939 resultados para quality testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid crystal on silicon (LCOS) for phase-only holography is ideally made to better optical tolerance than that for conventional amplitude modulating applications. Die-level assembly is suited to custom devices and pre-production prototypes because of its flexibility and efficiency in conserving the silicon backplane. Combined with automated assembly, it will allow high reproducibility and fast turnaround time, paving the way for pre-production testing and customer sampling before mass production. Pre-assembly optical testing is the key element in the process. By taking into account the flatness of both the backplane and the front glass plate, we have assembled high quality LCOS devices. We have reached our aim of less than one quarter wavelength phase distortion across the active area. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Smart and mobile environments require seamless connections. However, due to the frequent process of ''discovery'' and disconnection of mobile devices while data interchange is happening, wireless connections are often interrupted. To minimize this drawback, a protocol that enables an easy and fast synchronization is crucial. Bearing this in mind, Bluetooth technology appears to be a suitable solution to carry on such connections due to the discovery and pairing capabilities it provides. Nonetheless, the time and energy spent when several devices are being discovered and used at the same time still needs to be managed properly. It is essential that this process of discovery takes as little time and energy as possible. In addition to this, it is believed that the performance of the communications is not constant when the transmission speeds and throughput increase, but this has not been proved formally. Therefore, the purpose of this project is twofold: Firstly, to design and build a framework-system capable of performing controlled Bluetooth device discovery, pairing and communications. Secondly, to analyze and test the scalability and performance of the \emph{classic} Bluetooth standard under different scenarios and with various sensors and devices using the framework developed. To achieve the first goal, a generic Bluetooth platform will be used to control the test conditions and to form a ubiquitous wireless system connected to an Android Smartphone. For the latter goal, various stress-tests will be carried on to measure the consumption rate of battery life as well as the quality of the communications between the devices involved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The advent of molecular biology has had a dramatic impact on all aspects of biology, not least applied microbial ecology. Microbiological testing of water has traditionally depended largely on culture techniques. Growing understanding that only a small proportion of microbial species are culturable, and that many microorganisms may attain a viable but non-culturable state, has promoted the development of novel approaches to monitoring pathogens in the environment. This has been paralleled by an increased awareness of the surprising genetic diversity of natural microbial populations. By targeting gene sequences that are specific for particular microorganisms, for example genes that encode diagnostic enzymes, or species-specific domains of conserved genes such as 16S ribosomal RNA coding sequences (rrn genes), the problems of culture can be avoided. Technical developments, notably in the area of in vitro amplification of DNA using the polymerase chain reaction (PCR), now permit routine detection and identification of specific microorganisms, even when present in very low numbers. Although the techniques of molecular biology have provided some very powerful tools for environmental microbiology, it should not be forgotten that these have their own drawbacks and biases in sampling. For example, molecular techniques are dependent on efficient lysis and recovery of nucleic acids from both vegetative forms and spores of microbial species that may differ radically when growing in the laboratory compared with the natural environment. Furthermore, PCR amplification can introduce its own bias depending on the nature of the oligonucleotide primers utilised. However, despite these potential caveats, it seems likely that a molecular biological approach, particularly with its potential for automation, will provide the mainstay of diagnostic technology for the foreseeable future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

All imported salted, dried fish samples tested had a salt content below 30% and above 12% and hence met requirements of the proposed standard. Also samples without quality cut tested had a greater salt content than that with quality cut. This indicates that salt contributes to protecting dried fish and hence may be endorsed by sensory evaluation to a certain extent. Samples with quality cut had more moisture than that without quality cut. But all samples with and without quality cut had a moisture content greater than 35% which is the maximum moisture content for such species specified in the standard. Microbiological testing for total counts and Coliform contents too showed that good quality dried fish had counts greater than that specified in the standard. The different species of fish tested had varying lengths of shelf life. But on an average the shelf life of dried fish could be prolonged for about 12 days by re-drying at 45°C for 6 hours, i.e., re-drying at these temperatures without subsequent packing in polythene bags may not be practical for prolonging the storage life of salted/dried fish.