959 resultados para routine


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Many patients may believe that HIV screening is included in routine preoperative work-ups. We examined what proportion of patients undergoing preoperative blood testing believed that they had been tested for HIV. METHODS: All patients hospitalized for elective orthopaedic surgery between January and December 2007 were contacted and asked to participate in a 15-min computer-assisted telephone interview (n = 1330). The primary outcome was to determine which preoperative tests patients believed had been performed from a choice of glucose, clotting, HIV serology and cholesterol, and what percentage of patients interpreted the lack of result communication as a normal or negative test. The proportion of patients agreeable to HIV screening prior to future surgery was also determined. RESULTS: A total of 991 patients (75%) completed the questionnaire. Three hundred and seventy-five of these 991 patients (38%) believed incorrectly that they had been tested for HIV preoperatively. Younger patients were significantly more likely to believe that an HIV test had been performed (mean age 46 vs. 50 years for those who did not believe that an HIV test had been performed; P < 0.0001). Of the patients who believed that a test had been performed but received no result, 96% interpreted lack of a result as a negative HIV test. Over 80% of patients surveyed stated that they would agree to routine HIV screening prior to future surgery. A higher acceptance rate was associated with younger age (mean age 47 years for those who would agree vs. 56 years for those who would not; P < 0.0001) and male sex ( P < 0.009). CONCLUSIONS: Many patients believe that a preoperative blood test routinely screens for HIV. The incorrect assumption that a lack of result communication indicates a negative test may contribute to delays in HIV diagnoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Only few countries have cohorts enabling specific and up-to-date cardiovascular disease (CVD) risk estimation. Individual risk assessment based on study samples that differ too much from the target population could jeopardize the benefit of risk charts in general practice. Our aim was to provide up-to-date and valid CVD risk estimation for a Swiss population using a novel record linkage approach. METHODS: Anonymous record linkage was used to follow-up (for mortality, until 2008) 9,853 men and women aged 25-74 years who participated in the Swiss MONICA (MONItoring of trends and determinants in CVD) study of 1983-92. The linkage success was 97.8%, loss to follow-up 1990-2000 was 4.7%. Based on the ESC SCORE methodology (Weibull regression), we used age, sex, blood pressure, smoking, and cholesterol to generate three models. We compared the 1) original SCORE model with a 2) recalibrated and a 3) new model using the Brier score (BS) and cross-validation. RESULTS: Based on the cross-validated BS, the new model (BS = 14107×10(-6)) was somewhat more appropriate for risk estimation than the original (BS = 14190×10(-6)) and the recalibrated (BS = 14172×10(-6)) model. Particularly at younger age, derived absolute risks were consistently lower than those from the original and the recalibrated model which was mainly due to a smaller impact of total cholesterol. CONCLUSION: Using record linkage of observational and routine data is an efficient procedure to obtain valid and up-to-date CVD risk estimates for a specific population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study aimed to explore the validity of an adaptation into French of the self-rated form of the Health of the Nation Outcome Scales for Children and Adolescents (F-HoNOSCA-SR) and to test its usefulness in a clinical routine use. One hundred and twenty nine patients, admitted into two inpatient units, were asked to participate in the study. One hundred and seven patients filled out the F-HoNOSCA-SR (for a subsample (N=17): at two occasions, one week apart) and the strengths and difficulties questionnaire (SDQ). In addition, the clinician rated the clinician-rated form of the HoNOSCA (HoNOSCA-CR, N=82). The reliability (assessed with split-half coefficient, item response theory (IRT) models and intraclass correlations (ICC) between the two occasions) revealed that the F-HoNSOCA-SR provides reliable measures. The concurrent validity assessed by correlating the F-HoNOSCA-SR and the SDQ revealed a good convergent validity of the instrument. The relationship analyses between the F-HoNOSCA-SR and the HoNOSCA-CR revealed weak but significant correlations. The comparison between the F-HoNOSCA-SR and the HoNOSCA-CR with paired sample t-tests revealed a higher score for the self-rated version. The F-HoNSOCA-SR was reported to provide reliable measures. In addition, it allows us to measure complementary information when used together with the HoNOSCA-CR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in vivo accessibility of the chick embryo makes it a favoured model system for experimental developmental biology. Although the range of available techniques now extends to miss-expression of genes through in ovo electroporation, it remains difficult to knock out individual gene expression. Recently, the possibility of silencing gene expression by RNAi in chick embryos has been reported. However, published studies show only discrete quantitative differences in the expression of the endogenous targeted genes and unclear morphological alterations. To elucidate whether the tools currently available are adequate to silence gene expression sufficiently to produce a clear and specific null-like mutant phenotype, we have performed several experiments with different molecules that trigger RNAi: dsRNA, siRNA, and shRNA produced from a plasmid coexpressing green fluorescent protein as an internal marker. Focussing on fgf8 expression in the developing isthmus, we show that no morphological defects are observed, and that fgf8 expression is neither silenced in embryos microinjected with dsRNA nor in embryos microinjected and electroporated with a pool of siRNAs. Moreover, fgf8 expression was not significantly silenced in most isthmic cells transformed with a plasmid producing engineered shRNAs to fgf8. We also show that siRNA molecules do not spread significantly from cell to cell as reported for invertebrates, suggesting the existence of molecular differences between different model systems that may explain the different responses to RNAi. Although our results are basically in agreement with previously reported studies, we suggest, in contrast to them, that with currently available tools and techniques the number of cells in which fgf8 gene expression is decreased, if any, is not sufficient to generate a detectable mutant phenotype, thus making RNAi useless as a routine method for functional gene analysis in chick embryos.