942 resultados para reactor cooling systems


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Jersey cows has been used in warm climates because they have better performance in dairy production. Generally milk production is reduced in warm climates due to the consequent reduction in feed intake because of the heat stress. When the heat stress occurs there is an increase in the body temperature, however it is not known if the skin temperature indicates a thermal discomfort or if it influences milk yield. The objective of this research was to verify if there was a correlation between skin temperature and milk yield using two treatments. Treatment (A) where the cows stayed for 30 minutes before the milking period, in a room with a shower and a fan; and treatment (B) where the cows did not had access to any cooling device (control). After milking the skin temperature were recorded in the places: forehead, back, leg and teats. Data were statistically analyzed and, even though in treatment (A) the skin temperature were reduced it was not found correlation between skin temperature and milk yield.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biometrics is one of the biggest tendencies in human identification. The fingerprint is the most widely used biometric. However considering the automatic fingerprint recognition a completely solved problem is a common mistake. The most popular and extensively used methods, the minutiae-based, do not perform well on poor-quality images and when just a small area of overlap between the template and the query images exists. The use of multibiometrics is considered one of the keys to overcome the weakness and improve the accuracy of biometrics systems. This paper presents the fusion of a minutiae-based and a ridge-based fingerprint recognition method at rank, decision and score level. The fusion techniques implemented leaded to a reduction of the Equal Error Rate by 31.78% (from 4.09% to 2.79%) and a decreasing of 6 positions in the rank to reach a Correct Retrieval (from rank 8 to 2) when assessed in the FVC2002-DB1A database. © 2008 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Climate change in tropical countries, like Brazil, causes major problems in dairy production due to an increase of heat stress effects. In recent years, milk production in Brazil increased 36.07%. The Southeast region remains a leader in production with herds of high producing Holstein cattle (mostly), which is more susceptible to heat stress. Thermal stress decreases fertility in direct and indirect ways. Conception rates are reduced of 40-60% during cooler months of the year and 10-20% in the warmer months. Negative effects of heat stress involve changes in reproductive hormones, follicular development, oocytes, and embryos, and decreased dry matter intake. Several studies discuss change in reproductive hormones, such as reduction in plasma concentration of GnRH, LH, and oestradiol, which lead to decreased detection of estrus and ovulation. Various methods are being studied to bypass these negative effects and increase the fertility of dairy cows under heat stress. Cooling systems are the most advantageous and can be associated with technologies such as ET and TAI

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tra i temi di attualità, quello del risparmio energetico è tra i più dibattuti negli ultimi anni; tale tema è strettamente correlato al problema del riscaldamento globale, infatti, mentre sul prossimo esaurimento delle risorse energetiche tradizionali non vi sono ancora certezze assolute, per quanto riguarda l’azione nociva dei gas serra, la Comunità Scientifica Internazionale si ritrova d’accordo su una netta presa di posizione contro l’emissione di tali sostanze, provocata in larga parte dall’utilizzo dei combustibili fossili. In questo contesto, l’Unione Europea sta promuovendo la diffusione di tecnologie che non prevedano l’utilizzo di gas, petrolio o carbone, soprattutto per il settore dell’edilizia, ove una corretta progettazione e l’utilizzo di tecnologie non convenzionali può portare alla riduzione anche dell’80% dei consumi, con conseguente abbattimento delle emissioni. Tra questi interventi innovativi, il più comune e conosciuto è sicuramente quello del solare termico e fotovoltaico; ma ne esistono anche di altri, ancora non molto pubblicizzati in Italia, ma ampiamente conosciuti e utilizzati in altri paesi dell’Unione. Tra questi, vi è il sistema di riscaldamento analizzato in questa tesi: la pompa di calore geotermica. Tale sistema, come verrà spiegato nell’elaborato di laurea, ha indubbi vantaggi economici, energetici ed ambientali, a fronte di una non trascurabile spesa iniziale. Attualmente, nel Nord Italia, si incominciano a vedere impianti di questo tipo, sulla scia del successo riscontrato nei paesi confinanti (in particolare Austria e Svizzera). La progettazione si basa attualmente su modelli statici, sviluppati dall’Università Svizzera del Canton Ticino, per l’utilizzo della pompa di calore nel territorio alpino. Obiettivo della tesi, è la verifica di tali modelli, di cui si è venuto a conoscenza grazie alla collaborazione con l’Università SUPSI, sulle condizioni idrogeologiche della Pianura Padana, soffermandosi su alcuni parametri fondamentali della progettazione di una pompa di calore geotermica, quali la conduttività e la capacità termica volumetrica dei terreni incontrati, la presenza di falde, ed i parametri geometrici del pozzo, al fine di dare una valutazione tecnica ed economica dell’impianto. Tali analisi è stata infatti fino ad ora affrontata in maniera sommaria dai perforatori, che eseguono generalmente sempre lo stesso modello di pozzo geotermico, sulla base degli esempi consolidati di Svizzera e Germania. Alcune misure di temperatura in situ sono state rilevate in collaborazione con la società Geotermia SRL di Mantova, ditta specializzata nella perforazione di pozzi geotermici (tale esperienza è parte centrale dell’estratto “Laboratorio di Tesi Ls”), mentre la parte