975 resultados para non-triangular setup times


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine the frequency of coronary artery disease, microalbuminuria and the relation to lipid profile disorders, blood pressure and clinical and metabolic features. METHODS: Fifty-five type 2 diabetic patients (32 females, 23 males), aged 59.9±9 years and with known diabetes duration of 11±7.3 years were studied. Coronary artery disease (CAD) was defined as a positive history of myocardial infarction, typical angina, myocardial revascularization or a positive stress testing. Microalbuminuria was defined when two out of three overnight urine samples had a urinary albumin excretion ranging 20 - 200µg/min. RESULTS: CAD was present in 24 patients (43,6%). High blood pressure (HBP) present in 32 patients (58.2%) and was more frequent in CAD group (p=0.05) HBP. Increased the risk of CAD 3.7 times (CI[1.14-12]). Microalbuminuria was present in 25 patients (45.5%) and tended to associate with higher systolic blood pressure (SBP) (p = 0.06), presence of hypertension (p = 0.06) and know diabetes duration (p = 0.08). In the stepwise multiple logistic regression the systolic blood pressure was the only variable that influenced UAE (r = 0.39, r² = 0.14, p = 0.01). The h ypertensive patients had higher cholesterol levels (p = 0.04). CONCLUSION: In our sample the frequency of microalbuminuria, hypertension, hypercholesterolemia and CHD was high. Since diabetes is an independent risk factor for cardiovascular disease, the association of others risk factors suggest the need for an intensive therapeutic intervention in primary and in secundary prevention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevalence of obesity is increasing throughout the workforce. Manual lifting tasks are common and can produce significant muscle loading. This study compared muscular activity between obese and non-obese subjects, using surface Electromyography (EMG), during manual lifting. Six different lifting tasks (with 5, 10 and 15 kg loads in free and constrained styles) were performed by 14 participants with different obesity levels. EMG data normalization was based on the percentage of Maximum Contraction during each Task (MCT). Muscle Activation Times (AT) before each task were also evaluated. The study suggests that obesity can increase MCT and delay muscle AT. These findings reinforce the need to develop further studies focused on obesity as a risk factor for the development of musculoskeletal disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This note describes ParallelKnoppix, a bootable CD that allows econometricians with average knowledge of computers to create and begin using a high performance computing cluster for parallel computing in very little time. The computers used may be heterogeneous machines, and clusters of up to 200 nodes are supported. When the cluster is shut down, all machines are in their original state, so their temporary use in the cluster does not interfere with their normal uses. An example shows how a Monte Carlo study of a bootstrap test procedure may be done in parallel. Using a cluster of 20 nodes, the example runs approximately 20 times faster than it does on a single computer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carcinoembryonic antigen (CEA), immunologically identical to CEA derived from colonic carcinoma, was identified and purified from perchloric acid (PCA) extracts of bronchial and mammary carcinoma. CEA extracted from bronchial and mammary carcinoma was quantitated by single radial immunodiffusion and was found to be in average about 50-75 times less abundant in these tumors than in colonic carcinoma. CEA could also be detected in one normal breast in lactation and at lower concentrations in normal lung (1000-4000 times lower than in colonic carcinoma). The small amounts of CEA present in normal tissues are distinct from the glycoprotein of small mol. wt showing only partial identity with CEA, that we recently identified and extracted in much larger quantities from normal lung and spleen. The demonstration of the presence of CEA in non digestive carcinoma by classical gel precipitation analysis suggests that the CEA detected in the plasma of such patients by radioimmunoassay is also identical to colonic carcinoma CEA. Our comparative study of plasma CEA from bronchial and colonic carcinoma, showing that CEA from both types of patient has the same elution pattern on Sephadex G-200 and gives parallel inhibition curves in the radioimmunoassay, is in favor of this hypothesis. However, it should not be concluded that all positive CEA radioimmunoassay indicate the presence of an antigen identical to colonic carcinoma CEA. A word of warning concerning the interpretation of radioimmunoassay is required by the observation that the addition of mg amounts of PCA extract of normal plasma, cleared of CEA by Sephadex filtration, could interfere in the test and mimic the presence of CEA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We tested