973 resultados para indoor air
Resumo:
Within-building spatial variability of indoor air quality may influence substantially the reliability of human exposure assessments based on single point samples, but have hitherto been little studied. To investigate and understand the within-building spatial variation of air pollutants, field measurements were conducted in a 7 level office building in Brisbane, Australia. The building consists of 3 sections (A side, Meddler and B side).
Resumo:
Polybrominated diphenyl ethers (PBDEs) are compounds that are used as flame retardants. Human exposure is suggested to be via food, dust and air. An assessment of PBDE exposure via indoor environments using samples of air, dust and surface wipes from eight sites in South East Queensland, Australia was conducted. For indoor air, ΣPBDEs ranged from 0.5 -179 pg/m3 for homes and 15 - 487 pg/m3 for offices. In dust, ΣPBDEs ranged from 87 - 733 ng/g dust and 583 - 3070 ng/g dust in homes and offices, respectively. PBDEs were detected on 9 out of 10 surfaces sampled and ranged from non-detectable to 5985 pg/cm2. Overall, the congener profiles for air and dust were dominated by BDE-209. This study demonstrated that PBDEs are ubiquitous in the indoor environments of selected buildings in South East Queensland and suggest the need for detailed assessment of PBDE concentrations using more sites to further investigate the factors influencing PBDE exposure in Australia.
Resumo:
This project was conducted at Lithgow Correctional Centre (LCC), NSW, Australia. Air quality field measurements were conducted on two occasions (23-27 May 2012, and 3-8 December 2012), just before and six months after the introduction of smoke free buildings policies (28 May 2012) at the LCC, respectively. The main aims of this project were to: (1) investigate the indoor air quality; (2) quantify the level of exposure to environmental tobacco smoke (ETS); (3) identify the main indoor particle sources; (4) distinguish between PM2.5 / particle number from ETS, as opposed to other sources; and (5) provide recommendations for improving indoor air quality and/or minimising exposure at the LCC. The measurements were conducted in Unit 5.2A, Unit 5.2B, Unit 1.1 and Unit 3.1, together with personal exposure measurements, based on the following parameters: -Indoor and outdoor particle number (PN) concentration in the size range 0.005-3 µm -Indoor and outdoor PM2.5 particle mass concentration -Indoor and outdoor VOC concentrations -Personal particle number exposure levels (in the size range 0.01-0.3 µm) -Indoor and outdoor CO and CO2 concentrations, temperature and relative humidity In order to enhance the outcomes of this project, the indoor and outdoor particle number (PN) concentrations were measured by two additional instruments (CPC 3787) which were not listed in the original proposal.
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings
Resumo:
This study aimed to develop a multi-component model that can be used to maximise indoor environmental quality inside mechanically ventilated office buildings, while minimising energy usage. The integrated model, which was developed and validated from fieldwork data, was employed to assess the potential improvement of indoor air quality and energy saving under different ventilation conditions in typical air-conditioned office buildings in the subtropical city of Brisbane, Australia. When operating the ventilation system under predicted optimal conditions of indoor environmental quality and energy conservation and using outdoor air filtration, average indoor particle number (PN) concentration decreased by as much as 77%, while indoor CO2 concentration and energy consumption were not significantly different compared to the normal summer time operating conditions. Benefits of operating the system with this algorithm were most pronounced during the Brisbane’s mild winter. In terms of indoor air quality, average indoor PN and CO2 concentrations decreased by 48% and 24%, respectively, while potential energy savings due to free cooling went as high as 108% of the normal winter time operating conditions. The application of such a model to the operation of ventilation systems can help to significantly improve indoor air quality and energy conservation in air-conditioned office buildings.
Resumo:
There are three distinct categories of air environment to be considered in this chapter. These are as follows: (1) The “ambient” or general outdoors atmosphere to which the members of the population are exposed when they venture out of their homes or offices in industrial, urban or rural environments. (2) Indoor air environments, which occur in buildings such as homes, schools, restaurants, public hospitals and office buildings. This category does not cover factories or workplaces which are otherwise subjected to the provisions of various occupational health standards. (3) Workplace atmospheres, which occur in a variety of industries or factories and for which there are numerous atmospheric concentration limits (or exposure standards) promulgated by appropriate bodies or organisations. Since 2009 setting concentration limits for atmospheric contaminants has been administered by Safe Work Australia. A fourth category of air environment which falls outside this chapter is that which is related to upper atmospheric research, global atmospheric effects and concomitant areas of inquiry and/or debate. Such areas include “greenhouse” gas emissions, ozone depletion, and related matters of atmospheric chemistry and physics. This category is not referred to again in this chapter.