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanical properties and fracture behavior of silicon nitride (SiNx) thin film fabricated by plasma-enhanced chemical vapor deposition is reported. Plane-strain moduli, prestresses, and fracture strengths of silicon nitride thin film; deposited both oil a bare Si substrate and oil a thermally oxidized Si substrate were extracted using bulge testing combined with a refined load-deflection model of long rectangular membranes. The plane-strain modu i and prestresses of SiNx thin films have little dependence on the substrates, that is, for the bare Si substrate, they are 133 +/- 19 GPa and 178 +/- 22 MPa, respectively, while for the thermally oxidized substrate, they are 140 +/- 26 Gila and 194 +/- 34 MPa, respectively. However, the fracture strength values of SiNx films grown on the two substrates are quite different, i.e., 1.53 +/- 0.33 Gila and 3.08 +/- 0.79 GPa for the bare Si substrate a A the oxidized Si substrate, respectively. The reference stresses were computed by integrating the local stress of the membrane at the fracture over the edge, Surface, and volume of the specimens and fitted with the Weibull distribution function. For SiNx thin film produced oil the bare Si Substrate, the Volume integration gave a significantly better agreement between data and model, implying that the volume flaws re the dominant fracture origin. For SiNx thin film grown on the oxidized Si substrate, the fit quality of surface and edge integration was significantly better than the Volume integration, and the dominant surface and edge flaws could be caused by buffered HF attacking the SiNx layer during SiO2 removal. Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increased plasmin and plasminogen levels and elevated somatic cell counts (SCC) and polymorphonuclear leucocyte levels (PMN) were evident in late lactation milk. Compositional changes in these milks were associated with increased SCC. The quality of late lactation milks was related to nutritional status of herds, with milks from herds on a high plane of nutrition having composition and clotting properties similar to, or superior to, early-mid lactation milks. Nutritionally-deficient cows had elevated numbers of polymorphonuclear leucocytes (PMNs) in their milk, elevated plasmin levels and increased overall proteolytic activity. The dominant effect of plasmin on proteolysis in milks of low SCC was established. When present in elevated numbers, somatic cells and PMNs in particular had a more significant influence on the proteolysis of both raw and pasteurised milks than plasmin. PMN protease action on the caseins showed proteolysis products of two specific enzymes, cathepsin B and elastase, which were also shown in high SCC milk. Crude extracts of somatic cells had a high specificity on αs1-casein. Cheeses made from late lactation milks had increased breakdown of αs1-casein, suggestive of the action of somatic cell proteinases, which may be linked to textural defects in cheese. Late lactation cheeses also showed decreased production of small peptides and amino acids, the reason for which is unknown. Plasmin, which is elevated in activity in late lactation milk, accelerated the ripening of Gouda-type cheese, but was not associated with defects of texture or flavour. The retention of somatic cell enzymes in cheese curd was confirmed, and a potential role in production of bitter peptides identified. Cheeses made from milks containing high levels of PMNs had accelerated αs1-casein breakdown relative to cheeses made from low PMN milk of the same total SCC, consistent with the demonstrated action of PMN proteinases. The two types of cheese were determined significantly different by blind triangle testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: This thesis examines a question posed by founding occupational scientist Dr. Elizabeth Yerxa (1993) – “what is the relationship between human engagement in a daily round of activity (such as work, play, rest and sleep) and the quality of life people experience including their healthfulness” (p. 3). Specifically, I consider Yerxa’s question in relation to the quotidian activities and health-related quality of life (HRQoL) of late adolescents (aged 15 - 19 years) in Ireland. This research enquiry was informed by an occupational perspective of health and by population health, ecological, and positive youth development perspectives. Methods: This thesis is comprised of five studies. Two scoping literature reviews informed the direction of three empirical studies. In the latter, cross-sectional time use and HRQoL data were collected from a representative sample of 731 school-going late adolescents (response rate 52%) across 28 schools across Cork city and county (response rate 76%). In addition to socio-demographic data, time use data were collected using a standard time diary instrument while a nationally and internationally validated instrument, the KIDSCREEN-52, was used to measure HRQoL. Variable-centred and person-centred analyses were used. Results: The scoping reviews identified the lack of research on well populations or an adolescent age range within occupational therapy and occupational science; limited research testing the popular assumption that time use is related to overall well-being and quality of life; and the absence of studies that examined adolescent 24-hour time use and quality of life. Established international trends were mirrored in the findings of the examination of weekday and weekend time use. Aggregate-level, variable-centred analyses yielded some significant associations between HRQoL and individual activities, independent of school year, school location, family context, social class, nationality or diary day. The person-centred analysis of overall time use identified three male profiles (productive, high leisure and all-rounder) and two female profiles (higher study/lower leisure and moderate study/higher leisure). There was tentative support for the association between higher HRQoL and more balanced time use profiles. Conclusion: The findings of this thesis highlight the gendered nature of adolescent time use and HRQoL. Participation in daily activities, singly and in combination, appears to be associated with HRQoL. However, the nature of this relationship is complex. Individually and collectively, adolescents need to be educated and supported to create health through their everyday patterns of doing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Web-based decision aids are increasingly important in medical research and clinical care. However, few have been studied in an intensive care unit setting. The objectives of this study were to develop a Web-based decision aid for family members of patients receiving prolonged mechanical ventilation and to evaluate its usability and acceptability. METHODS: Using an iterative process involving 48 critical illness survivors, family surrogate decision makers, and intensivists, we developed a Web-based decision aid addressing goals of care preferences for surrogate decision makers of patients with prolonged mechanical ventilation that could be either administered by study staff or completed independently by family members (Development Phase). After piloting the decision aid among 13 surrogate decision makers and seven intensivists, we assessed the decision aid's usability in the Evaluation Phase among a cohort of 30 surrogate decision makers using the Systems Usability Scale (SUS). Acceptability was assessed using measures of satisfaction and preference for electronic Collaborative Decision Support (eCODES) versus the original printed decision aid. RESULTS: The final decision aid, termed 'electronic Collaborative Decision Support', provides a framework for shared decision making, elicits relevant values and preferences, incorporates clinical data to personalize prognostic estimates generated from the ProVent prediction model, generates a printable document summarizing the user's interaction with the decision aid, and can digitally archive each user session. Usability was excellent (mean SUS, 80 ± 10) overall, but lower among those 56 years and older (73 ± 7) versus those who were younger (84 ± 9); p = 0.03. A total of 93% of users reported a preference for electronic versus printed versions. CONCLUSIONS: The Web-based decision aid for ICU surrogate decision makers can facilitate highly individualized information sharing with excellent usability and acceptability. Decision aids that employ an electronic format such as eCODES represent a strategy that could enhance patient-clinician collaboration and decision making quality in intensive care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To evaluate pretreatment hepatitis B virus (HBV) testing, vaccination, and antiviral treatment rates in Veterans Affairs patients receiving anti-CD20 Ab for quality improvement. METHODS: We performed a retrospective cohort study using a national repository of Veterans Health Administration (VHA) electronic health record data. We identified all patients receiving anti-CD20 Ab treatment (2002-2014). We ascertained patient demographics, laboratory results, HBV vaccination status (from vaccination records), pharmacy data, and vital status. The high risk period for HBV reactivation is during anti-CD20 Ab treatment and 12 mo follow up. Therefore, we analyzed those who were followed to death or for at least 12 mo after completing anti-CD20 Ab. Pretreatment serologic tests were used to categorize chronic HBV (hepatitis B surface antigen positive or HBsAg+), past HBV (HBsAg-, hepatitis B core antibody positive or HBcAb+), resolved HBV (HBsAg-, HBcAb+, hepatitis B surface antibody positive or HBsAb+), likely prior vaccination (isolated HBsAb+), HBV negative (HBsAg-, HBcAb-), or unknown. Acute hepatitis B was defined by the appearance of HBsAg+ in the high risk period in patients who were pretreatment HBV negative. We assessed HBV antiviral treatment and the incidence of hepatitis, liver failure, and death during the high risk period. Cumulative hepatitis, liver failure, and death after anti-CD20 Ab initiation were compared by HBV disease categories and differences compared using the χ(2) test. Mean time to hepatitis peak alanine aminotransferase, liver failure, and death relative to anti-CD20 Ab administration and follow-up were also compared by HBV disease group. RESULTS: Among 19304 VHA patients who received anti-CD20 Ab, 10224 (53%) had pretreatment HBsAg testing during the study period, with 49% and 43% tested for HBsAg and HBcAb, respectively within 6 mo pretreatment in 2014. Of those tested, 2% (167/10224) had chronic HBV, 4% (326/7903) past HBV, 5% (427/8110) resolved HBV, 8% (628/8110) likely prior HBV vaccination, and 76% (6022/7903) were HBV negative. In those with chronic HBV infection, ≤ 37% received HBV antiviral treatment during the high risk period while 21% to 23% of those with past or resolved HBV, respectively, received HBV antiviral treatment. During and 12 mo after anti-CD20 Ab, the rate of hepatitis was significantly greater in those HBV positive vs negative (P = 0.001). The mortality rate was 35%-40% in chronic or past hepatitis B and 26%-31% in hepatitis B negative. In those pretreatment HBV negative, 16 (0.3%) developed acute hepatitis B of 4947 tested during anti-CD20Ab treatment and follow-up. CONCLUSION: While HBV testing of Veterans has increased prior to anti-CD20 Ab, few HBV+ patients received HBV antivirals, suggesting electronic health record algorithms may enhance health outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Describe the methodology and selection of quality indicators (QI) to be implemented in the EFFECT (EFFectiveness of Endometrial Cancer Treatment) project. EFFECT aims to monitor the variability in Quality of Care (QoC) of uterine cancer in Belgium, to compare the effectiveness of different treatment strategies to improve the QoC and to check the internal validity of the QI to validate the impact of process indicators on outcome. Methods A QI list was retrieved from literature, recent guidelines and QI databases. The Belgian Healthcare Knowledge Center methodology was used for the selection process and involved an expert's panel rating the QI on 4 criteria. The resulting scores and further discussion resulted in a final QI list. An