experimentally the effects of the presence of non-susceptible hosts on the infection with Trypanosoma cruzi of the vector Triatoma infestans. The experiment consisted in two treatments: with chickens, including two chickens (non-susceptible hosts) and two infected guinea pigs (susceptible hosts), and without chickens, including only two infected guinea pigs. The hosts were held unrestrained in individual metal cages inside a closed tulle chamber. A total of 200 uninfected T. infestans third instar nymphs were liberated in each replica, collected on day 14, and examined for infection and blood meal sources on day 32-36. The additional presence of chickens relative to infected guinea pigs: (a) significantly modified the spatial distribution of bugs; (b) increased significantly the likelihoods of having a detectable blood meal on any host and molting to the next instar; (c) did not affect the bugs' probability of death by predation; and (d) decreased significantly the overall percentage of T. infestans infected with T. cruzi. The bugs collected from inside or close to the guinea pigs' cages showed a higher infection rate (71-88%) than those collected from the chickens' cages (22-32%). Mixed blood meals on chickens and guinea pigs were detected in 12-21% of bugs. Although the presence of chickens would decrease the overall percentage of infected bugs in short term experiments, the high rate of host change of T. infestans would make this difference fade out if longer exposure times had been provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The comparison of complete genomes has revealed surprisingly large numbers of conserved non-protein-coding (CNC) DNA regions. However, the biological function of CNC remains elusive. CNC differ in two aspects from conserved protein-coding regions. They are not conserved across phylum boundaries, and they do not contain readily detectable sub-domains. Here we characterize the persistence length and time of CNC and conserved protein-coding regions in the vertebrate and insect lineages. RESULTS: The persistence length is the length of a genome region over which a certain level of sequence identity is consistently maintained. The persistence time is the evolutionary period during which a conserved region evolves under the same selective constraints.Our main findings are: (i) Insect genomes contain 1.60 times less conserved information than vertebrates; (ii) Vertebrate CNC have a higher persistence length than conserved coding regions or insect CNC; (iii) CNC have shorter persistence times as compared to conserved coding regions in both lineages. CONCLUSION: Higher persistence length of vertebrate CNC indicates that the conserved information in vertebrates and insects is organized in functional elements of different lengths. These findings might be related to the higher morphological complexity of vertebrates and give clues about the structure of active CNC elements.Shorter persistence time might explain the previously puzzling observations of highly conserved CNC within each phylum, and of a lack of conservation between phyla. It suggests that CNC divergence might be a key factor in vertebrate evolution. Further evolutionary studies will help to relate individual CNC to specific developmental processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present and validate BlastR, a method for efficiently and accurately searching non-coding RNAs. Our approach relies on the comparison of di-nucleotides using BlosumR, a new log-odd substitution matrix. In order to use BlosumR for comparison, we recoded RNA sequences into protein-like sequences. We then showed that BlosumR can be used along with the BlastP algorithm in order to search non-coding RNA sequences. Using Rfam as a gold standard, we benchmarked this approach and show BlastR to be more sensitive than BlastN. We also show that BlastR is both faster and more sensitive than BlastP used with a single nucleotide log-odd substitution matrix. BlastR, when used in combination with WU-BlastP, is about 5% more accurate than WU-BlastN and about 50 times slower. The approach shown here is equally effective when combined with the NCBI-Blast package. The software is an open source freeware available from www.tcoffee.org/blastr.html.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To retrospectively assess the influence of prophylactic cranial irradiation (PCI) timing on brain relapse rates in patients treated with two different chemoradiotherapy (CRT) regimens for Stage IIIB non-small-cell lung cancer (NSCLC). METHODS AND MATERIALS: A cohort of 134 patients, with Stage IIIB NSCLC in recursive partitioning analysis Group 1, was treated with PCI (30 Gy at 2 Gy/fr) following one of two CRT regimens. Regimen 1 (n = 58) consisted of three cycles of induction chemotherapy (ICT) followed by concurrent CRT (C-CRT). Regimen 2 (n = 76) consisted of immediate C-CRT during thoracic radiotherapy. RESULTS: At a median follow-up of 27.6 months (range, 7.2-40.4), 65 patients were