837 resultados para rooftop PV unit
Resumo:
Purpose – This study aims to evaluate the usefulness of a university unit Facebook page, which was established to support a first-year university justice unit. The study pays particular regard to the Facebook page's impact on students learning outcomes and communications amongst students and between students and teaching staff. Design/methodology/approach – All students enrolled in the unit were asked to complete an online survey, which sought to determine whether they used the unit Facebook page and if so, the nature and extent of their use. Findings – The study found that the unit Facebook page was useful in achieving most learning objectives for the unit. This included enhancing students' knowledge and understanding of unit content, as well as their ability to critically analyse unit materials. Students also indicated that they found the Facebook page better than the university's central learning management system across a range of areas. It was particularly useful for facilitating unit-related discussions. Research limitations/implications – The survey results reported in this paper are based on a relatively small sample of students (n=67) from a first-year university justice unit. Future studies should seek to garner evidence from broader and larger samples that transcend specific unit populations. However, the findings of this study do indicate further support for the use of Facebook as a supplementary tool in university education. Originality/value – This study focuses on two aspects of social networking technologies that have not been previously researched and thus contributes to the growing literature on the uses and benefits of Facebook in tertiary education.
Resumo:
Global awareness for cleaner and renewable energy is transforming the electricity sector at many levels. New technologies are being increasingly integrated into the electricity grid at high, medium and low voltage levels, new taxes on carbon emissions are being introduced and individuals can now produce electricity, mainly through rooftop photovoltaic (PV) systems. While leading to improvements, these changes also introduce challenges, and a question that often rises is ‘how can we manage this constantly evolving grid?’ The Queensland Government and Ergon Energy, one of the two Queensland distribution companies, have partnered with some Australian and German universities on a project to answer this question in a holistic manner. The project investigates the impact the integration of renewables and other new technologies has on the physical structure of the grid, and how this evolving system can be managed in a sustainable and economical manner. To aid understanding of what the future might bring, a software platform has been developed that integrates two modelling techniques: agent-based modelling (ABM) to capture the characteristics of the different system units accurately and dynamically, and particle swarm optimization (PSO) to find the most economical mix of network extension and integration of distributed generation over long periods of time. Using data from Ergon Energy, two types of networks (3 phase, and Single Wired Earth Return or SWER) have been modelled; three-phase networks are usually used in dense networks such as urban areas, while SWER networks are widely used in rural Queensland. Simulations can be performed on these networks to identify the required upgrades, following a three-step process: a) what is already in place and how it performs under current and future loads, b) what can be done to manage it and plan the future grid and c) how these upgrades/new installations will perform over time. The number of small-scale distributed generators, e.g. PV and battery, is now sufficient (and expected to increase) to impact the operation of the grid, which in turn needs to be considered by the distribution network manager when planning for upgrades and/or installations to stay within regulatory limits. Different scenarios can be simulated, with different levels of distributed generation, in-place as well as expected, so that a large number of options can be assessed (Step a). Once the location, sizing and timing of assets upgrade and/or installation are found using optimisation techniques (Step b), it is possible to assess the adequacy of their daily performance using agent-based modelling (Step c). One distinguishing feature of this software is that it is possible to analyse a whole area at once, while still having a tailored solution for each of the sub-areas. To illustrate this, using the impact of battery and PV can have on the two types of networks mentioned above, three design conditions can be identified (amongst others): · Urban conditions o Feeders that have a low take-up of solar generators, may benefit from adding solar panels o Feeders that need voltage support at specific times, may be assisted by installing batteries · Rural conditions - SWER network o Feeders that need voltage support as well as peak lopping may benefit from both battery and solar panel installations. This small example demonstrates that no single solution can be applied across all three areas, and there is a need to be selective in which one is applied to each branch of the network. This is currently the function of the engineer who can define various scenarios against a configuration, test them and iterate towards an appropriate solution. Future work will focus on increasing the level of automation in identifying areas where particular solutions are applicable.
Resumo:
This paper presents a distributed communication based active power curtailment (APC) control scheme for grid connected photovoltaic (PV) systems to address voltage rise. A simple distribution feeder model is presented and simulated using MATLAB. The resource sharing based control scheme proposed is shown to be effective at reducing voltage rise during times of peak generation and low load. Simulations also show the even distribution of APC using simple communications. Simulations demonstrate the versatility of the proposed control method under major communication failure conditions. Further research may lead to possible applications in coordinated electric vehicle (EV) charging.
Resumo:
Web 2.0 technologies are increasingly being used to support teaching in higher education courses. However, preliminary research has shown that students are using such technologies primarily for social purposes, rather than as a means of further engaging with academic content. This study examines a cohort of tertiary students' use of a Facebook page, which was created for a second year university policing unit at the Queensland University of Technology in Brisbane, Australia. Results from content analysis of the Facebook "wall" and a survey of student users and non-users showed that although students only demonstrated very little active engagement with academic content posted on the site (that is, they were reluctant to interact with unit materials in a way that would leave a digital trace), they reported that Facebook had increased their ability to engage with and critically analyse the unit content. In alignment with other research in this area, students also reported the usefulness of the Facebook page for increasing communication with their peers and with the teaching staff. This paper concludes by offering a number of best practice guidelines for the use of Facebook in tertiary education.
