825 resultados para subacute rehabilitation
Resumo:
AIM: To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen crosslinking (CXL) after previous intrastromal corneal ring segment (ISCR) implantation for keratoconus. METHODS: An experimental clinical study on twenty-one eyes of 19 patients aged, 27.1±6.6 years (range: 19 – 43 years), with low to moderate keratoconus who were selected to undergo customized TG-PRK immediately followed by same-day CXL, 9 months after ISCR implantation in a university ophthalmology clinic. Refraction, uncorrected (UDVA) and corrected distance visual acuities (CDVA), keratometry (K) values, central corneal thickness (CCT) and coma were assessed 3 months after TG/PRK and CXL. RESULTS: After TG-PRK/CXL: the mean UDVA (logMAR) improved significantly from 0.66±0.41 to 0.20±0.25 (P<0.05); K flat value decreased from: 48.44±3.66 D to 43.71±1.95 D; K steep value decreased from 45.61±2.40 D to 41.56±2.05D; K average also decreased from 42.42±2.07 D to 47.00±2.66 D (P<0.05 for all). The mean sphere and cylinder decreased significantly post-surgery from, -3.10±2.99 D to -0.11±0.93 D and from, -3.68±1.53 to -1.11±0.75D respectively, while the CDVA, CCT and coma showed no significant changes. Compared to post-ISCR, significant reductions (P ˂ 0.05 or all) in all K-values, sphere and cylinder were observed after TG-PRK/CXL. CONCLUSION: Same-day combined topography-guided PRK and corneal crosslinking following placement of ICRS is a safe and potentially effective option in treating low-moderate keratoconus. It significantly improved all visual acuity, reduced keratometry, sphere and astigmatism, but caused no change in central corneal thickness and coma.
Resumo:
This research project evaluated the biomechanical and functional outcomes of patients following total knee replacement measured at 6 and 12 months following surgery. Using more objective measures, patients were examined to determine changes in biomechanical and neuromuscular function during performance of activities of daily living such as walking, stair climbing and turning. Adaptations in joint positioning and performance were identified and progressive improvements were made in some areas of locomotor function. The findings of the study provided important objective information to contribute to the design and evaluation of prostheses, new surgical and rehabilitation procedures and improved recovery of patients.
Resumo:
Exploring the ethical issues present in professional practice within the field of sport, exercise and performance psychology, this case study outlines challenges that may be encountered, ways to address issues should they arise, and the overall ethical considerations of supporting injury rehabilitation within a dance training context.
Resumo:
This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program
Resumo:
This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program
Resumo:
This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program
Resumo:
This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program
Resumo:
This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program.
Resumo:
Access to the right information at the right time is a challenge facing health professionals across the globe. HEART Online (www.heartonline.org.au) is a website designed to support the delivery of evidence based care for the prevention and rehabilitation of heart disease. It was developed by the Queensland Government and the National Heart Foundation of Australia and launched May 2013.
Resumo:
This report examines the effectiveness of national and international programs that treat and rehabilitate drivers with alcohol dependence and the criteria used to approve the removal of interlocks. The project recommends a stepped care model which requires all participants to attend education and screening and then requires participants who fail to change their behaviour to attend increasingly intensive rehabilitation programs. Failure to complete an interlock program could result in participants having their licence revoked. This project was designed to inform action 36(d) of the National Road Safety Strategy 2011-2020: Investigate the option of requiring demonstrated rehabilitation from alcohol dependence before removal of interlock conditions.
Resumo:
Austroads called for responses to a tender to investigate options for rehabilitation in alcohol interlock programs. Following successful application by the Centre for Accident Research and Road Safety – Queensland (CARRS-Q), a program of work was developed. The project has four objectives: 1. Develop a matrix outlining existing policies in national and international jurisdictions with respect to treatment and rehabilitation programs and criteria for eligibility for interlock removal; 2. Critically review the available literature with a focus on evaluation outcomes regarding the effectiveness of treatment and rehabilitation programs; 3. Analyse and assess the strengths and weaknesses of the programs/approaches identified, and; 4. Outline options with an evidence base for consideration by licensing authorities.
Resumo:
Osseointegration has been introduced in the orthopaedic surgery in the 1990’s in Gothenburg (Sweden). To date, there are two frequently used commercially available human implants: the OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany) systems. The rehabilitation program with both systems include some form of static load bearing exercises. These latter involved following a load progression that is monitored by the bathroom scale, providing only the load applied on the vertical axis. The loading data could be analysed through different biomechanical variables. For instance, the load compliance, corresponding to the difference between the load recommended (LR) and the load actually applied on the implant, will be presented here.
Resumo:
The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].