950 resultados para office buildings
Resumo:
Double Skin Façades (DSFs) are becoming increasingly popular architecture for commercial office buildings. Although DSFs are widely accepted to have the capacity to offer significant passive benefits and enable low energy building performance, there remains a paucity of knowledge with regard to their operation. Identification of the most determinant architectural parameters of DSFs is the focus of ongoing research. This paper presents an experimental and simulation study of a DSF installed on a commercial building in Dublin, Ireland. The DSF is south facing and acts to buffer the building from winter heat losses, but risks enhancing over-heating on sunny days. The façade is extensively monitored during winter months. Computational Fluid Dynamic (CFD) models are used to simulate the convective operation of the DSF. This research concludes DSFs as suited for passive, low energy architecture in temperature climates such as Ireland but identifies issues requiring attention in DSF design.
Resumo:
Glazed Double Skin Facades (DSF) offer the potential to improve the performance of all-glass building skins, common to commercial office buildings in which full facade glazing has almost become the standard. Single skin glazing results in increased heating and cooling costs over opaque walls, due to lower thermal resistance of glass, and the increased impact of solar gain through it. However, the performance benefit of DSF technology continues to be questioned and its operation poorly understood, particularly the nature of airflow through the cavity. This paper deals specifically with the experimental analysis of the air flow characteristics in an automated double skin façade. The benefit of the DSF as a thermal buffer, and to limit overheating is evaluated through analysis of an extensive set of parameters including air and surface temperatures at each level in the DSF, airflow readings in the cavity and at the inlet and outlet, solar and wind data, and analytically derived pressure differentials. The temperature and air-flow are monitored in the cavity of a DSF using wireless sensors and hot wire anemometers respectively. Automated louvre operation and building set-points are monitored via the BMS. Thermal stratification and air flow variation during changing weather conditions are shown to effect the performance of the DSF considerably and hence the energy performance of the building. The relative pressure effects due to buoyancy and wind are analysed and quantified. This research aims to developed and validate models of DSFs in the maritime climate, using multi-season data from experimental monitoring. This extensive experimental study provides data for training and validation of models.
Resumo:
Dissertação de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações
Resumo:
A forte preocupação ambiental, nomeadamente a emissão de Gases com Efeito de Estufa (GEE), aliada à constante ameaça do esgotamento dos combustíveis de origem fóssil, leva à necessidade de consumir energia de forma mais eficiente. Neste sentido, surge a promoção da eficiência energética nos diversos sectores consumidores de energia em todo o Mundo. Sabendo que passamos mais de 80% do nosso tempo dentro de edifícios, e que cerca de 40% da energia mundial é consumida nos mesmos [ADENE], é importante operar no sentido de promover a utilização racional de energia e incentivar ao consumo eficiente da mesma nos edifícios. Apesar do esforço que tem sido realizado a nível nacional, no sentido de melhorar a eficiência energética em edifícios de serviços, através da implementação de legislação diversa e de vários programas de incentivo, existem ainda várias lacunas a serem colmatadas e muito trabalho a fazer nesse sentido. Por tudo isto, e principalmente por ter constantemente em mente premissas como “a energia mais barata é aquela que não se consome” ou “não podemos gerir aquilo que não medimos”, surgiu a ideia de realizar esta dissertação, onde inicialmente através de dados provenientes de telecontagem se desenvolve uma tentativa de padronização/tipificação do consumo eléctrico em seis edifícios de escritórios, identificando-se assim algumas situações anómalas em diversos diagramas de carga construídos. Relaciona-se também o consumo eléctrico dos seis edifícios com algumas variáveis exógenas, de modo a perceber a influência das mesmas no consumo eléctrico de cada edifício. Numa vertente mais prática, foram identificadas e quantificadas potenciais medidas de melhoria, comportamentais e técnicas, num dos edifícios em estudo, de modo a poder contribuir para a redução do consumo energético do mesmo. Espera-se que este trabalho, possa eventualmente constituir uma ajuda na caracterização de consumos e detecção de medidas de melhoria em edifícios de escritórios, alcançando a eficiência energética neste tipo de instalações e facilitando assim o trabalho de vários profissionais do sector. Pretende-se igualmente demonstrar a importância da eficiência energética na gestão do uso da energia eléctrica em edifícios, e efectuar um paralelo entre a energia economizada por meio da implementação de medidas/acções de uso racional e eficiente, com a redução da queima de combustíveis fosseis na geração de energia eléctrica e a sua consequente redução nas emissões de dióxido de carbono (CO2), com o objectivo final de melhorar a qualidade de vida no nosso planeta.