alive. Median, progression-free, and brain metastasis-free survival (BMFS) times for the whole study cohort were 23.4, 15.4, and 23.0 months, respectively. Median survival time and the 3-year survival rate for regimens 1 and 2 were 19.3 vs. 26.1 months (p = 0.001) and 14.4% vs. 34.4% (p < .001), respectively. Median time from the initiation of primary treatment to PCI was 123.2 (range, 97-161) and 63.4 (range, 55-74) days for regimens 1 and 2, respectively (p < 0.001). Overall, 11 (8.2%) patients developed brain metastasis (BM) during the follow-up period: 8 (13.8%) in regimen 1 and 3 (3.9%) in regimen 2 (p = 0.03). Only 3 (2.2%) patients developed BM at the site of first failure, and for 2 of them, it was also the sole site of recurrence. Median BMFS for regimens 1 and 2 were 17.4 (13.5-21.3) vs. 26.0 (22.9-29.1 months), respectively (p < 0.001). CONCLUSION: These results suggest that in Stage IIIB NSCLC patients treated with PCI, lower BM incidence and longer survival rates result from immediate C-CRT rather than ITC-first regimens. This indicates the benefit of earlier PCI use without delay because of induction protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Non cephalic presentation in childbirth involves various risks to both the mother and the foetus. The incidence in Spain is 3.8% of all full-term pregnancies. The most common technique used to end the gestation in cases of non cephalic presentation is that of caesarian section, and although it provokes a lower rate of morbi-mortality than does vaginal delivery in such situations, there remains the possibility of traumatic injury to the foetal head and neck, while maternal morbidity is also increased. The application of heat (moxibustion) to an acupuncture point, in order to correct non cephalic presentation, has been practised in China since ancient times, but as yet there is insufficient evidence of its real effectiveness. METHODS/DESIGN The experimental design consists of a multi-centre randomised controlled trial with three parallel arms, used to compare real moxibustion, sham moxibustion and the natural course of events, among pregnant women with a non cephalic presentation and a gestational duration of 33-35 weeks (estimated by echography). The participants in the trial will be blinded to both interventions. The results obtained will be analyzed by professionals, blinded with respect to the allocation to the different types of intervention. In addition, we intend to carry out a economic analysis. DISCUSSION This trial will contribute to the development of evidence concerning moxibustion in the correction of non cephalic presentations. The primary outcome variable is the proportion of cephalic presentations at term. As secondary outcomes, we will evaluate the proportion of cephalic presentations at week 38 of gestation, determined by echography, together with the safety of the technique, the specificity of moxibustion and the control of the blinding process. This study has been funded by the Health Ministry of the Andalusian Regional Government. TRIAL REGISTRATION Current Controlled Trials ISRCTN10634508.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of non-profit organizations has grown considerably over thelast decades, however management control techniques are not being introducedwith the same frequency as in lucrative organizations. The increasedcompetition in this sector has created a growing interest in managementcontrol techniques but with little empirical research in the area. Withthe aim to throw some light over the uses of management control inprofessional associations we have focused in the associations foreconomists in Spain as a particular case of a non-lucrative body.Specifically, the paper comprises three surveys addressed to the followingsectors:1) To the 30 Spanish associations of economists.2) To associations related to the business and/or economics area operatingin the United Kingdom.3) To members of the association of economists in Catalonia (Col.legid'Economistes de Catalunya).Results indicate that management accounting tools are used exceptionally,many times only the minimum legal requirements. The critical situation ofthe associations of economists in Spain requires the implementation ofinformation systems, specially taking into account the differentspecialities of economists and offering to its members, services and productsthat are not available through profit organizations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The purpose of this pilot study is to compare the efficacy and tolerance of azithromycin alone as opposed to standard treatment with sulfadiazine and pyrimethamine for active, non-vision-threatening toxoplasmic retinochoroiditis. MATERIAL/METHODS: We conducted a prospective, randomized, institutional clinical study comparing azithromycin to sulfadiazine and pyrimethamine for active, non-vision-threatening toxoplasmic retinochoroiditis. Nineteen out of 75 patients fulfilled inclusion criteria and were randomized into 2 treatment regimens. Nine patients were treated with sulfadiazine and pyrimethamine and 10 patients with azithromycin at a dose of 500 mg qd. Main outcome measures assessed were time to sharpening of lesion borders, time to lesion scarring, time to disease inactivity, and treatment tolerance. RESULTS: Azithromycin monotherapy achieved lesion scarring and disease inactivity in all but 1 patient. Although no statistically significant difference was found between the 2 patient groups as regards main outcome measures for treatment efficacy, all median times to endpoints (days) were longer for the azithromycin group - time to sharpening of lesion borders on clinical evaluation (25.5 vs. 24) and masked evaluation of photographs (30.5 vs. 24), time to lesion scarring on clinical evaluation (73 vs. 47) and masked evaluation of photographs (71.5 vs. 36) and time to disease inactivity (73 vs. 49). Treatment tolerance was significantly better for the azithromycin group (p=0.0005). ConcluSIONS: Azithromycin monotherapy at a dose of 500 mg per day was shown to be effective and well-tolerated for the treatment of active, non-vision-threatening toxoplasmic retinochoroiditis. Duration of treatment was clinically longer for the azithromycin group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context.LS 5039 has been observed with several X-ray instruments so far showing quite steady emission in the long term and no signatures of accretion disk. The source also presents X-ray variability at orbital timescales in flux and photon index. The system harbors an O-type main sequence star with moderate mass-loss. At present, the link between the X-rays and the stellar wind is unclear. Aims.We study the X-ray fluxes, spectra, and absorption properties of LS 5039 at apastron and periastron passages during an epoch of enhanced stellar mass-loss, and the long term evolution of the latter in connection with the X-ray fluxes. Methods.New XMM-Newton observations were performed around periastron and apastron passages in September 2005, when the stellar wind activity was apparently higher. April 2005 Chandra observations on LS 5039 were revisited. Moreover, a compilation of H EW data obtained since 1992, from which the stellar mass-loss evolution can be approximately inferred, was carried out. Results.XMM-Newton observations show higher and harder emission around apastron than around periastron. No signatures of thermal emission or a reflection iron line indicating the presence of an accretion disk are found in the spectrum, and the hydrogen column density () is compatible with being the same in both observations and consistent with the interstellar value. 2005 Chandra observations show a hard X-ray spectrum, and possibly high fluxes, although pileup effects preclude conclusive results from being obtained. The H EW shows yearly variations of 10%, and does not seem to be correlated with X-ray fluxes obtained at similar phases, unlike what is expected in the wind accretion scenario. Conclusions.2005 XMM-Newton and Chandra observations are consistent with 2003 RXTE/PCA results, namely moderate flux and spectral variability at different orbital phases. The constancy of the seems to imply that either the X-ray emitter is located at 1012 cm from the compact object, or the density in the system is 3 to 27 times smaller than that predicted by a spherical symmetric wind model. We suggest that the multiwavelength non-thermal emission of LS 5039 is related to the observed extended radio jets and is unlikely to be produced inside the binary system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Previous published studies have shown significant variations in colonoscopy performance, even when medical factors are taken into account. This study aimed to examine the role of nonmedical factors (ie, embodied in health care system design) as possible contributors to variations in colonoscopy performance. METHODS: Patient data from a multicenter observational study conducted between 2000 and 2002 in 21 centers in 11 western countries were used. Variability was captured through 2 performance outcomes (diagnostic yield and colonoscopy withdrawal time), jointly studied as dependent variables, using a multilevel 2-equation system. RESULTS: Results showed that open-access systems and high-volume colonoscopy centers were independently associated with a higher likelihood of detecting significant lesions and longer withdrawal durations. Fee for service (FFS) payment was associated with shorter withdrawal durations, and so had an indirect negative impact on the diagnostic yield. Teaching centers exhibited lower detection rates and longer withdrawal times. CONCLUSIONS: Our results suggest that gatekeeping colonoscopy is likely to miss patients with significant lesions and that developing specialized colonoscopy units is important to improve performance. Results also suggest that FFS may result in a lower quality of care in colonoscopy practice and highlight the fact that longer withdrawal times do not necessarily indicate higher quality in teaching centers.