250 resultados para spirometry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Chronic obstructive pulmonary disease (COPD) is a complex condition with pulmonary and extra-pulmonary manifestations. This study describes the heterogeneity of COPD in a large and well characterised and controlled COPD cohort (ECLIPSE). Methods We studied 2164 clinically stable COPD patients, 337 smokers with normal lung function and 245 never smokers. In these individuals, we measured clinical parameters, nutritional status, spirometry, exercise tolerance, and amount of emphysema by computed tomography. Results COPD patients were slightly older than controls and had more pack years of smoking than smokers with normal lung function. Co-morbidities were more prevalent in COPD patients than in controls, and occurred to the same extent irrespective of the GOLD stage. The severity of airflow limitation in COPD patients was poorly related to the degree of breathlessness, health status, presence of co-morbidity, exercise capacity and number of exacerbations reported in the year before the study. The distribution of these variables within each GOLD stage was wide. Even in subjects with severe airflow obstruction, a substantial proportion did not report symptoms, exacerbations or exercise limitation. The amount of emphysema increased with GOLD severity. The prevalence of bronchiectasis was low (4%) but also increased with GOLD stage. Some gender differences were also identified. Conclusions The clinical manifestations of COPD are highly variable and the degree of airflow limitation does not capture the heterogeneity of the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Quantitative analysis of chest radiographs of patients with and without chronic obstructive pulmonary disease (COPD) determining if the data obtained from such radiographic images could classify such individuals according to the presence or absence of disease. Materials and Methods For such a purpose, three groups of chest radiographic images were utilized, namely: group 1, including 25 individuals with COPD; group 2, including 27 individuals without COPD; and group 3 (utilized for the reclassification /validation of the analysis), including 15 individuals with COPD. The COPD classification was based on spirometry. The variables normalized by retrosternal height were the following: pulmonary width (LARGP); levels of right (ALBDIR) and left (ALBESQ) diaphragmatic eventration; costophrenic angle (ANGCF); and right (DISDIR) and left (DISESQ) intercostal distances. Results As the radiographic images of patients with and without COPD were compared, statistically significant differences were observed between the two groups on the variables related to the diaphragm. In the COPD reclassification the following variables presented the highest indices of correct classification: ANGCF (80%), ALBDIR (73.3%), ALBESQ (86.7%). Conclusion The radiographic assessment of the chest demonstrated that the variables related to the diaphragm allow a better differentiation between individuals with and without COPD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sixty-one cystic fibrosis patients admitted for check-up or antibiotic treatment were enrolled for genetic and clinical evaluation. Genetic analysis was performed on blood samples stored on neonatal screening cards using PCR techniques to determine the presence of DF508 mutations. Clinical evaluation included Shwachman and Chrispin-Norman scores, age at onset of symptoms and diagnosis, spirometry, awake and sleep pulse oximetry, hyponychial angle measurement and presence of chronic Pseudomonas aeruginosa colonization. Eighteen patients (29.5%) were homozygous for the DF508 mutation, 26 (42.6%) had one DF508 mutation and 17 (27.9%) were noncarriers, corresponding to a 50.8% prevalence of the mutation in the whole population. Analysis by the Kruskal-Wallis test for comparison of genetic status with continuous variables or by the chi-square test and logistic regression for dichotomous variables showed no significant differences between any two groups for a = 0.05. We conclude that genetic status in relation to the DF508 mutation is not associated with pulmonary status as evaluated by the above variables

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99mTc-DTPA is increased in SLE patients with active disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This prospective study analyzed the involvement of the autonomic nervous system in pulmonary and cardiac function by evaluating cardiovascular reflex and its correlation with pulmonary function abnormalities of type 2 diabetic patients. Diabetic patients (N = 17) and healthy subjects (N = 17) were evaluated by 1) pulmonary function tests including spirometry, He-dilution method, N2 washout test, and specific airway conductance (SGaw) determined by plethysmography before and after aerosol administration of atropine sulfate, and 2) autonomic cardiovascular activity by the passive tilting test and the magnitude of respiratory sinus arrhythmia (RSA). Basal heart rate was higher in the diabetic group (87.8 ± 11.2 bpm; mean ± SD) than in the control group (72.9 ± 7.8 bpm, P<0.05). The increase of heart rate at 5 s of tilting was 11.8 ± 6.5 bpm in diabetic patients and 17.6 ± 6.2 bpm in the control group (P<0.05). Systemic arterial pressure and RSA analysis did not reveal significant differences between groups. Diabetes intragroup analysis revealed two behaviors: 10 patients with close to normal findings and 7 with significant abnormalities in terms of RSA, with the latter subgroup presenting one or more abnormalities in other tests and clear evidence of cardiovascular autonomic dysfunction. End-expiratory flows were significantly lower in diabetic patients than in the control group (P<0.05). Pulmonary function tests before and after atropine administration demonstrated comparable responses by both groups. Type 2 diabetic patients have cardiac autonomic dysfunction that is not associated with bronchomotor tone alterations, probably reflecting a less severe impairment than that of type 1 diabetes mellitus. Yet, a reduction of end-expiratory flow was detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the aim of investigating the presence of latent inflammatory process in the lungs of patients with Crohn's disease, 15 patients with Crohn's disease were evaluated by spirometry, the methacholine challenge test, induced sputum, and skin tests for inhaled antigens. Serum IgE, erythrocyte sedimentation rate and hematocrit were also determined. The patients were compared with 20 healthy controls by the Mann-Whitney and Fisher exact tests. Their respiratory physical examination was normal. None had a personal or family history of clinical atopy. None had a previous history of pulmonary disease, smoking or toxic bronchopulmonary exposure. None had sinusitis, migraine, diabetes mellitus, or cardiac failure. Four (26.6%) of the patients with Crohn's disease had a positive methacholine challenge test whereas none of the 20 controls had a positive methacholine test (P = 0.026, Fisher exact test). Patients with Crohn's disease had a higher level of lymphocytes in induced sputum than controls (mean 14.59%, range 3.2-50 vs 5.46%, 0-26.92%, respectively; P = 0.011, Mann-Whitney test). Patients with Crohn's disease and a positive methacholine challenge test had an even higher percentage of lymphocytes in induced sputum compared with patients with Crohn's disease and a negative methacholine test (mean 24.88%, range 12.87-50 vs 10.48%, 3.2-21.69%; P = 0.047, Mann-Whitney test). The simultaneous findings of bronchopulmonary lymphocytosis and bronchial hyperresponsiveness in patients with Crohn's disease were not reported up to now. These results suggest that patients with Crohn's disease present a subclinical inflammatory process despite the absence of pulmonary symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne) and flow-oriented (Triflo II and Respirex) devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º). Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02) and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01) were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm). Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively). Abdominal motion was larger (P < 0.05) during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex). We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epidemiological and clinical evidence suggests that a judicious diet, regular physical activity and blood pressure (BP) monitoring must start in early childhood to minimize the impact of modifiable cardiovascular risk factors. This study was designed to evaluate BP and metabolic parameters of schoolchildren from Vitória, Espírito Santo State, Brazil, and correlate them with cardiovascular risk factors. The study was conducted on 380 students aged 10-14 years (177 boys, 203 girls) enrolled in public schools. Baseline measurements included body mass index, BP and heart rate. The students were submitted to exercise spirometry on a treadmill. VO2max was obtained from exercise testing to voluntary exhaustion. Fasting serum total cholesterol (TC), LDL-C, HDL-C, triglycerides (TG), and glucose were measured. Nine point nine percent of the boys and 11.7% of the girls were hypertensive or had pre-hypertensive levels. There was no significant correlation between