974 resultados para nickel, cobalt and copper determination
Resumo:
Occupational exposure to metals such as cobalt and beryllium represents a risk factor for respiratory health and can cause immune-mediated diseases. However, the way they act may be different. We show here that the two metals have a divergent effect on peripheral T lymphocytes and monocytes: BeSO(4) induces cell death in monocytes but not in T lymphocytes, which instead respond by producing Interferon gamma (IFN-γ); conversely, CoCl(2) induces apoptosis in T lymphocytes but not in monocytes. Interestingly, both metals induce p53 overexpression but with a dramatic different outcome. This is because the effect of p53 in CoCl(2)-treated monocytes is counteracted by the antiapoptotic activity of cytoplasmic p21(Cip1/WAF1), the activation of nuclear factor κB, and the inflammasome danger signaling pathway leading to the production of proinflammatory cytokines. However, CoCl(2)-treated monocytes do not fully differentiate into macrophage or dendritic cells, as inferred by the lack of expression of CD16 and CD83, respectively. Furthermore, the expression of HLA-class II molecules, as well as the capability of capturing and presenting the antigens, decreased with time. In conclusion, cobalt keeps monocytes in a partially activated, proinflammatory state that can contribute to some of the pathologies associated with the exposure to this metal.
Resumo:
The concentrated suspension (CS), the basis of Mo trioxide, allows high Mo concentrations and is therefore a technical advance for seed treatment, since it allows the recommendation of the Mo at lower dosage than with the liquid solution formulations (LS). The purpose of this research was to evaluate the efficiency and doses of fertilizer with Mo and Co in concentrated suspension in comparison with liquid solution as well as fertilizers associated with phytohormones, applied in seed treatments, and their effect on soybean yield. Two experiments were carried out in the growing seasons of 2004/2005 and 2005/2006 at the Universidade Federal de Uberlandia (UFU).The first was conducted in an experimental area on the Fazenda Capim Branco, with six treatments and four replications: (1) Mo and Co (CS) - 22 g ha-1 + 1.08 g ha-1; (2) Mo and Co (CS) - 22 g ha-1 + + 1.08 g ha-1 + phytohormone -200 mL ha-1; 3) Mo and Co (LS), 20.7 g ha-1 + 4.13 g ha-1; 4) Mo and Co (LS), 20.7 g ha-1 + 4.13 g ha-1 + phytohormone -200 mL ha-1; (5) + control phytohormone-200 mL ha-1; and (6) control (free of Mo and Co in the seed treatment). The phytohormone consisted of: auxin (11 mg L-1) and cytokynin (0.031 mg L-1). The soybean cultivar Monsoy 8004 was used and a fertilization of 400 kg ha-1 of 02-20-20 NPK fertilizer was applied at sowing. Based on the results of the first experiment, the second was conducted on the Fazenda Floresta do Lobo, in Uberlândia, MG, evaluated in a randomized block design with nine treatments and four replications. The treatments consisted of Mo and Co (g ha-1) doses applied to soybean seeds, as CS formulation (15, 25, 35, 45, 60 and 0.74; 1.23; 1.72; 2.21; 2.95) and LS- (15; 20; 25 and 3.18; 4.25; 5.31), respectively, and the control (free of Mo and Co in the seed treatment). The variety Monarch was used, fertilized with 300 kg ha-1 of NPK fertilizer (03-32-06) at sowing; and 78 kg ha-1 (K2O) in topdressing 30 days after soybean emergence. The Mo and Co doses in the seed treatment with LS and CS resulted in higher soybean yields than in the control, from 20 g ha-1 Mo and 4.25 g ha-1 Co in liquid solution and 35 g ha-1Mo and 1.72 g ha-1 Co in the concentrated suspension.
