959 resultados para total hip prosthesis
Resumo:
The purpose of this study was to evaluate the incidence of corrosion and fretting in 48 retrieved titanium-6aluminum-4vanadium and/or cobalt-chromium-molybdenum modular total hip prosthesis with respect to alloy material microstructure and design parameters. The results revealed vastly different performance results for the wide array of microstructures examined. Severe corrosion/fretting was seen in 100% of as-cast, 24% of low carbon wrought, 9% of high carbon wrought and 5% of solution heat treated cobalt-chrome. Severe corrosion/fretting was observed in 60% of Ti-6Al-4V components. Design features which allow for fluid entry and stagnation, amplification of contact pressure and/or increased micromotion were also shown to play a role. 75% of prosthesis with high femoral head-trunnion offset exhibited poor performance compared to 15% with a low offset. Large femoral heads (>32mm) did not exhibit poor corrosion or fretting. Implantation time was not sufficient to cause poor performance; 54% of prosthesis with greater than 10 years in-vivo demonstrated none or mild corrosion/fretting.
Resumo:
Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.
Resumo:
La sostituzione totale d’anca è uno degli interventi chirurgici con le più alte percentuali di successo. Esistono due varianti di protesi d’anca che differiscono in base al metodo di ancoraggio all’osso: cementate (fissaggio tramite cemento osseo) e non cementate (fissaggio tramite forzamento). Ad oggi, i chirurghi non hanno indicazioni quantitative di supporto per la scelta fra le due tipologie di impianto, decidendo solo in base alla loro esperienza. Due delle problematiche che interessano le protesi non cementate sono la possibilità di frattura intra-operatoria durante l’inserimento forzato e il riassorbimento osseo nel periodo di tempo successivo all’intervento. A partire da rilevazioni densitometriche effettuate su immagini da TC di pazienti sottoposti a protesi d’anca non cementata, sono stati sviluppati due metodi: 1) per la valutazione del rischio di frattura intra-operatorio tramite analisi agli elementi finiti; 2) per la valutazione della variazione di densità minerale ossea (tridimensionalmente attorno alla protesi) dopo un anno dall’operazione. Un campione di 5 pazienti è stato selezionato per testare le procedure. Ciascuno dei pazienti è stato scansionato tramite TC in tre momenti differenti: una acquisita prima dell’operazione (pre-op), le altre due acquisite 24 ore (post 24h) e 1 anno dopo l’operazione (post 1y). I risultati ottenuti hanno confermato la fattibilità di entrambi i metodi, riuscendo inoltre a distinguere e a quantificare delle differenze fra i vari pazienti. La fattibilità di entrambe le metodologie suggerisce la loro possibilità di impiego in ambito clinico: 1) conoscere la stima del rischio di frattura intra-operatorio può servire come strumento di guida per il chirurgo nella scelta dell’impianto protesico ottimale; 2) conoscere la variazione di densità minerale ossea dopo un anno dall’operazione può essere utilizzato come strumento di monitoraggio post-operatorio del paziente.
Resumo:
Summary: Total hip prosthesis, a reasonable treatment for dogs with hip problems
Resumo:
PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.
Resumo:
INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.
Resumo:
This study is a long-term analysis of a group of patients with infected arthroplasties of the hip or the knee. We identified 28 patients with an infected arthroplasty (22 hips, 6 knees) documented by bacterial culture or on direct examination. At the time of diagnosis and on follow-up (a mean of 46 months after treatment) we evaluated the clinical picture, the radiological appearances of the articulation and the biological parameters. 19/28 patients showed a typical clinical picture, whereas in 9 others the picture was more doubtful. The treatments were 14 two-stage replacements of the arthroplasties, 7 simple resections, 5 conservative treatments and 2 one-stage replacements. On follow-up, 25 patients were considered as cured of their infection and 3 as failures. From a functional viewpoint, 9 patients showed no limitation, whereas 19 were limited in the daily activity. Half of the patients had no pain. Radiology showed that 20/26 evaluated patients had no signs of recurrence. Paraclinical examinations are important in the diagnosis of persistent low grade infections, particularly the demonstration of bacteria by pre-surgical sampling (fine needle aspiration, culture from draining sinuses). In spite of the cure of infection, the functional and painful sequellae are often considerable. As a result of our experience, we recommend a two-stage surgical procedure. Only when the general condition of the patient is poor, or when the infection is not under control, would we envisage an alternative procedure (arthrodesis, girdelstone, conservative).
