895 resultados para test retest reliability
Resumo:
Background: The perception of improvement by a patient has assumed a central role in functional evaluation after a variety of knee problems. One of the instruments most used in clinical research is the International Knee Documentation Committee (IKDC) Subjective Knee Form because its psychometric properties are considered to be excellent. Nonetheless, this questionnaire was originally developed for use in the English language. Therefore, to use this questionnaire in the Brazilian population, it is essential to translate and validate it. Purpose: The aim of this study was to translate the IKDC Subjective Knee Form into a Brazilian version and to test its validity and reproducibility. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The translation of the original IKDC Subjective Knee Form into a Brazilian version was accomplished in accordance with the American Orthopaedic Society for Sports Medicine guidelines and was tested in 32 patients with knee pathologic conditions to develop the first Brazilian version. To test validity and reproducibility, 117 patients with several knee complaints completed the Brazilian IKDC Subjective Knee Form, the Short Form 36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm score. From these patients, 85 were retested within a week to achieve reproducibility. The validation was addressed by correlating the Brazilian IKDC Subjective Knee Form to the other outcome measures. The reproducibility was tested by measuring internal consistency, test-retest reliability, and agreement. Results: The Brazilian IKDC Subjective Knee Form was highly related to the physical component summary of the SF-36, the Lysholm score, and the WOMAC, and weakly related to the mental component summary of SF-36 (r=.79, .89, .85, and .51, respectively). The internal consistency was strong, with a Cronbach a value of .928 and .935 in the test and retest assessment, respectively. The test-retest reliability proved to be excellent, with a high value of the intraclass correlation coefficient (.988), as well as the agreement, demonstrated by the low differences between the means of the test and retest, and the short limit of agreement, observed in the Altman-Bland and survival-agreement plots. Conclusion: The results of this study provide evidence that the Brazilian IKDC Subjective Knee Form has psychometric properties similar to the original version. In addition, it was a reliable evaluation instrument for patients with knee-related problems.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objective: In the literature there is no validated instrument for the clinical evaluation of the orofacial myofunctional condition of children that will permit the examiner to express numerically his perception of the characteristics and behaviors observed. The proposal of this study is to describe a protocol for the evaluation of children aged 6-12 years in order to establish relations between the orofacial. myofunctional conditions and numerical scales. The protocol validity, reliability of the examiners and agreement between them was analyzed. Methods: Eighty children aged 6-12 years participated in the study. All were evaluated and 30 were selected at random for the analyses (age range: 72-149 months, mean = 103.3, S.D. = 23.57). Individuals with and without orofacial myofunctional. disorders were included. The examiners were two speech therapists property calibrated in orofacial myofunctional evaluation. Two protocols were constructed. One, based on traditional models, was called traditional orofacial. myofunctional. evaluation (TOME), and the other, with the addition of numerical scales, was called orofacial myofunctional. evaluation with scores (OMES). The clinical conditions included were: appearance, posture and mobility of lips, tongue, cheeks and jaws, respiration, mastication and deglutition. Statistical analysis was performed using the split-half reliability method. Means, standard deviations and the Spearman correlation coefficient were also calculated. Results: There was a statistically significant correlation between the evaluations of 30 children assessed with the TOME and OMES protocols (r = 0.85, p < 0.01). The reliability between protocols was 0.92. The test-retest reliability of the OMES instrument was 0.99 and the correlation was 0.98. Reliability between examiners 1 and 2 using the OMES protocol was 0.99, and the correlation was 0.98 (P < 0.01). Conclusion: The OMES protocot proved to be a valid and reliable instrument for orofacial myofunctional evaluation, permitting the grading of orofacial myofunctional conditions within the limits of the selected items. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The genetic relationship between lower (information processing speed), intermediate (working memory), and higher levels (complex cognitive processes as indexed by IQ) of mental ability was studied in a classical twin design comprising 166 monozygotic and 190 dizygotic twin pairs. Processing speed was measured by a choice reaction time (RT) task (2-, 4-, and 8-choice), working memory by a visual-spatial delayed response task, and IQ by the Multidimensional Aptitude Battery. Multivariate analysis, adjusted for test-retest reliability, showed the presence of a genetic factor influencing all variables and a genetic factor influencing 4- and 8-choice RTs, working memory, and IQ. There were also genetic factors specific to 8-choice RT, working memory, and IQ. The results confirmed a strong relationship between choice RT and IQ (phenotypic correlations: -0.31 to -0.53 in females, -0.32 to -0.56 in males; genotypic correlations: -0.45 to -0.70) and a weaker but significant association between working memory and IQ (phenotypic: 0.26 in females, 0.13 in males; genotypic: 0.34). A significant part of the genetic variance (43%) in IQ was not related to either choice RT or delayed response performance, and may represent higher order cognitive processes.