Resumo:
Na União Europeia os sectores dos transportes e da indústria são ambos grandes consumidores de energia, mas são os edifícios residenciais e de serviços onde o consumo energético é maior, e em 2005, segundo a EnerBuilding, representavam cerca de 17% dos consumos de energia primária em termos nacionais. A energia gasta com a iluminação, o aquecimento, o arrefecimento e AQS das habitações, locais de trabalho e locais de lazer é superior à consumida pelos sectores dos transportes e da indústria. As habitações representam dois terços do consumo total de energia dos edifícios europeus, o qual aumenta todos os anos com a melhoria da qualidade de vida, traduzindo-se numa maior utilização dos sistemas de climatização. Neste sentido, e de acordo com o decreto-lei que transpõe para a legislação portuguesa a diretiva comunitária relativa ao desempenho energético dos edifícios, todos os Estados da União Europeia devem ter um sistema de certificação energética para informar o cidadão sobre a qualidade térmica dos edifícios, aquando da construção, da venda ou do arrendamento. Assim, entrou em vigor em Portugal, desde 1 de Janeiro de 2009, a obrigatoriedade de apresentação de um certificado de eficiência energética, no ato de compra, venda ou aluguer de edifícios novos e existentes. A certificação energética permite assim aos futuros utilizadores dos edifícios obter informação sobre os potenciais consumos de energia, no caso dos novos edifícios ou no caso de edifícios existentes sujeitos a grandes intervenções de reabilitação, dos seus consumos reais ou aferidos para padrões de utilização típicos, passando o consumo energético a integrar um conjunto dos aspetos importantes para a caracterização de qualquer edifício. Em edifícios de serviços, o certificado energético assegura aos utentes do edifício ou da fração que este reúne condições para garantir a eficiência energética e a adequada qualidade do ar interior. Uma vez que passamos 80% do nosso tempo em edifícios, e que isto se reflete num consumo cada vez mais elevado do sector residencial e dos serviços no consumo total energético do país, este trabalho pretende fazer a comparação dos vários equipamentos de aquecimento, de arrefecimento e de AQS e qual a influência dos mesmos na certificação energética de edifícios, e consequentemente na eficiência dos mesmos, sendo que a eficiência e a certificação energética de um edifício deve ser um aspeto relevante a levar em consideração no momento do planeamento ou da construção, bem como na aquisição de uma nova habitação. Um projeto concebido de modo a tirar proveito das condições climáticas, da orientação solar, dos ventos dominantes e utilizadas técnicas construtivas e os materiais adequados, é possível reduzir os gastos energéticos com a iluminação ou os sistemas de climatização.
Resumo:
Concerning improvements to the State Capitol Grounds including placement of the Allison memorial and Soldiers and Sailor's momuments; removal of heating plant and relieving the state of coal, ashes, gas and smoke; provision of office space to the Adjutant General; an eventual executive mansion; provision of office buildings; and for a Supreme Court building where together with its library auxiliaries will have perpetual growth and constant accessbility; and propose restoration of natural scenic value of the capitol site.
