982 resultados para regolith porosity
Resumo:
Northeastern Brazil is mainly formed by crystalline terrains (around 60% in area). Moreover, this region presents a semi-arid climate so that it is periodically subject to drought seasons. Furthermore, ground water quality extracted fromwells usually presents poor quality because of their high salinity contents. Nevertheless, ground water is still a very important source of water for human and animal consumption in this region. Well sitting in hard rocks terrains in Northeastern Brazil offers a mean success index of aboul 60%, given that a successful siting is defined by a well producing at least 0.5 m³/h. This low index reveals lack of knowledga about the true conditions of storage and percolation of ground water in crystalline rocks. Two models for structures storing and producing ground water in crystalline rocks in Northeastem Brazil have been proposed in the literature. The first model,tradnionally used for well sitting since the sixties are controlled by faults or fractures zones. This model is commonly referred, in Brazilian hydrogeological literature, as the "creek-crack" model (riacho-fenda in Portuguese). Sites appearing to present dense drainage network are preferred for water well siting - particularly at points where the drainages cross-cul each other. Field follow up work is usually based only on geological criteria. The second model is the "eluvio-alluvial through" (calha eluvio-aluvionar in Portuguese); it is also described in the literature but it is not yet incorporated in well sitting practice. This model is based on the hypothesis that reclilinear drainages can also be controlled by the folietion of the rock. Eventually, depending upon the degree of weathering, a through-shaped structure filled with sediments (alluvium and regolith) can be developed which can store and water can be produced from. Using severalfield case studies, this Thesis presents a thorough analysis ofthe two above cited models and proposes a new model. The analysis is based on an integrated methodological approach using geophysics and structural geology. Both land (Resitiviy and Ground Penetrating Radar- GPR) and aerogeophysical (magnetics and frequency domain eletromagnetics) surveys were used. Slructural analysis emphasized neolectonic aspects; in general, itwas found that fractures in the E-W direction are relatively open, as compared to fracturas inthe N-S direction, probably because E-W fractures were opened by the neotectonic stress regime in Northeastern Brazil, which is controlled by E-W compression and N-S extension. The riacho-fenda model is valid where drainages are controlled by fractures. The degree of fracturing and associated weathering dictale the hydrogeological potential of the structure. Field work in structural analogues reveals that subvertical fractures show consistent directions both in outcrop and aerophotograph scales. Geophysical surveys reveal subvertical conductive anomalies associated to the fracture network controlling the drainage; one of the borders of the conductive anomaly usually coincide wih the drainage. An aspect of particular importance to the validation of fracture control are the possible presence of relalively deep conductive anomalies wihoul continuation or propagalion to the surface. The conductive nature of lhe anomaly is due to the presence of wealhered rock and sedirnenls (alluvium and/or regolilh) storing ground waler which occur associated to the fracture network. Magnetic surveys are not very sensisnive to these structures.lf soil or covering sedirnents are resislive (> 100 Ohm.m), GPR can ba used to image precisely lhe fracture network. A major limialion of riacho-fenda model, revealed by GPR images, is associated to the fact thal subhorizontal fractures do play a very important role in connecting the fracture network, besides connect shallow recharge zones to relalively deep subvertical frecture zones. Iffractures play just a secondary control on the drainage, however, r/acho-fenda model may have a very limiled validny; in these cases, large portions oflhe drainage do nol coincide wilh frectures and mosl oflhewells localed in lhe drainage surrounding would resull dry. Usually, a secondary conlrol on lhe drainage by Ihefraclure networkcan be revealed only wilh detailed geophysical survey. The calha elClv1o-aluvlonarmodel is valid where drainages are conlrolled by folialion. The degree 01 wealhering 01 lhe lolialion planes dictales lhe hydrogeological polenlial 01 lhe slruclure. Outcrop analysis reveals Ihal lolialion and drainage direclions are parallel and Ihal no Iraclures, orfraclures wilh diflerent directions 01 lhe drainage direclion occur. Geophysical surveys reveal conduclive anomalies in a slab lorm associaled 10 lhe Ihrough 01 lhe wealhered rock and sedimenls (alluvium and/or regolith). Magnelic surveys can ofler a very good conlrol on lolialion direclion. An importanl aspect 10 validale lolialion conlrol are lhe presence 01 conductive anomalies showing shallow and deep portions area which are linked. Illhere is an exlensive soil cover, r/acho-fenda and calha eIClv1o-aluv/onar conlrols can be easily misinlerpreled in lhe absence 01 geophysical conlrol. Certainly, Ihis lacl could explain at leasl a part of lhe failure index in well sitting. The model wealhering sack (bolsllo de Intempertsmo in Portuguese) is proposed to explain cases where a very inlensive wealhering occur over lhe crystalline rock so Ihal a secondary inlerslilial porosity is crealed. The waler is Ihen stored in lhe porous of lhe regolilh in a similar mannerlo sedimentary rocks. A possible example ofthis model was delecled by using land geophysical survey where a relalivelyvery deep isolaled conduclive anomaly, in a slab form, was delected. Iflhis structure does store ground waler, certainly Ihere must be a link 01 lhe deep slructure wilh lhe surface in orderlo provide walerfeeding. This model mighl explain anomalous waler yields as greal as 50 m³/h Ihalsomelimescan occur in crystalline rocks in Northeaslern Brazil
