901 resultados para photoinduced refractive index changing spectrum


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The refractive index of ZnO/organic nanocomposite films was modified in the range from 1.44 to 1.55, while maintaining high visible transparency. The transparency of the nanocomposite films showed an abnormal behaviour as a function of the loading level of inorganic particles, because it did not decrease according to the Beer-Lambert law, but rather saturated to a near-constant value at high particle loading levels above 8 vol.-%. On the other hand, the refractive index of the film showed good agreement with the Bruggemann model, linearly increased as particle concentration increased. This result indicates the possibility of fabricating highly transparent nanocomposite films with controlled refractive indices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hybrid films consisting of ZnO nanoparticles and organic matrices were fabricated at particle concentration levels of up to 60 wt%. The correlation between the refractive index and optical transmittance in the visible light region was investigated. The refractive index of the hybrid films was modified in a continuous manner in the range from 1.44 to 1.55. The refractive index increased linearly as a function of particle concentration. On the other hand, optical transmittance showed little change above the particle volume fraction of 0.08.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlength that avoids the need to physically relocate the objective lens or the sample during an axial scan, and present an experimental realization based on an adaptive liquid-crystal lens. We present experimental results, including video clips, which demonstrate refractive index tomography of a range of turbid liquid phantoms, as well as of human skin in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The approach taken here of reconstruction of the refractive index profile of planar waveguides involves solving a non-linear integral equation with Tikhonov regularization. Using global optimization with the new cutting angle and discrete gradient methods has yielded an acceptable reconstruction, even in the presence of significant noise in the data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements.

Methods: A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means ± standard errors of the means are reported.

Results: In vivo RI values at baseline were 1.422 ± 0.0004 (lotrafilcon B) and 1.405 ± 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 ± 0.0006 and 1.408 ± 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 ± 0.0004 and 1.411 ± 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 ± 0.0003 (lotrafilcon B) and 1.412 ± 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05).

Conclusions: This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nonlinear refractive index, n(2), of films based on the new glass system Sb(2)O(3)-Sb(2)S(3) was measured at 1064 nm with laser pulses of 15 ps, using a single-beam nonlinear image technique in presence of a phase object. The films were prepared from bulk glasses by RF-sputtering. A large value of n(2) = 3 x 10-(15) m(2)/W, which is three orders of magnitude larger than for CS(2), was determined. The result shows the strong potential of antimony-sulfide glass films for integrated nonlinear optics. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The top faces of float glass samples were exposed to vapors resulting from the decomposition of KNO3 at 565 degrees C for up to 32 h. X-ray dispersive spectra (EDS) show that K+ ions migrate into the glass. The K+ concentration profile was obtained and its diffusion coefficient was calculated by the Boltzmann-Matano technique. The mean diffusion coefficient was approximately 10 X 10(-11) cm(2) s(-1). It was observed that the refractive index and the Vickers hardness decrease with the depth (after the removal of successive layers), and their profiles were thus obtained. These profiles enabled the calculation of the diffusion coefficient of K+ through the Boltzmann-Matano technique, with mean results ranging between 6 x 10(-11) and 30 x 10(-11) cm(2) s(-1). (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The formation of sulfated zirconia films from a sol-gel derived aqueous suspension is subjected to double-optical monitoring during batch dip coating. Interpretation of interferometric patterns, previously obscured by a variable refractive index, is now made possible by addition of its direct measurement by a polarimetric technique in real time. Significant sensitivity of the resulting physical thickness and refractive index curves (uncertainties of ±7 nm and ±0.005, respectively) to temporal film evolution is shown under different withdrawal speeds. As a first contribution to quantitative understanding of temporal film formation with varying nanostructure during dip coating, detailed analysis is directed to the stage of the process dominated by mass drainage, whose simple modeling with temporal t-1/2 dependence is verified experimentally. © 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Euphorbia tirucalli Lineu (Aveloz) belongs to the family Euphorbiaceae and is used in the treatment of cancer and warts. Some studies have reported that phorbol esters are the active principles responsible for the antitumor activity of Aveloz. The production of these molecules occurs in greater quantity in May, during the morning. This study aimed to evaluate whether the physico-chemical parameters of Aveloz homeopathic aqueous solutions such as pH, electrical conductivity and refractive index change due to storage time. Such parameters were measured regularly for 180 days. All solutions were prepared according to the method of grinding with lactose and subsequent dissolution in aqueous medium, as described in the Brazilian Homeopathic Pharmacopoeia, using as starting point the Aveloz latex collected in May. Homeopathic aqueous solutions containing only lactose were also prepared and evaluated as a control group. The potencies that were analyzed for electrical conductivity, pH and refractive index were: 4cH, 7cH, 9cH, 12cH, 14cH, 15cH, 29cH, 30cH. As a result, we found out that there was only statistical difference (p=0.035) in electrical conductivity between the homeopathic solutions containing Aveloz and the homeopathic solutions without Aveloz, when 15cH potency was compared. We also observed that the electrical conductivity increased with the aging of the solutions but is not directly related to the pH or the refractive index of the solutions, indicating that the aging process may alter the electrical conductivity of the homeopathic medicines. The presence of gas inside the glass that stores these solutions may affect the electrical conductivity measurements. Finally, no statistically significant difference was observed (p> 0.05) in the pH and refractive index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The photosensitivity of GeSx binary glasses in response to irradiation to femtosecond pulses at 800 nm is investigated. Samples with three different molecular compositions were irradiated under different exposure conditions. The material response to laser exposure was characterized by both refractometry and micro-Raman spectroscopy. It is shown that the relative content of sulfur in the glass matrix influences the photo-induced refractive index modification. At low sulfur content, both positive and negative index changes can be obtained while at high sulfur content, only a positive index change can be reached. These changes were correlated with variations in the Raman response of exposed glass which were interpreted in terms of structural modifications of the glass network. Under optimized exposure conditions, waveguides with positive index changes of up to 7.8x10−3 and a controllable diameter from 14 to 25 μm can be obtained. Direct inscription of low insertion losses (IL = 3.1 – 3.9 dB) waveguides is demonstrated in a sample characterized by a S/Ge ratio of 4. The current results open a pathway towards the use of Ge-S binary glasses for the fabrication of integrated mid-infrared photonic components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.