Resumo:
This paper examines the psychometric quality of the Early/Late Preferences Scale (PS) relative to that of the Composite Morningness Scale (CS). Questionnaires were completed by 670 undergraduate students aged 16-37 years (mean 22.5), of whom 64% were female. Both scales displayed satisfactory inter-item correlations and similar total mean scores to those reported previously, although the CS had higher variability. Principal axis factor analysis produced single-factor solutions for both scales, although loadings for Items 7 and 9 on the PS were low. Internal consistencies for both scales were good (PS=0.86, CS=0.90) with only a small improvement achieved by deleting Items 7 and 9 from the PS. Test-retest reliability over 11 weeks was good for both scales (PS=0.92, CS=0.89). Differences between morning, evening and intermediate groups in self-rated alertness at different times of day, and significant correlations with other indices of morning-evening orientation, provided evidence of validity for both scales. These results indicate that PS is psychometrically comparable with CS. In view of its simpler format and lower cultural specificity, PS may be considered a preferable measure for most applications.
Resumo:
Developed, piloted, and examined the psychometric properties of the Child and Adolescent Social and Adaptive Functioning Scale (CASAFS), a self-report measure designed to examine the social functioning of young people in the areas of school performance, peer relationships, family relationships, and home duties/self-care. The findings of confirmatory and exploratory factor analysis support a 4-factor solution consistent with the hypothesized domains. Fit indexes suggested that the 4-correlated factor model represented a satisfactory solution for the data, with the covariation between factors being satisfactorily explained by a single, higher order factor reflecting social and adaptive functioning in general. The internal consistency and 12-month test-retest reliability of the total scale was acceptable. A significant, negative correlation was found between the CASAFS and a measure of depressive symptoms, showing that high levels of social functioning are associated with low levels of depression. Significant differences in CASAFS total and subscale scores were found between clinically depressed adolescents and a matched sample of nonclinical controls. Adolescents who reported elevated but subclinical levels of depression also reported lower levels of social functioning in comparison to nonclinical controls.
Resumo:
INTRODUCTION: Among psychiatric disorders schizophrenia is often said to be the condition with the most disputed definition.The Bleulerian and Schneiderian approaches have given rise to diagnostic formulations that have varied with time and place. Controversies over the concept of schizophrenia were examined within European/North American settings in the early 1970s but little has since been reported on the views of psychiatrists in developing countries. In Brazil both concepts are referred to in the literature. A scale was developed to measure adherence to Bleulerian and Schneiderian concepts among psychiatrists working in S. Paulo. METHODOLOGY: A self-reported questionnaire comprising seventeen visual analogue-scale statements related to Bleulerian and Schneiderian definitions of Shizophrenia, plus sociodemographic and training characteristics, was distributed to a non-randomised sample of 150 psychiatrists. The two sub-scales were assessed by psychometric methods for internal consistency, sub-scale structure and test-retest reliability. Items selected according to internal consistency were examined by a two-factor model exploratory factor analysis. Intraclass correlation coefficients described the stability of the scale. RESULTS: Replies were received from 117 psychiatrists (mean age 36 (SD 7.9)), 74% of whom were made and 26% female. The Schneiderian scale showed better overall internal consistency than the Bleulerian scale. Intra-class correlation coefficients for test-retest comparisons were between 0.5 and 0.7 for Schneiderian items and 0.2 and 0.7 for Bleulerian items. There was no negative association between Bleulerian and Schneiderian scale scores, suggesting that respondents may hold both concepts. Place of training was significantly associated with the respondent's opinion; disagreement with a Bleulerian standpoint predominated for those trained at the University of S. Paulo. CONCLUSIONS: The less satisfactory reliability for the Bleulerian sub-scale limits confidence in the whole scale but on the other hand this questionnaire contributes to the understanding of the controversy over Bleulerian and Schneiderian models for conceptualisation of schizophrenia, the former requiring more inference and therefore being prone to unreliability.