Resumo:
Background: Ultrasonic excitation (US) was applied to glass ionomer cement (GIC) during early set time to increase the advantageous properties of this material. Purpose: The aim of this in vitro study was to assess the inner porosity of GIC after US. Study design: A total of 16 specimens, for each material, were prepared from high-viscosity GIC Fuji IX GP, Ketac Molar, and Ketac Molar Easymix. Half of these specimens (n = 8) received 30 s of US during the initial cement setting. After completion of the material setting, specimens were fractured and observed by scanning electronic microscopy to quantitatively assay porosity inside the material using Image J software. Results: Statistical data analysis revealed that US reduced the porosity for all tested materials (P <= 0.05). The following reductions (expressed in percentages) were achieved: Fuji IX-from 3.9% to 2.8%; Ketac Molar Easy Mix-from 4.4% to 2.6%, and Ketac Molar-from 2.4% to 1.6%. Conclusion: Under the tested conditions, US was an effective method for porosity reduction inside the material. Microsc. Res. Tech. 74:54-57, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
The aim of this study was to evaluate the presence of porosities inside the glass ionomer cement (GIC) after different techniques of material insertion. MATERIAL and METHOD: Specimens were prepared with high-viscosity GIC Ketac Molar Easymix and divided into three groups according to the insertion method: spatula (PI), Centrix injector (CI), and low-cost syringe (LCS). The specimens were fractured and observed with scanning electronic microscopy to quantitatively evaluate porosity inside the material using Image J Software. RESULTS: Statistical analysis, ANOVA application, and Tukey test to significance level of 5%, revealed that there was no statistical difference between the groups. CONCLUSION: Although the use of LCS has not decreased the porosity of the material, this insertion method is easy, accessible, and low cost, which makes it a viable alternative of use in the ART technique and in others bucal health programs. Microsc. Res. Tech., 2012. (c) 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Microwave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated.The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L).Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests.MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection.Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Titanium oxide (TiO2) is a good candidate for support of hydrotreating catalysts but has the disadvantage of presenting a low surface area and a poor thermal stability when compared with Al2O3. A mixed TiO2-Al2O3 support was proposed as an alternative that is expected to be free from these drawbacks. The variation during firing of the nanoporous texture of supports composed of TiO2-Al2O3, TiO2 and Al2O3 was studied by small angle X-ray scattering (SAXS). The supports were prepared by the sol-gel route using Ti and Al isopropoxides. We have particularly analyzed the effects of acid and basic hydrolysis on the nanostructural features of catalyst supports fired at different temperatures. The nanopore radius distribution functions were determined from SAXS results assuming a simple model of spherical nanopores embedded in a homogeneous solid matrix. The modal pore radius in both pure TiO2 and pure Al2O3 supports grows from 1.3 to 2.2 nm as the firing temperature increases from 673 to 973 K. on the other hand, the modal pore radius in the mixed TiO2-Al2O3 support remains below 1.2 nm over the same range of firing temperatures. These results demonstrate the good thermal stability of the nanoporous texture of mixed TiO2-Al2O3 supports.
Resumo:
Statement of problem. Although most of the physical properties of denture base resin polymerized by microwave energy have been shown to be similar to resins polymerized by the conventional heat polymerization method, the presence of porosity is a problem.Purpose. This study evaluated the effect of different microwave polymerization cycles on the porosity of a denture base resin designed for microwave polymerization.Material and methods. Thirty-two rectangular resin specimens (65 X 40 X 5 mm) were divided into 3 experimental groups (A, B, and C; Onda-Cryl, microwave-polymerized resin) and I control group (T; Classico, heat-polymerized resin), according to the following polymerization cycles: (A) 500 W for 3 minutes, (B) 90 W for 13 minutes + 500 W for 90 seconds, (C) 320 W for 3 minutes + 0 W for 4 minutes + 720 W for 3 minutes, and (T) 74degreesC for 9 hours. Porosity was calculated by measurement of the specimen volume before and after its immersion in water. Data were analyzed using 1-way analysis of variance (alpha = .05).Results. The mean values and SDs of the percent mean porosity were: A = 1.05% +/- 0.28%, B = 0.91% +/- 0.15%, C = 0.88% +/- 0.23%, T = 0.93% +/- 0.23%. No significant differences were found in mean porosity among the groups evaluated.Conclusion. Within the limitations of this study, a denture base resin specifically designed for microwave Polymerization tested was not affected by different polymerization cycles. Porosity was similar to the conventional heat-polymerized denture base resin tested.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)