Intra-arterial waveform analysis: a study of senior nurse knowledge in a general intensive care unit
Resumo:
The aim of this small-scale study was to assess what knowledge senior nurses within a general intensive care unit (GICU) had in relation to intra-arterial blood pressure (IABP) waveform analysis. Its core objective was: To assess what knowledge was held by the senior nursing team with regard to arterial waveform interpretation, arterial waveform morphology and the technical aspects associated with arterial waveform monitoring.
Resumo:
The use of the Sengstaken–Blakemore tube as a life-saving treatment for bleeding oesophageal varices is slowly becoming the least preferred method possibly due to the potential complications associated with its placement. Nursing practice pertaining to the care of this patient group appears ad hoc and reliant on local knowledge and experience as opposed to recognised evidence of best practice. Therefore, this paper focuses on the application of Lewin's transitional change theory used to introduce a change in nursing practice with the application of a guideline to enhance the care of patients with a Sengstaken–Blakemore tube in situ within a general intensive care unit. This method identified some of the complexities surrounding the change process including the driving and restraining forces that must be harnessed and minimised in order for the adoption of change to be successful.
Resumo:
The aim of this small-scale study was to measure, analyse and compare levels of acoustic noise, in a nine-bedded general intensive care unit (ICU). Measurements were undertaken using the Norsonic 116 sound level meter recording noise levels in the internationally agreed ‘A’ weighted scale. Noise level data were obtained and recorded at 5 min over 3 consecutive days. Results of noise level analysis indicated that mean noise levels within this clinical area was 56·42 dB(A), with acute spikes reaching 80 dB(A). The quietest noise level attained was that of 50 dB(A) during sporadic intervals throughout the 24-h period. Parametric testing using analysis of variance found a positive relationship (p ≤ 0·001) between the nursing shifts and the day of the week. However, Scheffe multiple range testing showed significant differences between the morning shift, and the afternoon and night shifts combined (p ≤ 0·05). There was no statistical difference between the afternoon and night shifts (p ≥ 0·05). While the results of this study may seem self-evident in many respects, what it has highlighted is that the problem of excessive noise exposure within the ICU continues to go unabated. More concerning is that the prolonged effects of excessive noise exposure on patients and staff alike can have deleterious effect on the health and well-being of these individuals.
Resumo:
This small-scale study was undertaken to assess what knowledge nursing staff from a General Intensive Care Unit held with regard to noise exposure. To assess knowledge a self-administered multiple-choice questionnaire was used. Rigorous peer-review insured content validity. This study produced poor results in terms of the knowledge nurses held with regard to noise related issues in particular the psychophysiological effects and current legislation concerning its safe exposure. Non-parametric testing, using Kruskal–Wallis found no significant difference between nursing grades, however, descriptive analysis demonstrated that the staff nurse grade (D and E) performed better overall. Whilst the results of this study may seem self-evident in some respects, it is the problems of exposure to excessive noise levels for both patients and hospital personnel, which are clearly not understood. The effects noise exposure has on individuals for example decreased wound healing; sleep deprivation and cardiovascular stimulation must be of concern especially in terms of patient care but more so for nursing staff especially the effects noise levels can have on cognitive task performance.
Resumo:
Within the cardiac high dependency unit it is currently a member of the surgical team who makes the decision for a patient's chest drain to be removed after cardiac surgery. This has often resulted in delays in discharging one patient and therefore in admitting the next. A pilot study was carried out using a working standard that had been developed, incorporating an algorithmic model. The results have enabled nursing staff in a cardiac high dependency unit to undertake this responsibility independently.
Resumo:
Review question/objective The review objective is to synthesise the best available evidence on experiences and perceptions of family members of intensive care unit patients on the adequacy of end-of-life care, where life-support modalities have been withheld or withdrawn. Inclusion criteria Types of participants This review will consider studies that report on the experiences and perceptions of patients’ families on EOLC in the ICU, where life-support modalities have been withheld or withdrawn. The family is defined as “those who are closest to the patient... the family may include the biological family, family by acquisition, and the family of choice and friends”. Phenomena of interest The phenomena of interest for this review are the patients’ families experiences, perceptions or views on the adequacy of EOLC delivered in the ICU, where life-support modalities were withheld or withdrawn. These experiences may refer to the following views on domains of care considered important at the end-of-life in the ICU, which have been described already in the existing literature: timely, consistent, and compassionate communication, clinician availability, clinical decision making based on patients’ preferences, goals and values, physical care implemented to maintain patient comfort, holistic interdisciplinary care and bereavement care for families of patients who died.
