824 resultados para sleep tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a method for real-time detection and tracking of people in video captured by a depth camera. For each object to be assessed, an ordered sequence of values that represents the distances between its center of mass to the boundary points is calculated. The recognition is based on the analysis of the total distance value between the above sequence and some pre-defined human poses, after apply the Dynamic Time Warping. This similarity approach showed robust results in people detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 ± 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de Especialização: Ultrassonografia Cardiovascular

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a step-up micro-power converter for solar energy harvesting applications. The circuit uses a SC voltage tripler architecture, controlled by an MPPT circuit based on the Hill Climbing algorithm. This circuit was designed in a 0.13 mu m CMOS technology in order to work with an a-Si PV cell. The circuit has a local power supply voltage, created using a scaled down SC voltage tripler, controlled by the same MPPT circuit, to make the circuit robust to load and illumination variations. The SC circuits use a combination of PMOS and NMOS transistors to reduce the occupied area. A charge re-use scheme is used to compensate the large parasitic capacitors associated to the MOS transistors. The simulation results show that the circuit can deliver a power of 1266 mu W to the load using 1712 mu W of power from the PV cell, corresponding to an efficiency as high as 73.91%. The simulations also show that the circuit is capable of starting up with only 19% of the maximum illumination level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To explore whether parents' engagement in shift work affects the sleep habits of their adolescent children who attend school in two shifts. METHODS: The data were drawn from an extensive survey of sleep and daytime functioning of adolescents attending school one week in the morning and the other in the afternoon. The participants were 1,386 elementary and high school students (11-18 years old) whose parents were both employed. The data were analyzed using MANOVA, with parents' work schedule, adolescents' gender and type of school as between-subject factors. RESULTS: Parents' working schedule significantly affected the sleep patterns of high school adolescents. When attending school in the morning, adolescents whose parents were both day workers woke up somewhat later than adolescents with one shiftworking parent. In addition, they slept longer than adolescents whose parents were both shift workers. On weekends, adolescents whose parents both worked during the day went to bed earlier than adolescents whose parents were both shiftworkers. They also had smaller bedtime delay on weekends with respect to both morning and afternoon shifts than adolescents for whom one or both parents worked shifts. A significant interaction between parents' working schedule, adolescents' gender and type of school was found for sleep extension on weekends after afternoon shift school. CONCLUSIONS: Parental involvement in shift work has negative effects on the sleep of high school adolescents. It contributes to earlier wake-up time and shorter sleep in a week when adolescents attend school in the morning, as well as to greater bedtime irregularity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shopping centers present a rich and heterogeneous environment, where IT systems can be implemented in order to support the needs of its actors. However, due to the environment complexity, several feasibility issues emerge when designing both the logical and physical architecture of such systems. Additionally, the system must be able to cope with the individual needs of each actor, and provide services that are easily adopted by them, taking into account several sociological and economical aspects. In this sense, we present an overview of current support systems for shopping center environments. From this overview, a high-level model of the domain (involving actors and services) is described along with challenges and possible features in the context of current Semantic Web, mobile device and sensor technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether reported morbidity and complaints of lack of time and sleep are associated with the burden of professional work and housework among nurses. METHODS: A cross-sectional exploratory study was carried out among female nurses and nurse assistants (N=206) of a public hospital in Rio de Janeiro, Brazil. Data were collected by means of a questionnaire. The prevalence ratio and 95% confidence intervals were estimated. RESULTS: Mean duration of professional work and housework time was 40.4 and 31.6 hours/week, respectively. Long professional working time (over 44 hours/week) were associated with mild emotional disorders (PR=1.37; 95% CI: 1.05-1.80), complaints of lack of time for resting/leisure (PR=1.61; 95% CI: 1.31-1.97), housework (PR=1.48; 95% CI: 1.12-1.97), and childcare (PR=1.99; 95% CI: 1.51-2.63). Long housework time (over 28 hours/week) was associated with lower prevalence of lack of time for childcare (PR=0.62; 95% CI: 0.46-0.84). High housework