992 resultados para size accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses. © 2004 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A newly released commercial autorefractor, the Shin-Nippon SRW-5000 (Japan), has been found to be valid compared to subjective refraction and repeatable over a wide prescription range. Its binocular open field-of-view allows the accommodative state to be monitored while a natural environment is viewed. In conventional static mode, the device can take up to 45 readings in 1min using digital image analysis of the reflected retinal image of a measurement ring. Continuous on-line analysis of the ring provides high (up to 60Hz) temporal resolution of the refractive state to an accuracy of <0.001D. Pupil size can also be analysed to a resolution of <0.001mm. The measurement of accommodation and pupil size was relatively unaffected by eccentricity of viewing up to ±10° and instrument focusing inaccuracies of ±5mm. The resolution properties of the analysis are shown to be ideal for measurement of dynamic accommodation and pupil responses. Copyright © 2001 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implementation of a Monte Carlo simulation for the solution of population balance equations (PBEs) requires choice of initial sample number (N0), number of replicates (M), and number of bins for probability distribution reconstruction (n). It is found that Squared Hellinger Distance, H2, is a useful measurement of the accuracy of Monte Carlo (MC) simulation, and can be related directly to N0, M, and n. Asymptotic approximations of H2 are deduced and tested for both one-dimensional (1-D) and 2-D PBEs with coalescence. The central processing unit (CPU) cost, C, is found in a power-law relationship, C= aMNb0, with the CPU cost index, b, indicating the weighting of N0 in the total CPU cost. n must be chosen to balance accuracy and resolution. For fixed n, M × N0 determines the accuracy of MC prediction; if b > 1, then the optimal solution strategy uses multiple replications and small sample size. Conversely, if 0 < b < 1, one replicate and a large initial sample size is preferred. © 2015 American Institute of Chemical Engineers AIChE J, 61: 2394–2402, 2015

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Correct specification of the simple location quotients in regionalizing the national direct requirements table is essential to the accuracy of regional input-output multipliers. The purpose of this research is to examine the relative accuracy of these multipliers when earnings, employment, number of establishments, and payroll data specify the simple location quotients.^ For each specification type, I derive a column of total output multipliers and a column of total income multipliers. These multipliers are based on the 1987 benchmark input-output accounts of the U.S. economy and 1988-1992 state of Florida data.^ Error sign tests, and Standardized Mean Absolute Deviation (SMAD) statistics indicate that the output multiplier estimates overestimate the output multipliers published by the Department of Commerce-Bureau of Economic Analysis (BEA) for the state of Florida. In contrast, the income multiplier estimates underestimate the BEA's income multipliers. For a given multiplier type, the Spearman-rank correlation analysis shows that the multiplier estimates and the BEA multipliers have statistically different rank ordering of row elements. The above tests also find no significant different differences, both in size and ranking distributions, among the vectors of multiplier estimates. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Correct specification of the simple location quotients in regionalizing the national direct requirements table is essential to the accuracy of regional input-output multipliers. The purpose of this research is to examine the relative accuracy of these multipliers when earnings, employment, number of establishments, and payroll data specify the simple location quotients. For each specification type, I derive a column of total output multipliers and a column of total income multipliers. These multipliers are based on the 1987 benchmark input-output accounts of the U.S. economy and 1988-1992 state of Florida data. Error sign tests, and Standardized Mean Absolute Deviation (SMAD) statistics indicate that the output multiplier estimates overestimate the output multipliers published by the Department of Commerce-Bureau of Economic Analysis (BEA) for the state of Florida. In contrast, the income multiplier estimates underestimate the BEA's income multipliers. For a given multiplier type, the Spearman-rank correlation analysis shows that the multiplier estimates and the BEA multipliers have statistically different rank ordering of row elements. The above tests also find no significant different differences, both in size and ranking distributions, among the vectors of multiplier estimates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Larger lineups could protect innocent suspects from being misidentified; however, they can also decrease correct identifications. Bertrand (2006) investigated whether the decrease in correct identifications could be prevented by adding more cues, in the form of additional views of lineup members’ faces, to the lineup. Adding these cues was successful to an extent. The current series of studies attempted to replicate Bertrand’s (2006) findings while addressing some methodological issues—namely, the inconsistency in image size as lineup size increased. First, I investigated whether image size could affect face recognition (Chapter 2) and found it could, but that it also affected previously-seen (“old”) versus previously-unseen (“new”) faces differently. Specifically, smaller image sizes at exposure lowered accuracy for old faces, while these same image sizes at recognition lowered accuracy for new faces. Although these results indicate that target recognition would be unaffected by image size at recognition (i.e., during a lineup), lineups are also comprised of previously-unseen faces, in the form of fillers and innocent suspects. Because image size could affect lineup decisions, as it could become more difficult to realize fillers are previously-unseen, I decided to replicate Bertrand (2006) while keeping image size constant in Chapters 3 (simultaneous lineups) and 4 (simultaneous-presentation, sequential decisions). In both Chapters, the integral findings were the same: correct identification rates