859 resultados para variable speed


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this master thesis is to test according to hoisting requirements, a servo drive system and compare its performance with the performance of a drive equipped with a vector controlled frequency converter. Both systems utilize closed-loop vector control based on PCL program control. In order to compare the results of tests both systems were connected to the same motor driving a variable speed electrical chain hoist. Tests were based on requirements to both systems. As requirements of tests zero speed operation, operation in field weakening, positioning accuracy and smoothness of motion are taken into consideration. Both systems demonstrate quite similar performance and meet the requirements. Servo drive system demonstrates a high positioning accuracy and dynamic performance. Frequency converter is not able to provide the same positioning accuracy and dynamic performance as servo drive.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Centrifugal pumps are a notable end-consumer of electrical energy. Typical application of a centrifugal pump is the filling or emptying of a reservoir tank, where the pump is often operated at a constant speed until the process is completed. Installing a frequency converter to control the motor substitutes the traditional fixed-speed pumping system, allows the optimization of rotational speed profile for the pumping tasks and enables the estimation of rotational speed and shaft torque of an induction motor without any additional measurements from the motor shaft. Utilization of variable-speed operation provides the possibility to decrease the overall energy consumption of the pumping task. The static head of the pumping process may change during the pumping task. In such systems, the minimum rotational speed changes during reservoir filling or emptying, and the minimum energy consumption can’t be achieved with a fixed rotational speed. This thesis presents embedded algorithms to automatically identify, optimize and monitor pumping processes between supply and destination reservoirs, and evaluates the changing static head –based optimization method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Centrifugal pumps are one of the major energy consuming end-devices in developed coun-tries both in industrial and services sectors. According to recent studies, even 30 % of the energy used in pumping systems could be saved by more careful choosing of devices and system design. One of the most efficient and affordable ways to decrease the energy con-sumption of the pumping system is to substitute traditionally used flow control methods, like valve control, with modern variable speed drive (VSD) control. In this thesis, Microsoft Excel based program, Savings Calculator for Centrifugal Pumps (SCCP), is designed. SCCP calculates the achievable energy and financial savings when throttle control is substituted by VSD control in the pumping system. Compared to the sim-ilar existing programs, the goal is to make SCCP calculations more accurate and require less input information. Also some useful additional features are added to the designed program to make it more user friendly. The reliability of the calculations of designed program seem to vary depending on case. The results are corresponding accurately to the laboratory measurements, but there occurs high deviations in some cases, when the results are compared to the pump information specified by manufacturer. On the basis of verification in this thesis, SCCP seems to be at least as accurate as similar existing programs and it can be used as help in investment decision whether to have VSD or not.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Wind is one of the most compelling forms of indirect solar energy. Available now, the conversion of wind power into electricity is and will continue to be an important element of energy self-sufficiency planning. This paper is one in a series intended to report on the development of a new type of generator for wind energy; a compact, high-power, direct-drive permanent magnet synchronous generator (DD-PMSG) that uses direct liquid cooling (LC) of the stator windings to manage Joule heating losses. The main param-eters of the subject LC DD-PMSG are 8 MW, 3.3 kV, and 11 Hz. The stator winding is cooled directly by deionized water, which flows through the continuous hollow conductor of each stator tooth-coil winding. The design of the machine is to a large degree subordinate to the use of these solid-copper tooth-coils. Both steady-state and timedependent temperature distributions for LC DD-PMSG were examined with calculations based on a lumpedparameter thermal model, which makes it possible to account for uneven heat loss distribution in the stator conductors and the conductor cooling system. Transient calculations reveal the copper winding temperature distribution for an example duty cycle during variable-speed wind turbine operation. The cooling performance of the liquid cooled tooth-coil design was predicted via finite element analysis. An instrumented cooling loop featuring a pair of LC tooth-coils embedded in a lamination stack was built and laboratory tested to verify the analytical model. Predicted and measured results were in agreement, confirming the predicted satisfactory operation of the LC DD-PMSG cooling technology approach as a whole.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, bromelain was recovered from ground pineapple stem and rind by means of precipitation with alcohol at low temperature. Bromelain is the name of a group of powerful protein-digesting, or proteolytic, enzymes that are particularly useful for reducing muscle and tissue inflammation and as a digestive aid. Temperature control is crucial to avoid irreversible protein denaturation and consequently to improve the quality of the enzyme recovered. The process was carried out alternatively in two fed-batch pilot tanks: a glass tank and a stainless steel tank. Aliquots containing 100 mL of pineapple aqueous extract were fed into the tank. Inside the jacketed tank, the protein was exposed to unsteady operating conditions during the addition of the precipitating agent (ethanol 99.5%) because the dilution ratio "aqueous extract to ethanol" and heat transfer area changed. The coolant flow rate was manipulated through a variable speed pump. Fine tuned conventional and adaptive PID controllers were on-line implemented using a fieldbus digital control system. The processing performance efficiency was enhanced and so was the quality (enzyme activity) of the product.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis investigates the pressure-based control of a variable-speed-driven pump system in the case of existing output pressure measurement and in the case of sensorless system, where the actual output pressure value is calculated with the steady state estimator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pumping, fan and compressor systems consume most of the motor electricity power in both the industrial and services sectors. A variable speed drive brings relevant improvements in a fluid system leading to energy saving that further on can be translated into Mtons reduction of CO 2 emissions. Standards and regulations are being adopted for fluid handling systems to limit the less efficiency pumps out of the European market on the coming years and a greater potential in energy savings is dictated by the Energy Efficiency Index (EEI) requirements for the whole pumping system and integrated pumps. Electric motors also have an International Efficiency (IE) classification in order to introduce higher efficiency motors into the market. In this thesis, the applicability of mid-size common electric motor types to industrial pumping system took place comparing the motor efficiency characteristics with each other and by analyzing the effect of motor dimensioning on the pumping system and its impact in the energy consumption.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Seit gut zehn Jahren erlebt die Windenergienutzung in Deutschland einen in der Mitte der 80er Jahre nicht für möglich gehaltenen Aufschwung. Anlagenanzahl und installierte Leistung haben in diesem Zeitraum mit durchschnittlichen jährlichen Wachstumsraten von mehr als 30 Prozent zugenommen, die mittlere installierte Leistung pro neu errichteter Anlage stieg dabei um das Zehnfache und die technische Verfügbarkeit der Anlagen liegt mittlerweile bei über 98 Prozent. Mit größer werdenden Anlagen zeigt sich weiterhin ein klarer Trend zu Blattwinkel verstellbaren Konzepten, mit zunehmend drehzahlvariabler Betriebsweise. Vor dem von Vielen für die kommenden drei bis sechs Jahre prognostizierten Einstieg in die großtechnische Offshore- Windenergienutzung mit den damit verbundenen immensen technologischen und strukturellen Herausforderungen erscheint es sinnvoll, einen kritischen Blick zurückzuwerfen auf die 90er Jahre mit den ihnen zugrunde liegenden förderpolitischen Rahmenbedingungen. Dabei soll die Frage beantwortet werden, welchen konkreten Einfluss die staatlichen Forschungs- und Förderprogramme, besonders das "250 MW Wind"-Programm, auf die Entwicklung der Windenergienutzung hatten, das heißt, unter welchen Bedingungen sich bestimmte Techniklinien durchsetzten, wie der Einfluss eines geschützten Marktes durch gesetzlich garantierte Einspeisetarife auf diese Entwicklung zu bewerten ist und schließlich, welche Fehlentwicklungen möglicher Weise eingetreten sind. Dazu wird mit Hilfe von Lernkurven gezeigt, welche Kostenreduktionen insgesamt erzielt wurden, wie hoch die dazu notwendigen staatlichen Finanzmittel waren und welche Schlussfolgerungen daraus für die Zukunft abgeleitet werden können. Die Arbeit soll insgesamt dazu beitragen, die erreichten technischen Entwicklungsschritte vor dem Hintergrund der förderpolitischen Gegebenheiten besser zu verstehen, Chancen für gezielte Änderungen in der Förderpraxis zu ergreifen und Hinweise auf die Ausgestaltung von zukünftigen Forschungsprogrammen und Entwicklungsschwerpunkten im Bereich der Windenergie zu geben, um weitere Kostensenkungspotenziale auszuschöpfen. Dabei wird sich die zukünftige Schwerpunktsetzung in der programmatischen Ausrichtung der Forschung stärker auf die drei wichtigsten Anwendungsfelder für Windenergieanlagen konzentrieren müssen, die großtechnische Offshore- Anwendung, die netzgebundene, dezentrale Energieversorgung sowie auf Windenergieanlagen zur ländlichen Elektrifizierung in autonomen Versorgungssystemen für Schwellen- und Entwicklungsländer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Energy efficiency and renewable energy use are two main priorities leading to industrial sustainability nowadays according to European Steel Technology Platform (ESTP). Modernization efforts can be done by industries to improve energy consumptions of the production lines. These days, steel making industrial applications are energy and emission intensive. It was estimated that over the past years, energy consumption and corresponding CO2 generation has increased steadily reaching approximately 338.15 parts per million in august 2010 [1]. These kinds of facts and statistics have introduced a lot of room for improvement in energy efficiency for industrial applications through modernization and use of renewable energy sources such as solar Photovoltaic Systems (PV).The purpose of this thesis work is to make a preliminary design and simulation of the solar photovoltaic system which would attempt to cover the energy demand of the initial part of the pickling line hydraulic system at the SSAB steel plant. For this purpose, the energy consumptions of this hydraulic system would be studied and evaluated and a general analysis of the hydraulic and control components performance would be done which would yield a proper set of guidelines contributing towards future energy savings. The results of the energy efficiency analysis showed that the initial part of the pickling line hydraulic system worked with a low efficiency of 3.3%. Results of general analysis showed that hydraulic accumulators of 650 liter size should be used by the initial part pickling line system in combination with a one pump delivery of 100 l/min. Based on this, one PV system can deliver energy to an AC motor-pump set covering 17.6% of total energy and another PV system can supply a DC hydraulic pump substituting 26.7% of the demand. The first system used 290 m2 area of the roof and was sized as 40 kWp, the second used 109 m2 and was sized as 15.2 kWp. It was concluded that the reason for the low efficiency was the oversized design of the system. Incremental modernization efforts could help to improve the hydraulic system energy efficiency and make the design of the solar photovoltaic system realistically possible. Two types of PV systems where analyzed in the thesis work. A method was found calculating the load simulation sequence based on the energy efficiency studies to help in the PV system simulations. Hydraulic accumulators integrated into the pickling line worked as energy storage when being charged by the PV system as well.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reviews the effectiveness of vehicle activated signs. Vehicle activated signs are being reportedly used in recent years to display dynamic information to road users on an individual basis in order to give a warning or inform about a specific event. Vehicle activated signs are triggered individually by vehicles when a certain criteria is met. An example of such criteria is to trigger a speed limit sign when the driver exceeds a pre-set threshold speed. The preset threshold is usually set to a constant value which is often equal, or relative, to the speed limit on a particular road segment. This review examines in detail the basis for the configuration of the existing sign types in previous studies and explores the relation between the configuration of the sign and their impact on driver behavior and sign efficiency. Most of previous studies showed that these signs have significant impact on driver behavior, traffic safety and traffic efficiency. In most cases the signs deployed have yielded reductions in mean speeds, in speed variation and in longer headways. However most experiments reported within the area were performed with the signs set to a certain static configuration within applicable conditions. Since some of the aforementioned factors are dynamic in nature, it is felt that the configurations of these signs were thus not carefully considered by previous researchers and there is no clear statement in the previous studies describing the relationship between the trigger value and its consequences under different conditions. Bearing in mind that different designs of vehicle activated signs can give a different impact under certain conditions of road, traffic and weather conditions the current work suggests that variable speed thresholds should be considered instead.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The progressing cavity pump artificial lift system, PCP, is a main lift system used in oil production industry. As this artificial lift application grows the knowledge of it s dynamics behavior, the application of automatic control and the developing of equipment selection design specialist systems are more useful. This work presents tools for dynamic analysis, control technics and a specialist system for selecting lift equipments for this artificial lift technology. The PCP artificial lift system consists of a progressing cavity pump installed downhole in the production tubing edge. The pump consists of two parts, a stator and a rotor, and is set in motion by the rotation of the rotor transmitted through a rod string installed in the tubing. The surface equipment generates and transmits the rotation to the rod string. First, is presented the developing of a complete mathematical dynamic model of PCP system. This model is simplified for use in several conditions, including steady state for sizing PCP equipments, like pump, rod string and drive head. This model is used to implement a computer simulator able to help in system analysis and to operates as a well with a controller and allows testing and developing of control algorithms. The next developing applies control technics to PCP system to optimize pumping velocity to achieve productivity and durability of downhole components. The mathematical model is linearized to apply conventional control technics including observability and controllability of the system and develop design rules for PI controller. Stability conditions are stated for operation point of the system. A fuzzy rule-based control system are developed from a PI controller using a inference machine based on Mandami operators. The fuzzy logic is applied to develop a specialist system that selects PCP equipments too. The developed technics to simulate and the linearized model was used in an actual well where a control system is installed. This control system consists of a pump intake pressure sensor, an industrial controller and a variable speed drive. The PI control was applied and fuzzy controller was applied to optimize simulated and actual well operation and the results was compared. The simulated and actual open loop response was compared to validate simulation. A case study was accomplished to validate equipment selection specialist system