933 resultados para range of motion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the mid-1940s, American film industry was on its way up to its golden era as studios started mass-producing iconic feature films. The escalating increase in popularity of Hollywood stars was actively suggested for its direct links to box office success by academics. Using data collected in 2007, this paper carries out an empirical investigation on how different factors, including star power, affect the revenue of ‘home-run’ movies in Hollywood. Due to the subjective nature of star power, two different approaches were used: (1) number of nominations and wins of Academy Awards by the key players, and (2) average lifetime gross revenue of films involving the key players preceding the sample year. It is found that number of Academy awards nominations and wins was not statistically significant in generating box office revenue, whereas star power based on the second approach was statistically significant. Other significant factors were critics’ reviews, screen coverage and top distributor, while number of Academy awards, MPAA-rating, seasonality, being a sequel and popular genre were not statistically significant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose Third generation anatomic total shoulder prostheses offer a wide range of adaptability (size, thickness, retroversion and offset of the humeral head, cervico-diaphyseal angle) in order to reproduce anatomy and biomechanics of the shoulder as normal as possible. The large variability of the implants may also induce malposition. Our goal was to analyse the consequences of a humeral head malposition, which is one of the most frequent placement errors. Material and Methods A 3D finite element model of the glenohumeral joint, including the rotator cuff muscles and the deltoid, was used with the Aequalis anatomic prosthesis. Active abduction was simulated. Three humeral head placements were compared : anatomic positioning (A), 5 mm inferior positioning (B), 5 mm superior positioning (C). The effect of humeral head malposition was evaluated through the following quantities : the range of motion free of impingements, the glenohumeral contact pattern, and the stress within the polyethylene and the cement. Results Inferior positioning (B) of the humeral head produced a superior impingement before 90° of abduction, an inferior eccentric contact point on the glenoid, and 165% increase of cement stress. Superior positioning (C) of the humeral head produced a postero-superior eccentric contact point on the glenoid, 300% increase of glenohumeral contact pressure, 450% increase of polyethylene stress, and 207% increase of cement stress. Conclusion Malposition of the humeral head of anatomic prostheses induces biomechanical consequences that may preclude the glenoid survival. Particular attention must be paid to reproduce the humeral anatomy as normal as possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To document the neurological outcome, spinal alignment and segmental range of movement after oblique cervical corpectomy (OCC) for cervical compressive myelopathy. METHODS: This retrospective study included 109 patients--93 with cervical spondylotic myelopathy and 16 with ossified posterior longitudinal ligament in whom spinal curvature and range of segmental movements were assessed on neutral and dynamic cervical radiographs. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. Eighty-eight patients (81%) underwent either a single- or two-level corpectomy; the remaining (19%) undergoing three- or four-level corpectomies. The average duration of follow-up was 30.52 months. RESULTS: The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). The mean postoperative segmental angle in the neutral position straightened by 4.7 ± 6.5°. The residual segmental range of movement for a single-level corpectomy was 16.7° (59.7% of the preoperative value), for two-level corpectomy it was 20.0° (67.2%) and for three-level corpectomies it was 22.9° (74.3%). 63% of patients with lordotic spines continued to have lordosis postoperatively while only one became kyphotic without clinical worsening. Four patients with preoperative kyphotic spines showed no change in spine curvature. None developed spinal instability. CONCLUSIONS: The OCC preserves segmental motion in the short-term, however, the tendency towards straightening of the spine, albeit without clinical worsening, warrants serial follow-up imaging to determine whether this motion preservation is long lasting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By this study we seek the expectable range of waist circumference (WC) for every degree of body mass index (BMI), which will serve to studies targeting ascertaining the health risk. We studied 2,932 patients (39.6% men and 60.4% women, between 18 and 96 years ) of the same ethnic group who consecutively attended outpatient departments of our clinics between 2000 and 2004. BMI correlated linearly with the WC (cc: 0.85; p < 0.001). The men, the obese, and diabetics were older (p < 0.001). BMI was greater in women and WC in men. The women had a greater WC if they had diabetes (p < 0.01), being equal to diabetic males. The men had greater WC when they had diabetes (p < 0.001). Waist at risk was detected (men > or = 102 cm and women > or = 88 cm) in 94.3% of the obese, in 32.3% of overweight patients, in 3.8% of patients with BMI < 25, in 84.3% of diabetics, and in 72.6% of patients without diabetes. We made graphic standardisation of WC with regard to BMI, and we calculated