970 resultados para intraaortic balloon pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMTo assess the double-balloon enteroscopy (DBE) role in malignant small bowel tumors (MSBT). METHODS This is a retrospective descriptive study performed in a single center. All consecutive patients who underwent a DBE with final diagnosis of a malignant neoplasm from 2004 to 2014 in our referral center were included. Patient demographic and clinical pathological characteristics were recorded and reviewed. MSBT diagnosis was achieved either by DBE directed biopsy with multiple tissue sampling, endoscopic findings or histological analysis of surgical specimen. We have analyzed double-balloon enteroscopy impact in outcome and clinical course of these patients. RESULTS Of 627 patients, 28 (4.5%) (mean age = 60 ± 17.3 years) underwent 30 procedures (25 anterograde, 5 retrograde) and were diagnosed of a malignant tumor. Patients presented with obscure gastrointestinal bleeding (n = 19, 67.9%), occlusion syndrome (n = 7, 25%) and diarrhea (n = 1, 3.6%). They were diagnosed by DBE biopsy (n = 18, 64.3%), histological analysis of surgical specimen (n = 7, 25%) and unequivocal endoscopic findings (n = 2, 7.1%). Gastrointestinal stromal tumor (n = 8, 28.6%), adenocarcinoma (n = 7, 25%), lymphoma (n = 4, 14.3%), neuroendocrine tumor (n = 4, 14.3%), metastatic (n = 3, 10.7%) and Kaposi sarcoma (n = 1, 3.6%) were identified. DBE modified outcome in 7 cases (25%), delaying or avoiding emergency surgery (n = 3), modifying surgery approach (n = 2) and indicating emergency SB partial resection instead of elective approach (n = 2). CONCLUSION DBE may be critical in the management of MSBT providing additional information that may be decisive in the clinical course of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: High-grade evidence is lacking for most therapeutic decisions in Crohn's disease. Appropriateness criteria were developed for upper gastro-intestinal, extra-intestinal manifestations and drug safety during conception, pregnancy and breastfeeding in patients with Crohn's disease, to assist the physician in clinical decision making. Methods: The European Panel on the Appropriateness of Crohn's Disease Therapy (EPACT II), a multidisciplinary international European expert panel, rated clinical scenarios based on evidence from the published literature and panelists' own clinical expertise. Median ratings (on a 9-point scale) were stratified into three categories: appropriate (7-9), uncertain (4-6 with or without disagreement) and inappropriate (1-3). Experts were also asked to rank appropriate medications by priority. Results: Proton pump inhibitors, steroids, azathioprine/6-mercaptopurine and infliximab are appropriate for upper gastro-duodenal Crohn's disease; for stenosis, endoscopic balloon dilation is the first-tine therapy, although surgery is also appropriate. Ursodeoxycholic acid is the only appropriate treatment for primary sclerosing cholangitis. Infliximab is appropriate for Pyoderma gangrenosum, ankylosing spondylitis and uveitis, steroids for Pyoderma gangrenosum and ankylosing spondylitis, adalimumab for Pyoderma gangrenosum and ankylosing spondylitis, cyclosporine-A/tacrolimus for Pyoderma gangrenosum. Mesalamine, sulfasalazine, prednisone, azathioprine/6-mercaptopurine, ciprofloxacin, and probiotics, may be administered safety during pregnancy or for patients wishing to conceive, with the exception that mate patients considering conception should avoid sulfasalazine. Metronidazol is considered safe in the 2nd and 3rd trimesters whereas infliximab is rated safe in the 1st trimester but uncertain in the 2nd and 3rd trimesters. Methotrexate is always contraindicated at conception, during pregnancy or during breastfeeding, due to its known teratogenicity. Mesalamine, prednisone, probiotics and infliximab are considered safe during breastfeeding. Conclusion: EPACT II recommendations are freely available online (www.epact.ch). The validity of these criteria should now be tested by prospective evaluation. (C) 2009 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative research that aimed to identify the mean total cost (MTC) of connecting, maintaining and disconnecting patient-controlled analgesia pump (PCA) in the management of pain. The non-probabilistic sample corresponded to the observation of 81 procedures in 17 units of the Central Institute of the Clinics Hospital, Faculty of Medicine, University