Resumo:
OBJECTIVE: To evaluate the reliability and validity of the Portuguese version of the Women's Health Questionnaire. METHODS: In order to evaluate the Women's Health Questionnaire (WHQ), an analytical cross-sectional study was carried out at the women's menopause outpatient clinic of a university hospital in São Paulo, Brazil. There were studied 87 women in perimenopause or menopause, defined as experiencing at least one year's absence of menstrual flow. The following variables were collected: demographic data, clinical variables (Kupperman index and correlate numeric scale) and quality of life indexes (SF-36 and utility). RESULTS: The WHQ proved to be a questionnaire easily translated into Portuguese and well-adjusted to Brazilian women. The internal consistency of the overall WHQ was excellent (Cronbach alpha =0.83; 95% CI: 0.71-0.91). Test-retest reliability was also excellent (intraclass correlation coefficient [ICC]=0.92; 95% IC: 0.86-0.96) and had good absolute agreement (0.84; 95% CI: 0.71-0.92). A satisfactory clinical validity was observed. The construct validity was corroborated by clear associations with others scales. A good index of responsiveness after the intervention was reached. CONCLUSIONS: The Portuguese version of the WHQ is of easy and fast administration and understanding. Its measuring properties were related, allowing its use in the evaluation of Brazilian climacteric women's quality of life for various purposes.
Resumo:
OBJECTIVE: The increasing proportion of older adults in the general population and the specific characteristics of this age group show the need for the development of specific instruments to measure quality of life in older adults. The study aimed at describing the development and validation of the Portuguese version of the World Health Organization Quality of Life for Older Persons (WHOQOL-OLD) module. METHODS: The WHOQOL-OLD instrument was administered in a sample of 424 older adults in the city of Porto Alegre, Southern Brazil, in 2005. The questionnaire comprises 24 items divided into six facets: sensory abilities; autonomy; past, present and future activities; social participation; death and dying; and intimacy. Besides the WHOQOL-OLD module, the WHOQOL-BREF, BDI and BHS instruments were also applied. The instrument's internal consistency was assessed using Cronbach's alpha coefficient. RESULTS: The instrument showed adequate internal consistency (Cronbach's coefficients ranging from 0.71 to 0.88), discriminant validity (p<0.01), concurrent validity (correlation coefficients ranging from -0.61 to -0.50) and test-retest reliability (correlation coefficients ranging from 0.58 to 0.82). Findings concerning criterion validity need further studies. CONCLUSIONS: The WHOQOL-Old module is a useful alternative with good psychometric performance in the investigation of quality of life in older adults.
Resumo:
OBJECTIVE: To develop an instrument to assess discrimination effects on health outcomes and behaviors, capable of distinguishing harmful differential treatment effects from their interpretation as discriminatory events. METHODS: Successive versions of an instrument were developed based on a systematic review of instruments assessing racial discrimination, focus groups and review by a panel comprising seven experts. The instrument was refined using cognitive interviews and pilot-testing. The final version of the instrument was administered to 424 undergraduate college students in the city of Rio de Janeiro, Southeastern Brazil, in 2010. Structural dimensionality, two types of reliability and construct validity were analyzed. RESULTS: Exploratory factor analysis corroborated the hypothesis of the instrument's unidimensionality, and seven experts verified its face and content validity. The internal consistency was 0.8, and test-retest reliability was higher than 0.5 for 14 out of 18 items. The overall score was higher among socially disadvantaged individuals and correlated with adverse health behaviors/conditions, particularly when differential treatments were attributed to discrimination. CONCLUSIONS: These findings indicate the validity and reliability of the instrument developed. The proposed instrument enables the investigation of novel aspects of the relationship between discrimination and health.
