424 resultados para transfemoral osseointegration
Resumo:
Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.
Resumo:
Objective: This study aimed at investigating the influence of the porous titanium (Ti) structure on the osteogenic cell behaviour. Materials and methods: Porous Ti discs were fabricated by the powder metallurgy process with the pore size typically between 50 and 400 mm and a porosity of 60%. Osteogenic cells obtained from human alveolar bone were cultured until subconfluence and subcultured on dense Ti (control) and porous Ti for periods of up to 17 days. Results: Cultures grown on porous Ti exhibited increased cell proliferation and total protein content, and lower levels of alkaline phosphatase (ALP) activity than on dense Ti. In general, gene expression of osteoblastic markers-runt-related transcription factor 2, collagen type I, alkaline phosphatase, bone morphogenetic protein-7, and osteocalcin was lower at day 7 and higher at day 17 in cultures grown on porous Ti compared with dense Ti, a finding consistent with the enhanced growth rate for such cultures. The amount of mineralized matrix was greater on porous Ti compared with the dense one. Conclusion: These results indicate that the porous Ti is an appropriate substrate for osteogenic cell adhesion, proliferation, and production of a mineralized matrix. Because of the three-dimensional environment it provides, porous Ti should be considered an advantageous substrate for promoting desirable implant surface-bone interactions.
Resumo:
The aim of the present study was to evaluate the in vitro osteogenic potential of subcultured human osteoblastic cells derived from alveolar bone on a titanium (Ti) surface produced by an anodized alkali treatment (BSP-AK). Primary osteoblastic cells were subcultured on BSP-AK and machined Ti discs (control) and grown for periods of up to 21 days under osteogenic conditions. Morphologic and biochemical methods were used to assess important parameters of in vitro bone-like tissue formation. Although no major differences were observed between the BSP-AK and the control Ti surface in terms of cell attachment and mineralized matrix formation, a significant increase in cell population, ALP activity, and collagen content was detected in cultures on BSP-AK surface. Our results demonstrate that human osteoblastic cells are sensitive to the BSP-AK-modified Ti surface during the transitional stage between the end of the proliferative phase and the onset of the differentiation /matrix maturation ones. Together with the good mechanical properties exhibited by the Ca- and P- coating, our findings suggest that BSP-AK treatment could be useful for the development of a new surface for dental and orthopedic implants. (c) 2008 Wiley Periodicals, Inc.J Biomed Mater Res 88A: 841-848, 2009
Resumo:
Despite wide clinical application, the efficacy of platelet-rich plasma (PRP) for repairing bone defects and enhancing osseointegration of metal implants is still subject of debate. This study aimed to evaluate the effects of a well-defined PRP-like mixture containing platelet-derived growth factor-BB, transforming growth factor (TGF)-beta 1, TGF-beta 2, albumin, fibronectin, and thrombospondin [growth factors (GFs) + proteins] on the development of the osteogenic phenotype on titanium (Ti) in vitro. Human alveolar bone-derived osteoblastic cells were subcultured on Ti discs and exposed during the first 7 days to osteogenic medium supplemented with GFs + proteins and to osteogenic medium alone thereafter up to 14 days. Control cultures were exposed to only osteogenic medium. Dose-response experiments were carried out using rat primary calvarial cells exposed to GFs + proteins and 1:10 or 1:100 dilutions of the mixture. Treated human-derived cell cultures exhibited a significantly higher number of cycling cells at days 1 and 4 and of total cells at days 4 and 7, significantly reduced alkaline phosphatase (ALP) activity at days 4, 7, and 10, and no Alizarin red-stained areas (calcium deposits) at day 14, indicating an impairment in osteoblast differentiation. Although the 1:10 and 1:100 dilutions of the mixture restored the proliferative activity of rat-derived osteogenic cells to control levels and promoted a significant increase in ALP activity at day 10 compared with GFs + proteins, mineralized nodule formation was only observed with the 1:100 dilution (similar to 50% of the control). These results showed that a PRP-like protein mixture inhibits development of the osteogenic phenotype in both human and rat osteoblastic cell cultures grown on Ti. (J Histochem Cytochem 57:265-276, 2009)
Electromagnetic tracker feasibility in the design of a dental superstructure for edentulous patients
Resumo:
The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.