load was associated with lack of personal time and complaints of varicose veins (PR=1.31; 95% CI: 1.14-1.50 and PR=1.31; 95% CI: 1.08-1.58, respectively). Complaints of varicose veins were also frequent among female nurses with a total work load above 84 hours (PR=1.30; 95% CI: 1.05-1.61), though this group has shown a lower prevalence of arterial hypertension and recurrent headaches (PR=0.35; 95% CI: 0.15-0.83 and PR=0.53; 95% CI: 0.32-0.89, respectively). CONCLUSIONS: Results suggest that both professional and home environments are relevant in the evaluation of work overload on nurses' health and their family and social life. It is stressed the need for instruments for analyzing total workload among female populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between regular physical activity in adolescence and leisure-time physical activity in adulthood, with emphasis on gender differences. METHODS: A population-based cross-sectional study was carried out in Pelotas, Southern Brazil, in 2003. A representative sample of households was selected in multiple stages and subjects aged 20-59 years were interviewed. Leisure-time physical activity was evaluated using the International Physical Activity Questionnaire. Data on adolescent physical activity were based on subjects' recall. RESULTS: Of 2,577 subjects interviewed, 27.5% were classified as adequately active, and 54.9% reported regular physical activity in adolescence. Subjects who engaged in regular physical activity during adolescence were more likely to be adequately active in adulthood (adjusted prevalence ratio 1.42; 95% CI: 1.23; 1.65). This effect was stronger in women (adjusted prevalence ratio: 1.51; 95% CI: 1.22; 1.86) than men (adjusted prevalence ratio: 1.35; 95% CI: 1.10; 1.67). CONCLUSIONS: Promoting physical activity in school age may be a successful intervention against the epidemic of adult inactivity. Although women were less likely to report regular physical activity in adolescence, the effect of this experience on adult behavior was stronger than in men.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os serviços baseados em localização vieram dar um novo alento à criatividade dos programadores de aplicações móveis. A vulgarização de dispositivos com capacidades de localização integradas deu origem ao desenvolvimento de aplicações que gerem e apresentam informação baseada na posição do utilizador. Desde então, o mercado móvel tem assistido ao aparecimento de novas categorias de aplicações que tiram proveito desta capacidade. Entre elas, destaca-se a monitorização remota de dispositivos, que tem vindo a assumir uma importância crescente, tanto no sector particular como no sector empresarial. Esta dissertação começa por apresentar o estado da arte sobre os diferentes sistemas de posicionamento, categorizados pela sua eficácia em ambientes internos ou externos, assim como diferentes protocolos de comunicação em tempo quase-real. É também feita uma análise ao estado actual do mercado móvel. Actualmente o mercado possui diferentes plataformas móveis com características únicas que as fazem rivalizar entre si, com vista a expandirem a sua quota de mercado. É por isso elaborado um breve estudo sobre os sistemas operativos móveis mais relevantes da actualidade. É igualmente feita uma abordagem mais profunda à arquitectura da plataforma móvel da Apple - o iOS – que serviu de base ao desenvolvimento de uma solução optimizada para localização e monitorização de dispositivos móveis. A monitorização implica uma utilização intensiva de recursos energéticos e de largura de banda que os dispositivos móveis da actualidade não estão aptos a suportar. Dado o grande consumo energético do GPS face à precária autonomia destes dispositivos, é apresentado um estudo em que se expõem soluções que permitem gerir de forma optimizada a utilização do GPS. O elevado custo dos planos de dados facultados pelas operadoras móveis é também considerado, pelo que são exploradas soluções que visam minimizar a utilização de largura de banda. Deste trabalho, nasce a aplicação EyeGotcha, que para além de permitir localizar outros utilizadores de dispositivos móveis de forma optimizada, permite também monitorizar as suas acções baseando-se num conjunto de regras pré-definidas. Estas acções são reportadas às entidades monitoras, de modo automatizado e sob a forma de alertas. Visionando-se a comercialização da aplicação, é portanto apresentado um modelo de negócio que permite obter receitas capazes de cobrirem os custos de manutenção de serviços, aos quais o funcionamento da aplicação móvel está subjugado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O VVI-Speckle Tracking é um método visual e quantitativo de avaliação dos parâmetros de deformação miocárdica utilizando a imagem bidimensional. Tem com principal vantagem em relação a outras metodologias a sua facilidade de execução. O SGL apresenta-se como o parâmetro de deformação miocárdica que mais precocemente deteta a alteração da função contrátil. Objectivo do estudo: determinar os valores do Strain Global Longitudinal (SGL), numa população de indivíduos normais utilizando a mais recente versão desta tecnologia e compará-los com outos valores já publicados, assim como a sua eventual variação com alguns parâmetros demográficos, como seja o género, idade e IMC.