the percentiles 10, 25, 50, 75 and 90, grouping in ranges of 2 kg/m(2) of BMI. The diabetic patients are grouped in ranges of 4 kg/m(2). As conclusion we present a standardisation of the WC measurement of patients attended to in our Endocrinology and Nutrition practices distributed in percentiles as a clinically usable tool to define the ranges of WC for every BMI value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to retrospectively evaluate 18 consecutive cases of peritalar dislocations referred to our department during a period of 25 years and to delineate the factors influencing long-term prognosis. There were 13 (73%) medial and 5 (27%) lateral dislocations. Six patients (33%) suffered an open injury, including 2 of 13 (15%) medial and 4 of 5 (80%) lateral dislocations. Associated fractures involving the hindfoot or forefoot were noted in 7 feet, including 3 of 5 lateral dislocation cases. Reduction was accomplished under general anesthesia; in no case was open reduction necessary. In 4 of 6 open injuries with associated fractures, temporary fixation with Kirschner wires was performed. Patients were immobilized in a plaster cast for 4 weeks, or for 6 weeks in the presence of fracture, followed by weightbearing as tolerated. At a mean follow-up of 10.2 years (range, 4 to 26 years), 10 patients (56%) showed excellent results; all had sustained a closed medial low-energy dislocation. There were 3 cases (17%) with fair results and 5 cases (28%) with poor results. Forty-five percent of patients showed a restriction of activity, a reduction of subtalar range of motion, and moderate or severe radiographic signs of hindfoot degenerative arthritis. There were no cases of talar avascular necrosis, and in no case was secondary surgery necessary. Lateral dislocation and open medial dislocations with concomitant fractures showed a greater potential for poor prognosis. The results were independent from period of cast immobilization, suggesting that 4 to 6 weeks of immobilization provides acceptable long-term results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Hamstring injuries continue to affect active individuals and although inadequate muscle extensibility remains a commonly accepted factor, little is known about the most effective method to improve flexibility. Purpose. To determine if an isolated neurodynamic sciatic sliding technique would improve hamstring flexibility to a greater degree than stretching or a placebo intervention in asymptomatic subjects with short hamstring syndrome (SHS). Study Design. Randomized double-blinded controlled trial. Methods. One hundred and twenty subjects with SHS were randomized to 1 of 3 groups: neurodynamic sliding, hamstring stretching, and placebo control. Each subject's dominant leg was measured for straight leg raise (SLR) range of motion (ROM) before and after interventions. Data were analyzed with a 3 × 2 mixed model ANOVA followed by simple main effects analyses. Results. At the end of the study, more ROM was observed in the Neurodynamic and Stretching groups compared to the Control group and more ROM in the Neurodynamic group compared to Stretching group. Conclusion. Findings suggest that a neurodynamic sliding technique will increase hamstring flexibility to a greater degree than static hamstring stretching in healthy subjects with SHS. Clinical Relevance. The use of neurodynamic sliding techniques to improve hamstring flexibility in sports may lead to a decreased incidence in injuries; however, this needs to be formally tested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Nonoperative treatment of displaced midshaft clavicle fractures is associated with higher nonunion rate than previously reported. Moreover, its occurrence can compromise shoulder function. The aim of this study was to evaluate the outcome of surgical treatment of symptomatic clavicle midshaft delayed and nonunion. Methods: Between 1999 and 2008, 19 clavicle delayed unions and nonunions were treated by open reduction and reconstructive plate fixation with augmentation by autologous bone graft. Iliac bone graft was used in 15 atrophic cases, and graft from the callus was used in 4 hypertrophic nonunions. There were 14 men and 5 women, with an average age of 41 years (range, 19 to 59 years) at time of surgery. No patient had undergone a previous surgery and all complained of shoulder pain. Delayed unions and nonunions were defined as non-healing after 3 and 6 months respectively. The mean time to surgery was 8 months (range, 4 to 23 months). All patients were pre and postoperatively clinically evaluated and imaged with standard radiographs until complete healing. Results: After a mean time of 3 months (range, 2 to 7 months) all fractures were completely healed. All patients reported full range of motion at time of last follow-up. Nine patients (47%) reported slight shoulder pain but all returned to their previous professional activities after a mean time of 3 months (range, 1 to 8 months). We reported 12 (63%) minor complications. There were 6 (32%) plate-related discomforts which resolved after hardware removal, two (11%) scar numbness, two (11%) adhesive capsulitis with spontaneous complete recovery, and two (11%) AC-joint pain treated successfully with local corticosteroids injection. Conclusion: Surgical treatment of delayed unions and nonunions of midshaft clavicle fractures yields satisfactory results and a high union rate. However, 50% of the patients may still complain of slight residual shoulder pain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.