modellistica della tesi è stata sviluppata in collaborazione con lo studio di progettazione Studio Seta SRL di Faenza, il cui stabile è climatizzato in parte con una pompa di calore geotermica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sodium hypochlorite (NaOCl) is widely used to disinfect seawater in power plant cooling systems in order to reduce biofouling, and in ballast water treatment systems to prevent transport of exotic marine species. While the toxicity of NaOCl is expected to increase by ongoing ocean acidification, and many experimental studies have shown how algal calcification, photosynthesis and growth respond to ocean acidification, no studies have investigated the relationship between NaOCl toxicity and increased CO2. Therefore, we investigated whether the impacts of NaOCl on survival, chlorophyll a (Chl-a), and effective quantum yield in three marine phytoplankton belonging to different taxonomic classes are increased under high CO2 levels. Our results show that all biological parameters of the three species decreased under increasing NaOCl concentration, but increasing CO2 concentration alone (from 450 to 715 µatm) had no effect on any of these parameters in the organisms. However, due to the synergistic effects between NaOCl and CO2, the survival and Chl-a content in two of the species, Thalassiosira eccentrica and Heterosigma akashiwo, were significantly reduced under high CO2 when NaOCl was also elevated. The results show that combined exposure to high CO2 and NaOCl results in increasing toxicity of NaOCl in some marine phytoplankton. Consequently, greater caution with use of NaOCl will be required, as its use is widespread in coastal waters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transportation Department, Office of Noise Abatement, Washington, D.C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increased device density, switching speeds of integrated circuits and decrease in package size is placing new demands for high power thermal-management. The convectional method of forced air cooling with passive heat sink can handle heat fluxes up-to 3-5W/cm2; however current microprocessors are operating at levels of 100W/cm2, This demands the usage of novel thermal-management systems. In this work, water-cooling systems with active heat sink are embedded in the substrate. The research involved fabricating LTCC substrates of various configurations - an open-duct substrate, the second with thermal vias and the third with thermal vias and free-standing metal columns and metal foil. Thermal testing was performed experimentally and these results are compared with CFD results. An overall thermal resistance for the base substrate is demonstrated to be 3.4oC/W-cm2. Addition of thermal vias reduces the effective resistance of the system by 7times and further addition of free standing columns reduced it by 20times.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The internal combustion (IC) engines exploits only about 30% of the chemical energy ejected through combustion, whereas the remaining part is rejected by means of cooling system and exhausted gas. Nowadays, a major global concern is finding sustainable solutions for better fuel economy which in turn results in a decrease of carbon dioxide (CO2) emissions. The Waste Heat Recovery (WHR) is one of the most promising techniques to increase the overall efficiency of a vehicle system, allowing the recovery of the heat rejected by the exhaust and cooling systems. In this context, Organic Rankine Cycles (ORCs) are widely recognized as a potential technology to exploit the heat rejected by engines to produce electricity. The aim of the present paper is to investigate a WHR system, designed to collect both coolant and exhausted gas heats, coupled with an ORC cycle for vehicle applications. In particular, a coolant heat exchanger (CLT) allows the heat exchange between the water coolant and the ORC working fluid, whereas the exhausted gas heat is recovered by using a secondary circuit with diathermic oil. By using an in-house numerical model, a wide range of working conditions and ORC design parameters are investigated. In particular, the analyses are focused on the regenerator location inside the ORC circuits. Five organic fluids, working in both subcritical and supercritical conditions, have been selected in order to detect the most suitable configuration in terms of energy and exergy efficiencies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ground-source heat pump (GSHP) systems represent one of the most promising techniques for heating and cooling in buildings. These systems use the ground as a heat source/sink, allowing a better efficiency thanks to the low variations of the ground temperature along the seasons. The ground-source heat exchanger (GSHE) then becomes a key component for optimizing the overall performance of the system. Moreover, the short-term response related to the dynamic behaviour of the GSHE is a crucial aspect, especially from a regulation criteria perspective in on/off controlled GSHP systems. In this context, a novel numerical GSHE model has been developed at the Instituto de Ingeniería Energética, Universitat Politècnica de València. Based on the decoupling of the short-term and the long-term response of the GSHE, the novel model allows the use of faster and more precise models on both sides. In particular, the short-term model considered is the B2G model, developed and validated in previous research works conducted at the Instituto de Ingeniería Energética. For the long-term, the g-function model was selected, since it is a previously validated and widely used model, and presents some interesting features that are useful for its combination with the B2G model. The aim of the present paper is to describe the procedure of combining these two models in order to obtain a unique complete GSHE model for both short- and long-term simulation. The resulting model is then validated against experimental data from a real GSHP installation.