Resumo:
We report a prospective, randomized, multi-center, open-label 2-year trial of 81 postmenopausal women aged 53-79 years with at least one minimal-trauma vertebral fracture (VF) and low (T-score below 2) lumbar bone mineral density (BMD). Group HRT received piperazine estrone sulfate (PES) 0.625 - 1.25 mg/d +/- medroxyprogesterone acetate (MPA) 2.5 - 5 mg/d,- group HRT/D received HRT plus calcitriol 0.25 mug bd. All with a baseline dietary calcium (Ca) of < I g/d received Ca carbonate 0.6 g nocte. Final data were on 66 - 70 patients. On HRT/D, significant (P < 0.001) BNID increases from baseline by DXA were at total body - head, trochanter, Ward's, total hip, inter-trochanter and femoral shaft (% group mean Delta 4.2, 6.1, 9.3. 3.7. 3.3 and 3.3%, respectively). On HRT, at these significant Deltas were restricted to the trochanter and sites. si Wards. Significant advantages of HRT/D over HRT were in BMD of total body (- head), total hip and trochanter (all P = 0.01). The differences in mean Delta at these sites were 1.3, 2.6 and 3.9%. At the following, both groups Improved significantly -lumbar spine (AP and lateral), forearm shaft and ultradistal tibia/fibula. The weightbearing, site - specific benefits of the combination associated with significant suppression of parathyroid hormone-suggest a beneficial effect on cortical bone. Suppression of bone turnover was significantly greater on HRT/D (serum osteocalcin P = 0.024 and urinary hydroxyproline/creatinine ratio P = 0.035). There was no significant difference in the number of patients who developed fresh VFs during the trial (HRT 8/36, 22%; HRT/D 4/34, 12% - intention to treat); likewise in the number who developed incident nonvertebral fractures. This Is the first study comparing the 2 treatments in a fracture population. The results indicate a significant benefit of calcitriol combined with HRT on total body BMD and on BNID at the hip, the major site of osteoporotic fracture.
Resumo:
To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods.
Resumo:
BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.
Resumo:
OBJECTIVE: to characterize the epidemiological profile of patients undergoing hip replacement, primary or revisional. METHODS: we conducted a retrospective, descriptive study, including hip arthroplasties performed from January 2009 to June 2012 in a Belo Horizonte teaching hospital, Minas Gerais State - MG, Brazil. Data were analyzed using descriptive statistics. RESULTS: orthopedic procedures represented 45% of the operations at the hospital in the period, 1.4% hip arthroplasties. There were 125 hip replacements, 85 total, 27 partial and 13 reviews. Among the patients, 40% were male and 60% were female. Age ranged between 20 and 102 years, mean and median of 73 and 76 years, respectively. The most frequent diagnosis (82%) was femoral neck fracture by low-energy trauma caused by falling form standing position. In 13 revision operations, 12 required removal of the prosthesis. The infectious complication led to revision in 54% of the time, followed by dislocation (15%), peri-prosthetic fracture (15%) and aseptic loosening (15%). The infection etiologic agent was identified in 43% of occasions. The average length of the prosthesis to a revision operation was eight months. CONCLUSION: patients undergoing hip arthroplasty are elderly, with femoral neck fracture caused by falling form standing position, affecting more women. The incidence of hip prosthesis loosening was 10%. The main cause of the infection was loosening. The incidence of revisional hip arthroplasty was 10% and the incidence of hospital mortality in patients undergoing hip arthroplasty was 7.2%.