Resumo:
The weak fixation of biomaterials within the bone structure is one of the major reasons of implants failures. Calcium phosphate (CaP) coatings are used in bone tissue engineering to improve implant osseointegration by enhancing cellular adhesion, proliferation and differentiation, leading to a tight and stable junction between implant and host bone. It has also been observed that materials compatible with bone tissue either have a CaP coating or develop such a calcified surface upon implantation. Thus, the development of bioactive coatings becomes essential for further improvement of integration with the surrounding tissue. However, most of current applied CaP coatings methods (e.g. physical vapor deposition), cannot be applied to complex shapes and porous implants, provide poor structural control over the coating and prevent incorporation of bioactive organic compounds (e.g. antibiotics, growth factors) because of the used harsh processing conditions. Layer-by-layer (LbL) is a versatile technology that permits the building-up of multilayered polyelectrolyte films in mild conditions based on the alternate adsorption of cationic and anionic elements that can integrate bioactive compounds. As it is recognized in natureâ s biomineralization process the presence of an organic template to induce mineral deposition, this work investigate a ion based biomimetic method where all the process is based on LbL methodology made of weak natural-origin polyelectrolytes. A nanostructured multilayer component, with 5 or 10 bilayers, was produced initially using chitosan and chondroitin sulphate polyelectrolyte biopolymers, which possess similarities with the extracellular matrix and good biocompatibility. The multilayers are then rinsed with a sequential passing of solutions containing Ca2+ and PO43- ions. The formation of CaP over the polyelectrolyte multilayers was confirmed by QCM-D, SEM and EDX. The outcomes show that 10 polyelectrolyte bilayer condition behaved as a better site for initiating the formation of CaP as the precipitation occur at earlier stages than in 5 polyelectrolyte bilayers one. This denotes that higher number of bilayers could hold the CaP crystals more efficiently. This work achieved uniform coatings that can be applied to any surface with access to the liquid media in a low-temperature method, which potentiates the manufacture of effective bioactive biomaterials with great potential in orthopedic applications.
Resumo:
This thesis is a continuation of the Enterprise-Ireland Research Innovation Fund (RIF) Project entitled’ "Design and Manufacturing of Customised Maxillo-Facial Prostheses" The primary objective of this Internal Research Development Program (IRDP) project was to investigate two fundamental design changes 1 To incorporate the over-denture abutments directly into the implant. 2 To remove the restraining wings by the addition of screws, which affix the. implant to the dense material of the jawbone. The prosthetic was redesigned using the ANSYS Finite Element Analysis software program and analysed to* • Reduce the internal von Mises stress distribution The new prosthetic had a -63.63 % lower von Mises stress distribution when compared with the original prosthetic. • Examine the screw preload effects. A maximum relative displacement of 22 6 * lO^mm between the bone and screw was determined, which is well below the critical threshold of micromotion which prevents osseointegration • Investigate the prosthetic-bone contact interface. Three models of the screw, prosthesis, and bone, were studied. (Axisymmetnc, quarter volume, and full volume), a recommended preload torque of 0 32 Nm was applied to the prosthetic and a maximum von Mises stress of 1.988 MPa was predicted • Study the overdenture removal forces. This analysis could not be completed because the correct plastic multilinear properties of the denture material could not be established The redesigned prosthetic was successfully manufactured on a 3-axis milling machine with an indexing system The prosthetic was examined for dimensional quality and strength The research established the feasibility of the new design and associated manufacturing method.
