912 resultados para performance measurement system
Resumo:
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend-diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Resumo:
Non-uniformity of steps within a flight is a major risk factor for falls. Guidelines and requirements for uniformity of step risers and tread depths assume the measurement system provides precise dimensional values. The state-of-the-art measurement system is a relatively new method, known as the nosing-to-nosing method. It involves measuring the distance between the noses of adjacent steps and the angle formed with the horizontal. From these measurements, the effective riser height and tread depth are calculated. This study was undertaken for the purpose of evaluating the measurement system to determine how much of total measurement variability comes from the step variations versus that due to repeatability and reproducibility (R&R) associated with the measurers. Using an experimental design quality control professionals call a measurement system experiment, two measurers measured all steps in six randomly selected flights, and repeated the process on a subsequent day. After marking each step in a flight in three lateral places (left, center, and right), the measurers took their measurement. This process yielded 774 values of riser height and 672 values of tread depth. Results of applying the Gage R&R ANOVA procedure in Minitab software indicated that the R&R contribution to riser height variability was 1.42%; and to tread depth was 0.50%. All remaining variability was attributed to actual step-to-step differences. These results may be compared with guidelines used in the automobile industry for measurement systems that consider R&R less than 1% as an acceptable measurement system; and R&R between 1% and 9% as acceptable depending on the application, the cost of the measuring device, cost of repair, or other factors.
Resumo:
Aufgrund sich schnell verändernder Anforderungen des Marktes sind Unternehmen ständig dazu aufgefordert, ihre eigenen Prozesse und Strukturen zu überdenken und ggf. anzupassen. Von diesen Entwicklungen ist auch die Kommissionierung als Teil eines Intralogistiksystems betroffen. Um allerdings geeignete Maßnahmen ergreifen zu können, müssen Systemleistungen und –kosten permanent gemessen werden. Hierzu eignet sich der Einsatz von Performance Measurement-Systemen als Weiterentwicklung traditioneller Kennzahlensysteme. In diesem Beitrag werden verschiedene Performance Measurement-Systeme gegenüber gestellt und hinsichtlich ihrer Eignung für den Einsatz in Kommissioniersystemen bewertet. Auf Basis der Ergebnisse der Bewertung erfolgt eine erste Konzeption eines Performance Measurement-Systems für die Kommissionierung unter Verwendung typischer Kennzahlen, die in der Literatur genannt werden. Abschließend werden Hinweise zur noch notwendigen detaillierten Umsetzung und Evaluation in der Praxis gegeben.
Resumo:
Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1992
Wireless measurement system for structural health monitoring with high time synchronization accuracy
Resumo:
Structural health monitoring (SHM) systems have excellent potential to improve the regular operation and maintenance of structures. Wireless networks (WNs) have been used to avoid the high cost of traditional generic wired systems. The most important limitation of SHM wireless systems is time-synchronization accuracy, scalability, and reliability. A complete wireless system for structural identification under environmental load is designed, implemented, deployed, and tested on three different real bridges. Our contribution ranges from the hardware to the graphical front end. System goal is to avoid the main limitations of WNs for SHM particularly in regard to reliability, scalability, and synchronization. We reduce spatial jitter to 125 ns, far below the 120 μs required for high-precision acquisition systems and much better than the 10-μs current solutions, without adding complexity. The system is scalable to a large number of nodes to allow for dense sensor coverage of real-world structures, only limited by a compromise between measurement length and mandatory time to obtain the final result. The system addresses a myriad of problems encountered in a real deployment under difficult conditions, rather than a simulation or laboratory test bed.
Resumo:
The implementation of Internet technologies has led to e-Manufacturing technologies becoming more widely used and to the development of tools for compiling, transforming and synchronising manufacturing data through the Web. In this context, a potential area for development is the extension of virtual manufacturing to performance measurement (PM) processes, a critical area for decision making and implementing improvement actions in manufacturing. This paper proposes a PM information framework to integrate decision support systems in e-Manufacturing. Specifically, the proposed framework offers a homogeneous PM information exchange model that can be applied through decision support in e-Manufacturing environment. Its application improves the necessary interoperability in decision-making data processing tasks. It comprises three sub-systems: a data model, a PM information platform and PM-Web services architecture. A practical example of data exchange for measurement processes in the area of equipment maintenance is shown to demonstrate the utility of the model.
Resumo:
La présente thèse vise à évaluer le degré d’implantation et d’utilisation de systèmes de mesure de la performance (SMP) par les décideurs des organisations de réadaptation et à comprendre les facteurs contextuels ayant influencé leur implantation. Pour ce faire, une étude de cas multiples a été réalisée comprenant deux sources de données: des entrevues individuelles avec des cadres supérieurs des organisations de réadaptation du Québec et des documents organisationnels. Le cadre conceptuel Consolidated Framework for Implementation Research a été utilisé pour guider la collecte et l’analyse des données. Une analyse intra-cas ainsi qu’une analyse inter-cas ont été réalisées. Nos résultats montrent que le niveau de préparation organisationnelle à l’implantation d’un SMP était élevé et que les SMP ont été implantés avec succès et utilisés de plusieurs façons. Les organisations les ont utilisés de façon passive (comme outil d’information), de façon ciblée (pour tenter d’améliorer des domaines sous-performants) et de façon politique (comme outil de négociation auprès des autorités gouvernementales). Cette utilisation diversifiée des SMP est suscitée par l’interaction complexe de facteurs provenant du contexte interne propre à chaque organisation, des caractéristiques du SMP, du processus d’implantation appliqué et du contexte externe dans lequel évoluent ces organisations. Au niveau du contexte interne, l’engagement continu et le leadership de la haute direction ont été décisifs dans l’implantation du SMP de par leur influence sur l’identification du besoin d’un SMP, l’engagement des utilisateurs visés dans le projet, la priorité organisationnelle accordée au SMP ainsi que les ressources octroyées à son implantation, la qualité des communications et le climat d’apprentissage organisationnel. Toutefois, même si certains de ces facteurs, comme les ressources octroyées à l’implantation, la priorité organisationnelle du SMP et le climat d’apprentissage se sont révélés être des barrières à l’implantation, ultimement, ces barrières n’étaient pas suffisamment importantes pour entraver l’utilisation du SMP. Cette étude a également confirmé l’importance des caractéristiques du SMP, particulièrement la perception de qualité et d’utilité de l’information. Cependant, à elles seules, ces caractéristiques sont insuffisantes pour assurer le succès d’implantation. Cette analyse d’implantation a également révélé que, même si le processus d’implantation ne suit pas des étapes formelles, un plan de développement du SMP, la participation et l’engagement des décideurs ainsi que la désignation d’un responsable de projet ont tous facilité son implantation. Cependant, l’absence d’évaluation et de réflexion collective sur le processus d’implantation a limité le potentiel d’apprentissage organisationnel, un prérequis à l’amélioration de la performance. Quant au contexte externe, le soutien d’un organisme externe s’est avéré un facilitateur indispensable pour favoriser l’implantation de SMP par les organisations de réadaptation malgré l’absence de politiques et incitatifs gouvernementaux à cet effet. Cette étude contribue à accroître les connaissances sur les facteurs contextuels ainsi que sur leurs interactions dans l’utilisation d’innovations tels les SMP et confirme l’importance d’aborder l’analyse de l’implantation avec une perspective systémique.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
"June 1997."
Resumo:
Shipping list no.: 93-0182-P.