VO2max and TC, LDL-C, or TG in prepubertal children, but a slight negative correlation was detected in post-pubertal boys for HDL-C and TG. In addition, children with hypertension (3.4%) or pre-hypertensive levels (6.6%) also had comorbidity for overweight and blood lipid abnormalities (14% for triglycerides, 44.7% for TC, 25.9% for LDL-C, 52% for low HDL-C). The present study shows for the first time high correlations between prehypertensive blood pressure levels and the cardiovascular risk factors high TC, high LDL-C, low HDL-C in schoolchildren. These are important for the formulation of public health policies and strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease (COPD) is a common disease in adults over 40 years of age and has a great social and economic impact. It remains little recognized and undertreated even in developed countries. However, there are no data about its diagnosis and treatment in Brazil. The objectives of the present study were to evaluate the proportion of COPD patients who had never been diagnosed and to determine if the COPD patients who had been identified were receiving appropriate treatment. The Latin American Project for the Investigation of Obstructive Lung Disease (PLATINO) was a randomized epidemiological study of adults over 40 years living in five metropolitan areas, including São Paulo. The studied sample was randomly selected from the population after a division of the metropolitan area of São Paulo in clusters according to social characteristics. All subjects answered a standardized questionnaire on respiratory symptoms, history of smoking, previous diagnosis of lung disease, and treatments. All subjects performed spirometry. The criterion for the diagnosis of COPD was defined by a post-bronchodilator FEV1/FVC ratio lower than 0.7. A total of 918 subjects were evaluated and 144 (15.8%) met the diagnostic criterion for COPD. However, 126 individuals (87.5%) had never been diagnosed. This undiagnosed group of COPD patients had a lower proportion of subjects with respiratory symptoms than the previously diagnosed patients (88.9 vs 54.8%) and showed better lung function with greater FEV1 (86.8 ± 20.8 vs 68.5 ± 23.6% predicted) and FVC (106.6 ± 22.4 vs 92.0 ± 24.1% predicted). Among the COPD patients, only 57.3% were advised to stop smoking and 30.6% received the influenza vaccine. In addition, 82.3% did not receive any pharmacological treatment. In conclusion, COPD is underdiagnosed and a large number of COPD patients are not treated appropriately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was to evaluate breathing pattern, thoracoabdominal motion and muscular activity during three breathing exercises: diaphragmatic breathing (DB), flow-oriented (Triflo II) incentive spirometry and volume-oriented (Voldyne) incentive spirometry. Seventeen healthy subjects (12 females, 5 males) aged 23 ± 5 years (mean ± SD) were studied. Calibrated respiratory inductive plethysmography was used to measure the following variables during rest (baseline) and breathing exercises: tidal volume (Vt), respiratory frequency (f), rib cage contribution to Vt (RC/Vt), inspiratory duty cycle (Ti/Ttot), and phase angle (PhAng). Sternocleidomastoid muscle activity was assessed by surface electromyography. Statistical analysis was performed by ANOVA and Tukey or Friedman and Wilcoxon tests, with the level of significance set at P < 0.05. Comparisons between baseline and breathing exercise periods showed a significant increase of Vt and PhAng during all exercises, a significant decrease of f during DB and Voldyne, a significant increase of Ti/Ttot during Voldyne, and no significant difference in RC/Vt. Comparisons among exercises revealed higher f and sternocleidomastoid activity during Triflo II (P < 0.05) with respect to DB and Voldyne, without a significant difference in Vt, Ti/Ttot, PhAng, or RC/Vt. Exercises changed the breathing pattern and increased PhAng, a variable of thoracoabdominal asynchrony, compared to baseline. The only difference between DB and Voldyne was a significant increase of Ti/Ttot compared to baseline. Triflo II was associated with higher f values and electromyographic activity of the sternocleidomastoid. In conclusion, DB and Voldyne showed similar results while Triflo II showed disadvantages compared to the other breathing exercises.