of Sao Paulo. We calculated the MTC multiplying by the time spent by nurses at a unit cost of direct labor, adding the cost of materials and medications/solutions. The MTC of connecting was R$ 107.91; maintenance R$ 110.55 and disconnecting R$ 4.94. The results found will subsidize discussions about the need to transfer money from the Unified Health System to hospitals units that perform this technique of analgesic therapy and it will contribute to the cost management aimed at making efficient and effective decision-making in the allocation of available resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME : Actuellement la brachythérapie endovasculaire reste le seul traitement efficace pour la resténose intrastent. Malgré ceci, la limitation majeure de cette technique est la resténose aux extrémités du stent (effet de bord) due à une couverture incomplète par la source radioactive (geographical miss). Le ballon coupant et qui ne glisse pas pourrait limiter le barotraumatisme engendré par la dilatation et qui avec la diminution de la radiation aux extrémités de la source radioactive, est à la base du geographical miss. Cette étude prospective a pour but d'examiner l'efficacité du traitement de la resténose intrastent par la combinaison d'angioplastie avec cutting ballon et β - irradiation. Le registre « Radiation in Europe NOvoste » (RENO) inclut tous les patients traités par β - irradiation coronaire avec le système Beta-CathTM System (Novoste Corporation, Brussels, Belgium) n'ayant pas été inclus dans une autre étude randomisée. Un premier sous-groupe de ces patients (groupe 1, n=166), représente les patients traités par cutting ballon et β - irradiation intra coronaire. Ce groupe a été défini d'une manière prospective et les résultats cliniques à 6 mois ont été comparés par rapport aux autres patients qui ont reçu un traitement par dilatation coronaire conventionnelle et β - irradiation (groupe 2, n=712). A 6 mois de suivi, on a retrouvé une différence significative entre les 2 groupes par rapport à la nécessité d'une nouvelle revascularisation du vaisseau préalablement traité (10,2% de récidive dans le groupe 1 contre 16,6 % dans le groupe 2 , p=0,04). Le nombre d'événements cardiaques majeurs (mortalité, infarctus du myocarde et revascularisation) a également été diminué de manière significative (10,8% contre 19,2% ; />=0,01). Cette observation a été confirmée par une analyse multivariée qui indique un risque diminué pour les événements cardiaques majeurs à 6 mois, (rapport de côtes : 0,49 ; intervalle de confiance 0,27-0,88 ; p=0,02). Comparé à l'angioplastie coronarienne avec ballon conventionnel, l'utilisation de cutting ballon avant la β - irradiation dans le traitement de la resténose intrastent démontre une meilleure évolution clinique à 6 mois. ABSTRACT: At present, vascular brachytherapy is the only efficient therapy for in-stent restenosis. Nevertheless edge restenosis often relat¬ed to geographical miss has been identified as a major limitation of the technique. The non-slippery cutting balloon has the potential to limit vascular barotraumas which, together with low-dose irradiation at both ends of the radioactive source, are the prerequisite for geographical miss. This prospective study aimed to examine the efficacy of combining cut¬ting balloon angioplasty and brachytherapy for in-stent restenosis. The Radiation in Europe NOvoste (RENO) registry prospectively tracked all patients who had been treated by coronary β-radiation with the Beta-CathTM System (Novoste Corporation. Brussels, Belgium) but were not included in a randomized radiation trial, A subgroup of patients with in-stent restenosis treated by cutting balloon angioplasty and coronary β-radiation (group 1, n = 166) was prospectively defined, and clinical outcomes of patients at 6 months were compared with those of patients treated by conventional angioplasty and coronary β -radiation (group 2, n = 712). At 6-month follow-up, there was a significant difference between groups 1 and 2 in- target vessel revascularization (10.2% versus 16.6% respectively; p = 0.04) and in the incidence of major adverse clinical events (MACE) including, death, myocardial infarction, and revascularization (10.8% versus 19.2%; p= 0.01). This observation was confirmed by a multivariate analysis indicating a. lower risk for MACE at 6 months (odds ratio: 0.49; confidence intervals: 0.27-0.88; p = 0.02). Compared to conventional angioplasty, cutting balloon angio¬plasty prior to coronary beta-radiation with the Beta-CathTM System seems to improve the 6-month clinical outcome in patients with in-stent restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The objective of this article is to describe the development of an anatomically accurate simulator in order to aid the training of a perinatal team in the insertion and removal of a fetal endoscopic tracheal occlusion (FETO) balloon in the management of prenatally diagnosed congenital diaphragmatic hernia. Methods An experienced perinatal team collaborated with a medical sculptor to design a fetal model for the FETO procedure. Measurements derived from 28-week fetal magnetic resonance imaging were used in the development of an anatomically precise simulated airway within a silicone rubber preterm fetal model. Clinician feedback was then used to guide multiple iterations of the model with serial improvements in the anatomic accuracy of the simulator airway. Results An appropriately sized preterm fetal mannequin with a high-fidelity airway was developed. The team used this model to develop surgical skills with balloon insertion, and removal, and to prepare the team for an integrated response to unanticipated delivery with the FETO balloon still in situ. Conclusions This fetal mannequin aided in the ability of a fetal therapy unit to offer the FETO procedure at their center for the first time. This model may be of benefit to other perinatal centers planning to offer this procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Brownian pump of particles powered by a stochastic flashing ratchet mechanism is studied. The pumping device is embedded in a finite region and bounded by particle reservoirs. In the steady state, we exactly calculate the spatial density profile, the concentration ratio between both reservoirs and the particle flux. We propose a simulation framework for the consistent evaluation of such observable quantities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this experiment is to establish a continuous postmortem circulation in the vascular system of porcine lungs and to evaluate the pulmonary distribution of the perfusate. This research is performed in the bigger scope of a revascularization project of Thiel embalmed specimens. This technique enables teaching anatomy, practicing surgical procedures and doing research under lifelike circumstances. METHODS: After cannulation of the pulmonary trunk and the left atrium, the vascular system was flushed with paraffinum perliquidum (PP) through a heart-lung machine. A continuous circulation was then established using red PP, during which perfusion parameters were measured. The distribution of contrast-containing PP in the pulmonary circulation was visualized on computed tomography. Finally, the amount of leak from the vascular system was calculated. RESULTS: A reperfusion of the vascular system was initiated for 37 min. The flow rate ranged between 80 and 130 ml/min throughout the experiment with acceptable perfusion pressures (range: 37-78 mm Hg). Computed tomography imaging and 3D reconstruction revealed a diffuse vascular distribution of PP and a decreasing vascularization ratio in cranial direction. A self-limiting leak (i.e. 66.8% of the circulating volume) towards the tracheobronchial tree due to vessel rupture was also measured. CONCLUSIONS: PP enables circulation in an isolated porcine lung model with an acceptable pressure-flow relationship resulting in an excellent recruitment of the vascular system. Despite these promising results, rupture of vessel walls may cause leaks. Further exploration of the perfusion capacities of PP in other organs is necessary. Eventually, this could lead to the development of reperfused Thiel embalmed human bodies, which have several applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of symptomatic pharyngeal and esophageal strictures requires endoscopic dilatation. The Savary-Gilliard bougienage was developed by our department and has been used since 1980 for this purpose. We report our experience using this technique. The records of patients seen from January 1, 1963 to December 31, 2005, who had pharyngeal and esophageal strictures needing dilatation, were reviewed. The prevalence of different etiologies, and the incidence of complications using the Savary-Gilliard dilators were assessed. Efficiency of dilatation was assessed over a 17-year segment of this period, using number of dilatations and time intervals between dilatations until resolution of symptoms as outcome measures. Of the 2,652 pharyngeal and esophageal strictures reviewed, 90% were of organic origin (45% benign and 55% malignant stenoses), and 10% were of functional etiology. The most common etiologies were peptic strictures before the era of proton pump inhibitors, and postoperative anastomotic strictures thereafter. A total of 1,862 dilatations using the Savary-Gilliard technique were analyzed. Complication and mortality rates were 0.18 and 0.09% for benign and 4.58 and 0.81% for malignant etiologies, respectively. The number of dilatations per stricture and the time interval between different sessions were dependent on the type of strictures, varying from 1 to 23 dilatations and 7 days to 16 years, respectively. Pharyngeal and esophageal dilatations using the Savary-Gilliard technique were safe when used together with fluoroscopy. Overall, the efficiency of the dilatation procedure was good, but some types of strictures (e.g., caustic, post-surgical and/or post radiotherapy) were refractory to treatment and required repeated dilatations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Introduction: Les inhibiteurs de la pompe à protons sont actuellement considérés comme les médicaments de choix pour le traitement des affections peptiques comme l'ulcère gastroduodénal et l'oesophagite de reflux. La rapidité, ainsi que le degré d'inhibition de la sécrétion gastrique acide sont importants pour le contrôle optimal des symptômes ainsi que pour le traitement de ces affections. But : Le but principal de cette étude a été de comparer, chez les sujets asymptomatiques non infectés par H. pylori, par pH-métrie intragastrique de 24 heures, la rapidité et la durée de l'action antisécrétoire de doses uniques de rabéprazole 20 mg, d'oméprazole capsule 20 mg, d'oméprazole en comprimé MUPS (« Multiple Unit Pellet System ») 20 mg, de pantoprazole 40 mg et de lansoprazole 30 mg, respectivement. Matériel et méthodes : Cette étude, effectuée en double aveugle et randomisée, a été conduite de manière croisée chez 18 sujets H. pylori-négatifs. Une pH-métrie de 24 heures a été effectuée le jour de l'administration du médicament (dose unique de rabéprazole 20 mg, de lansoprazole 30mg, de pantoprazole 40 mg, d'oméprazole capsule 20 mg, d'oméprazole MUPS comprimé 20mg, ou de placebo). Résultats : Le pH intragastrique médian (3.4 vs. 2.9, 2.2, 1.9 et 1.8, respectivement; p≤ 0.03) et le temps avec un pH supérieur à 4 pendant les 24 heures suivant la prise du médicament (8.0 heures vs. 7.4, 4.9, 2.9, et 3.0, respectivement; p≤ 0.003) ont été statistiquement plus élevés avec le rabéprazole qu'avec le lansoprazole, le pantoprazole, l'oméprazole capsule, l'oméprazole comprimé MUPS, ou le placebo. Les valeurs du pH pendant les périodes diurnes et nocturnes étaient plus hautes avec le rabeprazole et le lansoprazole qu'avec le pantoprazole, l'oméprazole capsule, et l'oméprazole comprimé MUPS (p≤0.04). Conclusion : Le rabéprazole s'est montré le plus efficace de tous les inhibiteurs de pompe à protons étudiés durant le premier jour de l'administration du médicament. SUMMARY Background: Rapid and consistent acid suppression on the first day of dosing may be important in treating acid-related disorders. Aim: To compare the antisecretory activity and onset of action of single doses of rabeprazole, lansoprazole, pantoprazole, omeprazole capsule, omeprazole multiple unit pellet system (MUPS) tablet and placebo in healthy Helicobacter pylori-negative subjects. Methods: This cross-over, double-blind, randomized study was performed in 18 H. pylori-negative subjects. Twenty-four-hour intragastric pH monitoring was performed on the day of treatment (once-daily dose of rabeprazole 20 mg, lansoprazole 30 mg, pantoprazole 40 mg, omeprazole capsule 20 mg, omeprazole MUPS tablet 20 mg or placebo). Results: The intragastric pH (3.4) and time at pH > 4 during the 24 h post-dose (8.0 h) were significantly greater with rabeprazole than with lansoprazole, pantoprazole, omeprazole capsule, omeprazole MUPS tablet or placebo (P ≤ 0.04 for rabeprazole vs. the others). Daytime and night-time pH values were higher with rabeprazole and lansoprazole than with pantoprazole, omeprazole capsule and omeprazole MUPS tablet (P ≤ 0.04). Conclusion: Rabeprazole was the most potent acid inhibitor of all the proton pump inhibitors tested during the first day of dosing.