decreased as lineup size increased from 6- to 24-person lineups, but adding cues had no effect. The inability to replicate Bertrand (2006) could mean that the original finding was due to chance, but alternate explanations also exist, such as the overall size of the array, the degree to which additional cues overlap, and the length of the target exposure. These alternate explanations, along with directions for future research, are discussed in the following Chapters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pop-up archival tags (PAT) provide summary and high-resolution time series data at predefined temporal intervals. The limited battery capabilities of PATs often restrict the transmission success and thus temporal coverage of both data products. While summary data are usually less affected by this problem, as a result of its lower size, it might be less informative. We here investigate the accuracy and feasibility of using temperature at depth summary data provided by PATs to describe encountered oceanographic conditions. Interpolated temperature at depth summary data was found to provide accurate estimates of three major thermal water column structure indicators: thermocline depth, stratification and ocean heat content. Such indicators are useful for the interpretation of the tagged animal's horizontal and vertical behaviour. The accuracy of these indicators was found to be particularly sensitive to the number of data points available in the first 100 m, which in turn depends on the vertical behaviour of the tagged animal. Based on our results, we recommend the use of temperature at depth summary data as opposed to temperature time series data for PAT studies; doing so during the tag programming will help to maximize the amount of transmitted time series data for other key data types such as light levels and depth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we construct a model for the simultaneous compaction by which clusters are restructured, and growth of clusters by pairwise coagulation. The model has the form of a multicomponent aggregation problem in which the components are cluster mass and cluster diameter. Following suitable approximations, exact explicit solutions are derived which may be useful for the verification of simulations of such systems. Numerical simulations are presented to illustrate typical behaviour and to show the accuracy of approximations made in deriving the model. The solutions are then simplified using asymptotic techniques to show the relevant timescales of the kinetic processes and elucidate the shape of the cluster distribution functions at large times.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Estimates of effective population size in the Holstein cattle breed have usually been low despite the large number of animals that constitute this breed. Effective population size is inversely related to the rates at which coancestry and inbreeding increase and these rates have been high as a consequence of intense and accurate selection. Traditionally, coancestry and inbreeding coefficients have been calculated from pedigree data. However, the development of genome-wide single nucleotide polymorphisms has increased the interest of calculating these coefficients from molecular data in order to improve their accuracy. In this study, genomic estimates of coancestry, inbreeding and effective population size were obtained in the Spanish Holstein population and then compared with pedigree-based estimates. A total of 11,135 animals genotyped with the Illumina BovineSNP50 BeadChip were available for the study. After applying filtering criteria, the final genomic dataset included 36,693 autosomal SNPs and 10,569 animals. Pedigree data from those genotyped animals included 31,203 animals. These individuals represented only the last five generations in order to homogenise the amount of pedigree information across animals. Genomic estimates of coancestry and inbreeding were obtained from identity by descent segments (coancestry) or runs of homozygosity (inbreeding). The results indicate that the percentage of variance of pedigree-based coancestry estimates explained by genomic coancestry estimates was higher than that for inbreeding. Estimates of effective population size obtained from genome-wide and pedigree information were consistent and ranged from about 66 to 79. These low values emphasize the need of controlling the rate of increase of coancestry and inbreeding in Holstein selection programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the efficacy and reproducibility of the cytologic diagnosis of salivary gland tumors (SGTs) using fine-needle aspiration cytology (FNAC). The study aimed to determine diagnostic accuracy, sensitivity, and specificity and to evaluate the extent of interobserver agreement. We retrospectively evaluated SGTs from the files of the Division of Pathology at the Clinics Hospital of São Paulo and Piracicaba Dental School between 2000 and 2006. We performed cytohistologic correlation in 182 SGTs. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 94%, 100%, 100%, 100%, and 99%, respectively. The interobserver cytologic reproducibility showed significant statistical concordance (P < .0001). FNAC is an effective tool for performing a reliable preoperative diagnosis in SGTs and shows high diagnostic accuracy and consistent interobserver reproducibility. Further FNAC studies analyzing large samples of malignant SGTs and reactive salivary lesions are needed to confirm their accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonium nitrate fuel oil (ANFO) is an explosive used in many civil applications. In Brazil, ANFO has unfortunately also been used in criminal attacks, mainly in automated teller machine (ATM) explosions. In this paper, we describe a detailed characterization of the ANFO composition and its two main constituents (diesel and a nitrate explosive) using high resolution and accuracy mass spectrometry performed on an FT-ICR-mass spectrometer with electrospray ionization (ESI(±)-FTMS) in both the positive and negative ion modes. Via ESI(-)-MS, an ion marker for ANFO was characterized. Using a direct and simple ambient desorption/ionization technique, i.e., easy ambient sonic-spray ionization mass spectrometry (EASI-MS), in a simpler, lower accuracy but robust single quadrupole mass spectrometer, the ANFO ion marker was directly detected from the surface of banknotes collected from ATM explosion theft.