909 resultados para measurement and metrology
Resumo:
Methodological approaches in which data on nonverbal behavior are collected usually involve interpretive methods in which raters must identify a set of defined categories of behavior. However, present knowledge about the qualitative aspects of head movement behavior calls for recording detailed transcriptions of behavior. These records are a prerequisite for investigating the function and meaning of head movement patterns. A method for directly collecting data on head movement behavior is introduced. Using small ultrasonic transducers, which are attached to various parts of an index person's body (head and shoulders), a microcomputer defines receiver-transducers distances. Three-dimensional positions are calculated by triangulation. These data are used for further calculations concerning the angular orientation of the head and the direction, size, and speed of head movements (in rotational, lateral, and sagittal dimensions).
Resumo:
In this paper, we show statistical analyses of several types of traffic sources in a 3G network, namely voice, video and data sources. For each traffic source type, measurements were collected in order to, on the one hand, gain better understanding of the statistical characteristics of the sources and, on the other hand, enable forecasting traffic behaviour in the network. The latter can be used to estimate service times and quality of service parameters. The probability density function, mean, variance, mean square deviation, skewness and kurtosis of the interarrival times are estimated by Wolfram Mathematica and Crystal Ball statistical tools. Based on evaluation of packet interarrival times, we show how the gamma distribution can be used in network simulations and in evaluation of available capacity in opportunistic systems. As a result, from our analyses, shape and scale parameters of gamma distribution are generated. Data can be applied also in dynamic network configuration in order to avoid potential network congestions or overflows. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
Bipolar mixed states combine depressive and manic features, presenting diagnostic and treatment challenges and reflecting a severe form of the illness. DSM-IV criteria for a mixed state require combined depressive and manic syndromes, but a range of mixed states has been described clinically. A unified definition of mixed states would be valuable in understanding their diagnosis, mechanism and treatment implications. We investigated the manner in which depressive and manic features combine to produce a continuum of mixed states. In 88 subjects with bipolar disorder (DSM-IV), we evaluated symptoms and clinical characteristics, and compared depression-based, mania-based, and other published definitions of mixed states. We developed an index of the extent to which symptoms were mixed (Mixed State Index, MSI) and characterized its relationship to clinical state. Predominately manic and depressive mixed states using criteria from recent literature, as well as Kraepelinian mixed states, had similar symptoms and MSI scores. Anxiety correlated significantly with depression scores in manic subjects and with mania scores in depressed subjects. Discriminant function analysis associated mixed states with symptoms of hyperactivity and negative cognitions, but not subjective depressive or elevated mood. High MSI scores were associated with severe course of illness. For depressive or manic episodes, characteristics of mixed states emerged with two symptoms of the opposite polarity. This was a cross-sectional study. Mixed states appear to be a continuum. An index of the degree to which depressive and manic symptoms combine appears useful in identifying and characterizing mixed states. We propose a depressive or manic episode with three or more symptoms of the opposite polarity as a parsimonious definition of a mixed state.
Resumo:
The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of root s = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K-s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5 % for central isolated hadrons and 1-3 % for the final calorimeter jet energy scale.
Resumo:
The BepiColombo Laser Altimeter (BELA) has been selected to fly on ESA׳s BepiColombo mission to Mercury. The instrument will be the first European laser altimeter designed for interplanetary flight. This paper describes the setup used to characterize the angular movements of BELA under the simulated environmental conditions that the instrument will encounter when orbiting Mercury. The system comprises a laser transmitter and a receiving telescope, which can move with respect to each other under thermal load. Tests performed using the Engineering Qualification Model show that the setup is accurate enough to characterize angular movements of the instrument components to an accuracy of ≈10 μrad. The qualification instrument is thermally stable to operate during all mission phases around Mercury proving that the transmitter and receiver sections will remain within the alignment requirements during its mission.
Resumo:
A detailed characterization of air quality in the megacity of Paris (France) during two 1-month intensive campaigns and from additional 1-year observations revealed that about 70% of the urban background fine particulate matter (PM) is transported on average into the megacity from upwind regions. This dominant influence of regional sources was confirmed by in situ measurements during short intensive and longer-term campaigns, aerosol optical depth (AOD) measurements from ENVISAT, and modeling results from PMCAMx and CHIMERE chemistry transport models. While advection of sulfate is well documented for other megacities, there was surprisingly high contribution from long-range transport for both nitrate and organic aerosol. The origin of organic PM was investigated by comprehensive analysis of aerosol mass spectrometer (AMS), radiocarbon and tracer measurements during two intensive campaigns. Primary fossil fuel combustion emissions constituted less than 20%in winter and 40%in summer of carbonaceous fine PM, unexpectedly small for a megacity. Cooking activities and, during winter, residential wood burning are the major primary organic PM sources. This analysis suggests that the major part of secondary organic aerosol is of modern origin, i.e., from biogenic precursors and from wood burning. Black carbon concentrations are on the lower end of values encountered in megacities worldwide, but still represent an issue for air quality. These comparatively low air pollution levels are due to a combination of low emissions per inhabitant, flat terrain, and a meteorology that is in general not conducive to local pollution build-up. This revised picture of a megacity only being partially responsible for its own average and peak PM levels has important implications for air pollution regulation policies.