Resumo:
Indoor air quality is a critical factor in the classroom due to high people concentration in a unique space. Indoor air pollutant might increase the chance of both long and short-term health problems among students and staff, reduce the productivity of teachers and degrade the student’s learning environment and comfort. Adequate air distribution strategies may reduce risk of infection in classroom. So, the purpose of air distribution systems in a classroom is not only to maximize conditions for thermal comfort, but also to remove indoor contaminants. Natural ventilation has the potential to play a significant role in achieving improvements in IAQ. The present study compares the risk of airborne infection between Natural Ventilation (opening windows and doors) and a Split-System Air Conditioner in a university classroom. The Wells-Riley model was used to predict the risk of indoor airborne transmission of infectious diseases such as influenza, measles and tuberculosis. For each case, the air exchange rate was measured using a CO2 tracer gas technique. It was found that opening windows and doors provided an air exchange rate of 2.3 air changes/hour (ACH), while with the Split System it was 0.6 ACH. The risk of airborne infection ranged between 4.24 to 30.86 % when using the Natural Ventilation and between 8.99 to 43.19% when using the Split System. The difference of airborne infection risk between the Split System and the Natural Ventilation ranged from 47 to 56%. Opening windows and doors maximize Natural Ventilation so that the risk of airborne contagion is much lower than with Split System.
Resumo:
Muitos dos locais onde as atividades são realizadas nas academias de ginásticas são salas pequenas e fechadas com sistema de climatização artificial, freqüentados por um grande número de alunos realizando seus exercícios e profissionais auxiliando as atividades. Com isso, há uma intensa transpiração desses indivíduos, uma freqüente rotina de limpeza do piso e de equipamentos com pequenos intervalos, possibilitando a alterações da qualidade do ar indoor. O presente trabalho busca mostrar as tendências de variações nos valores das concentrações dos poluentes atmosféricos BTEX em ambiente indoor, especificamente na sala de spinning de uma academia de ginástica do Rio de Janeiro. Para o monitoramento da qualidade do ar foram utilizados cartuchos de carvão ativado SKC, acoplado a uma bomba KNF com vazão de 1l min. Para a extração de cada amostra foi feita a análise cromatográfica com cromatógrafo a gás modelo 6890 acoplado a um espectrômetro de massa modelo 5973 da marca Agilent. Foram analisadas 34 amostras coletadas na salas de spinning durante as aulas com atividades aeróbicas, o que intensificava a respiração dos indivíduos, possibilitando uma maior inalação destes COVs. Em contrapartida, também foram coletadas 5 amostras outdoor, 4 delas pareadas indoor/ outdoor para uma análise comparativa das concentrações destes poluentes. Dentre os compostos orgânicos voláteis analisados, o tolueno é o BTEX mais abundante obtido neste trabalho, representando 81% destes COVs indoor. Todas as amostras medidas em pares indoor/ outdoor tiveram concentrações maiores no interior, exceto para o benzeno no dia 3/12/2010. Simples atividades usualmente realizadas pelo homem, como a inserção de piso emborrachado, manutenção do sistema de climatização artificial, e limpeza podem alterar o ar indoor. As conclusões alcançadas após as medições das concentrações de BTEX foram de que o ar indoor estava mais poluído do que o outdoor. Este monitoramento da qualidade do ar indoor ainda é escasso no Brasil. Alguns esforços tem sido feito em relação a ambientes confinados como a Portaria n˚3523 do Ministério da Saúde, regulamentando o controle dos ambientes climatizados e a Resolução n˚9 da Agência Nacional de Vigilância Sanitária, além da Resolução CONAMA n ˚3 estabelecendo padrões de qualidade do ar para alguns compostos químicos, porém muitos compostos químicos ainda não são legislados ou não possuem a devida atenção, não sendo suficientes para contemplar a complexidade do assunto
Resumo:
IEECAS SKLLQG
Resumo:
The simultaneous heat and moisture transfer in the building envelope has an important influence on the indoor environment and the overall performance of buildings. In this paper, a model for predicting whole building heat and moisture transfer was presented. Both heat and moisture transfer in the building envelope and indoor air were simultaneously considered; their interactions were modeled. The coupled model takes into account most of the main hygrothermal effects in buildings. The coupled system model was implemented in MATLAB-Simulink, and validated by using a series of published testing tools. The new program was applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption under different climates. The results show that the use of more detailed simulation routines can result in improvements to the building's design for energy optimisation through the choice of proper hygroscopic materials, which would not be indicated by simpler calculation techniques.
Resumo:
This paper investigates the environmental conditions inside a highly-glazed cross-ventilated meeting room. A 3D computational fluid dynamics (CFD) model of an indoor environment is developed with the support of the field measurements performed in a normally operating room. The work presented here follows the steps of the formal calibration methodology for the development of CFD models of naturally ventilated environments. This paper utilises the calibration methodology in order to predict environmental conditions within the highly-glazed cross-ventilated room occupied by people. The CFD model is verified and validated with field measurements performed in an operating building. Moreover, parametric analysis determines the most influential boundary conditions on indoor air temperatures and air speeds