Resumo:
BACKGROUND: We observed a remarkable increase in the number of young patients who presented with lung emphysema and secondary spontaneous pneumothorax (SSP) at our institution for over a period of 30 months; most of them have a common history of marijuana abuse. STUDY DESIGN: Retrospective case series. METHODS: Seventeen young patients presented with spontaneous pneumothorax with bullous lung emphysema were systematically evaluated over a period of 30 months. All were regular marijuana smokers. Clinical history, chest X-ray, CT-scan, lung function test, and laboratory and histological examinations were assessed. We compared the findings of this group (group I) with the findings of non-marijuana smoking patients (group II) in the same period. The findings of this series were also compared with the findings of 75 patients presented with pneumothorax in a previous period from January 2000 till March 2002 (group III). RESULTS: In group I, there were 17 patients: the median age of the patients was 27 years (range 19-43 years), 16 males and 1 female. All were living in Switzerland. All but one smoked marijuana daily for a mean of 8.8 years and tobacco for 11.8 years. CT-scan showed multiple bullae at the apex or significant bullous emphysema with predominance in the upper lobes only in two patients. Only two patients had reduced forced first second expiratory volume (FEV1) and one reduced vital capacity (VC) below the predicted 50%. This correlated with the subjectively asymptomatic condition of the patients. All but two patients were treated by video-assisted thoracoscopic surgery (VATS) for prevention of relapsing pneumothorax. Histology showed severe lung emphysema, inflammation, and heavily pigmented macrophages. In group II, there were 85 patients: there were 78 males, the median age was 24 years (range 17-40 years), 74 patients smoked tobacco for 13.4 years but no marijuana. CT-scan in 72 patients showed only small bullae at the apex but no significant emphysema; other clinical, laboratory, and histopathological findings showed no significant difference in group I. In group III, there were 75 patients: there were 71 males and 4 females. Mean age was 25 years (range 16-46 years). Six smoked marijuana daily for a mean of 3.2 years, and 62 smoked tobacco for 14 years. CT-scan done in 59 patients showed few small bullae at the apex but no significant lung emphysema. The presence of lung emphysema on CT-scan in group I was significantly different than in groups II and III (p=0.14). No significant difference was found among all groups in the form of clinical, laboratory, and histopathological findings. CONCLUSIONS: In case of emphysema in young individuals, marijuana abuse has to be considered in the differential diagnosis. The period of marijuana smoking seems to play an important role in the development of lung emphysema. This obviously quite frequent condition in young and so far asymptomatic patients will have medical, financial, and ethical impact, as some of these patients may be severely handicapped or even become lung transplant candidates in the future.
Resumo:
The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.
Resumo:
to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents.
Resumo:
OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.
Resumo:
Background: Up to 60% of chronic obstructive pulmonary disease ( COPD) patients can present airway hyperresponsiveness. However, it is not known whether the peripheral lung tissue also shows an exaggerated response to agonists in COPD. Objectives: To investigate the in vitro mechanical behavior and the structural and inflammatory changes of peripheral lung tissue in COPD patients and compare to nonsmoking controls. Methods: We measured resistance and elastance at baseline and after acetylcholine (ACh) challenge of lung strips obtained from 10 COPD patients and 10 control subjects. We also assessed the alveolar tissue density of neutrophils, eosinophils, macrophages, mast cells and CD8+ and CD4+ cells, as well as the content of alpha-smooth muscle actin-positive cells and elastic and collagen fibers. We further investigated whether changes in in vitro parenchymal mechanics correlated to structural and inflammatory parameters and to in vivo pulmonary function. Results: Values of resistance after ACh treatment and the percent increase in tissue resistance (%R) were higher in the COPD group (p <= 0.03). There was a higher density of macrophages and CD8+ cells (p < 0.05) and a lower elastic content (p = 0.003) in the COPD group. We observed a positive correlation between %R and eosinophil and CD8+ cell density (r = 0.608, p = 0.002, and r = 0.581, p = 0.001, respectively) and a negative correlation between %R and the ratio of forced expiratory volume in 1 s to forced vital capacity (r = -0.451, p < 0.05). Conclusions: The cholinergic responsiveness of parenchymal lung strips is increased in COPD patients and seems to be related to alveolar tissue eosinophilic and CD8 lymphocytic inflammation and to the degree of airway obstruction on the pulmonary function test. Copyright (C) 2011 S. Karger AG, Basel
Resumo:
Background: Impairment in pulmonary capacity due to pleural effusion compromises daily activity. Removal of fluid improves symptoms, but the impact, especially on exercise capacity, has not been determined. Methods: Twenty-five patients with unilateral pleural effusion documented by chest radiograph were included. The 6-min walk test, Borg modified dyspnea score, FVC, and FEV, were analyzed before and 48 h after the removal of large pleural effusions. Results: The mean fluid removed was 1,564 +/- 695 mL. After the procedure, values of FVC, FEV and 6-min walk distance increased (P<.001), whereas dyspnea decreased (P<.001). Statistical correlations (P<.001) between 6-min walk distance and FVC (r=0.725) and between 6-min walk distance and FEV, (r=0.661) were observed. Correlations also were observed between the deltas (prethoracentesis X postthoracentesis) of the 6-min walk test and the percentage of FVC (r=0.450) and of FEV, (r=0.472) divided by the volume of fluid removed (P<.05). Conclusion: In addition to the improvement in lung function after thoracentesis, the benefits of fluid removal are more evident in situations of exertion, allowing better readaptation of patients to routine activities. CHEST 2011; 139(6):1424-1429