online EFFECT module was developed by the Belgian Cancer Registry including the list of variables required for measuring the QI. Three test phases were performed to evaluate the relevance, feasibility and understanding of the variables and to test the compatibility of the dataset. Results 138 QI were considered for further discussion and 82 QI were eligible for rating. Based on the rating scores and consensus among the expert's panel, 41 QI were considered measurable and relevant. Testing of the data collection enabled optimization of the content and the user-friendliness of the dataset and online module. Conclusions This first Belgian initiative for monitoring the QoC of uterine cancer indicates that the previously used QI selection methodology is reproducible for uterine cancer. The QI list could be applied by other research groups for comparison. © 2013 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to develop a quality control tool based on rheological test methods for solder paste and flux media. Design/methodology/approach – The rheological characterisation of solder pastes and flux media was carried out through the creep-recovery, thixotropy and viscosity test methods. A rheometer with a parallel plate measuring geometry of 40mm diameter and a gap height of 1mm was used to characterise the paste and associated flux media. Findings – The results from the study showed that the creep-recovery test can be used to study the deformation and recovery of the pastes, which can be used to understand the slump behaviour in solder pastes. In addition, the results from the thixotropic and viscosity test were unsuccessful in determining the differences in the rheological flow behaviour in the solder pastes and the flux medium samples. Research limitations/implications – More extensive rheological and printing testing is needed in order to correlate the findings from this study with the printing performance of the pastes. Practical implications – The rheological test method presented in the paper will provide important information for research and development, quality control and production staff to facilitate the manufacture of solder pastes and flux media. Originality/value – The paper explains how the rheological test can be used as a quality control tool to identify the suitability of a developmental solder paste and flux media used for the printing process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of in situ measurements is essential in the validation and evaluation of the algorithms that provide coastal water quality data products from ocean colour satellite remote sensing. Over the past decade, various types of ocean colour algorithms have been developed to deal with the optical complexity of coastal waters. Yet there is a lack of a comprehensive intercomparison due to the availability of quality checked in situ databases. The CoastColour Round Robin (CCRR) project, funded by the European Space Agency (ESA), was designed to bring together three reference data sets using these to test algorithms and to assess their accuracy for retrieving water quality parameters. This paper provides a detailed description of these reference data sets, which include the Medium Resolution Imaging Spectrometer (MERIS) level 2 match-ups, in situ reflectance measurements, and synthetic data generated by a radiative transfer model (HydroLight). These data sets, representing mainly coastal waters, are available from doi:10.1594/PANGAEA.841950. The data sets mainly consist of 6484 marine reflectance (either multispectral or hyperspectral) associated with various geometrical (sensor viewing and solar angles) and sky conditions and water constituents: total suspended matter (TSM) and chlorophyll a (CHL) concentrations, and the absorption of coloured dissolved organic matter (CDOM). Inherent optical properties are also provided in the simulated data sets (5000 simulations) and from 3054 match-up locations. The distributions of reflectance at selected MERIS bands and band ratios, CHL and TSM as a function of reflectance, from the three data sets are compared. Match-up and in situ sites where deviations occur are identified. The distributions of the three reflectance data sets are also compared to the simulated and in situ reflectances used previously by the International Ocean Colour Coordinating Group (IOCCG, 2006) for algorithm testing, showing a clear extension of the CCRR data which covers more turbid waters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since 1995, when pumps were withdrawn from deep mines in East Fife (Scotland), mine waters have been rebounding throughout the coalfield. Recently, it has become necessary to pump and treat these waters to prevent their uncontrolled emergence at the surface. However, even relatively shallow pumping to surface treatment lagoons of the initially chemically-stratified mine water from a shaft in the coastal Frances Colliery during two dynamic step-drawdown tests to establish the hydraulic characteristics of the system resulted in rapid breakdown of the stratification within 24 h and a poor pumped water quality with high dissolved Fe loading. Further, data are presented here of hydrochemical and isotopic sampling of the extended pump testing lasting up to several weeks. The use in particular of the environmental isotopes d18O, d2H, d34S, 3H, 13C and 14C alongside hydrochemical and hydraulic pump test data allowed characterisation of the Frances system dynamics, mixing patterns and water quality sources feeding into this mineshaft under continuously pumped conditions. The pumped water quality reflects three significant components of mixing: shallow freshwater, seawater, and leakage from the surface treatment lagoons. In spite of the early impact of recirculating lagoon waters on the hydrochemistries, the highest Fe loadings in the longer-term pumped waters are identified with a mixed freshwater–seawater component affected by pyrite oxidation/melanterite dissolution in the subsurface system.