Resumo:
Purpose Paper-based nutrition screening tools can be challenging to implement in the ambulatory oncology setting. The aim of this study was to determine the validity of the Malnutrition Screening Tool (MST) and a novel, automated nutrition screening system compared to a ‘gold standard’ full nutrition assessment using the Patient-Generated Subjective Global Assessment (PG-SGA). Methods An observational, cross-sectional study was conducted in an outpatient oncology day treatment unit (ODTU) within an Australian tertiary health service. Eligibility criteria were as follows: ≥18 years, receiving outpatient anticancer treatment and English literate. Patients self-administered the MST. A dietitian assessed nutritional status using the PGSGA, blinded to the MST score. Automated screening system data were extracted from an electronic oncology prescribing system. This system used weight loss over 3 to 6 weeks prior to the most recent weight record or age-categorised body mass index (BMI) to identify nutritional risk. Sensitivity and specificity against PG-SGA (malnutrition) were calculated using contingency tables and receiver operating curves. Results There were a total of 300 oncology outpatients (51.7 % male, 58.6±13.3 years). The area under the curve (AUC) for weight loss alone was 0.69 with a cut-off value of ≥1 % weight loss yielding 63 % sensitivity and 76.7 % specificity. MST (score ≥2) resulted in 70.6 % sensitivity and 69.5 % specificity, AUC 0.77. Conclusions Both the MST and the automated method fell short of the accepted professional standard for sensitivity (~≥80 %) derived from the PG-SGA. Further investigation into other automated nutrition screening options and the most appropriate parameters available electronically is warranted to support targeted service provision.
Resumo:
Background Through clinical observation nursing staff of an inpatient rehabilitation unit identified a link between incontinence and undiagnosed urinary tract infections (UTIs). Further, clinical observation and structured continence management led to the realisation that urinary incontinence often improved, or resolved completely, after treatment with antibiotics. In 2009 a small study found that 30% of admitted rehabilitation patients had an undiagnosed UTI, with the majority admitted post-orthopaedic fracture. We suspected that the frequent use of indwelling urinary catheters (IDCs) in the orthopaedic environment may have been a contributing factor. Therefore, a second, more thorough, study was commenced in 2010 and completed in 2011. Aim The aim of this study was to identify what proportion of patients were admitted to one rehabilitation unit with an undiagnosed UTI over a 12-month period. We wanted to identify and highlight the presence of known risk factors associated with UTI and determine whether urinary incontinence was associated with the presence of UTI. Methods Data were collected from every patient that was admitted over a 12-month period (n=140). The majority of patients were over the age of 65 and had an orthopaedic fracture (36.4%) or stroke (27.1%). Mid-stream urine (MSU) samples, routinely collected and sent for culture and sensitivity as part of standard admission procedure, were used by the treating medical officer to detect the presence of UTI. A data collection sheet was developed, reviewed and trialled, before official data collection commenced. Data were collected as part of usual practice and collated by a research assistant. Inferential statistics were used to analyse the data. Results This study found that 25 (17.9%) of the 140 patients admitted to rehabilitation had an undiagnosed UTI, with a statistically significant association between prior presence of an IDC and the diagnosis of UTI. Urinary incontinence improved after the completion of treatment with antibiotics. Results further demonstrated a significant association between the confirmation of a UTI on culture and sensitivity and the absence of symptoms usually associated with UTI, such as burning or stinging on urination. Overall, this study suggests careful monitoring of urinary symptoms in patients admitted to rehabilitation, especially in patients with a prior IDC, is warranted.
Resumo:
Large penetration of rooftop PVs has resulted in unacceptable voltage profile in many residential distribution feeders. Limiting real power injection from PVs to alleviate over voltage problem is not feasible due to loss of green power and hence corresponding revenue loss. Reactive capability of the PV inverter can be a solution to address over voltage and voltage dip problems to some extent. This paper proposes an algorithm to utilize reactive capability of PV inverters and investigate their effectiveness for voltage improvement based on R/X ratio of the feeder. The length and loading level of the feeder for a particular R/X ratio to have acceptable voltage profile is also investigated. This can be useful for suburban design and residential distribution planning. Furthermore, coordination among different PVs using residential smart meters via a substation based controller is also proposed.
Resumo:
Integration of rooftop PVs and increasing peak demand in the residential distribution networks has resulted in unacceptable voltage profile. Curtailing PV generation to alleviate overvoltage problem and making regular network investment to cater peak demand is not always feasible. Reactive capability of the PV inverter can be a solution to address voltage dip and over voltage problems to some extent. This paper proposes an algorithm to utilize reactive capability of PV inverters and investigate their effectiveness on feeder length and R/X ratio of the line. Feeder loading level for a particular R/X ratio to have acceptable voltage profile is also investigated. Furthermore, the need of appropriate feeder distances and R/X ratio for acceptable voltage profile, which can be useful for suburban design and distribution planning, is explored.