Resumo:
Study design: Cross-sectional study. Objective: Pulmonary functional capacity in 23 Brazilian quadriplegic subjects (ASIA A), aged 30 (9.5) years, weight 66 (10.75) kg, height 176 (7) cm, was investigated at 42 ( 64) months postinjury. Setting: University Hospital-UNICAMP, Campinas, Brazil. Method: Subjects performed forced vital capacity ( FVC) and maximal voluntary ventilation (MVV) tests while seated in their standard wheelchairs. Forced Expired Volume after 1 s (FEV1) and FVC/FEV1 ratio were calculated from these tests. Values obtained were compared to three prediction equations from the literature that are used specifically for spinal cord subjects and include different variables in their formulae, such as age, gender, height, postinjury time and injury level. Data are expressed as median (interquartile interval). Differences between values were demonstrated by median confidence interval with significance level set at a 0.05. Results: Obtained data were statistically different from prediction equation results, with FVC 3.11 ( 0.81), 4.46 (0.28), 4.16 (0.33), 4.26 (0.42); FEV1 2.77 (1.03), 3.67 (0.21), 3.66 (0.30), 3.45 (0.39) and MVV 92 (27), 154.2 (11.9), 156.6 (14),157.3 (16.8), where the first value is obtained experimentally and the second, third and fourth values correspond to predicted values. The results obtained from spirometry test in this study differed significantly from the results obtained when prediction equations were used. Conclusion: The use of prediction equations developed to estimate pulmonary function in wheelchair users significantly overestimates pulmonary function of quadriplegic individuals with complete lesions (ASIA group A), in comparison to measured values.
Resumo:
BACKGROUND: Outcome after lung transplantation (LTx) is affected by the onset of bronchiolitis obliterans syndrome (BOS) and lung function decline. Reduced health-related quality of life (HRQL) and physical mobility have been shown in patients developing BOS, but the impact on the capacity to walk is unknown. We aimed to compare the long-term HRQL and 6-minute walk test (6MWT) between lung recipients affected or not by BOS Grade > or =2. METHODS: Fifty-eight patients were prospectively followed for 5.6 +/- 2.9 years after LTx. Assessments included the St George's Respiratory Questionnaire (SGRQ) and the 6MWT, which were performed yearly. Moreover, clinical complications were recorded to estimate the proportion of the follow-up time lived without clinical intercurrences after transplant. Analyses were performed using adjusted linear regression and repeated-measures analysis of variance. RESULTS: BOS was a significant predictor of lower SGRQ scores (p < 0.01) and reduced time free of clinical complications (p = 0.001), but not of 6MWT distance (p = 0.12). At 7 years post-transplant, results were: 69.0 +/- 21.8% vs 86.9 +/- 5.6%, p < 0.05 (SGRQ); 58.5 +/- 21.6% vs 88.7 +/- 11.4%, p < 0.01 (proportion of time lived without clinical complications); and 82.2 +/- 10.9% vs 91.9 +/- 14.2%, p = 0.27 (percent of predicted 6MWT), respectively, for patients with BOS and without BOS. CONCLUSIONS: Despite significantly less time lived without clinical complications and progressive decline of self-reported health status, the capacity to walk of patients affected by BOS remained relatively stable over time. These findings may indicate that the development of moderate to severe BOS does not prevent lung recipients from walking independently and pursuing an autonomous life.
Resumo:
BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.
Resumo:
Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P=0.003), minute volume per kilogram (P=0.001) and peak inspiratory and expiratory flows per kilogram (P=0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats.
Resumo:
Abstract Background Measurement of vital capacity (VC) by spirometry is the most widely used technique for lung function evaluation, however, this form of assessment is costly and further investigation of other reliable methods at lower cost is necessary. Objective: To analyze the correlation between direct vital capacity measured with ventilometer and with incentive inspirometer in patients in pre and post cardiac surgery. Methodology Cross-sectional comparative study with patients undergoing cardiac surgery. Respiratory parameters were evaluated through the measurement of VC performed by ventilometer and inspirometer. To analyze data normality the Kolmogorov-Smirnov test was applied, for correlation the Pearson correlation coefficient was used and for comparison of variables in pre and post operative period Student's t test was adopted. We established a level of ignificance of 5%. Data was presented as an average, standard deviation and relative frequency when needed. The significance level was set at 5%. Results We studied 52 patients undergoing cardiac surgery, 20 patients in preoperative with VC-ventilometer: 32.95 ± 11.4 ml/kg and VC-inspirometer: 28.9 ± 11 ml/Kg, r = 0.7 p < 0.001. In the post operatory, 32 patients were evaluated with VC-ventilometer: 28.27 ± 12.48 ml/kg and VC-inspirometer: 26.98 ± 11 ml/Kg, r = 0.95 p < 0.001. Presenting a very high correlation between the evaluation forms studied. Conclusion There was a high correlation between DVC measures with ventilometer and incentive spirometer in pre and post CABG surgery. Despite this, arises the necessity of further studies to evaluate the repercussion of this method in lowering costs at hospitals.
Resumo:
BACKGROUND: Outcome after lung transplantation (LTx) is affected by the onset of bronchiolitis obliterans syndrome (BOS) and lung function decline. Reduced health-related quality of life (HRQL) and physical mobility have been shown in patients developing BOS, but the impact on the capacity to walk is unknown. We aimed to compare the long-term HRQL and 6-minute walk test (6MWT) between lung recipients affected or not by BOS Grade > or =2. METHODS: Fifty-eight patients were prospectively followed for 5.6 +/- 2.9 years after LTx. Assessments included the St George's Respiratory Questionnaire (SGRQ) and the 6MWT, which were performed yearly. Moreover, clinical complications were recorded to estimate the proportion of the follow-up time lived without clinical intercurrences after transplant. Analyses were performed using adjusted linear regression and repeated-measures analysis of variance. RESULTS: BOS was a significant predictor of lower SGRQ scores (p < 0.01) and reduced time free of clinical complications (p = 0.001), but not of 6MWT distance (p = 0.12). At 7 years post-transplant, results were: 69.0 +/- 21.8% vs 86.9 +/- 5.6%, p < 0.05 (SGRQ); 58.5 +/- 21.6% vs 88.7 +/- 11.4%, p < 0.01 (proportion of time lived without clinical complications); and 82.2 +/- 10.9% vs 91.9 +/- 14.2%, p = 0.27 (percent of predicted 6MWT), respectively, for patients with BOS and without BOS. CONCLUSIONS: Despite significantly less time lived without clinical complications and progressive decline of self-reported health status, the capacity to walk of patients affected by BOS remained relatively stable over time. These findings may indicate that the development of moderate to severe BOS does not prevent lung recipients from walking independently and pursuing an autonomous life.
Resumo:
The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.
Resumo:
BACKGROUND Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM Our aim was to challenge the validity of these software algorithms. METHODS We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes.
Resumo:
Apesar da utilização da ventilação mecânica protetora como estratégia para o tratamento da síndrome do desconforto respiratório agudo, ao menos um quarto dos pacientes com essa síndrome ainda apresentam redução na função pulmonar após 6 meses de seguimento. Não se sabe se esta redução está relacionada com a gravidade da síndrome ou associada com a forma de ventilar o paciente. Nosso objetivo neste trabalho foi avaliar a associação entre alterações funcionais e estruturais do pulmão com parâmetros de gravidade clínica e de ventilação mecânica. Foi realizada uma análise secundária dos dados obtidos em estudo randomizado e controlado que incluiu pacientes com síndrome do desconforto respiratório agudo moderada/grave, internados em seis unidades de terapia intensiva em um hospital terciário da cidade de São Paulo. Foram analisados dados de pacientes que tinham ao menos um teste de função pulmonar no seguimento. O teste funcional incluiu a medida da capacidade vital forçada, volumes pulmonares e a capacidade de difusão do monóxido de carbono após 1, 2 e 6 meses de seguimento. Foram considerados variáveis independentes o volume corrente, a pressão de distensão e a pressão positiva ao final da expiração (todos medidos após 24 horas da randomização) e um sistema de classificação de prognóstico (APACHE II), a relação PaO2/FIO2 e a complacência respiratória estática (todos medidos antes da randomização). Também foi realizada tomografia de alta resolução do tórax juntamente com os testes de função pulmonar, e posterior análise quantitativa das imagens. Na avaliação de 6 meses também foi realizado teste de caminhada de 6 minutos e um questionário de qualidade de vida (SF-36). Um total de 21 pacientes realizaram o teste de função pulmonar após 1 mês e 15 pacientes realizaram após 2 e 6 meses de seguimento. A capacidade vital forçada foi relacionada inversamente com a pressão de distensão na avaliação de 1, 2 e 6 meses (p < 0,01). A capacidade de difusão do monóxido de carbono relacionou-se inversamente com a pressão de distensão e com o APACHE II (ambos p < 0,01) na avaliação de 1 e 2 meses. Após 6 meses de seguimento, houve correlação inversa entre a pressão de distensão e a capacidade vital forçada independente do volume corrente, da pressão de platô e da complacência estática respiratória após ajustes (R2 = 0,51, p = 0,02). A pressão de distensão também se relacionou com o volume pulmonar total, a densidade pulmonar media e a porcentagem de volume pulmonar não aerado ou pobremente aerado medidos através da análise quantitativa da tomografia computadorizada de tórax realizada na avaliação de 6 meses. Também foi observada relação entre a qualidade de vida após 6 meses de seguimento e a pressão de distensão considerando o domínio estado geral de saúde. Nós concluímos que mesmo em pacientes ventilados com reduzido volume corrente e pressão de platô limitada, maiores valores de pressão de distensão relacionaram-se com menores valores de função pulmonar no seguimento de longo prazo