grade unconformity-type uranium deposits in the world. Underlying the Athabasca Group sedimentary rocks of the Dufferin Lake zone are variably graphitic pelitic schists (VGPS), altered to chlorite and hematite (Red/Green Zone: RGZ), and locally bleached near the unconformity during paleoweathering and/or later fluid interaction, leading to a loss of graphite near the unconformity. Fluid inclusions were examined in different generations of quartz veins, using microthermometry and Raman analysis, to characterize and compare the different fluids that interacted with the RGZ and the VGPS. In the VGPS, CH4-, N2- and CO2-rich fluids circulated. CH4- and N2-rich fluids could be the result of the breakdown of graphite to CH4/CO2, whereas N2-rich fluid is interpreted to be the result of breakdown of feldspars/micas to NH4+/N2. In the RGZ, highly saline fluids interpreted to be basinally derived have been recorded. The circulation of the two types of fluids (carbonic and brines) occurred at two different distinct events: 1) during the retrograde metamorphism of the basement rocks before the deposition of the Athabasca Basin for the carbonic fluids, and 2) after the deposition of the Athabasca Basin for the brines. Thus, in addition to possibly be related to graphite depletion in the RGZ, the brines can be linked to uranium mineralization.