Resumo:
Mestrado em Fisioterapia
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
OBJECTIVE To analyze evidence of the validity and reliability of a Brazilian Portuguese version of the Quality of Care Scale from the perspective of people with physical and intellectual disabilities.METHODS There were 162 people with physical disabilities and 156 with intellectual disabilities from Porto Alegre and metropolitan region, who participated in the study in 2008. Classical psychometrics was used to independently analyze the two samples. Hypotheses for evidence of criterion validity (concurrent type) were tested with the Mann-Whitney test for non-normal distributions. Principal components analysis was used to explore factorial models. Evidence of reliability was calculated with Cronbach alpha for the scales and subscales. Test-retest reliability was analyzed for individuals with intellectual disabilities through intra-class correlation coefficient and the Willcoxon test.RESULTS The principal components in the group with physical disabilities replicated the original model presented as a solution to the international project data. Evidence of discriminant validity and test-retest reliability was found.CONCLUSIONS The transcultural factor model found within the international sample project seems appropriate for the samples investigated in this study, especially the physical disabilities group. Depression, pain, satisfaction with life and disability may play a mediating role in the evaluation of quality of care. Additional research is needed to add to evidence of the validity of the instruments.
Resumo:
ABSTRACTOBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context.METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants.RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods.CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.
Resumo:
RESUMO: Um dos principais resultados das intervenções de Fisioterapia dirigidas a utentes com Dor Lombar Crónica (DLC) é reduzir a incapacidade funcional. A Quebec Back Pain Disability Scale (QBPDS) é um instrumento amplamente aceite a nível internacional na medição do nível de incapacidade funcional reportada pelos indivíduos com DLC. O objetivo deste estudo é dar um contributo para a adaptação cultural da versão portuguesa da QBPDS (QBPDS-VP) e investigar o poder de resposta e interpretabilidade da escala. Metodologia: Realizou-se um estudo metodológico, multicentro, baseado num coorte prospetivo de 132 utentes com DLC. Os utentes foram recrutados a partir da lista de espera de 16 serviços de Medicina Física e de Reabilitação/Fisioterapia de várias áreas geográficas de Portugal. A QBPDS- VP foi administrada 3 vezes, em 3 momentos de recolha de dados distintos: T0 - momento inicial (utentes em lista de espera); T1 - 1 semana de intervalo (início dos tratamentos de Fisioterapia); e T2 - 6 semanas de intervalo (pós-intervenção de Fisioterapia). Os dados recolhidos em T0 foram utilizados para a análise fatorial e para o estudo da consistência interna (n=132); os dados da amostra emparelhada de T0 e T1 (n=132) para a fiabilidade teste-reteste; e os dados da amostra emparelhada de T0 e T2 (n=120) para a análise do poder de resposta e interpretabilidade. A âncora externa utilizada foi a perceção global de mudança, neste caso a PGIC- VP, que foi respondida em T1 e T2. O nível de significância para o qual os valores se consideraram satisfatórios foi de p≤ 0,05. O tratamento dos dados foi realizado no software IBM SPSS Statistics (versão 20). Resultados: A QBPDS- VP é uma escala unidimensional, que revela uma excelente consistência interna (α de Cronbach= 0,95) e uma fiabilidade teste-reteste satisfatória (CCI= 0,696; IC 95%: 0,581–0,783). Esta escala demonstrou um poder de resposta moderado, quando aplicada em utentes com DLC ( = 0,426 e AAC= 0,741; IC 95%: 0,645 – 0,837). A Diferença Mínima Detetável (DMD) estimada foi de 19 pontos e as estimativas da Diferença Mínima Clinicamente Importante (DMCI) variaram entre 7 (pelo método curva ROC) e 8 pontos (pelo método “diferença média de pontuação”). A estimativa pela curva ROC deriva do ponto ótimo de corte de 