793 resultados para lens array
Resumo:
Candidaemia is the fourth most common cause of bloodstream infection, with a high mortality rate of up to 40%. Identification of host genetic factors that confer susceptibility to candidaemia may aid in designing adjunctive immunotherapeutic strategies. Here we hypothesize that variation in immune genes may predispose to candidaemia. We analyse 118,989 single-nucleotide polymorphisms (SNPs) across 186 loci known to be associated with immune-mediated diseases in the largest candidaemia cohort to date of 217 patients of European ancestry and a group of 11,920 controls. We validate the significant associations by comparison with a disease-matched control group. We observe significant association between candidaemia and SNPs in the CD58 (P = 1.97 × 10(-11); odds ratio (OR) = 4.68), LCE4A-C1orf68 (P = 1.98 × 10(-10); OR = 4.25) and TAGAP (P = 1.84 × 10(-8); OR = 2.96) loci. Individuals carrying two or more risk alleles have an increased risk for candidaemia of 19.4-fold compared with individuals carrying no risk allele. We identify three novel genetic risk factors for candidaemia, which we subsequently validate for their role in antifungal host defence.
Resumo:
In this paper we analyze the persistence of aggregate real exchange rates (RERs) for a group of EU-15 countries by using sectoral data. The tight relation between aggregate and sectoral persistence recently investigated by Mayoral (2008) allows us to decompose aggregate RER persistence into the persistence of its different subcomponents. We show that the distribution of sectoral persistence is highly heterogeneous and very skewed to the right, and that a limited number of sectors are responsible for the high levels of persistence observed at the aggregate level. We use quantile regression to investigate whether the traditional theories proposed to account for the slow reversion to parity (lack of arbitrage due to nontradibilities or imperfect competition and price stickiness) are able to explain the behavior of the upper quantiles of sectoral persistence. We conclude that pricing to market in the intermediate goods sector together with price stickiness have more explanatory power than variables related to the tradability of the goods or their inputs.
Resumo:
Aquest projecte es centra en el disseny d’una antena microstrip per a GNSS. Una antena per a GNSS ha de tenir adaptació de impedància d’entrada i polarització circular a dretes, com a principals especificacions, en el rang de 1.15-1.6 GHz. El tipus d’alimentació d’una antena microstrip amb el major ample de banda d’adaptació és l’alimentació mitjançant acoblament per apertura. Si a l’antena s’introdueixen dos apertures de forma ortogonal, alimentades amb un desfasament de 90º entre elles, s’aconsegueix polarització circular. L’opció de separar les apertures redueix la transferència de potència entre elles, i disminueix el guany de polarització creuada. La xarxa d’alimentació dissenyada és un divisor de Wilkinson amb una línia de λ/4 a la freqüència central, encara que el desfasament als extrems de la banda no sigui de 90º. Com a xarxa d’alimentació es va provar un hibrid de 90º, però l’elevat valor del paràmetre S21 de l’antena impossibilita l’adaptació a l’entrada del hibrid.
Resumo:
Genetic determinants of blood pressure are poorly defined. We undertook a large-scale, gene-centric analysis to identify loci and pathways associated with ambulatory systolic and diastolic blood pressure. We measured 24-hour ambulatory blood pressure in 2020 individuals from 520 white European nuclear families (the Genetic Regulation of Arterial Pressure of Humans in the Community Study) and genotyped their DNA using the Illumina HumanCVD BeadChip array, which contains ≈50 000 single nucleotide polymorphisms in >2000 cardiovascular candidate loci. We found a strong association between rs13306560 polymorphism in the promoter region of MTHFR and CLCN6 and mean 24-hour diastolic blood pressure; each minor allele copy of rs13306560 was associated with 2.6 mm Hg lower mean 24-hour diastolic blood pressure (P=1.2×10(-8)). rs13306560 was also associated with clinic diastolic blood pressure in a combined analysis of 8129 subjects from the Genetic Regulation of Arterial Pressure of Humans in the Community Study, the CoLaus Study, and the Silesian Cardiovascular Study (P=5.4×10(-6)). Additional analysis of associations between variants in gene ontology-defined pathways and mean 24-hour blood pressure in the Genetic Regulation of Arterial Pressure of Humans in the Community Study showed that cell survival control signaling cascades could play a role in blood pressure regulation. There was also a significant overrepresentation of rare variants (minor allele frequency: <0.05) among polymorphisms showing at least nominal association with mean 24-hour blood pressure indicating that a considerable proportion of its heritability may be explained by uncommon alleles. Through a large-scale gene-centric analysis of ambulatory blood pressure, we identified an association of a novel variant at the MTHFR/CLNC6 locus with diastolic blood pressure and provided new insights into the genetic architecture of blood pressure.
Resumo:
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.
