902 resultados para post mortem interval
Resumo:
Fractures and soft-tissue injuries of the neck are of great importance in forensic pathology, as they help in assessing whether strangulation took place, and if so, how severely. In this study, we examined the usefulness of post-mortem imaging with multislice computed tomography (MSCT) in detecting lesions of the laryngohyoid structures and the surrounding soft-tissues. For this purpose, we examined MSCT images of the neck of eight deceased persons who had suffered different types of strangulation and compared the findings with those obtained at the subsequent forensic autopsy. In six of the eight cases (75%), the fracture findings at autopsy were concordant with those found with MSCT. In the two non-congruent cases, MSCT revealed fractures, which were not discovered at autopsy. Soft-tissue haemorrhages were detected by autopsy in five cases, but only in one case with MSCT. MSCT does not suffice in detecting soft-tissue injuries. These preliminary results are promising regarding the detection of fractures in strangulation cases. If these results can be confirmed in larger studies, we believe that post-mortem MSCT may serve - in combination with a thorough external examination and a profound incident-scene investigation - as a useful decision-making tool regarding the necessity of further examinations, i.e. autopsy.
Resumo:
OBJECTIVES: This study aimed to investigate post-mortem magnetic resonance imaging (pmMRI) for the assessment of myocardial infarction and hypointensities on post-mortem T2-weighted images as a possible method for visualizing the myocardial origin of arrhythmic sudden cardiac death. BACKGROUND: Sudden cardiac death has challenged clinical and forensic pathologists for decades because verification on post-mortem autopsy is not possible. pmMRI as an autopsy-supporting examination technique has been shown to visualize different stages of myocardial infarction. METHODS: In 136 human forensic corpses, a post-mortem cardiac MR examination was carried out prior to forensic autopsy. Short-axis and horizontal long-axis Images were acquired in situ on a 3-T system. RESULTS: In 76 cases, myocardial findings could be documented and correlated to the autopsy findings. Within these 76 study cases, a total of 124 myocardial lesions were detected on pmMRI (chronic: 25; subacute: 16; acute: 30; and peracute: 53). Chronic, subacute, and acute infarction cases correlated excellently to the myocardial findings on autopsy. Peracute infarctions (age range: minutes to approximately 1 h) were not visible on macroscopic autopsy or histological examination. Peracute infarction areas detected on pmMRI could be verified in targeted histological investigations in 62.3% of cases and could be related to a matching coronary finding in 84.9%. A total of 15.1% of peracute lesions on pmMRI lacked a matching coronary finding but presented with severe myocardial hypertrophy or cocaine intoxication facilitating a cardiac death without verifiable coronary stenosis. CONCLUSIONS: 3-T pmMRI visualizes chronic, subacute, and acute myocardial infarction in situ. In peracute infarction as a possible cause of sudden cardiac death, it demonstrates affected myocardial areas not visible on autopsy. pmMRI should be considered as a feasible post-mortem investigation technique for the deceased patient if no consent for a clinical autopsy is obtained.
Resumo:
The aim of this study was to investigate if acute myocardial infarction can be detected by post-mortem cardiac magnetic resonance (PMMR) at an earlier stage than by traditional autopsy, i.e., within less than 4 h after onset of ischemia; and if so, to determine the characteristics of PMMR findings in early acute infarcts. Twenty-one ex vivo porcine hearts with acute myocardial infarction underwent T2-weighted cardiac PMMR imaging within 3 h of onset of iatrogenic ischemia. PMMR imaging findings were compared to macroscopic findings. Myocardial edema induced by ischemia and reperfusion was visible on PMMR in all cases. Typical findings of early acute ischemic injury on PMMR consist of a central zone of intermediate signal intensity bordered by a rim of increased signal intensity. Myocardial edema can be detected on cardiac PMMR within the first 3 h after the onset of ischemia in porcine hearts. The size of myocardial edema reflects the area of ischemic injury in early acute (per-acute) myocardial infarction. This study provides evidence that cardiac PMMR is able to detect acute myocardial infarcts at an earlier stage than traditional autopsy and routine histology.
Resumo:
OBJECTIVE The aim of this work is to investigate and compare cardiac proton density (PD) weighted fast field echo (FFE) post-mortem magnetic resonance (PMMR) imaging with standard cardiac PMMR imaging (T1-weighted and T2-weighted turbo spin-echo (TSE)), postmortem CT (PMCT) as well as autopsy. MATERIALS AND METHODS Two human cadavers sequentially underwent cardiac PMCT and PMMR imaging (PD-weighted FFE, T1-weighted and T2-weighted TSE) and autopsy. The cardiac PMMR images were compared to each other as well as to PMCT and autopsy findings. RESULTS For the first case, cardiac PMMR exhibited a focal region of low signal in PD-weighted FFE and T2-weighted TSE images, surrounded by a signal intense rim in the T2-weighted images. T1-weighted TSE and PMCT did not appear to identify any focal abnormality. Macroscopic inspection identified a blood clot; histology confirmed this to be a thrombus with an adhering myocardial infarction. In the second case, a myocardial rupture with heart tamponade was identified in all PMMR images, located at the anterior wall of the left ventricle; PMCT excluded additional ruptures. In PD-weighted FFE and T2-weighted TSE images, it occurred hypo-intense, while resulting in small clustered hyper-intense spots in T1-weighted TSE. Autopsy confirmed the PMMR and PMCT findings. CONCLUSIONS Presented initial results have shown PD-weighted FFE to be a valuable imaging sequence in addition to traditional T2-weighted TSE imaging for blood clots and myocardial haemorrhage with clearer contrast between affected and healthy myocardium.
Resumo:
Sickle cell anemia (SCA) is a hemolytic disease characterized by the production of abnormal hemoglobin chains and distorted red blood cell morphology or sickling. "Sickle cell crisis" includes vaso-occlusive crisis, a plastic crisis, sequestration crisis, haemolytic crisis and often culminating in serious complications, organ damage and even sudden death. Post-mortem computed tomography (PMCT) findings of sickle cell disease have never been reported in literature. This case of sudden death from acute hemolytic crisis in SCA where post-mortem computed tomography (PMCT) and autopsy findings complemented each other, both revealing findings invisible to the other and both crucial to the case.
Resumo:
We present a case where multi-phase post-mortem computed tomography angiography (PMCTA) induced a hemorrhagic pericardial effusion during the venous phase of angiography. Post-mortem non-contrast CT (PMCT) suggested the presence of a ruptured aortic dissection. This diagnosis was confirmed by PMCTA after pressure controlled arterial injection of contrast. During the second phase of multi-phase PMCTA the presence of contrast leakage from the inferior cava vein into the pericardial sac was noted. Autopsy confirmed the post-mortem nature of this vascular tear. This case teaches us an important lesson: it underlines the necessity to critically analyze PMCT and PMCTA images in order to distinguish between artifacts, true pathologies and iatrogenic findings. In cases with ambiguous findings such as the case reported here, correlation of imaging findings with autopsy is elementary.
Resumo:
We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.
Resumo:
Introduction The aim of this study was to determine which single measurement on post-mortem cardiac MR reflects actual heart weight as measured at autopsy, assess the intra- and inter-observer reliability of MR measurements, derive a formula to predict heart weight from MR measurements and test the accuracy of the formula to prospectively predict heart weight. Materials and methods 53 human cadavers underwent post-mortem cardiac MR and forensic autopsy. In Phase 1, left ventricular area and wall thickness were measured on short axis and four chamber view images of 29 cases. All measurements were correlated to heart weight at autopsy using linear regression analysis. In Phase 2, single left ventricular area measurements on four chamber view images (LVA_4C) from 24 cases were used to predict heart weight at autopsy based on equations derived during Phase 1. Intra-class correlation coefficient (ICC) was used to determine inter- and intra-reader agreement. Results Heart weight strongly correlates with LVA_4C (r=0.78 M; p<0.001). Intra-reader and inter-reader reliability was excellent for LVA_4C (ICC=0.81–0.91; p<0.001 and ICC=0.90; p<0.001 respectively). A simplified formula for heart weight ([g]≈LVA_4C [mm2]×0.11) was derived based on linear regression analysis. Conclusions This study shows that single circumferential area measurements of the left ventricle in the four chamber view on post-mortem cardiac MR reflect actual heart weight as measured at autopsy. These measurements yield an excellent intra- and inter-reader reliability and can be used to predict heart weight prior to autopsy or to give a reasonable estimate of heart weight in cases where autopsy is not performed.
Resumo:
Post-mortem MR (PMMR) imaging is a powerful diagnostic tool with a wide scope in forensic radiology. In the past 20 years, PMMR has been used as both an adjunct and an alternative to autopsy. The role of PMMR in forensic death investigations largely depends on the rules and habits of local jurisdictions, availability of experts, financial resources, and individual case circumstances. PMMR images are affected by post-mortem changes, including position-dependent sedimentation, variable body temperature and decomposition. Investigators must be familiar with the appearance of normal findings on PMMR to distinguish them from disease or injury. Coronal whole-body images provide a comprehensive overview. Notably, short tau inversion–recovery (STIR) images enable investigators to screen for pathological fluid accumulation, to which we refer as “forensic sentinel sign”. If scan time is short, subsequent PMMR imaging may be focussed on regions with a positive forensic sentinel sign. PMMR offers excellent anatomical detail and is especially useful to visualize pathologies of the brain, heart, subcutaneous fat tissue and abdominal organs. PMMR may also be used to document skeletal injury. Cardiovascular imaging is a core area of PMMR imaging and growing evidence indicates that PMMR is able to detect ischaemic injury at an earlier stage than traditional autopsy and routine histology. The aim of this review is to present an overview of normal findings on forensic PMMR, provide general advice on the application of PMMR and summarise the current literature on PMMR imaging of the head and neck, cardiovascular system, abdomen and musculoskeletal system.
Resumo:
Gustav Friedrich Oehler
Resumo:
OBJECTIVE To investigate frequent findings in cases of fatal opioid intoxication in whole-body post-mortem computed tomography (PMCT). METHODS PMCT of 55 cases in which heroin and/or methadone had been found responsible for death were retrospectively evaluated (study group), and were compared with PMCT images of an age- and sex-matched control group. Imaging results were compared with conventional autopsy. RESULTS The most common findings in the study group were: pulmonary oedema (95 %), aspiration (66 %), distended urinary bladder (42 %), cerebral oedema (49 %), pulmonary emphysema (38 %) and fatty liver disease (36 %). These PMCT findings occurred significantly more often in the study group than in the control group (p < 0.05). The combination of lung oedema, brain oedema and distended urinary bladder was seen in 26 % of the cases in the study group but never in the control group (0 %). This triad, as indicator of opioid-related deaths, had a specificity of 100 %, as confirmed by autopsy and toxicological analysis. CONCLUSIONS Frequent findings in cases of fatal opioid intoxication were demonstrated. The triad of brain oedema, lung oedema and a distended urinary bladder on PMCT was highly specific for drug-associated cases of death. KEY POINTS Frequent findings in cases of fatal opioid intoxication were investigated. Lung oedema, brain oedema and full urinary bladder represent a highly specific constellation. This combination of findings in post-mortem CT should raise suspicion of intoxication.
What are the greatest challenges or barriers to applying post-mortem imaging in pediatric radiology?
Resumo:
Steamer accidents, through contact with the bucket wheel, are very seldom today. No publication of such a kind of fatal accident could be found in literature. We present the case of a fatal steamer accident, in which the findings of a blunt traumatization of a person by the ship was completely documented by post-mortem combined multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) examinations. A rupture of the aorta was detected using both radiological methods without use of radiopaque material. Radiological examination revealed a comminuted fracture of the thorax vertebrae at the same level as the aortic rupture. Injuries of the soft tissues of the back, caused by the bucket wheel of the steamer, were also diagnosed. In addition to the signs of blunt force trauma the findings of drowning such as an over inflation of the lungs, fluid in the stomach and duodenum were revealed. Furthermore, algological analysis detected diatoms in the lung tissue and blood from the left heart. Therefore, the cause of death was considered being a combination of fatal hemorrhage, caused by the aortic rupture, and drowning. We conclude that virtual autopsy using combined post-mortem MSCT and MRI is a useful tool for documentation, visualisation and analysis of the findings of blunt force trauma and drowning with a large potential in forensic medicine.