874 resultados para low vision rehabilitation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose:  Most recently light and mobile reading devices with high display resolutions have become popular and they may open new possibilities for reading applications in education, business and the private sector. The ability to adapt font size may also open new reading opportunities for people with impaired or low vision. Based on their display technology two major groups of reading devices can be distinguished. One type, predominantly found in dedicated e-book readers, uses electronic paper also known as e-Ink. Other devices, mostly multifunction tablet-PCs, are equipped with backlit LCD displays. While it has long been accepted that reading on electronic displays is slow and associated with visual fatigue, this new generation is explicitly promoted for reading. Since research has shown that, compared to reading on electronic displays, reading on paper is faster and requires fewer fixations per line, one would expect differential effects when comparing reading behaviour on e-Ink and LCD. In the present study we therefore compared experimentally how these two display types are suited for reading over an extended period of time. Methods:  Participants read for several hours on either e-Ink or LCD, and different measures of reading behaviour and visual strain were regularly recorded. These dependent measures included subjective (visual) fatigue, a letter search task, reading speed, oculomotor behaviour and the pupillary light reflex. Results:  Results suggested that reading on the two display types is very similar in terms of both subjective and objective measures. Conclusions:  It is not the technology itself, but rather the image quality that seems crucial for reading. Compared to the visual display units used in the previous few decades, these more recent electronic displays allow for good and comfortable reading, even for extended periods of time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim. To review and explore cataract prevalence in stable and unstable countries by examining published and unpublished ocular literature about Africa from 1980 onwards.^ Methods. Searches using OVID, Proquest Dissertations, WHO, and Ebsco Host were done. The review was restricted to articles utilizing WHO definitions of blindness and low vision. Random cluster sampling technique with a minimum sample size of 1,500, and reporting causes of blindness categorized by age and gender were inclusion considerations in the selected articles. ^ Results. Blindness and low vision increased with conflict. Women and the elderly were more likely to have vision impairing cataract. Cataract was the leading cause of blindness; the prevalence range was 22%–81% for the reviewed nations.^ Conclusion. Instability was connected to higher cataract prevalence and worse visual outcome across all characteristics examined except cataract surgical rates. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Enmarcado en un proyecto más amplio, en este TFG se ha realizado un prototipo funcional de una aplicación Android para realizar una función de magnificador digital de documentos en papel. Para llevarlo a cabo se ha realizado un estudio de los TFG anteriores incluidos en este proyecto, así como un estudio del desarrollo en Android. Posteriormente se ha diseñado la interfaz de usuario del prototipo funcional, partiendo de los resultados de la evaluación del prototipo de baja fidelidad realizado en un TFG anterior. Tras este diseño se ha Implementado el prototipo funcional, usando las librerías desarrolladas en TFG anteriores. Por último, se ha realizado una evaluación de la usabilidad y accesibilidad del prototipo funcional y se han definido una serie de recomendaciones de cambio a partir de esta evaluación de cara al desarrollo del sistema definitivo. ---ABSTRACT---As a part of a larger project, this TFG develops a functional prototype of an Android application to perform a magnifier function to paper documents. This application is aimed at people with low vision problems. To get it done, a study of the previous TFG included in this project as well as a study of Android developing has been made. After that, the user interface of the functional prototype has been designed, starting from the results of the low-fidelity prototype evaluation made in a previous TFG. In this design, several changes have been made regarding the low-fidelity prototype, applying the results of the usability evaluation. After this design, the functional prototype has been implemented using the libraries developed in the previous TFG. In this process some modifications over these libraries have been required. Finally, a usability and accessibility evaluation about the prototype with real users has been made, and there have been defined several change recommendations from this evaluation having in mind the development of the final system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En este Trabajo fin de Grado se ha creado la parte funcional de una aplicación móvil dejando la parte de la interfaz libre para su futura implementación. La aplicación es un magnificador y está destinada a aquellas personas con baja visión, permitiéndoles hacer aumento de imágenes y textos capturados por la cámara del dispositivo, con la posibilidad de que puedan cambiar algunos parámetros de la magnificación para poderlo ver mejor. La parte funcional de la aplicación fue nombrada como librería magnificador, ya que se compone de métodos implementados en Java que permiten hacer diferentes modificaciones de la imagen o del video visualizado. Se cubrieron todas las fases de desarrollo más significativas de un sistema software: análisis, diseño, implementación y pruebas. La aplicación se desarrolló para Android. Se trabajó en Eclipse con Android SDK. Para el procesamiento de las imágenes se aprovechó una librería externa, OpenCV, para evitar “inventar la rueda”, es decir, no escribir algoritmos de transformación de las imágenes que seguramente no podrían ser tan eficientes como los implementados en dicha librería creada por Intel. ---ABSTRACT---In this Final Project, the functional part of mobile phone application was created, leaving the interface parte for future implementation. The application is a magnifier and is oriented to people with very low vision allowing them to enlarge images of printed documents captured by the camera of the mobile phone device, with the possibility that they can change some parameters of magnification so that it can see better. The functional part of this application was named magnifier library because it composes of methods, implemented in Java, that allows changing between different modes of the preview of the image or video. All of the most significant phases of software development were satisfied: analysis, design, implementation and tests. The application was created for Android. The work was done in Eclipse with Android SDK plugin. For the image processing, an external library, OpenCv, was used, to avoid the unreachable intent of creation of effective algorithms that would never be so potent like the implemented in this library created by Intel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Enquadramento: O acesso à saúde ocular em escolares dirige primariamente a prevenção de problemas visuais que dificultem o aprendizado, impossibilitando o desenvolvimento das atividades intelectuais e sociais. Os projetos de promoção da saúde oftalmológica são, para a grande maioria dos alunos, a primeira e rara oportunidade de avaliar a visão. Objetivos: Identificar os tipos de déficit visuais mais comuns nas crianças da região metropolitana do Recife; Identificar as queixas mais frequentes relacionadas a baixa de visão; Realizar campanha preventiva para identificação dos déficits, tendo como referência a Guarnição de Aeronáutica de Recife (GAR). Métodos: Estudo descritivo, transversal, intervencionista e quantitativo. A pesquisa ocorreu nos anos de 2013 e 2014, em uma população de 1500 crianças residentes na cidade de Recife, estado de Pernambuco, Brasil, com idades variando entre 7 e 9 anos, onde obtivemos uma amostra de 490 inscrições para participação no programa. Resultados: No primeiro período, atingimos 98,5% de objetividade, aumentando para 99,3% no segundo período. Os estudantes realizaram as consultas maioritariamente pela manhã (58,7%), em escola particular (81,6%) e na sua maioria (57,1%), eram do sexo feminino. A presença de queixas atingiu 78,6% e os sinais e sintomas mais referidos foram: cefaleia (20,8%), prurido ocular (17,6%) e dificuldade de enxergar o quadro (16,8%). Foram identificados e corrigidos 53 casos de erros de refração sendo o astigmatismo (4,74%), o mais diagnosticado, 7 casos de estrabismo e tratados 12 de conjuntivite. Conclusões: Em 2013, 15,1% e em 2014, 14,2% das crianças apresentaram baixa acuidade visual. Astigmatismo e miopia representam 10% dos problemas mais comuns seguidos de hipermetropia e conjuntivite. 84% do total de nossa amostra refere dificuldade de visualização no quadro negro, 68% manifestam cefaleias, 85% dor ocular, 75,5% vermelhidão ocular e 80,3% prurido ocular. Resumindo, os distúrbios visuais são comuns nas crianças, justificando programas de saúde preventiva nas unidades de saúde da FAB. Palavras-chave: Acuidade visual; Criança; Preventiva.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"February 2002."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background/aims: Network 1000 is a UK-based panel survey of a representative sample of adults with registered visual impairment, with the aim of gathering information about people’s opinions and circumstances. Method: Participants were interviewed (Survey 1, n = 1007: 2005; Survey 2, n = 922: 2006/07) on a range of topics including the nature of their eye condition, details of other health issues, use of low vision aids (LVAs) and their experiences in eye clinics. Results: Eleven percent of individuals did not know the name of their eye condition. Seventy percent of participants reported having long-term health problems or disabilities in addition to visual impairment and 43% reported having hearing difficulties. Seventy one percent reported using LVAs for reading tasks. Participants who had become registered as visually impaired in the previous 8 years (n = 395) were asked questions about non-medical information received in the eye clinic around that time. Reported information received included advice about ‘registration’ (48%), low vision aids (45%) and social care routes (43%); 17% reported receiving no information. While 70% of people were satisfied with the information received, this was lower for those of working age (56%) compared with retirement age (72%). Those who recalled receiving additional non-medical information and advice at the time of registration also recalled their experiences more positively. Conclusions: Whilst caution should be applied to the accuracy of recall of past events, the data provide a valuable insight into the types of information and support that visually impaired people feel they would benefit from in the eye clinic.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To develop a standardized questionnaire of near visual function and satisfaction to complement visual function evaluations of presbyopic corrections. Setting Eye Clinic, School of Life and Health Sciences, Aston University, Midland Eye Institute and Solihull Hospital, Birmingham, United Kingdom. Design Questionnaire development. Methods A preliminary 26-item questionnaire of previously used near visual function items was completed by patients with monofocal intraocular lenses (IOLs), multifocal IOLs, accommodating IOLs, multifocal contact lenses, or varifocal spectacles. Rasch analysis was used for item reduction, after which internal and test–retest reliabilities were determined. Construct validity was determined by correlating the resulting Near Activity Visual Questionnaire (NAVQ) scores with near visual acuity and critical print size (CPS), which was measured using the Minnesota Low Vision Reading Test chart. Discrimination ability was assessed through receiver-operating characteristic (ROC) curve analysis. Results One hundred fifty patients completed the questionnaire. Item reduction resulted in a 10-item NAVQ with excellent separation (2.92), internal consistency (Cronbach a = 0.95), and test–retest reliability (intraclass correlation coefficient = 0.72). Correlations of questionnaire scores with near visual acuity (r = 0.32) and CPS (r = 0.27) provided evidence of validity, and discrimination ability was excellent (area under ROC curve = 0.91). Conclusion Results show the NAVQ is a reliable, valid instrument that can be incorporated into the evaluation of presbyopic corrections.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: To determine the best method of estimating the optimum magnification needed by visually impaired patients. Methods: The magnification of low vision aids prescribed to 187 presbyopic visually impaired patients for reading newspapers or books was compared with logMAR distance and near acuity (at 25 cm) and magnification predicted by +4 D step near additions. Results: Distance letter (r = 0.58) and near word visual acuity (r = 0.67) were strongly correlated to the prescribed magnification as were predictive formulae based on these measures. Prediction using the effect of proximal magnification resulted in a similar correlation (r = 0.67) and prediction was poorer in those who did not benefit from proximal magnification. The difference between prescribed and predicted magnification was found to be unrelated to the condition causing visual impairment (F = 2.57, p = 0.08), the central visual field status (F = 0.57, p = 0.57) and patient psychology (F = 0.44, p = 0.51), but was higher in those prescribed stand magnifiers than high near additions (F = 5.99, p < 0.01). Conclusions: The magnification necessary to perform normal visual tasks can be predicted in the majority of cases using visual acuity measures, although measuring the effect of proximal magnification demonstrates the effect of stronger glasses and identifies those in whom prescribed magnification is more difficult to predict.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Prescribing magnification is typically based on distance or near visual acuity. this presumes a constant minimum angle of visual resolution with working distance and therefore enlargement of an object moved to a shorter working distance (relative distance enlargement). this study examines this premise in a visually impaired population. methods: distance letter visual acuity was measured prospectively for 380 low vision patients (distance visual acuity between 0.3 and 2.1 logmar) over the age of 57 years, along with near word visual acuity at an appropriate distance for near lens additions from +4 d to +20 D. demographic information, the disease causing low vision, contrast sensitivity, visual field and psychological status were also recorded. results: distance letter acuity was significantly related to (r = 0.84) but on average 0.1 ± 0.2 logmar better (1 ± 2 lines on a logmar chart) than near word acuity at 25 cm with a +4 d lens addition. in 39. 8 per cent of patients, near word acuity was more than 0.1 logmar worse than distance letter acuity. in 11.0 per cent of subjects, near visual acuity was more than 0.1 logmar better than distance letter acuity. the group with near word acuity worse than distance letter acuity also had lower contrast sensitivity. the group with near word acuity better than distance letter acuity was less likely to have age-Related macular degeneration. smaller print size could be read by reducing working distance (achieved by using higher near lens additions) in 86. 1 per cent, although not by as much as predicted by geometric progression in 14. 5 per cent. discussion: although distance letter and near word acuity are highly related, they are on average 1 logmar line different and this varies significantly between individuals. near word acuity did not increase linearly with relative distance enlargement in approximately one in seven visually impaired, suggesting that the measurement of visual resolution over a range of working distances will assist appropriate prescribing of magnification aids.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.