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present cross-sectional, population-based study was designed to evaluate the performance of the FEV1/FEV6 ratio for the detection of airway-obstructed subjects compared to the FEV1/FVC <0.70 fixed ratio test, as well as the lower limit of normality (LLN) for 1000 subjects ³40 years of age in the metropolitan area of São Paulo, SP, Brazil. After the exclusion of 37 (3.7%) spirometries, a total of 963 pre-bronchodilator (BD) and 918 post-BD curves were constructed. The majority of the post-BD curves (93.1%) were of very good quality and achieved grade A (762 curves) or B (93 curves). The FEV1/FEV6 and FEV1/FVC ratios were highly correlated (r² = 0.92, P < 0.000). Two receiver operator characteristic curves were constructed in order to express the imbalance between the sensitivity and specificity of the FEV1/FEV6 ratio compared to two FEV1/FVC cut-off points for airway obstruction: equal to 70 (area under the curve = 0.98, P < 0.0001) and the LLN (area under the curve = 0.97, P < 0.0001), in the post-BD curves. According to an FEV1/FVC <0.70, the cut-off point for the FEV1/FEV6 ratio with the highest sum for sensitivity and specificity was 0.75. The FEV1/FEV6 ratio can be considered to be a good alternative to the FEV1/FVC ratio for the diagnosis of airway obstruction, both using a fixed cut-off point or below the LLN as reference. The FEV1/FEV6 ratio has the additional advantage of being an easier maneuver for the subjects and for the lung function technicians, providing a higher reproducibility than traditional spirometry maneuvers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few studies have evaluated the relationship between Airways Questionnaire 20 (AQ20), a measure of the quality of life, scores and physiological outcomes or with systemic markers of disease in patients with chronic obstructive pulmonary disease (COPD). The aim of the present study was to investigate the relationship of forced expiratory volume in 1 s (FEV1), body mass index, fat-free mass index, 6-min walk test (6MWT) results, dyspnea sensation and peripheral oxygen saturation (SpO2) with the quality of life of COPD patients. Ninety-nine patients with COPD (mean age: 64.2 ± 9.2 years; mean FEV1: 60.4 ± 25.2% of predicted) were evaluated using spirometry, body composition measurement and the 6MWT. The baseline dyspnea index (BDI) and the Modified Medical Research Council (MMRC) scale were used to quantify dyspnea. Quality of life was assessed using the AQ20 and the St. George's Respiratory Questionnaire (SGRQ). The Charlson index was used to determine comorbidity. The body mass index/airflow obstruction/dyspnea/exercise capacity (BODE) index was also calculated. AQ20 and SGRQ scores correlated significantly with FEV1, SpO2, 6MWT, MMRC and BDI values as did with BODE index. In the multivariate analyses, MMRC or BDI were identified as predictors of AQ20 and SGRQ scores (P < 0.001 in all cases). Thus, the relationship between AQ20 and disease severity is similar to that described for SGRQ. Therefore, the AQ20, a simple and brief instrument, can be very useful to evaluate the general impact of disease when the time allotted for measurement of the quality of life is limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disturbed sleep is common in chronic obstructive pulmonary disease (COPD). Conventional hypnotics worsen nocturnal hypoxemia and, in severe cases, can lead to respiratory failure. Exogenous melatonin has somnogenic properties in normal subjects and can improve sleep in several clinical conditions. This randomized, double-blind, placebo-controlled study was carried out to determine the effects of melatonin on sleep in COPD. Thirty consecutive patients with moderate to very severe COPD were initially recruited for the study. None of the participants had a history of disease exacerbation 4 weeks prior to the study, obstructive sleep apnea, mental disorders, current use of oral steroids, methylxanthines or hypnotic-sedative medication, nocturnal oxygen therapy, and shift work. Patients received 3 mg melatonin (N = 12) or placebo (N = 13), orally in a single dose, 1 h before bedtime for 21 consecutive days. Sleep quality was assessed by the Pittsburgh Sleep Quality Index (PSQI) and daytime sleepiness was measured by the Epworth Sleepiness Scale. Pulmonary function and functional exercise level were assessed by spirometry and the 6-min walk test, respectively. Twenty-five patients completed the study protocol and were included in the final analysis. Melatonin treatment significantly improved global PSQI scores (P = 0.012), particularly sleep latency (P = 0.008) and sleep duration (P = 0.046). No differences in daytime sleepiness, lung function and functional exercise level were observed. We conclude that melatonin can improve sleep in COPD. Further long-term studies involving larger number of patients are needed before melatonin can be safely recommended for the management of sleep disturbances in these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.