Resumo:
Research has shown that physical activity serves a preventive function against the development of several major chronic diseases. However, studying physical activity and its health benefits is difficult due to the complexity of measuring physical activity. The overall aim of this research is to contribute to the knowledge of both correlates and measurement of physical activity. Data from the Women On The Move study were used for this study (n = 260), and the results are presented in three papers. The first paper focuses on the measurement of physical activity and compares an alternate coding method with the standard coding method for calculating energy expenditure from a 7-day activity diary. Results indicate that the alternative coding scheme could produce similar results to the standard coding in terms of total activity expenditure. Even though agreement could not be achieved by dimension, the study lays the groundwork for a coding system that saves considerable amount of time in coding activity and has the ability to estimate expenditure more accurately for activities that can be performed at varying intensity levels. The second paper investigates intra-day variability in physical activity by estimating the variation in energy expenditure for workers and non-workers and identifying the number of days of diary self-report necessary to reliably estimate activity. The results indicate that 8 days of activity are needed to reliably estimate total activity for individuals who don't work and 12 days of activity are needed to reliably estimate total activity for those who work. Days of diary self-report required by dimension for those who don't work range from 6 to 16 and for those who work from 6 to 113. The final paper presents findings on the relationship between daily living activity and Type A behavior pattern. Significant findings are observed for total activity and leisure activity with the Temperament Scale summary score. Significant findings are also observed for total activity, household chores, work, leisure activity, exercise, and inactivity with one or more of the individual items on the Temperament Scale. However, even though some significant findings were observed, the overall models did not reveal meaningful associations. ^
Resumo:
A reliable assessment of relevant substance flows is very important for environmental risk assessments and efficiency analysis of measures to reduce or avoid emissions of micropollutants like drugs to water systems. Accordingly, a detailed preparation of monitoring campaigns should include an accuracy check for the sampling configuration to prove the reliability of the monitoring results and the subsequent data processing. The accuracy of substance flow analyses is expected to be particularly weak for substances having high short-term variations of concentrations in sewage. This is especially the case linked to the observation of substance flows close to source in waste water systems. The verification of a monitoring configuration in a hospital sewer in Luxembourg is in the centre of interest of the case study presented here. A tracer test in the sewer system under observation is an essential element of the suggested accuracy check and provides valuable information for an uncertainty analysis. The results illustrate the importance of accuracy checks as an essential element of the preparation of monitoring campaigns. Moreover the study shows that continuous flow proportional sampling enables a representative observation of short-term peak loads of the iodinated x-ray contrast media iobitridol close to source.
Resumo:
This Master Final Project is intended to show the process developed to the functional and electrical characterization between different devices that use the SpaceWire space communications standard integrated into an evaluation board designed for this purpose. In order to carry out this characterization, firstly, a study to understand the SpaceWire standard is done. After that, another study for the understanding of the demonstration board with its different interfaces and IPs of SpW is done. According to this, it is expected to find out how the SpW devices are structured, especially at FPGA level, and how is the communication between them. Based on the knowledge obtained about SpaceWire and the SpW devices integrated into the evaluation board, the set of measurements and the strategy to validate electrical interoperability between the different devices are defined, as well as to perform functional checks required to ensure its proper understanding. Furthermore, it will let check whether the standard is met and search the limit of operation within a communication system representative of existing equipment in a satellite. Once finished the test plan and implemented on the representative hardware, the board will be considered characterized at SpW level and a report with the conclusions reached about the operation of the SpW interfaces in the board and constraints found will be done. RESUMEN. El presente Trabajo Fin de Máster pretende mostrar el proceso realizado para la caracterización eléctrica y funcional entre distintos dispositivos que utilizan el estándar de comunicaciones espaciales SpaceWire integrados en una tarjeta de evaluación diseñada para tal efecto. Para poder llevar a cabo dicha caracterización, en primer lugar, se realiza un estudio para el conocimiento del estándar SpaceWire. A continuación, se lleva a cabo otro estudio para el conocimiento de la tarjeta de demostración en la que se encuentran los distintos interfaces e IPs de SpW. Con esto último, se pretende conocer como están estructurados los dispositivos SpW, sobre todo a nivel de FPGA, y como se realiza la comunicación entre ellos. En base a los conocimientos adquiridos acerca de SpaceWire y los dispositivos SpW de la tarjeta de evaluación, se definen el conjunto de medidas y la estrategia a seguir para validar eléctricamente la interoperabilidad entre los distintos dispositivos, así como para realizar las comprobaciones funcionales necesarias para asegurar su correcto entendimiento. Además, con ello se podrá comprobar si se cumple el estándar y se podrá también buscar el límite de operación dentro de un sistema de comunicaciones representativo de los equipos existentes en un satélite. Realizado el plan de pruebas y aplicado sobre el hardware representativo se podrá dar por caracterizada la tarjeta a nivel SpW y realizar un informe con las conclusiones alcanzadas acerca del funcionamiento de los interfaces SpW de la tarjeta y las limitaciones encontradas.