926 resultados para testing method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quality control on fruits requires reliable methods, able to assess with reasonable accuracy and possibly in a non-destructive way their physical and chemical characteristics. More specifically, a decreased firmness indicates the presence of damage or defects in the fruit or else that the fruit has exceeded its “best before date”, becoming unsuitable for consumption. In high-value exotic fruits, such as mangoes, where firmness cannot be easily measured from a simple observation of texture, colour changes and unevenness of fruits surface, the use of non-destructive techniques is highly recommendable. In particular, the application of Laser vibrometry, based on the Doppler effect, a non-contact technique sensitive to differences in displacements inferior to the nanometre, appears ideal for a possible on-line control on food. Previous results indicated that a phase shift can be in a repeatable way associated with the presence of damage on the fruit, whilst a decreased firmness results in significant differences in the displacement of the fruits under the same excitation signal. In this work, frequency ranges for quality control via the application of a sound chirp are suggested, based on the measurement of the signal coherence. The variations of the average vibration spectrum of a grid of points, or of point-by-point signal velocity allows the go-no go recognition of “firm” and “over-ripe” fruits, with notable success in the particular case of mangoes. The future exploitation of this work will include the application of this method to allow on-line control during conveyor belt distribution of fruits.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper deals with the key issues encountered in testing during the development of high-speed networking hardware systems by documenting a practical method for "real-life like" testing. The proposed method is empowered by modern and commonly available Field Programmable Gate Array (FPGA) technology. Innovative application of standard FPGA blocks in combination with reconfigurability are used as a back-bone of the method. A detailed elaboration of the method is given so as to serve as a general reference. The method is fully characterised and compared to alternatives through a case study proving it to be the most efficient and effective one at a reasonable cost.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

If a plastic material is used as a print bearer there are a need of a special surface treatment to get agod and durable printing. The most used surface treatment technique for the moment is coronatreatment. This kind of treatment has unfortunately showed not to be so durable in the long term.Plasma treatment which in this case uses different kind of gases in the treatment of polypropyleneis shown as a more effective treatment in this project. When the plasma treated surface has beenprinted is the good quality last much longer and the adhesion between the ink and the surface isremained. To test this adhesion is for the moment a standard used (ASTM D3359). This standardhas appeared unstable and dependent at many different factors, which gives a big variation in thetest results. Because of this has new test methods been carried out to give a more even and morereliable result in the test of the adhesion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Trinta Candida albicans isoladas de pacientes portadores de candidose oral e 30 Candida albicans isoladas de indivíduos controle foram estudadas. Testes de susceptibilidade in vitro foram realizados com anfotericina B, fluconazol, 5-flucitosina e itraconazol pelo método do Clinical and Laboratorial Standars Institute (CLSI) e por E-test. Os resultados obtidos foram analisados e comparados. Os valores de CIM foram semelhantes para amostras isoladas de pacientes portadores de candidose oral e indivíduos controle. A concordância entre os dois métodos foi de 66,7% para a anfotericina B, 53,33% para o fluconazol, 65% para a flucitosina e 45% para o itraconazol. de acordo com estes resultados, o método do E-test poderia ser uma alternativa para a triagem de casos de rotina pela sua simplicidade. Entretanto, este método não pode ser considerado como um substituto para o método de referência do CLSI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human fungal infections have increased at an alarming rate in recent years, particularly in immunocompromised individuals. Cryptococcosis is the second most prevalent systemic fungal infection worldwide, and the most prevalent systemic infection in immunocompromised individuals, representing more than 70% of cases. The incidence of cryptococcosis is high in people with HIV/acquired immunodeficiency syndrome (AIDS), with recent estimates indicating that there are one million cases of cryptococcal meningitis globally per year in AIDS patients. The aim of this research was to develop a rapid flow cytometric antifungal susceptibility test and to compare the results with the standard methods. A reference strain and clinical isolates of Cryptococcus neoformans and Cryptococcus gattii were tested for susceptibility to amphotericin B by flow cytometry using propidium iodide as indicator of viability. Flow cytometry (FC) results were compared with the minimum inhibitory concentration (MIC) values determined by microdilution. The antifungal activity of amphotericin B ranged from MICs of 0.06 to 2μg/ml for the 11 isolates studied. The same results were found by FC. The FC method allows same-day results, assisting in the selection of appropriate antifungal therapies. These results demonstrate an excellent correlation between FC and the classic methods of testing for susceptibility to antifungal agents. This rapid diagnosis method makes it possible to quickly administer effective therapeutic interventions, often saving lives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Clinical multistage risk assessment associated with electrocardiogram (ECG) and NT-proBNP may be a feasible strategy to screen hypertrophic cardiomyopathy (HCM). We investigated the effectiveness of a screening based on ECG and NT-proBNP in first-degree relatives of patients with HCM. Methods and Results: A total of 106 first-degree relatives were included. All individuals were evaluated by echocardiography, ECG, NT-proBNP, and molecular screening (available for 65 individuals). From the 106 individuals, 36 (34%) had diagnosis confirmed by echocardiography. Using echocardiography as the gold standard, ECG criteria had a sensitivity of 0.71, 0.42, and 0.52 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Mean values of NT-ProBNP were higher in affected as compared with nonaffected relatives (26.1 vs. 1290.5, P < .001). The AUC of NT-proBNP was 0.98. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.92 and specificity of 0.96. Using molecular genetics as the gold standard, ECG criteria had a sensitivity of 0.67, 0.37, and 0.42 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.83 and specificity of 0.98. Conclusion: Values of NT-proBNP above 70 pg/mL can be used to effectively select high-risk first-degree relatives for HCM screening. (J Cardiac Fail 2012;18:564-568)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to determine the rela­tive rate of corrosion of iron-tin alloys containing low percentages of tin. Since in the world today, a great deal of work is being done to develop large tin deposits and new methods devised to treat these ores, it is possible that the metal will become abundant and will obtain a more important position in the metal industry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We investigated if CLSI M27-A2 Candida species breakpoints for fluconazole MIC are valid when read at 24 h. Analysis of a data set showed good correlation between 48- and 24-h MICs, as well as similar outcomes and pharmacodynamic efficacy parameters, except for isolates in the susceptible dose-dependent category, such as Candida glabrata.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An inexpensive device which is easily operated to accurately measure the Coulomb parameters of the soil. The Coulomb parameters are used in Coulomb's equation to calculate the shearing stresses along a failure surface of the soil. The device includes an instrument to test soil shear strength to which several weights have been added. To obtain the Coulomb parameters, the instrument is placed on the soil to be tested and weights are incrementally added to it. The instrument is rotated at each weight increment and the shearing stresses are read from its calibrated dial. The stresses are plotted on a graph from which the Coulomb parameters are determined. The shearing stress of the soil with any known force applied to it can then be determined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bibliography: p. 25.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A procedure for calculating critical level and power of likelihood ratio test, based on a Monte-Carlo simulation method is proposed. General principles of software building for its realization are given. Some examples of its application are shown.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To develop a tool for the accurate reporting and aggregation of findings from each of the multiple methods used in a complex evaluation in an unbiased way. Study Design and Setting: We developed a Method for Aggregating The Reporting of Interventions in Complex Studies (MATRICS) within a gastroenterology study [Evaluating New Innovations in (the delivery and organisation of) Gastrointestinal (GI) endoscopy services by the NHS Modernisation Agency (ENIGMA)]. We subsequently tested it on a different gastroenterology trial [Multi-Institutional Nurse Endoscopy Trial (MINuET)]. We created three layers to define the effects, methods, and findings from ENIGMA. We assigned numbers to each effect in layer 1 and letters to each method in layer 2. We used an alphanumeric code based on layers 1 and 2 to every finding in layer 3 to link the aims, methods, and findings. We illustrated analogous findings by assigning more than one alphanumeric code to a finding. We also showed that more than one effect or method could report the same finding. We presented contradictory findings by listing them in adjacent rows of the MATRICS. Results: MATRICS was useful for the effective synthesis and presentation of findings of the multiple methods from ENIGMA. We subsequently successfully tested it by applying it to the MINuET trial. Conclusion: MATRICS is effective for synthesizing the findings of complex, multiple-method studies.