932 resultados para low energy radiation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes the development of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the system started with the characterisation of detectors purchased for this specific task, with the optimisation of the different desired measurement configurations following and ending with the installation and check of the results. A new software has been developed to handle the new detectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tesi nasce da un'attività di ricerca approfondita su alcune tecnologie innovative e all'avanguardia nell'ambito del mobile computing e dell'Internet of Things. Tra queste il focus principale è orientato allo studio del Bluetooth Low Energy, nuova specifica di Bluetooth caratterizzata principalmente da un consumo di energia assai ridotto. In particolare, si è approfondito il suo funzionamento nel caso dei beacon, piccoli dispositivi che permettono una localizzazione mediante l'invio di un segnale BLE. Inoltre è stata analizzata la possibilità di interazione con Android, poiché oggigiorno non si può evitare di pensare a come queste tecnologie possano interfacciarsi con il mondo degli smartphone e dei tablet. Come conseguenza di tale attività di ricerca è stato analizzato un caso di studio che permettesse di applicare le tecnologie studiate e la loro interazione. Si è pensato quindi a un piccolo sistema distribuito per schermi adattativi (capaci di modificare i contenuti visualizzati in relazione ad eventi esterni) affinché ogni schermo mostrasse dinamicamente l'orario delle lezioni di ciascuno studente all'avvicinarsi di quest'ultimo, e solo per il tempo di permanenza nei pressi dello schermo. Si è quindi progettato e sviluppato un prototipo, e infine durante il testing si sono potute verificare le attuali potenzialità di queste tecnologie e trarre conclusioni sulla possibilità della loro futura diffusione e di impiego in contesti differenti.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lo scopo dell’elaborato di tesi è la progettazione e lo sviluppo di un’applicazione per il modulo Bluetooth Low Energy (BLE) Texas Instrument CC2650 in grado di leggere le informazioni da un sensore analogico, tramite un Analog-Digital- Converter (ADC), e di scambiare i dati con uno smartphone Android in tempo reale. L’interfaccia realizzata deve essere universale, ovvero dovrà essere compatibile con sensori di diverso tipo, facilmente estensibile per l’aggiunta di un numero maggiore di periferiche di lettura e utilizzabile con un ampio numero di dispositivi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo elaborato è stato effettuato uno studio di soluzioni tecnologiche per eseguire una localizzazione di prossimità in ambienti indoor tramite la percezione di segnali Bluetooth Low Energy. Il sistema analizzato e sperimentato è composto da un dispositivo in ricezione che effettua una stima della distanza che intercorre con il trasmettitore, tramite la valutazione della potenza del segnale ricevuto. A causa della propagazione indoor, tale stima risulta poco accurata in termini di ranging in quanto vengono a generarsi delle fluttuazioni istantanee del segnale ricevuto dovute a fenomeni di multipath. L’obiettivo di questo progetto è stato quello di mitigare queste oscillazioni sfruttando due trasmettitori al posto di uno, effettuando quindi in ricezione opportune combinazioni fra i segnali ricevuti (Diversity Combining Techniques).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In questo elaborato sono stati confrontati i moduli bluetooth WT11, BLE113 , BT121 rispetto alle loro caratteristiche di banda, consumo, range e utilizzabilita in un contesto applicativo stringente come quello degli utilizzi biomeccanici. Si sono prima elencati i settori di riferimento, per poi descrivere il contesto applicativo in ambito medico e sportivo. Il confronto finale ha tenuto conto delle modalita di comunicazione bluetooth classic e bluetooth low energy, cercando di motivare quale modulo risulti migliore per questo particolare e innovativo contesto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation for 4 and 6 MeV electron beams of Varian linear accelerators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Breast cancer is the most common cancer among women. Tamoxifen is the preferred drug for estrogen receptor-positive breast cancer treatment, yet many of these cancers are intrinsically resistant to tamoxifen or acquire resistance during treatment. Therefore, scientists are searching for breast cancer drugs that have different molecular targets. Previous work revealed that 8-mer and cyclic 9-mer peptides inhibit breast cancer in mouse and rat model systems, interacting with an unknown receptor, while peptides smaller than eight amino acids did not inhibit breast cancer. We have shown that the use of replica exchange molecular dynamics predicts structure and dynamics of active peptides, leading to the discovery of smaller peptides with full biological activity. These simulations identified smaller peptide analogs with a conserved turn, a β-turn formed in the larger peptides. These analogs inhibit estrogen-dependent cell growth in a mouse uterine growth assay, a test showing reliable correlation with human breast cancer inhibition. We outline the computational methods that were tried and used with the experimental information that led to the successful completion of this research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The low-energy β− emitter 161Tb is very similar to 177Lu with respect to half-life, beta energy and chemical properties. However, 161Tb also emits a significant amount of conversion and Auger electrons. Greater therapeutic effect can therefore be expected in comparison to 177Lu. It also emits low-energy photons that are useful for gamma camera imaging. The 160Gd(n,γ)161Gd→161Tb production route was used to produce 161Tb by neutron irradiation of massive 160Gd targets (up to 40 mg) in nuclear reactors. A semiautomated procedure based on cation exchange chromatography was developed and applied to isolate no carrier added (n.c.a.) 161Tb from the bulk of the 160Gd target and from its stable decay product 161Dy. 161Tb was used for radiolabeling DOTA-Tyr3-octreotate; the radiolabeling profile was compared to the commercially available n.c.a. 177Lu. A 161Tb Derenzo phantom was imaged using a small-animal single-photon emission computed tomography camera. Up to 15 GBq of 161Tb was produced by long-term irradiation of Gd targets. Using a cation exchange resin, we obtained 80%–90% of the available 161Tb with high specific activity, radionuclide and chemical purity and in quantities sufficient for therapeutic applications. The 161Tb obtained was of the quality required to prepare 161Tb–DOTA-Tyr3-octreotate. We were able to produce 161Tb in n.c.a. form by irradiating highly enriched 160Gd targets; it can be obtained in the quantity and quality required for the preparation of 161Tb-labeled therapeutic agents.