Resumo:
The aim of the work was to investigate the pattern of chemoreceptor sensilla in adults and fifth stage nymphs of Rhodnius prolixus, R. neglectus, Triatoma infestans and T. sordida in order to study differences and similarities between genera and species. Three types of sensilla were analyzed by light microscopy: thin-walled trichoidea, thick-walled trichoidea and basiconica. The number of sensilla of each three types were counted. The length of the antennal segments were also used as a variable for the analysis. The statistical analysis showed that the number of these antennal chemoreceptors had significant differences between species and between adults and nymphs of each species. Discriminant analysis separates incompletely the fifth stage nymphs of the four species and showed similarity between them. Discriminant analysis performed with 12 variables of the antennae, allowed a complete separation of the adults of the four species.
Resumo:
Background/Aims: To evaluate multifocal intraocular lens (MIOL) implantation in children. Methods: This is a retrospective study evaluating refractive, visual and safety results of MIOL in pediatric cataract surgery. Average follow-up was 25.73 ± 10.5 months. Surgery included 12 o'clock clear corneal incision, anterior capsulorhexis, lens material aspiration and MIOL implantation (SN6AD3; Alcon). Results: We included 34 cataract eyes of 26 pediatric patients aged 2-15 years, of which 14 (54%) were unilateral. Best near visual acuity (BNVA) and best distance visual acuity (BDVA) improved significantly in 100% of eyes (p = 0.0001). BDVA was above 0.8 in 31.25% (5/16) of bilateral cases. Significant stereopsis improvement was observed postoperatively in bilateral cases only (p = 0.01). Conclusion: MIOL implantation is a safe alternative to monofocal pseudophakia for pediatric cataract with a very low complication rate. Significant BNVA, BDVA and stereopsis improvement can be achieved, particularly in bilateral cases. Message: This study shows significant BDVA, BNVA and stereopsis improvement, especially in bilateral cases, after MIOL implantation for pediatric cataracts. © 2013 S. Karger AG, Basel.
Resumo:
Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.
Resumo:
The advent and application of high-resolution array-based comparative genome hybridization (array CGH) has led to the detection of large numbers of copy number variants (CNVs) in patients with developmental delay and/or multiple congenital anomalies as well as in healthy individuals. The notion that CNVs are also abundantly present in the normal population challenges the interpretation of the clinical significance of detected CNVs in patients. In this review we will illustrate a general clinical workflow based on our own experience that can be used in routine diagnostics for the interpretation of CNVs.
Resumo:
Structural genomic abnormalities play a key role in the pathogenesis of human disorders and represent one of the first causes of mental impairment, complex syndromes and tumors. In order to detect these chromosomal abnormalities, many methodologies have been developed with limits. The new ARRAY based Comparative Genomic Hybridization (ARRAY CGH) is a revolutionary approach which allows to characterize very small genetic abnormalities undetectable by the standard approaches and in the absence of any associated clinical information. The aim of this article is to describe why the application of a new array CGH methodology is necessary in the etiological search for genetic diseases, what the limits of the standard approaches are and to whom arrayCGH analyses can be applied in a pediatric environment. Examples of our practice will be presented.
Resumo:
Aquest document de treball mira d'establir un nou camp d'investigació a la cruïlla entre els fluxos de migració i d'informació i comunicació. Hi ha diversos factors que fan que valgui la pena adoptar aquesta perspectiva. El punt central és que la migració internacional contemporània és incrustada en la dinàmica de la societat de la informació, seguint models comuns i dinàmiques interconnectades. Per consegüent, s'està començant a identificar els fluxos d'informació com a qüestions clau en les polítiques de migració. A més, hi ha una manca de coneixement empíric en el disseny de xarxes d'informació i l'ús de les tecnologies d'informació i comunicació en contextos migratoris. Aquest document de treball també mira de ser una font d'hipòtesis per a investigacions posteriors.
Resumo:
Chemokines recruit and activate leukocytes, assisting granuloma formation. Herein, we evaluated plasma chemokines in patients with active tuberculosis (ATB) and after completing treatment (TTB) and compared them to BCG-vaccinated healthy controls (HC). Levels of chemokines were measured by cytometric bead array. Levels of CXCL8, CXCL9 and CXCL10 were higher in ATB patients compared to HC, but they decreased in TTB. Levels of CCL2 and CCL5 in ATB patients were similar to those observed in HC. Thus, the high levels of CXC-chemokines detected during ATB, which can modulate the trafficking of immune cells from the periphery to the site of infection, were reversed by anti-mycobacterial treatment.
Resumo:
When unmanned underwater vehicles (UUVs) perform missions near the ocean floor, optical sensors can be used to improve local navigation. Video mosaics allow to efficiently process the images acquired by the vehicle, and also to obtain position estimates. We discuss in this paper the role of lens distortions in this context, proving that degenerate mosaics have their origin not only in the selected motion model or in registration errors, but also in the cumulative effect of radial distortion residuals. Additionally, we present results on the accuracy of different feature-based approaches for self-correction of lens distortions that may guide the choice of appropriate techniques for correcting distortions
Resumo:
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.