Resumo:
Ein Luft-Erdwärmetauscher (L-EWT) kommt wegen seines niedrigen Energiebedarfs und möglicher guter Aufwandszahlen als umweltfreundliche Versorgungskomponente für Gebäude in Betracht. Dabei ist besonders vorteilhaft, dass ein L-EWT die Umgebungsluft je nach Jahreszeit vorwärmen oder auch kühlen kann. Dem zufolge sind L-EWT zur Energieeinsparung nicht nur für den Wohnhausbau interessant, sondern auch dort, wo immer noch große Mengen an fossiler Energie für die Raumkühlung benötigt werden, im Büro- und Produktionsgebäudesektor. Der Einsatzbereich eines L-EWT liegt zwischen Volumenströmen von 100 m3/h und mehreren 100.000 m3/h. Aus dieser Bandbreite und den instationären Randbedingungen entstehen erhebliche Schwierigkeiten, allgemeingültige Aussagen über das zu erwartende thermische Systemverhalten aus der Vielzahl möglicher Konstruktionsvarianten zu treffen. Hauptziel dieser Arbeit ist es, auf Basis umfangreicher, mehrjähriger Messungen an einer eigens konzipierten Testanlage und eines speziell angepassten numerischen Rechenmodells, Kennzahlen zu entwickeln, die es ermöglichen, die Betriebseigenschaften eines L-EWT im Planungsalltag zu bestimmen und ein technisch, ökologisch wie ökonomisch effizientes System zu identifizieren. Es werden die Kennzahlen elewt (Aufwandszahl), QV (Netto-Volumenleistung), ME (Meterertrag), sowie die Kombination aus v (Strömungsgeschwindigkeit) und VL (Metervolumenstrom) definiert, die zu wichtigen Informationen führen, mit denen die Qualität von Systemvarianten in der Planungsphase bewertet werden können. Weiterführende Erkenntnisse über die genauere Abschätzung von Bodenkennwerten werden dargestellt. Die hygienische Situation der durch den L-EWT transportierten Luft wird für die warme Jahreszeit, aufgrund auftretender Tauwasserbildung, beschrieben. Aus diesem Grund werden alle relevanten lufthygienischen Parameter in mehreren aufwendigen Messkampagnen erfasst und auf pathogene Wirkungen überprüft. Es wird über Sensitivitätsanalysen gezeigt, welche Fehler bei Annahme falscher Randbedingungen eintreten. Weiterhin werden in dieser Arbeit wesentliche, grundsätzliche Erkenntnisse aufbereitet, die sich aus der Betriebsbeobachtung und der Auswertung der umfangreich vorliegenden Messdaten mehrerer Anlagen ergeben haben und für die praktische Umsetzung und die Betriebsführung bedeutend sind. Hinweise zu Materialeigenschaften und zur Systemwirtschaftlichkeit sind detailliert aufgeführt.
Resumo:
In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.
Resumo:
This paper investigates the extent to which office activity contributes to travel-related CO2 emission. Using ‘end-user’ figures[1], travel accounts for 32% of UK CO2 emission (Commission for Integrated Transport, 2007) and commuting and business travel accounts for a fifth of transport-related CO2 emissions, equating to 6.4% of total UK emissions (Building Research Establishment, 2000). Figures from the Department for Transport (2006) report that 70% of commuting trips were made by car, accounting for 73% of all commuting miles travelled. In assessing the environmental performance of an office building, the paper questions whether commuting and business travel-related CO2 emission is being properly assessed. For example, are office buildings in locations that are easily accessible by public transport being sufficiently rewarded? The de facto method for assessing the environmental performance of office buildings in the UK is the Building Research Establishment’s Environmental Assessment Method (BREEAM). Using data for Bristol, this paper examines firstly whether BREEAM places sufficient weight on travel-related CO2 emission in comparison with building operation-related CO2 emission, and secondly whether the methodology for assigning credits for travel-related CO2 emission efficiency is capable of discerning intra-urban differences in location such as city centre and out-of-town. The results show that, despite CO2 emission per worker from building operation and travel being comparable, there is a substantial difference in the credit-weighting allocated to each. Under the current version of BREEAM for offices, only a maximum of 4% of the available credits can be awarded for ensuring the office location is environmentally sustainable. The results also show that all locations within the established city centre of Bristol will receive maximum BREEAM credits. Given the parameters of the test there is little to distinguish one city centre location from another and out of town only one office location receives any credits. It would appear from these results that the assessment method is not able to discern subtle differences in the sustainability of office locations
Resumo:
