995 resultados para material handling


Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"May 1992."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"May 1988."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Iron ore concentrate pellets have the potential to fracture and abrade during transportation and handling, which produces unwanted fine particulates and dust. Consequently, pellet producers characterize the abrasion resistance of their pellets, using an Abrasion Index (AI), to indicate whether their products will produce unacceptable levels of fines. However, no one has ever investigated whether the AI correlates to pellet dustiness. During the course of this research, we investigated the relationship between AI and iron ore concentrate pellet dustiness using a wide range of industrial and laboratory pellet samples. The results showed that, in general, AI can be used to indicate high levels of dust. However, for good-quality pellets, there was no correlation between the two. Thus, dust generation from shipping and handling pellets will depend on the quantity of pellets handled and how much they are handled. These results also showed that the type of industrial furnace used to harden iron ore concentrate pellets may affect their fines generation and potential dustiness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stingless bees collect plant resins and make it into propolis, although they have a wider range of use for this material than do honey bees (Apis spp.). Plebeia spp. workers employ propolis mixed with wax (cerumen) for constructing and sealing nest structures, while they use viscous (sticky) propolis for defense by applying it onto their enemies. Isolated viscous propolis deposits are permanently maintained at the interior of their colonies, as also seen in other Meliponini species. Newly-emerged Plebeia emerina (Friese) workers were observed stuck to and unable to escape these viscous propolis stores. We examined the division of labor involved in propolis manipulation, by observing marked bees of known age in four colonies of P. emerina from southern Brazil. Activities on brood combs, the nest involucrum and food pots were observed from the first day of life of the marked bees. However, work on viscous propolis deposits did not begin until the 13th day of age and continued until the 56th day (maximum lifespan in our sample). Although worker bees begin to manipulate cerumen early, they seem to be unable to handle viscous propolis till they become older.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement of the charge distribution in laboratory generated aerosols particles was carried out. Four cases of electrostatic charge acquisition by aerosol particles were evaluated. In two of these cases. the charges acquired by the particles were naturally derived from the aerosol generation procedure itself, without using any additional charging method. Ill the other two cases, a corona charger and an impact charger were utilized as Supplementary methods for charge generation. Two types of aerosol generators were used in the dispersion of particles in the gas Stream: the vibrating orifice generator TSI model 3450 and the rotating plate generator TSI model 3433. In the vibrating orifice generator. a Solution of methylene blue Was used and the generated particles were mono-dispersed. Different mono-aerosols were generated with particle diameters varying from 6.0 x 10(-6) m to 1.4 x 10(-5) m. In the rotating plate generator, a poly-dispersed phosphate rock concentrate with Stokes mean diameter of 1.30 x 10(-6) m and size range between 1.5 x 10(-7) m and 8.0 x 10(-6) m Was utilized as powder material in all tests. In the tests performed with the mono-dispersed particles. the median charges of the particles varied between -3.0 x 10-(16) C and -5.0 x 10(-18) degrees C and a weak dependence between particle size and charge was observed. The particles were predominantly negatively charged. In the tests with the poly-dispersed particles the median charges varied fairly linearly with the particle diameter and were negative. The order of magnitude of the results obtained is in accordance with data reported in the literature. The charge distribution, in this case, was wider, so that an appreciable amount of particles were positively charged. The relative spread of the distribution varied with the charging method. It was also noticed that the corona charger acted very effectively in charging the particles. (C) 2008 Elsevier BY. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Development and standardization of reliable methods for detection of Mycobacterium tuberculosis in clinical samples is an important goal in laboratories throughout the world. In this work, lung and spleen fragments from a patient who died with the diagnosis of miliary tuberculosis were used to evaluate the influence of the type of fixative as well as the fixation and paraffin inclusion protocols on PCR performance in paraffin embedded specimens. Tissue fragments were fixed for four h to 48 h, using either 10% non-buffered or 10% buffered formalin, and embedded in pure paraffin or paraffin mixed with bee wax. Specimens were submitted to PCR for amplification of the human beta-actin gene and separately for amplification of the insertion sequence IS6110, specific from the M. tuberculosis complex. Amplification of the beta-actin gene was positive in all samples. No amplicons were generated by PCR-IS6110 when lung tissue fragments were fixed using 10% non-buffered formalin and were embedded in paraffin containing bee wax. In conclusion, combined inhibitory factors interfere in the detection of M. tuberculosis in stored material. It is important to control these inhibitory factors in order to implement molecular diagnosis in pathology laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recommendations and laws do not always contain specific and clear provisions on the use of cadaveric material in research, and even more rarely do they address explicitly the ethical issues related to research on material obtained during forensic autopsy. In this article we analyse existing legal frameworks in Europe by comparing the legal provisions in 2 European Countries which are member states of the Council of Europe, the UK and Switzerland. They were chosen because they have distinct legal frameworks that make comparisons interesting. In addition, the detailed laws of the UK and a specific law project and national ethical recommendations in Switzerland permit us to define more clearly the legal range of options for researchers using cadaveric material obtained during forensic investigations. The Human Tissue Act 2004 in England, Wales and Northern Ireland, its Scottish equivalent with the same title (2006) and the national ethical guidelines in Switzerland all require consent from the deceased person, an appropriate relative or a person with power of attorney for healthcare decisions before cadaveric biological material can be obtained and used for research. However, if the purpose of the autopsy is purely forensic, no such authorization will be sought to carry out the autopsy and related analyses, which might include genetic testing. In order to be allowed to carry out future research projects, families need to be approached for informed consent, unless the deceased person had left written directives including permission to use his or her tissues for research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Selostus: Ryhmäkoon ja varhaisen käsittelyn vaikutus tarhattujen sinikettujen hyvinvointiin

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.