Resumo:
Doping with natural steroids can be detected by evaluating the urinary concentrations and ratios of several endogenous steroids. Since these biomarkers of steroid doping are known to present large inter-individual variations, monitoring of individual steroid profiles over time allows switching from population-based towards subject-based reference ranges for improved detection. In an Athlete Biological Passport (ABP), biomarkers data are collated throughout the athlete's sporting career and individual thresholds defined adaptively. For now, this approach has been validated on a limited number of markers of steroid doping, such as the testosterone (T) over epitestosterone (E) ratio to detect T misuse in athletes. Additional markers are required for other endogenous steroids like dihydrotestosterone (DHT) and dehydroepiandrosterone (DHEA). By combining comprehensive steroid profiles composed of 24 steroid concentrations with Bayesian inference techniques for longitudinal profiling, a selection was made for the detection of DHT and DHEA misuse. The biomarkers found were rated according to relative response, parameter stability, discriminative power, and maximal detection time. This analysis revealed DHT/E, DHT/5β-androstane-3α,17β-diol and 5α-androstane-3α,17β-diol/5β-androstane-3α,17β-diol as best biomarkers for DHT administration and DHEA/E, 16α-hydroxydehydroepiandrosterone/E, 7β-hydroxydehydroepiandrosterone/E and 5β-androstane-3α,17β-diol/5α-androstane-3α,17β-diol for DHEA. The selected biomarkers were found suitable for individual referencing. A drastic overall increase in sensitivity was obtained.The use of multiple markers as formalized in an Athlete Steroidal Passport (ASP) can provide firm evidence of doping with endogenous steroids. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
Diplomityössä tutkittiin silikarunkoisen, pyridyyliryhmän sisältävän erotusmateriaalin kykyä erottaa selektiivisesti kuparia, nikkeliä, kobolttia ja kadmiumia sinkkisulfaattiliuoksista. Erotuskykyä verrattiin kolonnikokein toiseen kaupalliseen polystyreenidivinyylibentseenirunkoiseen (PS-DVB) erotusmate-riaaliin, jonka funktionaalinen ryhmä on samantyyppinen. Silikarunkoisen erotusmateriaalin happo-emäsominaisuuksia selvitettiin titrauksin. Metallien sitoutumisen kinetiikkaa ja eluointia verrattiin PS-DVB-runkoisen erotus-materiaalin kirjallisuudessa esitettyihin tuloksiin. Lisäksi määritettiin kummankin erotusmateriaalin partikkelikokojakaumat. Silikarunkoisen materiaalin havaittiin turpoavan noin 4 % muutettaessa se vapaastaemäsmuodosta happomuotoon. Turpoaminen oli huomattavasti vähäisempää kuin PS-DVB-runkoisella materiaalilla. Silikarunkoisen erotus-materiaalin titrauksen tuloksena voitiin todeta, että se oli heikosti emäksinen. Titrauskäyrä muistutti PS-DVB-runkoisen erotusmateriaalin titrauskäyrää, vaikka erotusmateriaalien protonoitumisalueet olivat hieman erilaiset. Tämä johtuu siitä, että silikarunkoisen materiaalin funktionaaliset ryhmät poikkeavat rakenteeltaan hieman PS-DVB-runkoisesta materiaalista. Tasapainokokeet osoittivat, että silikarunkoinen erotusmateriaali adsorboi tutkituista metalleista eniten kuparia ja nikkeliä ja vähiten sinkkiä. Kaikkien tutkittujen metallien eluointi silikarunkoisesta erotusmateriaalista onnistui rikkihapolla toisin kuin PS-DVB-runkoisesta erotusmateriaalista, jonka regenerointiin tarvitaan rikkihappoa tai ammoniumhydroksidia riippuen siitä, mitä metalleja siihen on ladattu.
Resumo:
Diplomityön tarkoituksena oli tutkia ja kehittää menetelmä arvometallien kuten kuparin, sinkin, koboltin ja nikkelin talteenottoon metallikloridiliuoksesta. Tavoitteena oli valita taloudellisin ja ympäristöystävällisin menetelmä, jolla saadaan nämä arvometallit myyntituotteiksi. Lisäksi puhdistetun prosessiveden tuli täyttää asetetut tavoitteet. Kirjallisuustyön perusteella laskettiin viidelle eri prosessivaihtoehdolle ainetaseet HSC Sim 6.0 ohjelmalla, joka on HSC Chemistry-pohjainen prosessien simulointi- ja mallinnusohjelma. Kaikissa vaihtoehdoissa oli ensimmäisenä prosessiosana kuparin, sinkin, koboltin ja nikkelin sulfidisaostus ja sakan pesu. Sulfidisaostusta seurasi vaihtoehtoisesti joko 1) hapetus hapella ja hydroksidisaostus, 2) hapetus vetyperoksidilla ja hydroksidisaostus, 3) pelkkä hydroksidisaostus, 4) hapetus SO2/O2-kaasuseoksella ja hydroksidisaostus tai 5) karbonaattisaostus. Taselaskennan perusteella valittiin kokeelliseen osaan tutkittavat prosessivaihtoehdot, jotka olivat sulfidisaostus, hydroksidisaostus, SO2/O2- hapetus ja hydroksidisaostus sekä karbonaattisaostus. Kokeissa arvometallit saatiin talteenotettua sulfidisaostuksella selektiivisimmin lämpötilassa 55 °C ja pH:ssa 4. Näissä olosuhteissa reagenssin kulutus verrattaessa muihin tehtyihin sulfidisaostuksiin oli pienin. Sakka laskeutui ja suotautui hyvin. Loppusakan sisältämien metallien (kupari, sinkki ja koboltti) pitoisuudet olivat korkeimmat. Myös nikkelin määrä oli suuri. Mangaani ja rauta saatiin talteenotettua selektiivisimmin karbonaattisaostuksella lämpötilassa 65 °C. Sakka sisälsi eniten mangaania. Sakka laskeutui ja suotautui hyvin. Tällä menetelmällä puhdistetun prosessiveden laatu täytti asetetut tavoitteet.
