961 resultados para motion analysis


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Efficient and effective feature detection and representation is an important consideration when processing videos, and a large number of applications such as motion analysis, 3D scene understanding, tracking etc. depend on this. Amongst several feature description methods, local features are becoming increasingly popular for representing videos because of their simplicity and efficiency. While they achieve state-of-the-art performance with low computational complexity, their performance is still too limited for real world applications. Furthermore, rapid increases in the uptake of mobile devices has increased the demand for algorithms that can run with reduced memory and computational requirements. In this paper we propose a semi binary based feature detectordescriptor based on the BRISK detector, which can detect and represent videos with significantly reduced computational requirements, while achieving comparable performance to the state of the art spatio-temporal feature descriptors. First, the BRISK feature detector is applied on a frame by frame basis to detect interest points, then the detected key points are compared against consecutive frames for significant motion. Key points with significant motion are encoded with the BRISK descriptor in the spatial domain and Motion Boundary Histogram in the temporal domain. This descriptor is not only lightweight but also has lower memory requirements because of the binary nature of the BRISK descriptor, allowing the possibility of applications using hand held devices.We evaluate the combination of detectordescriptor performance in the context of action classification with a standard, popular bag-of-features with SVM framework. Experiments are carried out on two popular datasets with varying complexity and we demonstrate comparable performance with other descriptors with reduced computational complexity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations: i) subtraction of the best linear fit from the data (detrending), and; ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s−2). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s−2), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s−2). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the research was to determine the optimal location and method of attachment for accelerometer-based motion sensors, and to validate their ability to differentiate rest and increases in speed in healthy dogs moving on a treadmill. Two accelerometers were placed on a harness between the scapulae of dogs with one in a pouch and one directly attached to the harness. Two additional accelerometers were placed (pouched and not pouched) ventrally on the dog's collar. Data were recorded in 1. s epochs with dogs moving in stages lasting 3. min each on a treadmill: (1) at rest, lateral recumbency, (2) treadmill at 0% slope, 3. km/h, (3) treadmill at 0% slope, 5. km/h, (4) treadmill at 0% slope, 7. km/h, (5) treadmill at 5% slope, 5. km/h, and; (6) treadmill at 5% slope, 7. km/h. Only the harness with the accelerometer in a pouch along the dorsal midline yielded statistically significant increases (P< 0.05) in vector magnitude as walking speed of the dogs increased (5-7. km/h) while on the treadmill. Statistically significant increases in vector magnitude were detected in the dogs as the walking speed increased from 5 to 7. km/h, however, changes in vector magnitude were not detected when activity intensity was increased as a result of walking up a 5% grade. Accelerometers are a valid and objective tool able to discriminate between and monitor different levels of activity in dogs in terms of speed of movement but not in energy expenditure that occurs with movement up hill.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Study Design: Comparative analysis Background: Calculations of lower limbs kinetics are limited by floor-mounted force-plates. Objectives: Comparison of hip joint moments, power and mechanical work on the prosthetic limb of a transfemoral amputee calculated by inverse dynamics using either the ground reactions (force-plates) or knee reactions (transducer). Methods: Kinematics, ground reactions and knee reactions were collected using a motion analysis system, two force-plates and a multi-axial transducer mounted below the socket, respectively. Results: The inverse dynamics using ground reactions under-estimated the peaks of hip energy generation and absorption occurring at 63 % and 76 % of the gait cycle (GC) by 28 % and 54 %, respectively. This method over-estimated a phase of negative work at the hip (from 37 %GC to 56 %GC) by 24%. It under-estimated the phases of positive (from 57 %GC to 72 %GC) and negative (from 73 %GC to 98 %GC) work at the hip by 11 % and 58%, respectively. Conclusions: A transducer mounted within the prosthesis has the capacity to provide more realistic kinetics of the prosthetic limb because it enables assessment of multiple consecutive steps and a wide range of activities without issues of foot placement on force-plates. CLINICAL RELEVANCE The hip is the only joint that an amputee controls directly to set in motion the prosthesis. Hip joint kinetics are associated with joint degeneration, low back pain, risks of fall, etc. Therefore, realistic assessment of hip kinetics over multiple gait cycles and a wide range of activities is essential.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The demand for an evidence-based clinical practice involving lower limb amputees is increasing. Some of the critical care decisions are related to the loading applied on the residuum partially responsible for comfort and functional outcome. This loading can be assessed using inverse dynamics equations. Typically, this method requires a gait laboratory (e.g., 3D motion analysis system, force-plates). It is mainly suited for the analysis only few steps of walking while being expensive and labour intensive. However, recent scientific and industrial developments demonstrated that discrete and light portable sensors can be placed within the prosthesis to measure accurately the loading during an unlimited number of steps and activities of daily living. Several studies indicated that method based on direct measurements might provide more realistic results. Furthermore, it is a user-friendly method more accessible to clinicians, such as prosthetists. The purpose of this symposium will be to give an overview of these additional opportunities for clinicians to obtain relevant data for evidence-based practice. The three main aims will be: • To present some of the equipment used for direct measurements, • To propose ways to analyse some key data sets, • To give some practical example of data sets for transtibial and transfemoral amputees.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Agility is an essential part of many athletic activities. Currently, agility drill duration is the sole criterion used for evaluation of agility performance. The relationship between drill duration and factors such as acceleration, deceleration and change of direction, however, has not been fully explored. This paper provides a mathematical description of the relationship between velocity and radius of curvatures in an agility drill through implementation of a power law (PL). Two groups of skilled and unskilled participants performed a cyclic forward/backward shuttle agility test. Kinematic data was recorded using motion capture system at a sampling rate of 200 Hz. The logarithmic relationship between tangential velocity and radius of curvature of participant trajectories in both groups was established using the PL. The slope of the regression line was found to be 0.26 and 0.36, for the skilled and unskilled groups, respectively. The magnitudes of regression line slope for both groups were approximately 0.3 which is close to the expected 1/3 value. Results are an indication of how the PL could be implemented in an agility drill thus opening the way for establishment of a more representative measure of agility performance instead of drill duration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Previously studies showed that inverse dynamics based on motion analysis and force-plate is inaccurate compared to direct measurements for individuals with transfemoral amputation (TFA). Indeed, direct measurements can appropriately take into account the absorption at the prosthetic foot and the resistance at the prosthetic knee. [1-3] However, these studies involved only a passive prosthetic knee. Aim The objective of the present study was to investigate if different types of prosthetic feet and knees can exhibit different levels of error in the knee joint forces and moments. Method Three trials of walking at self-selected speed were analysed for 9 TFAs (7 males and 2 females, 47±9 years old, 1.76±0.1 m 79±17 kg) with a motion analysis system (Qualisys, Goteborg, Sweden), force plates (Kitsler, Winterthur, Switzerland) and a multi-axial transducer (JR3, Woodland, USA) mounted above the prosthetic knee [1-17]. TFAs were all fitted with an osseointegrated implant system. The prostheses included different type of foot (N=5) and knee (N=3) components. The root mean square errors (RMSE) between direct measurements and the knee joint forces and moments estimated by inverse dynamics were computed for stance and swing phases of gait and expressed as a percentage of the measured amplitudes. A one-way Kruskal-Wallis ANOVA was performed (Statgraphics, Levallois-Perret, France) to analyse the effects of the prosthetic components on the RMSEs. Cross-effects and post-hoc tests were not analysed in this study. Results A significant effect (*) was found for the type of prosthetic foot on anterior-posterior force during swing (p=0.016), lateral-medial force during stance (p=0.009), adduction-abduction moment during stance (p=0.038), internal-external rotation moment during stance (p=0.014) and during swing (p=0.006), and flexion-extension moment during stance (p = 0.035). A significant effect (#) was found for the type of prosthetic knee on anterior-posterior force during swing (p=0.018) and adduction-abduction moment during stance (p=0.035). Discussion & Conclusion The RMSEs were larger during swing than during stance. It is because the errors on accelerations (as derived from motion analysis) become substantial with respect to the external loads. Thus, inverse dynamics during swing should be analysed with caution because the mean RMSEs are close to 50%. Conversely, there were fewer effects of the prosthetic components on RMSE during swing than during stance and, accordingly, fewer effects due to knees than feet. Thus, inverse dynamics during stance should be used with caution for comparison of different prosthetic components.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to compare kinematics and kinetics during walking for healthy subjects using unstable shoes with different designs. Ten subjects participated in this study, and foot biomechanical data during walking were quantified using motion analysis system and a force plate. Data were collected for unstable shoes condition after accommodation period of one week. With soft material added in the heel region, the peak impact force was effectively reduced when compared among similar shapes. In addition, the soft material added in the rocker bottom showed more to be in dorsiflexed position during the initial stance. The shoe with three rocker curves design reduced the contact area in the heel strike, which may result in increasing human body forward speed. Further studies shall be carried out after adapting to long periods of wearing unstable shoes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

M r= 470.46, rhombohedral, R3, a =8.710(4)A, a=91.10(3) o, V= 660.4 (9) A 3, Z= 1,D m= 1.170 (flotation in KI solution), D x=1.183 Mg m -a, Mo Kct, 2 = 0.7107/~,, /t =0.033 mm -1, F(000) - 248.0, T= 293 K, R -- 4.6%(481 unique reflections). The molecule has C a symmetry and is propeller shaped, the angle of twist about the B-C bond being 41.5 (7) °. The space group being chiral, this is yet another example of spontaneous resolution. The results of a thermal-motion analysis are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents an effective feature representation method in the context of activity recognition. Efficient and effective feature representation plays a crucial role not only in activity recognition, but also in a wide range of applications such as motion analysis, tracking, 3D scene understanding etc. In the context of activity recognition, local features are increasingly popular for representing videos because of their simplicity and efficiency. While they achieve state-of-the-art performance with low computational requirements, their performance is still limited for real world applications due to a lack of contextual information and models not being tailored to specific activities. We propose a new activity representation framework to address the shortcomings of the popular, but simple bag-of-words approach. In our framework, first multiple instance SVM (mi-SVM) is used to identify positive features for each action category and the k-means algorithm is used to generate a codebook. Then locality-constrained linear coding is used to encode the features into the generated codebook, followed by spatio-temporal pyramid pooling to convey the spatio-temporal statistics. Finally, an SVM is used to classify the videos. Experiments carried out on two popular datasets with varying complexity demonstrate significant performance improvement over the base-line bag-of-feature method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This PhD research has proposed new machine learning techniques to improve human action recognition based on local features. Several novel video representation and classification techniques have been proposed to increase the performance with lower computational complexity. The major contributions are the construction of new feature representation techniques, based on advanced machine learning techniques such as multiple instance dictionary learning, Latent Dirichlet Allocation (LDA) and Sparse coding. A Binary-tree based classification technique was also proposed to deal with large amounts of action categories. These techniques are not only improving the classification accuracy with constrained computational resources but are also robust to challenging environmental conditions. These developed techniques can be easily extended to a wide range of video applications to provide near real-time performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is concerned with the optimal flow control of an ATM switching element in a broadband-integrated services digital network. We model the switching element as a stochastic fluid flow system with a finite buffer, a constant output rate server, and a Gaussian process to characterize the input, which is a heterogeneous set of traffic sources. The fluid level should be maintained between two levels namely b1 and b2 with b1motion analysis and derive the limiting distribution for the queue length touching the critical levels. Also the application of instantaneous control on the ATM network is considered

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Crystals of Boc-gamma y(4)(R)Val-Val-OH undergo a reversible first-order single crystal to single crystal phase transition at T-c approximate to 205 K from the orthorhombic space group P22(1)2(1) (Z' = 1) to the monoclinic space group P2(1) (Z' = 2) with a hysteresis of similar to 2.1 K. The low-temperature monoclinic form is best described as a nonmerohedral twin with similar to 50% contributions from its two components. The thermal behavior of the dipeptide crystals was characterized by differential scanning calorimetry experiments. Visual changes in birefringence of the sample during heating and cooling cycles on a hot-stage microscope with polarized light supported the phase transition. Variable-temperature unit cell check measurements from 300 to 100 K showed discontinuity in the volume and cell parameters near the transition temperature, supporting the first-order behavior. A detailed comparison of the room-temperature orthorhombic form with the low-temperature (100 K) monoclinic form revealed that the strong hydrogen-bonding motif is retained in both crystal systems, whereas the non-covalent interactions involving side chains of the dipeptide differ significantly, leading to a small change in molecular conformation in the monoclinic form as well as a small reorientation of the molecules along the ac plane. A rigid-body thermal motion analysis (translation, libration, screw; correlation of translation and libration) was performed to study the crystal entropy. The reversible nature of the phase transition is probably the result of an interplay between enthalpy and entropy: the low-temperature monoclinic form is enthalpically favored, whereas the room-temperature orthorhombic form is entropically favored.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

为分析空间电动绳系的运动特性,从一般力学角度出发,结合电动力学知识,建立了近地轨道空间电动绳系推进飞行的动力学模型,得出了多种初始条件下的数值计算结果,并据此对电动绳系航天器的轨道机动过程进行了详尽的讨论,阐明了系统在轨道高度变化的同时,其轨道面也会发生变化,而且导电系绳还会旋转与弯曲变形等规律.此外,还对电动绳系推进系统的效率和地球自转的影响进行了估计.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

提出并研制一种基于自适应移动机构的管内探查机器人。通过对机器人传动机构的设计,实现了在不增加驱动电动机数量的前提下,机器人具有适应不同管道直径的能力。机器人的传动机构能够在管道直径改变时,自动地改变行走部件的输出形式以克服障碍,完成越障任务。在没有应用链式多节构型的情况下,机器人配备一个驱动电动机就能够完成越障任务,改善了传统螺旋驱动式机器人越障能力不高的问题,同时也提高了对驱动电动机的使用效率。为了分析试验中发现的机器人保持架自转现象,对机器人进行运动分析,并由分析结果对相关部分进行改进。试验结果表明,该机器人能够在内径为190 mm和180 mm的管道中行进,并能够顺利通过两节管道间形成的同心台阶障碍,验证了自适应移动机构的行走能力。