reign real estate capital was a major source of financing domestic property market office construction in Central Europe after the fall of the Berlin Wall in 1989. During the 1990s, over 800 office buildings were either newly constructed or refurbished in Budapest, Prague and Warsaw. The primary focus of this analysis is explaining the spatial construction and redevelopment patterns of the post-1989 office buildings in these cities. Secondarily, we analyze the correlation of foreign direct investment flows to annual construction of office buildings. We seek to explain the location of new or refurbished office buildings in the central business district (CBD) or in non-CBD locations in terms of the effect of time, size of property and other variables, and test whether there is a positive correlation relationship of foreign direct investment flows and new office construction or refurbishment. Integrating relevant foreign direct investment (FDI), economic geography and property theories in the research, the authors attempt to bridge existing gaps in the literature.
Resumo:
This paper investigates whether obtaining sustainable building certification entails a rental premium for commercial office buildings and tracks its development over time. To this aim, both a difference-in-differences and a fixed-effects model approach are applied to a large panel dataset of office buildings in the United States in the 2000–2010 period. The results indicate a significant rental premium for both ENERGY STAR and LEED certified buildings. Controlling for confounding factors, this premium is shown to have increased steadily from 2006 to 2008, followed by a moderate decline in the subsequent periods. The results also show a significant positive relationship between ENERGY STAR labeling and building occupancy rates.
Resumo:
This research is a preliminary study which examines the impact of connectivity on value in the managed office and conventional office sectors. The research is based on an extensive literature review, online survey and case studies carried out during 2005. The research shows, for the first time in the UK, how connectivity can increase value in office buildings, and how technology is priced in the market place.
Resumo:
Purpose – Corporate Occupiers require offices and services which meet their business needs, whilst landlords must attract and retain occupiers in order to maximise occupancy and rental income. The purpose of this research is to help landlords and corporate occupiers understand each other better, in order to achieve a mutually beneficial relationship. Design/methodology/approach - This paper analyses interviews with 1334 office tenants in the UK, conducted over an 11-year period, to investigate determinants of occupier satisfaction, loyalty and advocacy. Structural equation modelling and regressions are performed using respondents’ ratings of satisfaction with many aspects of occupancy as explanatory variables. The dependent variables include satisfaction with property management, value for money, overall occupier satisfaction, lease renewal intentions and occupiers’ willingness to recommend their landlord. Findings - The aspects with most impact on occupiers’ satisfaction are the office building itself, its location and amenities, and also communication with their property manager, a belief that their business needs are understood and the property manager’s responsiveness to occupiers’ requests. Occupiers’ loyalty depends mainly upon feeling that their rent and service charges provide value for money, an amicable leasing process, the professionalism of their property manager and the Corporate Social Responsibility of the Landlord. ‘Empathy’ is crucial to occupiers’ willingness to recommend their landlord, and clear documentation and efficient legal process improve occupiers’ perception of receiving ‘Value for Money’. Research Limitations - The sample is skewed towards occupiers of prime office buildings in the UK, owned by landlords who care sufficiently about their tenants to commission studies into occupier satisfaction. Practical implications - This research should help to improve the landlord – tenant relationship, benefitting the businesses that rent property and helping building managers understand where to focus their efforts to achieve maximum effect on occupier satisfaction, loyalty and advocacy. Originality/value - There has been little academic research into the determinants of satisfaction of occupiers of UK commercial property. This large-scale study enables the most influential factors to be identified and prioritised.
Resumo:
The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.
Resumo:
PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: