938 resultados para inter-area oscillation frequency


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study we used a combination of patch clamping and fast confocal Ca2+ imaging to examine the effects of activators of the nitric oxide (NO)/cGMP pathway on pacemaker activity in freshly dispersed ICC from the rabbit urethra, using the amphotericin B perforated patch configuration of the patch-clamp technique. The nitric oxide donor, DEA-NO, the soluble guanylyl cyclase activator YC-1 and the membrane-permeant analogue of cGMP, 8-Br-cGMP inhibited spontaneous transient depolarizations (STDs) and spontaneous transient inward currents (STICs) recorded under current-clamp and voltage-clamp conditions, respectively. Caffeine-evoked Cl- currents were unaltered in the presence of SP-8-Br-PET-cGMPs, suggesting that activation of the cGMP/PKG pathway does not block Cl- channels directly or interfere with Ca2+ release via ryanodine receptors (RyR). However, noradrenaline-evoked Cl- currents were attenuated by SP-8-Br-PET-cGMPs, suggesting that activation of cGMP-dependent protein kinase (PKG) may modulate release of Ca2+ via IP3 receptors (IP3R). When urethral interstitial cells (ICC) were loaded with Fluo4-AM (2 microm), and viewed with a confocal microscope, they fired regular propagating Ca2+ waves, which originated in one or more regions of the cell. Application of DEA-NO or other activators of the cGMP/PKG pathway did not significantly affect the oscillation frequency of these cells, but did significantly reduce their spatial spread. These effects were mimicked by the IP3R blocker, 2-APB (100 microm). These data suggest that NO donors and activators of the cGMP pathway inhibit electrical activity of urethral ICC by reducing the spatial spread of Ca2+ waves, rather than decreasing wave frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements were made (using fast confocal microscopy) of intracellular Ca2+ levels in fluo-4 loaded interstitial cells isolated from the rabbit urethra. These cells exhibited regular Ca2+ oscillations which were associated with spontaneous transient inward currents recorded under voltage clamp. Interference with D-myo-inositol 1,4,5-trisphosphate (IP3) induced Ca2+ release using 100 microm 2-aminoethoxydiphenyl borate, and the phospholipase C (PLC) inhibitors 2-nitro-4-carboxyphenyl N,N-diphenylcarbamate and U73122 decreased the amplitude of spontaneous oscillations but did not abolish them. However, oscillations were abolished when ryanodine receptors were blocked with tetracaine or ryanodine. Oscillations ceased in the absence of external Ca2+, and frequency was directly proportional to the external Ca2+ concentration. Frequency of Ca2+ oscillation was reduced by SKF-96365, but not by nifedipine. Lanthanum and cadmium completely blocked oscillations. These results suggest that Ca2+ oscillations in isolated rabbit urethral interstitial cells are initiated by Ca2+ release from ryanodine-sensitive intracellular stores, that oscillation frequency is very sensitive to the external Ca2+ concentration and that conversion of the primary oscillation to a propagated Ca2+ wave depends upon IP3-induced Ca2+ release.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oscillatory flows of a choked underexpanded supersonic impinging jet issuing from a convergent nozzle have been computed using the axisymmetric unsteady Navier–Stokes system. This paper focuses on the oscillatory flow features associated with the variation of the nozzle-to-plate distance and nozzle pressure ratio. Frequencies of the surface pressure oscillation and flow structural changes from computational results have been analyzed. Staging behaviour of the oscillation frequency has been observed for both cases of nozzle-to-plate distance variation and pressure ratio variation. However, the staging behavior for each case exhibits different features. These two distinct staging behaviors of the oscillation frequency are found to correlate well if the frequency and the distance are normalized by the length of the shock cell. It is further found that the staging behaviour is strongly correlated with the change of the pressure wave pattern in the jet shear layer, but not with the shock cell structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rapid growth of wind generation in many European countries is pushing power systems into
uncharted territory. As additional wind generators are installed, the changing generation mix may
impact on power system stability. This paper adopts the New England 39 bus system as a test
system for transient stability analysis. Thermal generator models are based on a likely future plant
mix for existing systems, while varying capacities of fixed-speed induction generators (FSIG) and
doubly-fed induction generators (DFIG) are considered. The main emphasis here has been placed
on the impact of wind technology mix on inter-area oscillations following transient grid
disturbances. In addition, both rotor angle stability and transient voltage stability are examined, and
results are compared with current grid code requirements and standards. Results have shown that
FSIGs can reduce tie-line oscillations and improve damping following a transient disturbance, but
they also cause voltage stability and rotor angle stability problems at high wind penetrations. In
contrast, DFIGs can improve both voltage and rotor angle stability, but their power output
noticeably oscillates during disturbances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study reports the performance of an Archimedean spiral antenna, which exhibits unidirectional circularly polarized radiation patterns with a peak gain >8 dBic in the lower (2.4–2.485 GHz) and upper (5.15–5.35 and 5.725–5.875 GHz) Wireless local area network frequency bands. The required backlobe suppression and impedance match are obtained by placing a multiresonant high impedance surface (HIS) in close proximity to the radiating aperture. Simulated and measured radiation patterns are shown at the center frequency of all three channels and a comparison of the key performance metrics is made with free space and metal backed antenna arrangements to demonstrate the enhancements which are attributed to the HIS reflector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is prompted by the widespread acceptance that the rates of inter-county and inter-state migration have been falling in the USA and sets itself the task of examining whether this decline in migration intensities is also the case in the UK. It uses annual inter-area migration matrices available for England and Wales since the 1970s by broad age group. The main methodological challenge, arising from changes in the geography of health areas for which the inter-area flows are given, is addressed by adopting the lowest common denominator of 80 areas. Care is also taken to allow for the effect of economic cycles in producing short-term fluctuations on migration rates and to isolate the effect of a sharp rise in rates for 16-24 year olds in the 1990s, which is presumed to be related to the expansion of higher education. The findings suggest that, unlike for the USA, there has not been a substantial decline in the intensity of internal migration between the first two decades of the study period and the second two. If there has been any major decline in the intensity of address changing in England and Wales, it can only be for the within-area moves that this time series does not cover. This latter possibility is examined in a companion paper using a very different data set (Champion and Shuttleworth, 2016).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke volume oscillations but not spectral frequency variability stroke volume measures can be used to estimate the breathing frequency. This study investigated with the same recordings whether heart period oscillations or spectral heart rate variability measures could function as estimators of breathing frequency. Continuous 270 s cardiovascular recordings were obtained from 22 healthy adult volunteers in the supine and upright postures. Breathing was recorded simultaneously. Breathing frequency and heart period oscillation frequency were calculated manually, while heart rate variability spectral maximums were obtained using heart rate variability software. These estimates were compared to the breathing frequency using the Bland–Altman agreement procedure. Estimates were required to be \±10% (95% levels of agreement). The 95% levels of agreement measures for the heart period oscillation frequency (supine: -27.7 to 52.0%, upright: -37.8 to 45.9%) and the heart rate variability spectral maximum estimates (supine: -48.7 to 26.5% and -56.4 to 62.7%, upright: -37.8 to 39.3%) exceeded 10%. Multiple heart period oscillations were observed to occur during breathing cycles. Both respiratory and non-respiratory sinus arrhythmia was observed amongst healthy adults. This observation at least partly explains why heart period parameters and heart rate variability parameters are not reliable estimators of breathing frequency. In determining the validity of spectral heart rate variability measurements we suggest that it is the position of the spectral peaks and not the breathing

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dispersal polymorphism may exist in emigrants from cyclic populations of Microtus '~nnsylvanicus biasing trap-revealed movements of unenclosed animals in favour of sedentary or colonizing individuals. The dispersal tendency of emigrants from an enclosed population was investigated by releasing animals via tubes into one of two adjacent enclosures, one vacant and one inhabited. Individuals from the enclosed population were monitored for age, sex, weight and electrophoretically detectable serum transferrin genotype in an intensive live-trapping program. In 1973 the minimum number alive in the introduced enclosed study population reached approximately l67/ha when breeding stopped in October. In 1974 intensive breeding increased the population density to 333/ha by mid-July when a long decline in numbers and breeding intensity began without an intervening plateau. An adjacent unenclosed area had a much lower density and longer breeding season in 1974. The growth rate of young males in the enclosed population tended to be lowest during the decline period in 1974. Survival of the enclosed population was high throughout but was lowest during the decline phase in both sexes, especially males. Low transferrin heterozygote survival during the decline coincided with a significant heterozygote deficiency in females whereas in males genotype frequencies did not depart from Hardy-Weinberg equilibrium values throughout th.e study. Twenty-nine suitable ani.mals were released during the decline in five periods from July to November 1974. The proportions of males and transferrin heterozygotes in the released graun were generally greater than in the source population~ In the test enclosures 21% of the released animals continued their movement through the vacant area while 41% (no significant difference) moved through the inhabited enclosure. In the vacant test area, females had a greater tendency than males to continue dispersal whereas no difference was noted in the inhabited area. Low frequency of captures in the tubes, predator disturbances and cold weather forced the termination of the study. The role of dispersal as a population regulating mechanism was further substantiated. The genetic differences between emigrant and resident animals lend support to Howard's hypothesis that a genetic polymorphism influences the tendency to disperse. Support is also given to Myers' and Krebs' contention that among dispersers an additional density dependent polymorphism influences the distance dispersed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Establecer la prevalencia de síntomas músculo esqueléticos, relacionados con las características demográficas y el área de trabajo, en empleados de una empresa de telecomunicaciones en Bogotá D.C., Colombia en el 2013. Metodología: Se realizó un estudio observacional descriptivo de corte transversal, en una empresa de telecomunicaciones de la cuidad de Bogotá en el 2013, con una población de 100 trabajadores del área técnica, comercial y administrativa. Se utilizó el Cuestionario Nórdico Estandarizado de síntomas músculo-esqueléticos1 y la Encuesta Nacional de Condiciones de Trabajo, del Instituto Nacional de Seguridad e Higiene en el Trabajo de España (INSHT). Resultados: La prevalencia de síntomas músculo-esqueléticos fue de 58%. El promedio de edad de la población que presentó síntomas fue 32.8 años. Respecto al área de trabajo el 44% pertenece al área técnica, el 32% al área comercial y el 24% al área administrativa. Se encontró mayor porcentaje de síntomas de columna lumbar en la población del área administrativa (p= 0.02), manos/muñecas (p= 0,001), hombros (p= 0.044) y cuello (p= 0.003), comparado con comerciales y técnicos, con una diferencia estadísticamente significativa. En el área técnica se encontró mayor porcentaje de síntomas en columna dorsal (p= 0.0052). Conclusiones: Se estableció una prevalencia de síntomas musculo esqueléticos similar a la reportada en la literatura nacional con poblaciones de características similares. Se pone en evidencia la presencia de síntomas musculo esqueléticos relacionados con el área de trabajo, principalmente con el área administrativa. El síntoma más frecuente se ubicó en columna lumbar. Se requiere de estudios posteriores con una muestra poblacional mayor y asociando factores de riesgo que permitan establecer causalidad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principles of operation of an experimental prototype instrument known as J-SCAN are described along with the derivation of formulae for the rapid calculation of normalized impedances; the structure of the instrument; relevant probe design parameters; digital quantization errors; and approaches for the optimization of single frequency operation. An eddy current probe is used As the inductance element of a passive tuned-circuit which is repeatedly excited with short impulses. Each impulse excites an oscillation which is subject to decay dependent upon the values of the tuned-circuit components: resistance, inductance and capacitance. Changing conditions under the probe that affect the resistance and inductance of this circuit will thus be detected through changes in the transient response. These changes in transient response, oscillation frequency and rate of decay, are digitized, and then normalized values for probe resistance and inductance changes are calculated immediately in a micro processor. This approach coupled with a minimum analogue processing and maximum of digital processing has advantages compared with the conventional approaches to eddy current instruments. In particular there are: the absence of an out of balance condition and the flexibility and stability of digital data processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brain activity can be measured non-invasively with functional imaging techniques. Each pixel in such an image represents a neural mass of about 105 to 107 neurons. Mean field models (MFMs) approximate their activity by averaging out neural variability while retaining salient underlying features, like neurotransmitter kinetics. However, MFMs incorporating the regional variability, realistic geometry and connectivity of cortex have so far appeared intractable. This lack of biological realism has led to a focus on gross temporal features of the EEG. We address these impediments and showcase a "proof of principle" forward prediction of co-registered EEG/fMRI for a full-size human cortex in a realistic head model with anatomical connectivity, see figure 1. MFMs usually assume homogeneous neural masses, isotropic long-range connectivity and simplistic signal expression to allow rapid computation with partial differential equations. But these approximations are insufficient in particular for the high spatial resolution obtained with fMRI, since different cortical areas vary in their architectonic and dynamical properties, have complex connectivity, and can contribute non-trivially to the measured signal. Our code instead supports the local variation of model parameters and freely chosen connectivity for many thousand triangulation nodes spanning a cortical surface extracted from structural MRI. This allows the introduction of realistic anatomical and physiological parameters for cortical areas and their connectivity, including both intra- and inter-area connections. Proper cortical folding and conduction through a realistic head model is then added to obtain accurate signal expression for a comparison to experimental data. To showcase the synergy of these computational developments, we predict simultaneously EEG and fMRI BOLD responses by adding an established model for neurovascular coupling and convolving "Balloon-Windkessel" hemodynamics. We also incorporate regional connectivity extracted from the CoCoMac database [1]. Importantly, these extensions can be easily adapted according to future insights and data. Furthermore, while our own simulation is based on one specific MFM [2], the computational framework is general and can be applied to models favored by the user. Finally, we provide a brief outlook on improving the integration of multi-modal imaging data through iterative fits of a single underlying MFM in this realistic simulation framework.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recurrence rate of flux transfer events (FTEs) observed near the dayside magnetopause is discussed. A survey of magnetopause observations by the ISEE satellites shows that the distribution of the intervals between FTE signatures has a mode value of 3 min, but is highly skewed, having upper and lower decile values of 1.5 min and 18.5 min, respectively. The mean value is found to be 8 min, consistent with previous surveys of magnetopause data. The recurrence of quasi-periodic events in the dayside auroral ionosphere is frequently used as evidence for an association with magnetopause FTEs, and the distribution of their repetition intervals should be matched to that presented here if such an association is to be confirmed. A survey of 1 year's 15-s data on the interplanetary magnetic field (IMF) suggests that the derived distribution could arise from fluctuations in the IMF Bz component, rather than from a natural oscillation frequency of the magnetosphere-ionosphere system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an automatic device for in situ and continuous monitoring of the ageing process occurring in natural and synthetic resins widely used in art and in the conservation and restoration of cultural artefacts. The results of tests carried out under accelerated ageing conditions are also presented. This easy-to-assemble palm-top device, essentially consists of oscillators based on quartz crystal resonators coated with films of the organic materials whose response to environmental stress is to be addressed. The device contains a microcontroller which selects at pre-defined time intervals the oscillators and records and stores their oscillation frequency. The ageing of the coatings, caused by the environmental stress and resulting in a shift in the oscillation frequency of the modified crystals, can be straightforwardly monitored in this way. The kinetics of this process reflects the level of risk damage associated with a specific microenvironment. In this case, natural and artificial resins, broadly employed in art and restoration of artistic and archaeological artefacts (dammar and Paraloid B72), were applied onto the crystals. The environmental stress was represented by visible and UV radiation, since the chosen materials are known to be photochemically active, to different extents. In the case of dammar, the results obtained are consistent with previous data obtained using a bench-top equipment by impedance analysis through discrete measurements and confirm that the ageing of this material is reflected in the gravimetric response of the modified quartz crystals. As for Paraloid B72, the outcome of the assays indicates that the resin is resistant to visible light, but is very sensitive to UV irradiation. The use of a continuous monitoring system, apart from being obviously more practical, is essential to identify short-term (i.e. reversible) events, like water vapour adsorption/desorption processes, and to highlight ageing trends or sudden changes of such trends. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents an wideband ring VCO for cognitive radio five-port based receivers. A three-stage differential topology using transmission gate was adopted in order to maintain wide and linear tuning range and a low phase-noise. Monte-Carlo analysis were performed for phase-shift response of individual stages, which is an important figure of merit in five-port works. It was observed a fairly linear correlation between control voltage and oscillation frequency in the range between 200 MHz and 1800 MHz. The VCO was preliminarily designed for IBM 130nm CMOS technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impurity interstitial atoms present in metals with BCC structure can diffuse in the metallic matrix by jumps to energetically equivalent crystallographic sites. Anelastic spectroscopy (internal friction) is based on the measurement of mechanical loss or internal friction as a function of temperature. Due to its selective and nondestructive nature, anelastic spectroscopy is well suited for the study of diffusion of interstitial elements in metals. Internal friction measurements were made using the torsion pendulum technique with oscillation frequency of a few Hz, temperature interval from 300 to 700 K, heating rate of about 1 K/min, and vacuum better than 10-5 mbar. The polycrystalline Nb and Ta samples used were supplied by Aldrich Inc. The results obtained showed thermally activated relaxation structures due to stress-induced ordering of oxygen atoms around the Nb (or Ta) atoms of the metallic matrix. The results were interpreted by three methods and led to activation enthalpy values for the diffusion of oxygen in Nb and Ta of 1.15 eV and 1.10 eV, respectively.