913 resultados para operational speed
Resumo:
The orthodoxy of supply chain management (SCM) emphasises competitive advantage through increased operational efficiency and market responsiveness from production and distribution processes into the hands of consumers. It anticipates that future competition will be between chains rather than between firms. While well established in other industry sectors, the SCM concept is newly developed in the Australian agri-food sector. Critical review of the concept has identified key issues of power among channel members, processes of chain initiation and innovation, and the inability of SCM to offer a viable business strategy for some firms. Building on those insights, this paper examines the supply chain concept for horticulture. Horticultural products are characterised by perishability, heterogeneity and lags in production response to market signals. Producers’ profits are vulnerable to quantity, timing of supply and product specification. Many supply chains in smaller industries are loose, fragmented, interwoven, unstable and unique! Firms operating within these environments need an astute understanding of the chains, the hierarchy of channel members and their relative position. Effective business strategies – for individual firms and supply chains - need to be developed and redeveloped to accommodate the dynamic nature of horticulture. Two case studies are discussed as contributions to this early stage of the theoretical development of supply chain management. The SCM concept also has implications for horticultural researchers, involving a wider range of industry stakeholders, technical problems and research skills. As for business management, the usefulness of the concept will depend on its capacity to increase responsiveness to customers’ preferences and customer value.
Resumo:
We conducted a review to establish the range and scope of current telemedicine guidelines and standards. Published guidelines were identified by searching the Medline and Telemedicine Information Exchange (TIE) databases, and by performing a Google search using the term 'telemedicine guidelines'. Three types of guidelines were identified, namely clinical, operational and technical. Clinical guidelines included those for teleradiology, telepsychiatry, home telenursing, minor injuries telemedicine, surgical telemedicine, teledermatology and telepathology. Operational guidelines included those for email communication, Internet access and videoconferencing. Technical guidelines included those from the American Telemedicine Association and the US Office for the Advancement of Telehealth. The main standards relevant to telemedicine include those of the International Telecommunication Union and the DICOM standard. The scarcity of guidelines and standards suggests that telemedicine is not yet near to routine use. If an international telemedicine organization were to take responsibility for defining guidelines, under the direction of clinicians with appropriate telemedicine experience, this might speed up their development.
Resumo:
In 1995, the Queensland Parks and Wildlife Service, the Queensland Department of Main Roads and Redland Shire Council initiated the Koala Speed Zone Trial in the Koala Coast, south-east Queensland. The aim of the trial was to assess the effect of differential speed signs on the number of koalas ( Phascolarctos cinereus) hit by vehicles in the Koala Coast from 1995 to 1999. On the basis of information collected by the Queensland Parks and Wildlife Service 1407 koalas were hit by vehicles in the Koala Coast during the five-year study ( mean 281 koalas per year, range 251 - 315). Monitoring of vehicle speeds by the Queensland Department of Main Roads suggested that there was no significant reduction in vehicle speed during the trial period from August to December. Consequently, there was no evidence to suggest that a reduction in the number of koalas hit by vehicles occurred during the trial. Approximately 70% of koalas were hit on arterial and sub-arterial roads and approximately 83% did not survive. The location of each koala hit was recorded and the signed speed limit of the road was noted. Most koalas that were hit by vehicles were young healthy males. Pooling of data on koala collisions and road speed limits suggested that the proportion of koalas that survived being hit by vehicles was slightly higher on roads with lower speed limits. However, vehicle speed was not the only factor that affected the number of koalas hit by vehicles. It is suggested that habitat destruction, koala density and traffic volume also contribute to road-associated koala mortality in the Koala Coast.
Resumo:
The aim of this study was to compare the effects of two high-intensity, treadmill interval-training programs on 3000-m and 5000-m running performance. Maximal oxygen uptake ((V) over dot O-2max), the running speed associated with (V) over dot O-2max (nu (V) over dot O-2max), the time for which nu (V) over dot O-2max can be maintained (T-max), running economy (RE), ventilatory threshold (VT) and 3000-m and 5000-m running times were determined in 27 well-trained runners. Subjects were then randomly assigned to three groups; (1) 60% T-max (2) 70% T-max and (3) control. Subjects in the control group continued their normal training and subjects in the two T-max groups undertook a 4-week treadmill interval-training program with the intensity set at nu (V) over dot O-2max and the interval duration at the assigned T-max. These subjects completed two interval-training sessions per week (60% T-max = six intervals/session, 70% T-max group = five intervals/session). Subjects were re-tested on all parameters at the completion of the training program. There was a significant improvement between pre- and post-training values in 3000-m time trial (TT) performance in the 60% T-max group compared to the 70% T,,a, and control groups [mean (SE); 60% T-max = 17.6 (3.5) s, 70% T-max = 6.3 (4.2) s, control = 0.5 (7.7) s]. There was no significant effect of the training program on 5000-m TT performance [60% T-max = 25.8 (13.8) s, 70% T-max = 3.7 (11.6) s, control = 9.9 (13.1) s]. Although there were no significant improvements in (V) over dot O-2max, nu (V) over dot (2max) and RE between groups, changes in (V) over dot O-2max and RE were significantly correlated with the improvement in the 3000-m TT. Furthermore, VT and T-max were significantly higher in the 60% Tmax group post-compared to pre-training. In conclusion, 3000-m running performance can be significantly improved in a group of well-trained runners, using a 4-week treadmill interval training program at nu (V) over dot O-2max with interval durations of 60% T-max.