Resumo:
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
El recanvi de vàlvula aòrtica transcateter (TAVI) és un tècnica quirúrgica mínimanent invasiva que permet tractar l´estenosis aòrtica severa. El present estudi tracta de descriure de forma retrospectiva les característiques perioperatories dels pacients sotmesos a TAVI, així com els resultats obtinguts i complicacions. S'ha realitzat un estudi comparatiu entre abordatge transapical i transfemoral, i entre pacients amb Euroscore&30% i &30%. Amb això pretenem descriure i valorar l'experiència i resultats d'aquest tipus d'intervencions en el nostre centre, i comparar-la amb els resultats obtinguts per altres grups de treball
Resumo:
OBJECTIVE: The aim of this investigation was to improve the hemodynamics during venoarterial bypass by remote decompression of the left ventricle (LV). METHODS: Venoarterial bypass was established in 5 bovine experiments (69+/-10 kg) by the transjugular insertion of a self-expanding cannula (smartcanula) with return through a carotid artery. Cardiogenic shock was simulated with ventricular fibrillation induced by an external stimulator. Left ventricular decompression was achieved by switching to transfemoral drainage of the pulmonary artery (PA) with a long self-expanding cannula. RESULTS: Initial pump flow was 4.7+/-0.9 l/min and the aortic pressure accounted for 75+/-21 mmHg. After induction of ventricular fibrillation, the pump flow dropped after 11+/-8 min to 2.5+/-0.1 l/min. Transfemoral decompression increased the pump flow to 5.6+/-0.7 l/min, while the RV pressure decreased from 27+/-9 to 3+/-5 mmHg, the PA pressure decreased from 29+/-7 to 5+/-4 mmHg, the LV pressure decreased from 29+/-6 to 7+/-2 mmHg, and the aortic pressure increased from 31+/-3 to 47+/-11 mmHg. CONCLUSIONS: Remote drainage of the pulmonary artery during venoarterial bypass allows for effective decompression of the left ventricle and provides superior hemodynamics.
Resumo:
Various compositions of synthetic calcium phosphates (CaP) have been proposed and their use has considerably increased over the past decades. Besides differences in physico-chemical properties, resorption and osseointegration, artificial CaP bone graft might differ in their resistance against biofilm formation. We investigated standardised cylinders of 5 different CaP bone grafts (cyclOS, chronOS (both β-TCP (tricalcium phosphate)), dicalcium phosphate (DCP), calcium-deficient hydroxyapatite (CDHA) and α-TCP). Various physico-chemical characterisations e.g., geometrical density, porosity, and specific surface area were investigated. Biofilm formation was carried out in tryptic soy broth (TSB) and human serum (SE) using Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984). The amount of biofilm was analysed by an established protocol using sonication and microcalorimetry. Physico-chemical characterisation showed marked differences concerning macro- and micropore size, specific surface area and porosity accessible to bacteria between the 5 scaffolds. Biofilm formation was found on all scaffolds and was comparable for α-TCP, chronOS, CDHA and DCP at corresponding time points when the scaffolds were incubated with the same germ and/or growth media, but much lower for cyclOS. This is peculiar because cyclOS had an intermediate porosity, mean pore size, specific surface area, and porosity accessible to bacteria. Our results suggest that biofilm formation is not influenced by a single physico-chemical parameter alone but is a multi-step process influenced by several factors in parallel. Transfer from in vitro data to clinical situations is difficult; thus, advocating the use of cyclOS scaffolds over the four other CaP bone grafts in clinical situations with a high risk of infection cannot be clearly supported based on our data.
Transcatheter aortic valve implantation (TAVI): state of the art techniques and future perspectives.
Resumo:
Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.
Resumo:
Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.
Resumo:
Traditionally, the transcatheter aortic valve replacement is performed through a transapical, a transfemoral or a trans-subclavian approach. Recently, the transaortic approach for transcatheter aortic valve replacement through the distal part of the ascending aorta was successfully implemented in order to avoid peripheral vascular access-related complications and apical life-threatening haemorrhage. The Sapien? stent valve has great transaortic potential because it can be loaded 'upside down' in different generations of delivery systems. However, because of their health regulatory systems and despite the launch, in 2012, of the latest generation of the Ascendra? delivery system, the Ascendra+?, specifically designed for transapical and transaortic valve placements, several countries are still using the first generations of Ascendra? (Ascendra? 1 and 2). This device was specifically designed for transapical procedures, and retrograde stent-valve positioning through the stenotic aortic valve may be very challenging and risk the integrity of the aorta. We describe the manoeuvre required in order to pass the stenotic aortic valve safely in a retrograde direction using the Sapien? stent valve and the first generations of Ascendra?.