Resumo:
This work reports the synthesis and characterization of adducts of general formula MCl2.ngly, where M= Mn and Cu; n= 2 and 4, and gly= glycine. The manganese adducts were synthesized by dissolution of both, manganese chloride and glycine in water, whereas the copper adducts were obtained by using an alternative solid state synthesis approach. For all adducts, the obtained infrared data shows that the coordination involves the amine nitrogen atom, as well as an oxygen atom of the COO- group. The TG curves for the synthesized adducts exhibit only one mass loss step associated with the release of glycine molecules.
Resumo:
Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).
Resumo:
Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for determination of some drugs such as Pramipexole, Nebivolol, Carvedilol, and Eletriptan, which commonly contain secondary amino group. The subject methods were developed via derivatization of the secondary amino groups with 7-Chloro-4-Nitrobenzofurazon in borate buffer where a yellow colored reaction product was obtained and measured spectrophotometrically or spectrofluorimetrically. Concentration ranges were found as 2.0 to 250 μg mL-1 and 0.1 to 3.0 μg mL-1, for spectrophotometric and spectrofluorimetric study, respectively. The described methods can be easily applied by the quality control laboratories in routine analyses of these drugs in pharmaceutical preparations.
Resumo:
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.
Resumo:
This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.
Resumo:
A simple preconcentration method of silicon based on coprecipitation with aluminum hydroxide prior to its flame atomic absorption (FAAS) determination was established. The recovery values of analyte ion was higher than 95%. The parameters including types of hydroxide ion source for precipitation, acid type for dissolution step, amount of aluminum ion as collector, pH, temperature, standing and centrifuge time, and sample volume were optimized for the quantitative recovery of the analyte. The influences of matrix ions were also examined. The relative standard deviation was found to be 3.2%. The limit of detection was calculated as (0.1 mg L-1). The preconcentration factor is 100 for (200 mL) solution. The proposed method was successfully applied for the determination of silicon in some water and alloy samples.
Resumo:
A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) followed by graphite furnace atomic absorption spectrometry (GFAAS). Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.
Resumo:
A method has been developed for the extraction and spectrophotometric determination of Hg2+ in a concentration range of 0.2-1.0 mg L-1; following the Lambert-Beer's law using high molecular weight quaternary ammonium salts dissolved in chloroform. The metal complex anion was determined in the extract in the region UV (260 nm).
Resumo:
Kinosternon scorpioides (Linnaeus, 1766), with its common name of jurará, is a quite variable species of turtles, and many different names have been applied to populations throughout its range. Currently, however, four subspecies are considered valid as K. scorpioides arises from southern Panama over most of northern South America and is found in Ecuador, northern Peru, southern Bolivia, northern Argentina, eastern Guyana and Brazil. Thus, an ultrasonographic and radiographic study was performed in order to describe the morphology and development of eggs of 20 female jurará mud turtles K. scorpioides, from September 2005 to August 2006. In the first month, the ovarian cycle was characterized by absence of vitellogenic follicles, atresic follicles or oviduct eggs. From October 2005 to March 2006 on, ultrasonographic scanning allowed to establish the growing vitellogenic follicles. Vitellogenic follicles were observed with spherical to ovoid shapes, with a surrounding echogenic yolk, a nonechogenic albumin layer, and a high echogenic shell. The oviduct eggs were identified by radiography just 180 days after beginning the experiment, when the shell became enough mineralized to impress the radiographic film. This experiment allowed to obtain by means of the 7.5 MHz linear probe images with adequate resolution and penetration for visualization of follicles. Successive ultrasonographic examinations of 20 K. scorpioides females allowed to access initial stages of vitellogenic follicles and oviduct eggs, and radiographic examination revealed to be an easy technique to assess oviduct eggs and to allow evaluation of egg development in jurarás, from 6 months on.