6,5 pontos, com Área Abaixo da Curva (AAC)= 0,741, sensibilidade de 72%, e especificidade de 71%. Uma análise complementar da curva ROC baseada nas diferenças de pontuações da QBPDS, expressa em percentagem, revelou um ponto ótimo de corte de - 24% (AAC= 0,737, sensibilidade de 71%, e especificidade de 71%). Para pontuações iniciais da QBPDS- VP mais altas (≥34 pontos), foi encontrado um ponto ótimo de corte de 10,5 pontos (AAC= 0,738, sensibilidade de 73%, e especificidade de 67%). Conclusão: A QBPDS-VP demonstrou bons níveis de fiabilidade e poder de resposta, recomendando-se o seu uso na medição e avaliação da incapacidade funcional de utentes com DLC. A DMD estimada, de 19 pontos, determinou uma amplitude válida da QBPDS-VP de 19 a 81 pontos. Este estudo propõe estimativas de DMCI da QBPDS- VP numa aplicação específica da escala (em utentes com DLC que são referidos para a intervenção de Fisioterapia). A pontuação inicial da QBPDS- VP deve ser considerada na interpretação de mudanças de pontuação, após a intervenção de Fisioterapia.------------ ABSTRACT: One of the main results of physiotherapy interventions for patients with Chronic Low Back Pain (CLBP) is decrease the functional disability. The Quebec Back Pain Disability Scale (QBPDS) is an instrument widely accepted internationally, in measuring the level of disability reported by individuals with CLBP. The purpose of this study is to contribute to the cultural adaptation of the Portuguese version of QBPDS (QBPDS - PV) and investigate the Responsiveness and Interpretability of QBPDS-PV. Methodology: This was a methodological and multicenter study, based on a sample of 132 subjects with CLBP. The patients were recruited from the waiting lists of 16 medicine rehabilitation service, in many Portugal districts. The Quebec Back Pain Disability Scale was administered in three different moments: T0 – baseline (patients in the waiting list); T1- one week after T0 (the beginning of treatment); and T2 – six weeks after T1 (the posttreatment). The data collected at T0 were used for factor analysis and to study the internal consistency (n = 132); paired sample data of T0 and T1 (n=132) were used for test-retest reliability, and sample data paired for T0 and T2 (n=120) used for responsiveness and interpretability analysis. The external anchor was the global perception of change, measured by the Portuguese version of Patient’s Global Impression of Change (PGIC) Scale. The minimal level of significance established was p ≤ 0,05. Data analysis was performed using the IBM SPSS Statistics software (version 20). Results: The QBPDS-PV is a unidimensional scale, demonstrates an excellent internal consistency (Cronbach's α=0.95) and satisfactory test-retest reliability (ICC= 0.696, 95% CI: 0.581–0.783). The scale revealed moderate responsiveness when applied to patients with CLBP ( = 0.426 and AUC= 0.741, 95% CI: 0.645 - 0.837). The Smallest Detectable Change (SDC) was 19 points, whereas the Minimal Clinically Important Change (MCIC) ranged between 7 (ROC curve method) and 8 points (by the "mean difference score"). The estimate was derived from the ROC curve by an optimal cutoff point of 6.5 points, with Area Under the Curve (AUC)= 0.741, sensitivity 72%, and specificity of 71%. A complementary analysis of the ROC curve based on differences in QBPDS scores from baseline, expressed in percentage, revealed an optimal cutoff point of -24% (AUC= 0.737, sensitivity of 71%, and specificity of 71%). For the highest initial scores of QBPDS-PV (≥ 34 points) was found an optimal cutoff of 10.5 points (AUC= 0.738, sensitivity of 73%, and specificity 67%). Conclusion: The QBPDS-PV demonstrated good levels of reliability and responsiveness, being recommended its use in the measurement and evaluation of disability of patients with CLBP. The SDC of 19 points determined the QBPDS‟ scale width of 19 to 81. This study proposes MCIC values for QBPDS –PV for this specific setting (in CLBP patients who are referred for physiotherapy intervention). The QBPDS –PV baseline score have to be taken into account while interpreting the score change after physiotherapy intervention.