942 resultados para thermal-hydraulic system codes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Often practical performance of analytical redundancy for fault detection and diagnosis is decreased by uncertainties prevailing not only in the system model, but also in the measurements. In this paper, the problem of fault detection is stated as a constraint satisfaction problem over continuous domains with a big number of variables and constraints. This problem can be solved using modal interval analysis and consistency techniques. Consistency techniques are then shown to be particularly efficient to check the consistency of the analytical redundancy relations (ARRs), dealing with uncertain measurements and parameters. Through the work presented in this paper, it can be observed that consistency techniques can be used to increase the performance of a robust fault detection tool, which is based on interval arithmetic. The proposed method is illustrated using a nonlinear dynamic model of a hydraulic system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays utilising the proper HVAC system is essential both in extreme weather conditions and dense buildings design. Hydraulic loops are the most common parts in all air conditioning systems. This article aims to investigate the performance of different hydraulic loop arrangements in variable flow systems. Technical, economic and environmental assessments have been considered in this process. A dynamic system simulation is generated to evaluate the system performance and an economic evaluation is conducted by whole life cost assessment. Moreover, environmental impacts have been studied by considering the whole life energy consumption, CO2 emission, the embodied energy and embodied CO2 of the system components. Finally, decision-making in choosing the most suitable hydraulic system among five well-known alternatives has been proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Captopril (CAP) was the first commercially available angiotensine-converting enzyme (ACE) inhibitor. In the anti-hypertensive therapy is considered the selected drug has to be therapeutically effective together with reduced toxicity. CAP is an antihypertensive drug currently being administered in tablet form. In order to investigate the possible interactions between CAP and excipients in tablets formulations, differential scanning calorimetry (DSC) and thermogravimetric (TG) analysis completed by X-ray powder diffraction (XRPD) and Fourier transform infrared spectroscopy (FTIR) were used for compatibility studies. A possible drug-excipient interaction was observed with magnesium stearate by DSC technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Na pesquisa em erosão, nas últimas décadas, está se formando um consenso de que é importante entender os processos básicos que regem o fenômeno. Uma alternativas para tentar compreender melhor as etapas do processo erosivo é separá-lo na fase de sulco (fluxo concentrado) e de entressulco. Dentro desse enfoque foi construído no Laboratório de Processos Erosivos e Deposicionais (LaPED) do IPH/UFRGS um canal de declividade para estudar o processo de incisão e o desenvolvimento dos sulcos de erosão. A estrutura experimental projetada e construída permite que seja controlada a vazão através de um medidor eletromagnético e que seja alterada a declividade do canal através de um sistema hidráulico associado a um nível digital. O solo colocado no canal foi um Latossolo Vermelho distrófico típico, as declividades de trabalho foram 3,0; 6,0 e 9,0% e a seqüência de vazões aplicadas foi 10,0; 18,5; 25,5; 38,5 e 51,0L.min-1. A estrutura experimental montada se mostrou de fácil operação e eficiente para permitir o avanço no entendimento dos processos de desagregação e de transporte de partículas sólidas pela ação do escoamento superficial, além de possibilitar a geração de sulco(s) de erosão na superfície do solo. O escoamento passou da condição de difuso para concentrado a partir do momento em que a velocidade superficial do fluxo alcançou 0,26m.s-1, a altura de lâmina atingiu 0,0102m, a velocidade de cisalhamento superou os 0,059m.s-1, a tensão de cisalhamento chegou a 3,50Pa e que a potência do escoamento atingiu pelo menos 0,22N.s-1. O processo de incisão iniciou-se com o canal experimental colocado em baixa declividade e em regime de escoamento sub-crítico e de transição. A velocidade de cisalhamento, no momento da incisão, foi, praticamente, o dobro daquela encontrada na literatura para solos siltosos e arenosos. Entretanto, para as três declividades a fase de sulco definido ocorreu somente em regime de escoamento turbulento. A tensão de cisalhamento foi o parâmetro que melhor descreveu a evolução da perda de solo. A potência do escoamento foi o parâmetro hidráulico que mostrou maior eficiência para separar as fases evolutivas dos sulcos. O desenvolvimento do(s) sulco(s) teve o seu início em uma condição de escoamento difuso (ausência de sulcos) e com a potência do escoamento oscilando entre 0,057 e 0,198N.s-1. O avanço do(s) sulco(s) começou com uma zona de transição (fase de incisão e de aprofundamento) onde a potência do escoamento varia entre 0,220 e 0,278N.s-1 e, logo em seguida, teve início a fase de sulco definido, com a potência do escoamento entre 0,314 e 0,544N.s-1. Na fase de escoamento concentrado foi preponderante o papel do processo de erosão regressiva para aumentar tanto o tamanho como o peso das partículas sólidas em transporte pelo escoamento superficial e assim fazer com que predominasse o transporte via fundo sobre o transporte via suspensão. As cargas de sedimento geradas nos solos de diferentes classes texturais foram separadas em grupos distintos em função da potência unitária do escoamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was studied a system for heating water to be used to obtain water for bathing at home, the absorbing surface of the collector is formed by one plate of polycarbonate. The polycarbonate plate has 6 mm thick, 1.050 mm wide and 1.500 mm long with an area equal to 1,575 m². The plate was attached by its edges parallel to PVC tubes of 32 mm. The system worked under the thermo-siphon and was tested for two configurations: plate absorber with and without isolation of EPS of 30 mm thick on the bottom surface in order to minimize heat losses from the bottom. The tank's thermal heating system is alternative and low cost, since it was constructed from a polyethylene reservoir for water storage, with a volume of 200 liters. Will present data on the thermal efficiency, heat loss, water temperature of thermal reservoir at the end of the process simulation and baths. Will be demonstrated the feasibility of thermal, economic and material pickup proposed for the intended purpose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A tangential filtration process was implemented in this study using porous ceramic tubes made of alpha-alumina produced by the slip-casting technique. These tubes were sintered at 1450 degrees C and characterized by mercury intrusion porosimetry, which revealed a mean pore size of 0.5 mu m. The tubes were chemically impregnated with a zirconium citrate solution, after which they were calcined and heat treated at temperatures of up to 600 and 900 degrees C to eliminate volatile organic compounds and transform the zirconium citrate into zirconium oxide impregnated in the alumina in the form of nanoparticle agglomerates. The microporous pipes were tested on a microfiltration hydraulic system to analyze their performance in the demulsification of sunflower oil and water mixtures. The fluid-dynamic parameters of Reynolds number and transmembrane pressure were varied in the process. The volume of permeate was analyzed by measuring the Total Organic Carbon concentration (TOC), which indicated 99% of oil phase retention. The emulsified mixture was characterized by optical microscopy, while the morphology and composition of the impregnated microporous tubes were analyzed by scanning electron microscopy (SEM). Quantification of the TOC values for the tube impregnated once at 600 degrees C showed the best demulsification performance, with the concentration on permeate smaller than 10 mg/L. The impregnated tube sintered once at 900 degrees C presented low carbon concentration (smaller than 20 mg/L), has the advantage of presenting the greatest trans-membrane flux in relation to the other microporous tube. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Classical shell-and-tube heat exchangers are usually equipped with segmental baffles. These baffles serve two basic functions: (a) they provide tube supports, thereby preventing or reducing mechanical problems, such as sagging or vibration; (b) they direct the fluid flow over the tubes so as to introduce a cross-flow component, thereby increasing the heat transfer. Segmented baffles have several sources of performance loss, some due to various leakage flows and others caused by stagnation zones. A new concept of longitudinal flow heat exchanger - based on placing twisted tapes along the tube bundle subchannels - was developed to mitigate drawbacks of other types of tubular heat exchangers. In this paper, a numerical model has been implemented in order to simulate the thermal-hydraulic feature of tubular heat exchangers equipped either with segmental baffles or with subchannel twisted tapes. The tube bundle has been described by means of an equivalent porous medium type model, allowing a macroscopic description of the shell-side flow. The basic equations - continuity, momentum and energy - have been solved by using the finite volume method. Typical numerical results have been compared with experimental data, reaching a very good agreement. A comparative analysis of different types of heat exchangers has been carried out, revealing the satisfactory thermal-hydraulic efficiency level of the twisted tapes heat exchangers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was conducted with the objective to evaluate the duration of exposure of animals to the evaporative cooling system in the waiting barn on the weather variables (temperature and relative humidity), animal behavior, production and quality aspects of milk from Girolando cows. Sixteen multiparous lactating cows were used having a genetic composition of 7/8 Holstein-Gir and mean milk production of 18 kg animal-1day-1. A 4 × 4 Latin square design was used. The experiment was conducted during the summer season (February-March 2009) and lasted 56 days. The treatments consisted of different periods of 10, 20 and 30 minutes of exposure to acclimatization and control. Time of 30 minutes of exposure to thermal conditioning system enabled the second milking (evening shift), providing an increase in milk production in the next milking of 0.640 kg animal-1. A higher percentage of time spent on food intake and rumination (17.31 and 30.19%) in 30 minutes treatment, compared to control (15.50 and 27.37%), respectively. There was no significant effect of treatments in the composition of milk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV