897 resultados para medication safety review
Resumo:
As digital technologies become widely used in designing buildings and infrastructure, questions arise about their impacts on construction safety. This review explores relationships between construction safety and digital design practices with the aim of fostering and directing further research. It surveys state-of-the-art research on databases, virtual reality, geographic information systems, 4D CAD, building information modeling and sensing technologies, finding various digital tools for addressing safety issues in the construction phase, but few tools to support design for construction safety. It also considers a literature on safety critical, digital and design practices that raises a general concern about ‘mindlessness’ in the use of technologies, and has implications for the emerging research agenda around construction safety and digital design. Bringing these strands of literature together suggests new kinds of interventions, such as the development of tools and processes for using digital models to promote mindfulness through multi-party collaboration on safety
Resumo:
In recent years, there have been increasing concerns over the safety of the Chinese food supply. Although many of these have only raised concern internally within China, several major food safety issues have had international repercussions. In response, China has implemented new food safety laws and management systems to improve its national food safety control system and reduce public and international concerns. This paper has describes and discusses the components of the Chinese system using the five key elements of a national food control system identified by the World Health Organization (WHO) and the Food and Agriculture Organization (FAO) as essential for an effective system. The latest Chinese national food safety control has made significantly improvement on its regulation framework, however, more work need to be done on standards, law enforcement, and information exchange.
Resumo:
Introduction: Care home residents are at particular risk from medication errors, and our objective was to determine the prevalence and potential harm of prescribing, monitoring, dispensing and administration errors in UK care homes, and to identify their causes. Methods: A prospective study of a random sample of residents within a purposive sample of homes in three areas. Errors were identified by patient interview, note review, observation of practice and examination of dispensed items. Causes were understood by observation and from theoretically framed interviews with home staff, doctors and pharmacists. Potential harm from errors was assessed by expert judgement. Results: The 256 residents recruited in 55 homes were taking a mean of 8.0 medicines. One hundred and seventy-eight (69.5%) of residents had one or more errors. The mean number per resident was 1.9 errors. The mean potential harm from prescribing, monitoring, administration and dispensing errors was 2.6, 3.7, 2.1 and 2.0 (0 = no harm, 10 = death), respectively. Contributing factors from the 89 interviews included doctors who were not accessible, did not know the residents and lacked information in homes when prescribing; home staff’s high workload, lack of medicines training and drug round interruptions; lack of team work among home, practice and pharmacy; inefficient ordering systems; inaccurate medicine records and prevalence of verbal communication; and difficult to fill (and check) medication administration systems. Conclusions: That two thirds of residents were exposed to one or more medication errors is of concern. The will to improve exists, but there is a lack of overall responsibility. Action is required from all concerned.
Resumo:
Purpose: Small renal masses are increasingly being discovered incidentally on imaging for another reason. The standard of care of these masses involves excision by open or laparoscopic techniques. Recently, ablative techniques, such as radiofrequency ablation (RFA) and cryoablation, have taken a more prominent role in the treatment algorithm of these masses. We evaluate the effectiveness and safety of cryoablation to treat renal tumours. Methods: A review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: the Cochrane Library, PUBMED, EMBASE and LILACS. Results: There was no clinical trial identified in the literature. Thus, we described the results from 23 case series and retrospective studies with a reasonable sample size (number of reported patients in each study ≥30), with a total of 2104 analyzed tumours from 2038 patients. There was wide variability in the outcomes reported, but success rates were generally good. Follow-up was generally short, but some series reported outcomes at 5 years. The most common complications reported were hemorrhage (some of the patients requiring transfusion), perinephric hematoma and urine leaks. Conclusion: Cryoablation presents a feasible treatment for patients with small renal masses. Only short-term data are available and, as such, meaningful conclusions regarding long-term cancer control cannot be made. More rigorous studies are needed. © 2013 Canadian Urological Association.
Resumo:
Background. Measles control may be more challenging in regions with a high prevalence of HIV infection. HIV-infected children are likely to derive particular benefit from measles vaccines because of an increased risk of severe illness. However, HIV infection can impair vaccine effectiveness and may increase the risk of serious adverse events after receipt of live vaccines. We conducted a systematic review to assess the safety and immunogenicity of measles vaccine in HIV-infected children. Methods. The authors searched 8 databases through 12 February 2009 and reference lists. Study selection and data extraction were conducted in duplicate. Meta-analysis was conducted when appropriate. Results. Thirty-nine studies published from 1987 through 2008 were included. In 19 studies with information about measles vaccine safety, more than half reported no serious adverse events. Among HIV-infected children, 59% (95% confidence intervals [CI], 46–71%) were seropositive after receiving standard-titer measles vaccine at 6 months (1 study), comparable to the proportion of seropositive HIV-infected children vaccinated at 9 (8 studies) and 12 months (10 studies). Among HIV-exposed but uninfected and HIV-unexposed children, the proportion of seropositive children increased with increasing age at vaccination. Fewer HIV-infected children were protected after vaccination at 12 months than HIV-exposed but uninfected children (relative risk, 0.61; 95% CI, .50–.73). Conclusions. Measles vaccines appear to be safe in HIV-infected children, but the evidence is limited. When the burden of measles is high, measles vaccination at 6 months of age is likely to benefit children of HIV-infected women, regardless of the child's HIV infection status.
Resumo:
A systematic literature review was conducted to assess the effectiveness of, compliance with, and critical factors for the implementation of safety checklists in surgery.
Resumo:
Aerosols are the most promising non-injectable method of measles vaccination studied so far and their efficacy is thought to be comparable to injected vaccine. We conducted a systematic review up to May 2006 to examine the immunogenicity and safety of aerosolized measles vaccine (Edmonston-Zagreb or Schwarz strains) 1 month or more after vaccination. Where possible we estimated pooled serological response rates and odds ratios (with 95% confidence intervals, CI) comparing aerosolized and subcutaneous vaccines in children in three age groups and adults. We included seven randomized trials, four non-randomized trials and six uncontrolled studies providing serological outcome data on 2887 individuals. In children below 10 months, the studies were heterogeneous. In four comparative studies, seroconversion rates were lower with aerosolized than with subcutaneous vaccine and in two of these the difference was unlikely to be due to chance. In children 10-36 months, the pooled seroconversion rate with aerosolized vaccine was 93.5% (89.4-97.7%) and 97.1% (92.4-100%) with subcutaneous vaccine (odds ratio 0.27, 0.04-1.62). In 5-15-year olds the studies were heterogeneous. In all comparative studies aerosolized vaccine was more immunogenic than subcutaneous. Reported side effects were mild. Aerosolized measles vaccine appears to be equally or more immunogenic than subcutaneous vaccine in children aged 10 months and older. Large randomized trials are needed to establish the efficacy and safety of aerosolized measles vaccine as primary and booster doses.
Resumo:
PURPOSES: To evaluate the safety of inferior vena cava (IVC) filter retrieval in therapeutically anticoagulated patients in comparison to prophylactically or not therapeutically anticoagulated patients with respect to retrieval-related hemorrhagic complications. MATERIALS AND METHODS: This was a retrospective study of 115 consecutive attempted IVC filter retrievals in 110 patients. Filter retrievals were stratified as performed in patients who were therapeutically anticoagulated (group 1), prophylactically anticoagulated (group 2), or not therapeutically anticoagulated (group 3). The collected data included anticoagulant and antiplatelet medications (type, form and duration of administration, dosage) at the time of retrieval. Phone interviews and chart review was performed for the international normalized ratio (INR), activated partial thromboplastin time, platelet count, infusion of blood products, and retrieval-related hemorrhagic complications. RESULTS: Group 1 included 65 attempted filter retrievals in 61 therapeutically anticoagulated patients by measured INR or dosing when receiving low-molecular-weight heparin (LMWH). Four retrievals were not successful. In patients receiving oral anticoagulation, the median INR was 2.35 (range, 2 to 8). Group 2 comprised 23 successful filter retrievals in 22 patients receiving a prophylactic dose of LMWH. Group 3 included 27 attempted filter retrievals in 27 patients not receiving therapeutic anticoagulation. Six retrievals were not successful. Five patients were receiving oral anticoagulation with a subtherapeutic INR (median, 1.49; range, 1.16 to 1.69). No anticoagulation medication was administered in 22 patients. In none of the groups were hemorrhagic complications related to the retrieval procedures identified. CONCLUSIONS: These results suggest that retrieval of vena cava filters in anticoagulated patients is safe. Interruption or reversal of anticoagulation for the retrieval of vena cava filters is not indicated.
Resumo:
BACKGROUND AND PURPOSE: : Proton radiation has been used for the treatment of uveal melanoma since 1975, but few studies have been conducted to assess its efficacy and safety. This paper aims to systematically review the effects and side effects of proton therapy for any indication of the eye. MATERIAL AND METHODS: : A range of databases were searched from inception to 2007. All studies that included at least ten patients and that assessed the efficacy or safety of proton therapy for any indication of the eye were included. RESULTS: : The search generated 2,385 references, of which 37 met the inclusion criteria. Five controlled trials, two comparative studies and 30 case series were found, most often reporting on uveal melanoma, choroidal melanoma and age-related macular degeneration (AMD). Methodological quality of these studies was poor. Studies were characterized by large differences in radiation techniques applied within the studies, and by variation in patient characteristics within and between studies. Results for uveal melanoma and choroidal melanoma suggest favorable survival, with, however, significant rates of side effects. Results for choroidal hemangioma and AMD did not reveal beneficial effects from proton radiation. CONCLUSION: : There is limited evidence on the effectiveness and safety of proton radiation due to the lack of well-designed and well-reported studies. There is a need to lift evidence on proton therapy to a higher level by performing dose-finding randomized controlled trials (RCTs), comparative studies of proton radiation versus standard given alternatives and prospective case studies enrolling only patients treated with up-to-date techniques, allowing extrapolation of results to similar patient groups.
Resumo:
BACKGROUND Up to one third of BKP treated cases shows no appreciable height restoration due to loss of both restored height and kyphotic realignment after balloon deflation. This shortcoming has called for an improved method that maintains the height and realignment reached by the fully inflated balloon until stabilization of the vertebral body by PMMA-based cementation. Restoration of the physiological vertebral body height for pain relief and for preventing further fractures of adjacent and distant vertebral bodies must be the main aim for such a method. A new vertebral body stenting system (VBS) stabilizes the vertebral body after balloon deflation until cementation. The radiographic and safety results of the first 100 cases where VBS was applied are presented. METHODS During the planning phase of an ongoing international multicenter RCT, radiographic, procedural and followup details were retrospectively transcribed from charts and xrays for developing and testing the case report forms. Radiographs were centrally assessed at the institution of the first/senior author. RESULTS 100 patients (62 with osteoporosis) with a total of 103 fractured vertebral bodies were treated with the VBS system. 49 were females with a mean age of 73.2 years; males were 66.7 years old. The mean preoperative anterior-middle-posterior heights were 20.3-17.6-28.0 mm, respectively. The mean local kyphotic angle was 13.1[degree sign]. The mean preoperative Beck Index (anterior edge height/posterior edge height) was 0.73, the mean alternative Beck Index (middle height/posterior edge height) was 0.63. The mean postoperative heights were restored to 24.5-24.6-30.4 mm, respectively. The mean local kyphotic angle was reduced to 8.9[degree sign]. The mean postoperative Beck Index was 0.81, the mean alternative one was 0.82. The overall extrusion rate was 29.1%, the symptomatic one was 1%. In the osteoporosis subgroup there were 23.8% extrusions. Within the three months followup interval there were 9% of adjacent and 4% of remote new fractures, all in the osteoporotic group. CONCLUSIONS VBS showed its strengths especially in realignment of crush and biconcave fractures. Given that fracture mobility is present, the realignment potential is sound and increases with the severity of preoperative vertebral body deformation.
Resumo:
BACKGROUND Metamizole is used to treat pain in many parts of the world. Information on the safety profile of metamizole is scarce; no conclusive summary of the literature exists. OBJECTIVE To determine whether metamizole is clinically safe compared to placebo and other analgesics. METHODS We searched CENTRAL, MEDLINE, EMBASE, CINAHL, and several clinical trial registries. We screened the reference lists of included trials and previous systematic reviews. We included randomized controlled trials that compared the effects of metamizole, administered to adults in any form and for any indication, to other analgesics or to placebo. Two authors extracted data regarding trial design and size, indications for pain medication, patient characteristics, treatment regimens, and methodological characteristics. Adverse events (AEs), serious adverse events (SAEs), and dropouts were assessed. We conducted separate meta-analyses for each metamizole comparator, using standard inverse-variance random effects meta-analysis to pool the estimates across trials, reported as risk ratios (RRs). We calculated the DerSimonian and Laird variance estimate T2 to measure heterogeneity between trials. The pre-specified primary end point was any AE during the trial period. RESULTS Of the 696 potentially eligible trials, 79 trials including almost 4000 patients with short-term metamizole use of less than two weeks met our inclusion criteria. Fewer AEs were reported for metamizole compared to opioids, RR = 0.79 (confidence interval 0.79 to 0.96). We found no differences between metamizole and placebo, paracetamol and NSAIDs. Only a few SAEs were reported, with no difference between metamizole and other analgesics. No agranulocytosis or deaths were reported. Our results were limited by the mediocre overall quality of the reports. CONCLUSION For short-term use in the hospital setting, metamizole seems to be a safe choice when compared to other widely used analgesics. High-quality, adequately sized trials assessing the intermediate- and long-term safety of metamizole are needed.
Resumo:
Background/Study Context: Older drivers are at increased risk of becoming involved in car crashes. Contrary to well-studied illness-related factors contributing to crash risk, the non-illness-related factors that can influence safety of older drivers are underresearched. METHODS: Here, the authors review the literature on non-illness-related factors influencing driving in people over age 60. We identified six safety-relevant factors: road infrastructure, vehicle characteristics, traffic-related knowledge, accuracy of self-awareness, personality traits, and self-restricted driving. RESULTS: The literature suggests that vehicle preference, the quality of traffic-related knowledge, the location and time of traffic exposure, and personality traits should all be taken into account when assessing fitness-to-drive in older drivers. Studies indicate that self-rating of driving skills does not reliably predict fitness-to-drive. CONCLUSIONS: Most factors discussed are adaptable or accessible to training and collectively may have the potential to increase traffic safety for older drivers and other road users.
Resumo:
The purpose of this research was to determine if principles from organizational theory could be used as a framework to compare and contrast safety interventions developed by for-profit industry for the time period 1986–1996. A literature search of electronic databases and manual search of journals and local university libraries' book stacks was conducted for safety interventions developed by for-profit businesses. To maintain a constant regulatory environment, the business sectors of nuclear power, aviation and non-profits were excluded. Safety intervention evaluations were screened for scientific merit. Leavitt's model from organization theory was updated to include safety climate and renamed the Updated Leavitt's Model. In all, 8000 safety citations were retrieved, 525 met the inclusion criteria, 255 met the organizational safety intervention criteria, and 50 met the scientific merit criteria. Most came from non-public health journals. These 50 were categorized by the Updated Leavitt's Model according to where within the organizational structure the intervention took place. Evidence tables were constructed for descriptive comparison. The interventions clustered in the areas of social structure, safety climate, the interaction between social structure and participants, and the interaction between technology and participants. No interventions were found in the interactions between social structure and technology, goals and technology, or participants and goals. Despite the scientific merit criteria, many still had significant study design weaknesses. Five interventions tested for statistical significance but none of the interventions commented on the power of their study. Empiric studies based on safety climate theorems had the most rigorous designs. There was an attempt in these studies to address randomization amongst subjects to avoid bias. This work highlights the utility of using the Updated Leavitt's Model, a model from organizational theory, as a framework when comparing safety interventions. This work also highlights the need for better study design of future trials of safety interventions. ^
Resumo:
Errors in the administration of medication represent a significant loss of medical resources and pose life altering or life threatening risks to patients. This paper considered the question, what impact do Computerized Physician Order Entry (CPOE) systems have on medication errors in the hospital inpatient environment? Previous reviews have examined evidence of the impact of CPOE on medication errors, but have come to ambiguous conclusions as to the impact of CPOE and decision support systems (DSS). Forty-three papers were identified. Thirty-one demonstrated a significant reduction in prescribing error rates for all or some drug types; decreases in minor errors were most often reported. Several studies reported increases in the rate of duplicate orders and failures to remove contraindicated drugs, often attributed to inappropriate design or to an inability to operate the system properly. The evidence on the effectiveness of CPOE to reduce errors in medication administration is compelling though it is limited by modest study sample sizes and designs. ^
Resumo:
Medication reconciliation, with the aim to resolve medication discrepancy, is one of the Joint Commission patient safety goals. Medication errors and adverse drug events that could result from medication discrepancy affect a large population. At least 1.5 million adverse drug events and $3.5 billion of financial burden yearly associated with medication errors could be prevented by interventions such as medication reconciliation. This research was conducted to answer the following research questions: (1a) What are the frequency range and type of measures used to report outpatient medication discrepancy? (1b) Which effective and efficient strategies for medication reconciliation in the outpatient setting have been reported? (2) What are the costs associated with medication reconciliation practice in primary care clinics? (3) What is the quality of medication reconciliation practice in primary care clinics? (4) Is medication reconciliation practice in primary care clinics cost-effective from the clinic perspective? Study designs used to answer these questions included a systematic review, cost analysis, quality assessments, and cost-effectiveness analysis. Data sources were published articles in the medical literature and data from a prospective workflow study, which included 150 patients and 1,238 medications. The systematic review confirmed that the prevalence of medication discrepancy was high in ambulatory care and higher in primary care settings. Effective strategies for medication reconciliation included the use of pharmacists, letters, a standardized practice approach, and partnership between providers and patients. Our cost analysis showed that costs associated with medication reconciliation practice were not substantially different between primary care clinics using or not using electronic medical records (EMR) ($0.95 per patient per medication in EMR clinics vs. $0.96 per patient per medication in non-EMR clinics, p=0.78). Even though medication reconciliation was frequently practiced (97-98%), the quality of such practice was poor (0-33% of process completeness measured by concordance of medication numbers and 29-33% of accuracy measured by concordance of medication names) and negatively (though not significantly) associated with medication regimen complexity. The incremental cost-effectiveness ratios for concordance of medication number per patient per medication and concordance of medication names per patient per medication were both 0.08, favoring EMR. Future studies including potential cost-savings from medication features of the EMR and potential benefits to minimize severity of harm to patients from medication discrepancy are warranted. ^