Resumo:
Several antineoplasic drugs have been demonstrated to be carcinogenic or to have mutagenic and teratogenic effects. The greatest protection is achieved with the implementation of administrative and engineering controls and safety procedures. Objective: to evaluate the improvements on pharmacy technicians' work practices, after the implementation of operational procedures related to individual protection, biologic safety cabinet disinfection and cytotoxic drug preparation. Method: case-study in a hospital pharmacy undergoing a certification process. Six pharmacy technicians were observed during their daily activities. Characterization of the work practices was made using a checklist based on ISOPP and PIC guidelines. The variables studied concerning cleaning/disinfection procedures, personal protective equipment and procedures for preparing cytotoxic drugs. The same work practices were evaluated after four months of operational procedures implementation. Concordance between work practices and guidelines was considered to be a quality indicator (guidelines concordance practices number/total number of practices x 100). Results: improvements were observed after operational procedures implementation. An improvement of 6,25% in personal protective equipment practice was achieved by changing second pair of gloves every thirty minutes. The major progress, 10%, was obtained in disinfection procedure, where 80% of tasks are now realized according to guidelines.By now, we hot an improvement of only 1% at drug preparation procedure by placing one cytotoxic drug at a time inside the biological safety cabinet. Then, 85% of practices are according to guidelines. Conclusion: before operational procedures implementation 80,3% of practices were according to the guidelines, while now is 84,4%. This indicates that is necessary to review the procedures frequently in the benefit to reduce the risks associated with handling cytotoxic drugs and maintenance of drug specifications.
Resumo:
This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A method to control the speed or the torque of a permanent-magnet direct current motor is presented. The rotor speed and the external torque estimation are simultaneously provided by appropriate observers. The sensorless control scheme is based on current measurement and switching states of power devices. The observer’s performances are dependent on the accurate machine parameters knowledge. Sliding mode control approach was adopted for drive control, providing the suitable switching states to the chopper power devices. Despite the predictable chattering, a convenient first order switching function was considered enough to define the sliding surface and to correspond with the desired control specifications and drive performance. The experimental implementation was supported on a single dsPIC and the controller includes a logic overcurrent protection.
Resumo:
The top velocity of high-speed trains is generally limited by the ability to supply the proper amount of energy through the pantograph-catenary interface. The deterioration of this interaction can lead to the loss of contact, which interrupts the energy supply and originates arcing between the pantograph and the catenary, or to excessive contact forces that promote wear between the contacting elements. Another important issue is assessing on how the front pantograph influences the dynamic performance of the rear one in trainsets with two pantographs. In this work, the track and environmental conditions influence on the pantograph-catenary is addressed, with particular emphasis in the multiple pantograph operations. These studies are performed for high speed trains running at 300 km/h with relation to the separation between pantographs. Such studies contribute to identify the service conditions and the external factors influencing the contact quality on the overhead system. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
This paper reports a novel application of microwave-assisted extraction (MAE) of polyphenols from brewer’s spent grains (BSG). A 24 orthogonal composite design was used to obtain the optimal conditions of MAE. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the extraction yield of ferulic acid was investigated through response surface methodology. The results showed that the optimal conditions were 15 min extraction time, 100 °C extraction temperature, 20 mL of solvent, and maximum stirring speed. Under these conditions, the yield of ferulic acid was 1.31±0.04% (w/w), which was fivefold higher than that obtained with conventional solid–liquid extraction techniques. The developed new extraction method considerably reduces extraction time, energy and solvent consumption, while generating fewer wastes. HPLC-DADMS analysis indicated that other hydroxycinnamic acids and several ferulic acid dehydrodimers, as well as one dehydrotrimer were also present, confirming that BSG is a valuable source of antioxidant compounds.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
Microwave-assisted extraction (MAE) of agar from Gracilaria vermiculophylla, produced in an integrated multitrophic aquaculture (IMTA) system, from Ria de Aveiro (northwestern Portugal), was tested and optimized using response surface methodology. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the physical and chemical properties of agar (yield, gel strength, gelling and melting temperatures, as well as, sulphate and 3,6-anhydro-Lgalactose contents) was evaluated in a 2^4 orthogonal composite design. The quality of the extracted agar compared favorably with the attained using traditional extraction (2 h at 85ºC) while reducing drastically extraction time, solvent consumption and waste disposal requirements. Agar MAE optimum results were: an yield of 14.4 ± 0.4%, a gel strength of 1331 ± 51 g/cm2, 40.7 ± 0.2 _C gelling temperature, 93.1 ± 0.5ºC melting temperature, 1.73 ± 0.13% sulfate content and 39.4 ± 0.3% 3,6-anhydro-L-galactose content. Furthermore, this study suggests the feasibility of the exploitation of G. vermiculophylla grew in IMTA systems for agar production.
Resumo:
A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.